Study guide

12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors

FE Other Disciplines Fundamentals of Engineering

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Strategy

About the FE Other Disciplines Exam How to Use This Study Guide

2 Chapter 1: Mathematics

1.1 Analytic Geometry, Trigonometry, and Vector Operations 1.2 Differential and Integral Calculus 1.3 Ordinary Differential Equations and Laplace Transforms 1.4 Linear Algebra, Matrices, and Systems of Equations 1.5 Numerical Methods, Root-Finding, and Numerical Integration

3 Chapter 2: Probability and Statistics

2.1 Probability Distributions, PMFs, and PDFs 2.2 Expected Value, Mean, Variance, and Descriptive Statistics 2.3 Estimation, Confidence Intervals, and Sample Sizes 2.4 Hypothesis Testing, Goodness of Fit, and Linear Regression

4 Chapter 3: Chemistry

3.1 Stoichiometry, Chemical Reactions, and Solutions 3.2 Chemical Equilibrium, Acids/Bases, and Ideal Gas Laws 3.3 Oxidation-Reduction, Electrochemistry, and Corrosion Basics

5 Chapter 4: Instrumentation and Controls

4.1 Sensors, Transducers, and Signal Conditioning 4.2 Data Sampling, Accuracy/Precision, and A/D Conversion 4.3 Logic Diagrams, Boolean Algebra, and Control Logic

6 Chapter 5: Engineering Ethics and Societal Impacts

5.1 NCEES Model Rules of Professional Conduct and Codes of Ethics 5.2 Public Protection, Licensure Boards, and Professional Liability 5.3 Societal Impacts: Sustainability, Life-Cycle Analysis, and Public Safety

7 Chapter 6: Safety, Health, and Environment

6.1 OSHA Regulations, Industrial Hygiene, and PPE 6.2 Hazard Assessment, Risk Management, and Environmental Rules 6.3 Gas Detection and Monitoring 6.4 Electrical Safety 6.5 Confined Space Entry and Ventilation Rates

8 Chapter 7: Engineering Economics

7.1 Time Value of Money, Interest Formulas, and Cash Flow Diagrams 7.2 Capital Budgeting: Present Worth, Annual Worth, IRR, and B/C Ratio 7.3 Depreciation Methods, Income Taxes, and Breakeven Analysis 7.4 Cost Analysis, Uncertainty, Expected Value, and Decision Trees

9 Chapter 8: Statics

8.1 Statics Equilibrium, Free-Body Diagrams, and Force Systems 8.2 Distributed Loads, Resultants, and Equivalent Force-Couple Systems 8.3 Internal Forces in Rigid Bodies: Trusses, Frames, Machines, and Friction 8.4 Three-Dimensional Equilibrium, Cables, and Pulley Systems 8.5 Area Properties: Centroids, Moments of Inertia, and Radius of Gyration 8.6 Weight, Mass, and Force Units: slug, lbm, lbf, and g_c

10 Chapter 9: Dynamics

9.1 Kinematics of Particles and Rigid Bodies 9.2 Newton's Second Law for Particles and Rigid Bodies 9.3 Angular Motion, Torque, and Mass Moment of Inertia 9.4 Work-Energy Principle, Power, and Efficiency 9.5 Impulse-Momentum, Impact, and Coefficient of Restitution 9.6 Dynamic Friction and Vibrations: Natural Frequency and Damping

11 Chapter 10: Strength of Materials

10.1 Stress Types, Axial Stress-Strain, and Thermal Deformation 10.2 Torsion of Circular Shafts, Polar Moment, and Angle of Twist 10.3 Shear and Moment Diagrams 10.4 Flexural Bending Stress and Transverse Shear Stress 10.5 Stress Transformations, Principal Stresses, and Mohr's Circle 10.6 Beam Deflections and Combined Axial/Bending Loading 10.7 Column Buckling (Euler Formula) and Yield/Failure Criteria

