Study guide

12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses

FE Other Disciplines Fundamentals of Engineering

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Strategy

About the FE Other Disciplines Exam How to Use This Study Guide

2 Chapter 1: Mathematics

1.1 Analytic Geometry, Trigonometry, and Vector Operations 1.2 Differential and Integral Calculus 1.3 Ordinary Differential Equations and Laplace Transforms 1.4 Linear Algebra, Matrices, and Systems of Equations 1.5 Numerical Methods, Root-Finding, and Numerical Integration

3 Chapter 2: Probability and Statistics

2.1 Probability Distributions, PMFs, and PDFs 2.2 Expected Value, Mean, Variance, and Descriptive Statistics 2.3 Estimation, Confidence Intervals, and Sample Sizes 2.4 Hypothesis Testing, Goodness of Fit, and Linear Regression

4 Chapter 3: Chemistry

3.1 Stoichiometry, Chemical Reactions, and Solutions 3.2 Chemical Equilibrium, Acids/Bases, and Ideal Gas Laws 3.3 Oxidation-Reduction, Electrochemistry, and Corrosion Basics

5 Chapter 4: Instrumentation and Controls

4.1 Sensors, Transducers, and Signal Conditioning 4.2 Data Sampling, Accuracy/Precision, and A/D Conversion 4.3 Logic Diagrams, Boolean Algebra, and Control Logic

6 Chapter 5: Engineering Ethics and Societal Impacts

5.1 NCEES Model Rules of Professional Conduct and Codes of Ethics 5.2 Public Protection, Licensure Boards, and Professional Liability 5.3 Societal Impacts: Sustainability, Life-Cycle Analysis, and Public Safety

7 Chapter 6: Safety, Health, and Environment

6.1 OSHA Regulations, Industrial Hygiene, and PPE 6.2 Hazard Assessment, Risk Management, and Environmental Rules 6.3 Gas Detection and Monitoring 6.4 Electrical Safety 6.5 Confined Space Entry and Ventilation Rates

8 Chapter 7: Engineering Economics

7.1 Time Value of Money, Interest Formulas, and Cash Flow Diagrams 7.2 Capital Budgeting: Present Worth, Annual Worth, IRR, and B/C Ratio 7.3 Depreciation Methods, Income Taxes, and Breakeven Analysis 7.4 Cost Analysis, Uncertainty, Expected Value, and Decision Trees

9 Chapter 8: Statics

8.1 Statics Equilibrium, Free-Body Diagrams, and Force Systems 8.2 Distributed Loads, Resultants, and Equivalent Force-Couple Systems 8.3 Internal Forces in Rigid Bodies: Trusses, Frames, Machines, and Friction 8.4 Three-Dimensional Equilibrium, Cables, and Pulley Systems 8.5 Area Properties: Centroids, Moments of Inertia, and Radius of Gyration 8.6 Weight, Mass, and Force Units: slug, lbm, lbf, and g_c

10 Chapter 9: Dynamics

9.1 Kinematics of Particles and Rigid Bodies 9.2 Newton's Second Law for Particles and Rigid Bodies 9.3 Angular Motion, Torque, and Mass Moment of Inertia 9.4 Work-Energy Principle, Power, and Efficiency 9.5 Impulse-Momentum, Impact, and Coefficient of Restitution 9.6 Dynamic Friction and Vibrations: Natural Frequency and Damping

11 Chapter 10: Strength of Materials

10.1 Stress Types, Axial Stress-Strain, and Thermal Deformation 10.2 Torsion of Circular Shafts, Polar Moment, and Angle of Twist 10.3 Shear and Moment Diagrams 10.4 Flexural Bending Stress and Transverse Shear Stress 10.5 Stress Transformations, Principal Stresses, and Mohr's Circle 10.6 Beam Deflections and Combined Axial/Bending Loading 10.7 Column Buckling (Euler Formula) and Yield/Failure Criteria

12 Chapter 11: Materials

11.1 Crystal Structure, Phase Diagrams, and Material Processing 11.2 Mechanical Properties, Fatigue, Fracture, and Corrosion 11.3 Thermal Properties of Materials 11.4 Electrical and Chemical Properties of Materials 11.5 Material Selection for Engineering Design