12 Chapter 11: Materials

11.1 Crystal Structure, Phase Diagrams, and Material Processing 11.2 Mechanical Properties, Fatigue, Fracture, and Corrosion 11.3 Thermal Properties of Materials 11.4 Electrical and Chemical Properties of Materials 11.5 Material Selection for Engineering Design

13 Chapter 12: Fluid Mechanics

12.1 Fluid Properties, Hydrostatic Pressure, and Manometry 12.2 Dimensionless Numbers and Flow Regimes 12.3 Continuity Equation, Bernoulli Equation, and Energy Equation 12.4 Impulse-Momentum Equation and Forces on Control Volumes 12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses 12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors 12.7 Open-Channel Flow, Manning's Equation, and Drag 12.8 Fluid Transport Systems and Flow Measurement 12.9 Ideal Gas Law, Gas Mixtures, and the Real Gas Law

14 Chapter 13: Basic Electrical Engineering

13.1 Electrical Fundamentals, Ohm's Law, and DC Circuits 13.2 AC Circuits, Phasors, Impedance, and Three-Phase Power 13.3 Magnetic Fields, Induction, Transformers, and Motor Efficiency 13.4 Electrical Measuring Devices: Voltmeter, Ammeter, and Wattmeter

15 Chapter 14: Thermodynamics and Heat Transfer

14.1 First & Second Laws of Thermodynamics and Pure Substance Properties 14.2 Thermodynamic Processes and Property Diagrams (T-s, P-h, P-v) 14.3 Heat Transfer: Conduction, Convection, and Radiation 14.4 Ideal Gas Processes and Power/Refrigeration Cycles 14.5 Mass and Energy Balances on Control Volumes 14.6 Combustion and Combustion Products 14.7 Psychrometrics: Relative Humidity, Wet-Bulb Temperature, and the Psychrometric Chart

12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors

Key Takeaways Explain This Topic AI

Centrifugal pumps add mechanical head to fluids, where hydraulic power W_hyd = gamma * Q * h_p and shaft input power P_shaft = W_hyd / eta_pump.

Net Positive Suction Head Available (NPSHA = (P_suction,abs - P_v)/gamma + V_s^2/(2g)) must strictly exceed Net Positive Suction Head Required (NPSHR) to prevent destructive pump cavitation.

Pump affinity laws dictate scaling behavior for speed N: volumetric flow rate Q scales linearly (Q ~ N), head h_p scales quadratically (h_p ~ N^2), and shaft power P scales cubically (P ~ N^3).

Fluid compressibility becomes significant when Mach number Ma = V / c > 0.3, where local speed of sound in ideal gas is c = sqrt(k * R * T).

In isentropic nozzle flows, choked sonic flow (Ma = 1.0) occurs at the minimum throat area when the pressure ratio drops to the critical pressure ratio P*/P_0 = (2 / (k+1))^(k / (k-1)) (0.5283 for air with k=1.4).

Last updated: August 2026

12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors

Core FE Exam Principle: Turbomachines transfer energy between a fluid continuous medium and a rotating shaft. Pumps add mechanical energy to fluids, whereas turbines extract hydraulic energy. Gas dynamics analyzes compressible fluid flows where density varies significantly with pressure and temperature.

Pump Performance and System Operating Points

A pump operates at the intersection of its Pump Head-Capacity Curve ( H pump H_{\text{pump}} H pump ​ vs. (Q)) and the system's System Head Curve ( H sys H_{\text{sys}} H sys ​ vs. (Q)) .