13 Chapter 12: Fluid Mechanics

12.1 Fluid Properties, Hydrostatic Pressure, and Manometry 12.2 Dimensionless Numbers and Flow Regimes 12.3 Continuity Equation, Bernoulli Equation, and Energy Equation 12.4 Impulse-Momentum Equation and Forces on Control Volumes 12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses 12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors 12.7 Open-Channel Flow, Manning's Equation, and Drag 12.8 Fluid Transport Systems and Flow Measurement 12.9 Ideal Gas Law, Gas Mixtures, and the Real Gas Law

14 Chapter 13: Basic Electrical Engineering

13.1 Electrical Fundamentals, Ohm's Law, and DC Circuits 13.2 AC Circuits, Phasors, Impedance, and Three-Phase Power 13.3 Magnetic Fields, Induction, Transformers, and Motor Efficiency 13.4 Electrical Measuring Devices: Voltmeter, Ammeter, and Wattmeter

15 Chapter 14: Thermodynamics and Heat Transfer

14.1 First & Second Laws of Thermodynamics and Pure Substance Properties 14.2 Thermodynamic Processes and Property Diagrams (T-s, P-h, P-v) 14.3 Heat Transfer: Conduction, Convection, and Radiation 14.4 Ideal Gas Processes and Power/Refrigeration Cycles 14.5 Mass and Energy Balances on Control Volumes 14.6 Combustion and Combustion Products 14.7 Psychrometrics: Relative Humidity, Wet-Bulb Temperature, and the Psychrometric Chart

12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses

Key Takeaways Explain This Topic AI

The flow regime in a conduit is characterized by the dimensionless Reynolds number Re = (rho * V * D) / mu = (V * D) / nu; flow is strictly laminar for Re < 2300 and fully turbulent for Re > 4000.

In laminar pipe flow, the Darcy friction factor is independent of surface roughness and governed entirely by Hagen-Poiseuille theory: f = 64 / Re, with a parabolic velocity profile where V_max = 2 * V_avg.

In turbulent flow, the friction factor f depends on both Reynolds number Re and relative roughness epsilon / D, evaluated using the implicit Colebrook equation or explicit Swamee-Jain approximation.

Major friction head loss is calculated using the Darcy-Weisbach equation h_f = f * (L/D) * (V^2 / 2g), while minor losses from fittings and valves use h_m = K * (V^2 / 2g).

For non-circular ducts, calculations substitute hydraulic diameter D_h = 4 * A / P_w in place of circular pipe diameter D.

Last updated: August 2026

12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses

Core FE Exam Principle: Viscous friction along internal conduit walls degrades mechanical fluid energy into thermal energy. Pipe flow performance depends critically on whether the boundary layer flow regime is laminar, transitional, or turbulent.

Characterizing Flow Regimes: The Reynolds Number

The Reynolds Number ((Re)) represents the ratio of inertial forces to viscous forces within a fluid element: R e = ρ V D μ = V D ν Re = \frac{\rho V D}{\mu} = \frac{V D}{\nu} R e = μ ρ V D ​ = ν V D ​

where:

  • (V) = Average flow velocity ( m/s \text{m/s} m/s or ft/s \text{ft/s} ft/s )
  • (D) = Pipe internal diameter ( m \text{m} m or ft \text{ft} ft )
  • μ \mu μ = Dynamic viscosity ( Pa ⋅ s \text{Pa}\cdot\text{s} Pa ⋅ s )
  • ν \nu ν = Kinematic viscosity ( m 2 / s \text{m}^2/\text{s} m 2 / s )
  • Critical Flow Boundaries for Circular Pipes

Laminar Flow ((Re < 2300)): Fluid moves in smooth parallel layers (laminae) without lateral mixing. Viscous forces dominate.

Transitional Flow ( 2300 ≤ R e ≤ 4000 2300 \le Re \le 4000 2300 ≤ R e ≤ 4000 ): Unstable flow fluctuating unpredictably between laminar and turbulent behavior.

Turbulent Flow ((Re > 4000)): Chaotic, highly agitated flow characterized by random three-dimensional velocity fluctuations and rapid scalar mixing.

Non-Circular Conduits and Hydraulic Diameter

For non-circular cross-sections (e.g., rectangular HVAC ducts or concentric annular pipes), define the Hydraulic Diameter ( D h D_h D h ​ ) : D h = 4 A P w D_h = \frac{4 A}{P_w} D h ​ = P w ​ 4 A ​

where (A) is the fluid cross-sectional area and P w P_w P w ​ is the wetted perimeter in contact with the fluid.

Rectangular Duct ( a × b a \times b a × b ): D h = 4 ( a b ) 2 ( a + b ) = 2 a b a + b D_h = \frac{4(ab)}{2(a+b)} = \frac{2ab}{a+b} D h ​ = 2 ( a + b ) 4 ( ab ) ​ = a + b 2 ab ​ .

Concentric Annulus (Inner D i D_i D i ​ , Outer D o D_o D o ​ ): D h = 4 ⋅ π 4 ( D o 2 − D i 2 ) π ( D o + D i ) = D o − D i D_h = \frac{4 \cdot \frac{\pi}{4}(D_o^2 - D_i^2)}{\pi(D_o + D_i)} = D_o - D_i D h ​ = π ( D o ​ + D i ​ ) 4 ⋅ 4 π ​ ( D o 2 ​ − D i 2 ​ ) ​ = D o ​ − D i ​ .

Laminar Pipe Flow (Hagen-Poiseuille Flow)

In fully developed laminar pipe flow, exact analytical solutions describe the velocity field.

Laminar Velocity Profile ν ( r ) = V max [ 1 − ( r R ) 2 ] \nu(r) = V_{\text{max}} \left[ 1 - \left(\frac{r}{R}\right)^2 \right] ν ( r ) = V max ​ [ 1 − ( R r ​ ) 2 ]

The velocity distribution is parabolic, reaching maximum velocity V max V_{\text{max}} V max ​ along the pipe centerline ((r=0)).

Average Velocity Relation: V avg = 1 2 V max V_{\text{avg}} = \frac{1}{2} V_{\text{max}} V avg ​ = 2 1 ​ V max ​

Wall Shear Stress ( τ w \tau_w τ w ​ ): τ w = − μ d u d r ∣ r = R = 4 μ V avg R = 8 μ V avg D \tau_w = -\mu \left. \frac{du}{dr} \right|_{r=R} = \frac{4 \mu V_{\text{avg}}}{R} = \frac{8 \mu V_{\text{avg}}}{D} τ w ​ = − μ d r d u ​ ​ r = R ​ = R 4 μ V avg ​ ​ = D 8 μ V avg ​ ​

Laminar Friction Factor

By equating wall shear stress to pressure drop, the friction factor for laminar pipe flow simplifies to an inverse function of Reynolds number, completely independent of pipe wall roughness ( ϵ \epsilon ϵ ) : f = 64 R e f = \frac{64}{Re} f = R e 64 ​

Substituting f = 64 R e f = \frac{64}{Re} f = R e 64 ​ into the Darcy-Weisbach equation yields the Hagen-Poiseuille Equation for laminar pressure drop: Δ P = 32 μ L V avg D 2 \Delta P = \frac{32 \mu L V_{\text{avg}}}{D^2} Δ P = D 2 32 μL V avg ​ ​

Turbulent Pipe Flow and the Moody Diagram

In turbulent flow, random eddy motion increases wall momentum transfer, making the Darcy friction factor (f) a function of both Reynolds number ((Re)) and relative roughness ( ϵ / D \epsilon/D ϵ / D ) .