System Head Curve Equation H sys ( Q ) = ( z 2 − z 1 ) + P 2 − P 1 γ + [ ∑ f ( L D ) + ∑ K ] Q 2 2 g A 2 = h static + K sys Q 2 H_{\text{sys}}(Q) = (z_2 - z_1) + \frac{P_2 - P_1}{\gamma} + \left[ \sum f \left(\frac{L}{D}\right) + \sum K \right] \frac{Q^2}{2g A^2} = h_{\text{static}} + K_{\text{sys}} Q^2 H sys ​ ( Q ) = ( z 2 ​ − z 1 ​ ) + γ P 2 ​ − P 1 ​ ​ + [ ∑ f ( D L ​ ) + ∑ K ] 2 g A 2 Q 2 ​ = h static ​ + K sys ​ Q 2

Operating Point: Found by equating H pump ( Q ) = H sys ( Q ) H_{\text{pump}}(Q) = H_{\text{sys}}(Q) H pump ​ ( Q ) = H sys ​ ( Q ) . Head [m] ^

  • | Pump Performance Curve H_pump(Q)
  • | \\
  • | \\ Operating Point
  • |-----\\---------> (Q_op, H_op)
  • | \\ /
  • | \\ /
  • | \\ / System Head Curve H_sys = h_static + K*Q^2
  • |________(o)__/________________________>
  • 0 Flow Rate Q [m^3/s]
  • Efficiencies

Pump Hydraulic Efficiency ( η pump \eta_{\text{pump}} η pump ​ ): η pump = W hyd P shaft = γ Q h p P shaft \eta_{\text{pump}} = \frac{W_{\text{hyd}}}{P_{\text{shaft}}} = \frac{\gamma Q h_p}{P_{\text{shaft}}} η pump ​ = P shaft ​ W hyd ​ ​ = P shaft ​ γ Q h p ​ ​

Overall Wire-to-Water Efficiency ( η overall \eta_{\text{overall}} η overall ​ ): η overall = η pump ⋅ η motor = γ Q h p P electrical \eta_{\text{overall}} = \eta_{\text{pump}} \cdot \eta_{\text{motor}} = \frac{\gamma Q h_p}{P_{\text{electrical}}} η overall ​ = η pump ​ ⋅ η motor ​ = P electrical ​ γ Q h p ​ ​

Net Positive Suction Head (NPSH) and Cavitation

To prevent cavitation inside a pump impeller, the static pressure at the pump inlet flange must remain safely above the fluid vapor pressure P v P_v P v ​ .

Net Positive Suction Head Available (NPSHA)

Calculated based on suction piping system hydraulics: N P S H A = P s , abs γ + V s 2 2 g − P v γ = P atm γ + P s , gage γ + V s 2 2 g − P v γ NPSHA = \frac{P_{s,\text{abs}}}{\gamma} + \frac{V_s^2}{2g} - \frac{P_v}{\gamma} = \frac{P_{\text{atm}}}{\gamma} + \frac{P_{s,\text{gage}}}{\gamma} + \frac{V_s^2}{2g} - \frac{P_v}{\gamma} NPS H A = γ P s , abs ​ ​ + 2 g V s 2 ​ ​ − γ P v ​ ​ = γ P atm ​ ​ + γ P s , gage ​ ​ + 2 g V s 2 ​ ​ − γ P v ​ ​

If the suction supply reservoir is an open atmospheric tank located distance h z h_z h z ​ relative to the pump inlet centerline: N P S H A = P atm − P v γ ± h z − h L , suction NPSHA = \frac{P_{\text{atm}} - P_v}{\gamma} \pm h_z - h_{L,\text{suction}} NPS H A = γ P atm ​ − P v ​ ​ ± h z ​ − h L , suction ​

Use + h z +h_z + h z ​ if the liquid level is above the pump inlet (static suction head).

Use − h z -h_z − h z ​ if the liquid level is below the pump inlet (static suction lift).

Cavitation Prevention Criterion N P S H A ≥ N P S H R NPSHA \ge NPSHR NPS H A ≥ NPS H R

where (NPSHR) is the Net Positive Suction Head Required published by the pump manufacturer based on experimental testing.

Homologous Turbomachinery and Pump Affinity Laws

The Affinity Laws govern performance changes for geometrically similar centrifugal pumps operating at different rotational speeds ((N)) or impeller diameters ((D)).

Varying Rotational Speed (N) (Fixed Impeller Diameter (D))

Volumetric Flow Rate: Proportional to rotational speed ( Q ∝ N Q \propto N Q ∝ N ): Q 1 Q 2 = N 1 N 2 \frac{Q_1}{Q_2} = \frac{N_1}{N_2} Q 2 ​ Q 1 ​ ​ = N 2 ​ N 1 ​ ​

Pump Head: Proportional to the square of rotational speed ( h p ∝ N 2 h_p \propto N^2 h p ​ ∝ N 2 ): h p 1 h p 2 = ( N 1 N 2 ) 2 \frac{h_{p1}}{h_{p2}} = \left(\frac{N_1}{N_2}\right)^2 h p 2 ​ h p 1 ​ ​ = ( N 2 ​ N 1 ​ ​ ) 2

Shaft Power: Proportional to the cube of rotational speed ( P ∝ N 3 P \propto N^3 P ∝ N 3 ): P 1 P 2 = ( N 1 N 2 ) 3 \frac{P_1}{P_2} = \left(\frac{N_1}{N_2}\right)^3 P 2 ​ P 1 ​ ​ = ( N 2 ​ N 1 ​ ​ ) 3

Combined Scaling Laws (Varying Speed (N) and Diameter (D)) Q 1 Q 2 = ( N 1 N 2 ) ( D 1 D 2 ) , h p 1 h p 2 = ( N 1 N 2 ) 2 ( D 1 D 2 ) 2 , P 1 P 2 = ( N 1 N 2 ) 3 ( D 1 D 2 ) 5 \frac{Q_1}{Q_2} = \left(\frac{N_1}{N_2}\right) \left(\frac{D_1}{D_2}\right), \quad \frac{h_{p1}}{h_{p2}} = \left(\frac{N_1}{N_2}\right)^2 \left(\frac{D_1}{D_2}\right)^2, \quad \frac{P_1}{P_2} = \left(\frac{N_1}{N_2}\right)^3 \left(\frac{D_1}{D_2}\right)^5 Q 2 ​ Q 1 ​ ​ = ( N 2 ​ N 1 ​ ​ ) ( D 2 ​ D 1 ​ ​ ) , h p 2 ​ h p 1 ​ ​ = ( N 2 ​ N 1 ​ ​ ) 2 ( D 2 ​ D 1 ​ ​ ) 2 , P 2 ​ P 1 ​ ​ = ( N 2 ​ N 1 ​ ​ ) 3 ( D 2 ​ D 1 ​ ​ ) 5

Compressible Flow Basics and Gas Dynamics

When flow velocities approach the speed of sound, fluid density variations cannot be neglected (typically when (Ma > 0.3)).

Speed of Sound and Mach Number

Speed of Sound ((c)): Propagation speed of infinitesimal pressure waves through an ideal gas: c = k R T = γ R T c = \sqrt{k R T} = \sqrt{\gamma R T} c = k RT ​ = γ RT ​

where:

k = c p / c v k = c_p/c_v k = c p ​ / c v ​ = Specific heat ratio ((k = 1.4) for diatomic air)

(R) = Specific gas constant ( R air = 287 J/(kg ⋅ K) = 1716 ft ⋅ lbf/(slug ⋅ ∘ R) R_{\text{air}} = 287 \text{ J/(kg}\cdot\text{K)} = 1716 \text{ ft}\cdot\text{lbf/(slug}\cdot^\circ\text{R)} R air ​ = 287 J/(kg ⋅ K) = 1716 ft ⋅ lbf/(slug ⋅ ∘ R) )

(T) = Absolute static temperature (Kelvin or Rankine)

Mach Number ((Ma)): Ratio of local flow velocity to local speed of sound: M a = V c = V k R T Ma = \frac{V}{c} = \frac{V}{\sqrt{k R T}} M a = c V ​ = k RT ​ V ​

Mach Regime Mach Number Range (Ma) Flow Characteristics

Incompressible Subsonic (Ma < 0.3) Density changes < 5 % < 5\% < 5% ; fluid treated as constant density.

Compressible Subsonic (0.3 < Ma < 1.0) Density variations significant; no shock waves.