Equivalent Surface Roughness ( ϵ \epsilon ϵ )

  • Pipe Material Equivalent Roughness ϵ \epsilon ϵ [mm] Equivalent Roughness ϵ \epsilon ϵ [ft]
  • Drawn Tubing (Copper, Glass, Plastic) 0.0015 mm 0.000005 ft
  • Commercial Steel / Wrought Iron 0.045 mm 0.00015 ft
  • Asphalted Cast Iron 0.12 mm 0.0004 ft
  • Galvanized Iron 0.15 mm 0.0005 ft
  • Cast Iron 0.26 mm 0.00085 ft
  • Riveted Steel 0.9 - 9.0 mm 0.003 - 0.03 ft
  • Friction Factor Equations

Colebrook Equation (Implicit): Standard benchmark for turbulent pipe flow across all roughness ranges: 1 f = − 2.0 log ⁡ 10 ( ϵ / D 3.7 + 2.51 R e f ) \frac{1}{\sqrt{f}} = -2.0 \log_{10} \left( \frac{\epsilon/D}{3.7} + \frac{2.51}{Re \sqrt{f}} \right) f ​ 1 ​ = − 2.0 lo g 10 ​ ( 3.7 ϵ / D ​ + R e f ​ 2.51 ​ )

Swamee-Jain Equation (Explicit): Approximates Colebrook within 1% for 5000 ≤ R e ≤ 10 8 5000 \le Re \le 10^8 5000 ≤ R e ≤ 1 0 8 and 10 − 6 ≤ ϵ / D ≤ 10 − 2 10^{-6} \le \epsilon/D \le 10^{-2} 1 0 − 6 ≤ ϵ / D ≤ 1 0 − 2 : f = 0.25 [ log ⁡ 10 ( ϵ / D 3.7 + 5.74 R e 0.9 ) ] 2 f = \frac{0.25}{\left[ \log_{10} \left( \frac{\epsilon/D}{3.7} + \frac{5.74}{Re^{0.9}} \right) \right]^2} f = [ lo g 10 ​ ( 3.7 ϵ / D ​ + R e 0.9 5.74 ​ ) ] 2 0.25 ​

Wholly Turbulent (Fully Rough) Zone: At extremely high Reynolds numbers, viscous forces become negligible relative to roughness drag. The friction factor becomes independent of (Re): 1 f = − 2.0 log ⁡ 10 ( ϵ / D 3.7 ) \frac{1}{\sqrt{f}} = -2.0 \log_{10} \left( \frac{\epsilon/D}{3.7} \right) f ​ 1 ​ = − 2.0 lo g 10 ​ ( 3.7 ϵ / D ​ )

Major and Minor Head Loss Calculations

Total system head loss combines continuous pipe skin friction (major loss) with localized flow separation losses caused by fittings, valves, and geometry changes (minor loss). h L = h major + h minor = ∑ f ( L D ) V 2 2 g + ∑ K ( V 2 2 g ) h_L = h_{\text{major}} + h_{\text{minor}} = \sum f \left(\frac{L}{D}\right) \frac{V^2}{2g} + \sum K \left(\frac{V^2}{2g}\right) h L ​ = h major ​ + h minor ​ = ∑ f ( D L ​ ) 2 g V 2 ​ + ∑ K ( 2 g V 2 ​ )

Major Friction Head Loss (Darcy-Weisbach Equation) h f = f ( L D ) V 2 2 g and Δ P f = γ h f = f ( L D ) ρ V 2 2 h_f = f \left( \frac{L}{D} \right) \frac{V^2}{2g} \quad \text{and} \quad \Delta P_f = \gamma h_f = f \left( \frac{L}{D} \right) \frac{\rho V^2}{2} h f ​ = f ( D L ​ ) 2 g V 2 ​ and Δ P f ​ = γ h f ​ = f ( D L ​ ) 2 ρ V 2 ​

Minor Loss Coefficient Method ((K)) h m = K ( V 2 2 g ) h_m = K \left( \frac{V^2}{2g} \right) h m ​ = K ( 2 g V 2 ​ )

Entrance Losses:

  • Sharp-Edged Entrance: (K = 0.5)
  • Well-Rounded Entrance ( r / D ≥ 0.15 r/D \ge 0.15 r / D ≥ 0.15 ): (K = 0.04)
  • Re-entrant Entrance (pipe projecting inward): (K = 0.8)

Exit Loss (Submerged Pipe Discharge into Reservoir): (K = 1.0) (all kinetic energy is dissipated as heat).