Sonic (Ma = 1.0) Flow velocity exactly equals local speed of sound.

Supersonic (1.0 < Ma < 5.0) Shock waves and expansion fans form.

Hypersonic (Ma > 5.0) Severe aerothermal heating and gas dissociation.

Isentropic Stagnation Relations for Ideal Gases T 0 T = 1 + k − 1 2 M a 2 \frac{T_0}{T} = 1 + \frac{k-1}{2} Ma^2 T T 0 ​ ​ = 1 + 2 k − 1 ​ M a 2 P 0 P = ( 1 + k − 1 2 M a 2 ) k k − 1 \frac{P_0}{P} = \left( 1 + \frac{k-1}{2} Ma^2 \right)^{\frac{k}{k-1}} P P 0 ​ ​ = ( 1 + 2 k − 1 ​ M a 2 ) k − 1 k ​ ρ 0 ρ = ( 1 + k − 1 2 M a 2 ) 1 k − 1 \frac{\rho_0}{\rho} = \left( 1 + \frac{k-1}{2} Ma^2 \right)^{\frac{1}{k-1}} ρ ρ 0 ​ ​ = ( 1 + 2 k − 1 ​ M a 2 ) k − 1 1 ​

Isentropic Converging-Diverging Nozzles and Choked Flow

For flow accelerated from a stagnant reservoir ( P 0 , T 0 P_0, T_0 P 0 ​ , T 0 ​ ) through a nozzle, sonic flow ((Ma=1.0)) can occur only at the minimum cross-sectional area (throat, A ∗ A^* A ∗ ).

Critical Pressure Ratio ( P ∗ / P 0 P^*/P_0 P ∗ / P 0 ​ ): Minimum backpressure ratio required to achieve choked flow at the throat: P ∗ P 0 = ( 2 k + 1 ) k k − 1 \frac{P^*}{P_0} = \left( \frac{2}{k+1} \right)^{\frac{k}{k-1}} P 0 ​ P ∗ ​ = ( k + 1 2 ​ ) k − 1 k ​ For standard air ((k = 1.4)): P ∗ P 0 = ( 2 1.4 + 1 ) 1.4 0.4 = ( 0.8333 ) 3.5 = 0.5283 \frac{P^*}{P_0} = \left( \frac{2}{1.4+1} \right)^{\frac{1.4}{0.4}} = (0.8333)^{3.5} = 0.5283 P 0 ​ P ∗ ​ = ( 1.4 + 1 2 ​ ) 0.4 1.4 ​ = ( 0.8333 ) 3.5 = 0.5283

Key Principle: Once a nozzle is choked ( M a throat = 1.0 Ma_{\text{throat}} = 1.0 M a throat ​ = 1.0 ), decreasing downstream backpressure further cannot increase mass flow rate through the nozzle.

  • Comprehensive Worked Engineering Example
  • Problem Statement

Part A: A water pumping system draws water ( γ = 9.81 kN/m 3 \gamma = 9.81 \text{ kN/m}^3 γ = 9.81 kN/m 3 , vapor pressure P v = 2.34 kPa abs P_v = 2.34 \text{ kPa abs} P v ​ = 2.34 kPa abs ) from an open sump through a suction line. Atmospheric pressure is P atm = 101.3 kPa P_{\text{atm}} = 101.3 \text{ kPa} P atm ​ = 101.3 kPa . The pump centerline is located h z = 2.50 m h_z = 2.50 \text{ m} h z ​ = 2.50 m above the open water surface (suction lift). The suction pipe losses total h L , suction = 1.20 m h_{L,\text{suction}} = 1.20 \text{ m} h L , suction ​ = 1.20 m at a flow rate Q = 0.050 m 3 / s Q = 0.050 \text{ m}^3/\text{s} Q = 0.050 m 3 / s . The pump delivers h p = 42.0 m h_p = 42.0 \text{ m} h p ​ = 42.0 m of head with an efficiency η pump = 76 % \eta_{\text{pump}} = 76\% η pump ​ = 76% .