Valves and Fittings: Gate valve (fully open (K=0.2)), Globe valve (fully open (K=10.0)), 90 ∘ 90^\circ 9 0 ∘ standard elbow ((K=0.9)). Entrance Losses K: Exit Loss K = 1.0:

------------------ ------------------

Re-entrant: K = 0.8 Submerged Discharge:

  • Sharp-edge: K = 0.5 ===========\\
  • Rounded: K = 0.04 ===========/ ===> Discharges into open tank

Entire kinetic energy lost!

  • Pipe Networks: Series and Parallel Systems
  • Series Pipe Systems

Pipes connected end-to-end carrying a single flow stream.

Flow Rate: Q 1 = Q 2 = Q 3 = Q total Q_1 = Q_2 = Q_3 = Q_{\text{total}} Q 1 ​ = Q 2 ​ = Q 3 ​ = Q total ​

Total Head Loss: h L , total = h L , 1 + h L , 2 + h L , 3 h_{L,\text{total}} = h_{L,1} + h_{L,2} + h_{L,3} h L , total ​ = h L , 1 ​ + h L , 2 ​ + h L , 3 ​

Parallel Pipe Systems

Flow splits into two or more parallel branches connecting common junction nodes (A) and (B).

Flow Rate: Q total = Q 1 + Q 2 + Q 3 Q_{\text{total}} = Q_1 + Q_2 + Q_3 Q total ​ = Q 1 ​ + Q 2 ​ + Q 3 ​

Head Loss Equality: Head loss across all parallel branches must be equal: h L , 1 = h L , 2 = h L , 3 = h L , A B h_{L,1} = h_{L,2} = h_{L,3} = h_{L, AB} h L , 1 ​ = h L , 2 ​ = h L , 3 ​ = h L , A B ​ Since h f = 8 f L Q 2 π 2 g D 5 , f 1 L 1 Q 1 2 D 1 5 = f 2 L 2 Q 2 2 D 2 5 ⟹ Q 1 Q 2 = f 2 L 2 D 1 5 f 1 L 1 D 2 5 \text{Since } h_f = \frac{8 f L Q^2}{\pi^2 g D^5}, \quad \frac{f_1 L_1 Q_1^2}{D_1^5} = \frac{f_2 L_2 Q_2^2}{D_2^5} \implies \frac{Q_1}{Q_2} = \sqrt{\frac{f_2 L_2 D_1^5}{f_1 L_1 D_2^5}} Since h f ​ = π 2 g D 5 8 f L Q 2 ​ , D 1 5 ​ f 1 ​ L 1 ​ Q 1 2 ​ ​ = D 2 5 ​ f 2 ​ L 2 ​ Q 2 2 ​ ​ ⟹ Q 2 ​ Q 1 ​ ​ = f 1 ​ L 1 ​ D 2 5 ​ f 2 ​ L 2 ​ D 1 5 ​ ​ ​

  • Comprehensive Worked Engineering Example
  • Problem Statement

A commercial steel pipeline ( ϵ = 0.045 mm \epsilon = 0.045 \text{ mm} ϵ = 0.045 mm ) with internal diameter D = 200 mm D = 200 \text{ mm} D = 200 mm and total length L = 250 m L = 250 \text{ m} L = 250 m conveys water ( ρ = 1000 kg/m 3 \rho = 1000 \text{ kg/m}^3 ρ = 1000 kg/m 3 , ν = 1.0 × 10 − 6 m 2 / s \nu = 1.0 \times 10^{-6} \text{ m}^2/\text{s} ν = 1.0 × 1 0 − 6 m 2 / s , γ = 9.81 kN/m 3 \gamma = 9.81 \text{ kN/m}^3 γ = 9.81 kN/m 3 ) at a volumetric flow rate Q = 0.06283 m 3 / s Q = 0.06283 \text{ m}^3/\text{s} Q = 0.06283 m 3 / s .

The pipeline contains the following fittings:

  • 1 sharp-edged entrance ( K 1 = 0.5 K_1 = 0.5 K 1 ​ = 0.5 )
  • 4 standard 90 ∘ 90^\circ 9 0 ∘ threaded elbows ( K 2 = 0.9 K_2 = 0.9 K 2 ​ = 0.9 each)
  • 1 fully open globe valve ( K 3 = 10.0 K_3 = 10.0 K 3 ​ = 10.0 )
  • 1 submerged exit ( K 4 = 1.0 K_4 = 1.0 K 4 ​ = 1.0 )

Calculate:

The Reynolds number (Re) and flow regime.

The friction factor (f) using the Swamee-Jain equation.

The total head loss h L h_L h L ​ across the pipeline.

The required pressure drop Δ P \Delta P Δ P along a horizontal installation.

  • Step-by-Step Solution
  • Step 1: Compute Flow Velocity and Reynolds Number

Pipe cross-sectional area: A = π D 2 4 = π ( 0.200 ) 2 4 = 0.031416 m 2 A = \frac{\pi D^2}{4} = \frac{\pi (0.200)^2}{4} = 0.031416 \text{ m}^2 A = 4 π D 2 ​ = 4 π ( 0.200 ) 2 ​ = 0.031416 m 2

Average flow velocity: V = Q A = 0.06283 m 3 / s 0.031416 m 2 = 2.00 m/s V = \frac{Q}{A} = \frac{0.06283 \text{ m}^3/\text{s}}{0.031416 \text{ m}^2} = 2.00 \text{ m/s} V = A Q ​ = 0.031416 m 2 0.06283 m 3 / s ​ = 2.00 m/s

Velocity head: V 2 2 g = ( 2.00 ) 2 2 × 9.81 = 4.00 19.62 = 0.20387 m \frac{V^2}{2g} = \frac{(2.00)^2}{2 \times 9.81} = \frac{4.00}{19.62} = 0.20387 \text{ m} 2 g V 2 ​ = 2 × 9.81 ( 2.00 ) 2 ​ = 19.62 4.00 ​ = 0.20387 m

Reynolds number: R e = V D ν = 2.00 × 0.200 1.0 × 10 − 6 = 400 , 000 = 4.0 × 10 5 Re = \frac{V D}{\nu} = \frac{2.00 \times 0.200}{1.0 \times 10^{-6}} = 400,000 = 4.0 \times 10^5 R e = ν V D ​ = 1.0 × 1 0 − 6 2.00 × 0.200 ​ = 400 , 000 = 4.0 × 1 0 5 Since R e = 4.0 × 10 5 > 4000 Re = 4.0 \times 10^5 > 4000 R e = 4.0 × 1 0 5 > 4000 , the flow is fully turbulent .

Step 2: Compute Relative Roughness and Friction Factor (f)

Relative roughness: ϵ D = 0.045 mm 200 mm = 0.000225 \frac{\epsilon}{D} = \frac{0.045 \text{ mm}}{200 \text{ mm}} = 0.000225 D ϵ ​ = 200 mm 0.045 mm ​ = 0.000225

Swamee-Jain explicit equation: f = 0.25 [ log ⁡ 10 ( 0.000225 3.7 + 5.74 ( 400 , 000 ) 0.9 ) ] 2 f = \frac{0.25}{\left[ \log_{10} \left( \frac{0.000225}{3.7} + \frac{5.74}{(400,000)^{0.9}} \right) \right]^2} f = [ lo g 10 ​ ( 3.7 0.000225 ​ + ( 400 , 000 ) 0.9 5.74 ​ ) ] 2 0.25 ​ 0.000225 3.7 = 6.081 × 10 − 5 , ( 400 , 000 ) 0.9 = 115 , 974 ⟹ 5.74 115 , 974 = 4.949 × 10 − 5 \frac{0.000225}{3.7} = 6.081 \times 10^{-5}, \quad (400,000)^{0.9} = 115,974 \implies \frac{5.74}{115,974} = 4.949 \times 10^{-5} 3.7 0.000225 ​ = 6.081 × 1 0 − 5 , ( 400 , 000 ) 0.9 = 115 , 974 ⟹ 115 , 974 5.74 ​ = 4.949 × 1 0 − 5 Sum = 6.081 × 10 − 5 + 4.949 × 10 − 5 = 1.103 × 10 − 4 \text{Sum} = 6.081 \times 10^{-5} + 4.949 \times 10^{-5} = 1.103 \times 10^{-4} Sum = 6.081 × 1 0 − 5 + 4.949 × 1 0 − 5 = 1.103 × 1 0 − 4 log ⁡ 10 ( 1.103 × 10 − 4 ) = − 3.9574 ⟹ ( − 3.9574 ) 2 = 15.661 \log_{10}(1.103 \times 10^{-4}) = -3.9574 \implies (-3.9574)^2 = 15.661 lo g 10 ​ ( 1.103 × 1 0 − 4 ) = − 3.9574 ⟹ ( − 3.9574 ) 2 = 15.661 f = 0.25 15.661 = 0.01596 ≈ 0.0160 f = \frac{0.25}{15.661} = 0.01596 \approx 0.0160 f = 15.661 0.25 ​ = 0.01596 ≈ 0.0160