Calculate:

The Net Positive Suction Head Available ((NPSHA)).

The required brake horsepower (shaft input power P shaft P_{\text{shaft}} P shaft ​ ).

The new shaft power P shaft , 2 P_{\text{shaft},2} P shaft , 2 ​ if the pump speed is increased by 15 % 15\% 15% .

Part B: Air ((k = 1.4), R = 287 J/(kg ⋅ K) R = 287 \text{ J/(kg}\cdot\text{K)} R = 287 J/(kg ⋅ K) ) expands from a large supply reservoir at P 0 = 400 kPa abs P_0 = 400 \text{ kPa abs} P 0 ​ = 400 kPa abs and T 0 = 350 K T_0 = 350 \text{ K} T 0 ​ = 350 K through an isentropic converging-diverging nozzle. At a specific nozzle cross-section, the measured Mach number is (Ma = 1.60).

Calculate:

4. The local static temperature (T), static pressure (P), and flow velocity (V) at this nozzle section.

  • Step-by-Step Solution
  • Step 1: Compute NPSHA for the Pump System

Equivalent atmospheric head: P atm γ = 101.3 kPa 9.81 kN/m 3 = 10.326 m \frac{P_{\text{atm}}}{\gamma} = \frac{101.3 \text{ kPa}}{9.81 \text{ kN/m}^3} = 10.326 \text{ m} γ P atm ​ ​ = 9.81 kN/m 3 101.3 kPa ​ = 10.326 m .

Vapor pressure head: P v γ = 2.34 kPa 9.81 kN/m 3 = 0.239 m \frac{P_v}{\gamma} = \frac{2.34 \text{ kPa}}{9.81 \text{ kN/m}^3} = 0.239 \text{ m} γ P v ​ ​ = 9.81 kN/m 3 2.34 kPa ​ = 0.239 m .

NPSHA formula for suction lift: N P S H A = P atm − P v γ − h z − h L , suction NPSHA = \frac{P_{\text{atm}} - P_v}{\gamma} - h_z - h_{L,\text{suction}} NPS H A = γ P atm ​ − P v ​ ​ − h z ​ − h L , suction ​ N P S H A = 10.326 − 0.239 − 2.50 − 1.20 = 6.387 m ≈ 6.39 m NPSHA = 10.326 - 0.239 - 2.50 - 1.20 = 6.387 \text{ m} \approx 6.39 \text{ m} NPS H A = 10.326 − 0.239 − 2.50 − 1.20 = 6.387 m ≈ 6.39 m

Step 2: Compute Initial Pump Shaft Power P shaft P_{\text{shaft}} P shaft ​

Hydraulic power delivered to fluid: W hyd = γ Q h p = 9810 N/m 3 × 0.050 m 3 / s × 42.0 m = 20 , 601 W = 20.60 kW W_{\text{hyd}} = \gamma Q h_p = 9810 \text{ N/m}^3 \times 0.050 \text{ m}^3/\text{s} \times 42.0 \text{ m} = 20,601 \text{ W} = 20.60 \text{ kW} W hyd ​ = γ Q h p ​ = 9810 N/m 3 × 0.050 m 3 / s × 42.0 m = 20 , 601 W = 20.60 kW

Shaft input power: P shaft = W hyd η pump = 20.601 kW 0.76 = 27.11 kW P_{\text{shaft}} = \frac{W_{\text{hyd}}}{\eta_{\text{pump}}} = \frac{20.601 \text{ kW}}{0.76} = 27.11 \text{ kW} P shaft ​ = η pump ​ W hyd ​ ​ = 0.76 20.601 kW ​ = 27.11 kW

Step 3: Compute New Shaft Power After 15% Speed Increase

Speed ratio: N 2 N 1 = 1.15 \frac{N_2}{N_1} = 1.15 N 1 ​ N 2 ​ ​ = 1.15 .