Step 3: Compute Major and Minor Head Losses

Major friction head loss: h f = f ( L D ) V 2 2 g = 0.01596 × ( 250 0.200 ) × 0.20387 = 0.01596 × 1250 × 0.20387 = 4.067 m h_f = f \left(\frac{L}{D}\right) \frac{V^2}{2g} = 0.01596 \times \left(\frac{250}{0.200}\right) \times 0.20387 = 0.01596 \times 1250 \times 0.20387 = 4.067 \text{ m} h f ​ = f ( D L ​ ) 2 g V 2 ​ = 0.01596 × ( 0.200 250 ​ ) × 0.20387 = 0.01596 × 1250 × 0.20387 = 4.067 m

Minor loss coefficient sum: ∑ K = K entrance + 4 ( K elbow ) + K valve + K exit = 0.5 + 4 ( 0.9 ) + 10.0 + 1.0 = 0.5 + 3.6 + 10.0 + 1.0 = 15.1 \sum K = K_{\text{entrance}} + 4(K_{\text{elbow}}) + K_{\text{valve}} + K_{\text{exit}} = 0.5 + 4(0.9) + 10.0 + 1.0 = 0.5 + 3.6 + 10.0 + 1.0 = 15.1 ∑ K = K entrance ​ + 4 ( K elbow ​ ) + K valve ​ + K exit ​ = 0.5 + 4 ( 0.9 ) + 10.0 + 1.0 = 0.5 + 3.6 + 10.0 + 1.0 = 15.1

Minor head loss: h m = ∑ K ( V 2 2 g ) = 15.1 × 0.20387 = 3.078 m h_m = \sum K \left(\frac{V^2}{2g}\right) = 15.1 \times 0.20387 = 3.078 \text{ m} h m ​ = ∑ K ( 2 g V 2 ​ ) = 15.1 × 0.20387 = 3.078 m

Total head loss: h L = h f + h m = 4.067 + 3.078 = 7.145 m h_L = h_f + h_m = 4.067 + 3.078 = 7.145 \text{ m} h L ​ = h f ​ + h m ​ = 4.067 + 3.078 = 7.145 m

Step 4: Compute Required Pressure Drop

For a horizontal pipeline ( z 1 = z 2 z_1 = z_2 z 1 ​ = z 2 ​ ) of constant diameter ( V 1 = V 2 V_1 = V_2 V 1 ​ = V 2 ​ ): Δ P = γ h L = 9.81 kN/m 3 × 7.145 m = 70.09 kPa \Delta P = \gamma h_L = 9.81 \text{ kN/m}^3 \times 7.145 \text{ m} = 70.09 \text{ kPa} Δ P = γ h L ​ = 9.81 kN/m 3 × 7.145 m = 70.09 kPa

Final Answer: R e = 4.0 × 10 5 Re = 4.0 \times 10^5 R e = 4.0 × 1 0 5 (turbulent), friction factor (f = 0.0160), total head loss h L = 7.15 m h_L = 7.15 \text{ m} h L ​ = 7.15 m , and pressure drop Δ P = 70.1 kPa \Delta P = 70.1 \text{ kPa} Δ P = 70.1 kPa .