By the affinity power law: P 2 P 1 = ( N 2 N 1 ) 3 = ( 1.15 ) 3 = 1.520875 \frac{P_2}{P_1} = \left(\frac{N_2}{N_1}\right)^3 = (1.15)^3 = 1.520875 P 1 ​ P 2 ​ ​ = ( N 1 ​ N 2 ​ ​ ) 3 = ( 1.15 ) 3 = 1.520875 .

New shaft power: P shaft , 2 = 27.11 kW × 1.520875 = 41.23 kW P_{\text{shaft},2} = 27.11 \text{ kW} \times 1.520875 = 41.23 \text{ kW} P shaft , 2 ​ = 27.11 kW × 1.520875 = 41.23 kW

Step 4: Compute Compressible Flow Properties at (Ma = 1.60)

Temperature ratio: T 0 T = 1 + k − 1 2 M a 2 = 1 + 1.4 − 1 2 ( 1.60 ) 2 = 1 + 0.2 ( 2.56 ) = 1 + 0.512 = 1.512 \frac{T_0}{T} = 1 + \frac{k-1}{2} Ma^2 = 1 + \frac{1.4-1}{2} (1.60)^2 = 1 + 0.2(2.56) = 1 + 0.512 = 1.512 T T 0 ​ ​ = 1 + 2 k − 1 ​ M a 2 = 1 + 2 1.4 − 1 ​ ( 1.60 ) 2 = 1 + 0.2 ( 2.56 ) = 1 + 0.512 = 1.512 T = T 0 1.512 = 350 K 1.512 = 231.48 K T = \frac{T_0}{1.512} = \frac{350 \text{ K}}{1.512} = 231.48 \text{ K} T = 1.512 T 0 ​ ​ = 1.512 350 K ​ = 231.48 K

Static pressure ratio: P 0 P = ( T 0 T ) k k − 1 = ( 1.512 ) 1.4 0.4 = ( 1.512 ) 3.5 = 4.2504 \frac{P_0}{P} = \left(\frac{T_0}{T}\right)^{\frac{k}{k-1}} = (1.512)^{\frac{1.4}{0.4}} = (1.512)^{3.5} = 4.2504 P P 0 ​ ​ = ( T T 0 ​ ​ ) k − 1 k ​ = ( 1.512 ) 0.4 1.4 ​ = ( 1.512 ) 3.5 = 4.2504 P = P 0 4.2504 = 400 kPa 4.2504 = 94.11 kPa P = \frac{P_0}{4.2504} = \frac{400 \text{ kPa}}{4.2504} = 94.11 \text{ kPa} P = 4.2504 P 0 ​ ​ = 4.2504 400 kPa ​ = 94.11 kPa

Local speed of sound: c = k R T = 1.4 × 287 × 231.48 = 92 , 999 = 304.96 m/s c = \sqrt{k R T} = \sqrt{1.4 \times 287 \times 231.48} = \sqrt{92,999} = 304.96 \text{ m/s} c = k RT ​ = 1.4 × 287 × 231.48 ​ = 92 , 999 ​ = 304.96 m/s

Flow velocity: V = M a ⋅ c = 1.60 × 304.96 m/s = 487.94 m/s V = Ma \cdot c = 1.60 \times 304.96 \text{ m/s} = 487.94 \text{ m/s} V = M a ⋅ c = 1.60 × 304.96 m/s = 487.94 m/s

Final Answer: N P S H A = 6.39 m NPSHA = 6.39 \text{ m} NPS H A = 6.39 m , initial shaft power P shaft = 27.11 kW P_{\text{shaft}} = 27.11 \text{ kW} P shaft ​ = 27.11 kW , speed-scaled shaft power P shaft , 2 = 41.23 kW P_{\text{shaft},2} = 41.23 \text{ kW} P shaft , 2 ​ = 41.23 kW , and compressible flow parameters T = 231.5 K T = 231.5 \text{ K} T = 231.5 K , P = 94.11 kPa P = 94.11 \text{ kPa} P = 94.11 kPa , V = 487.9 m/s V = 487.9 \text{ m/s} V = 487.9 m/s .