Study guide
14.6 Combustion and Combustion Products
FE Other Disciplines Fundamentals of Engineering
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Strategy
About the FE Other Disciplines Exam How to Use This Study Guide
2 Chapter 1: Mathematics
1.1 Analytic Geometry, Trigonometry, and Vector Operations 1.2 Differential and Integral Calculus 1.3 Ordinary Differential Equations and Laplace Transforms 1.4 Linear Algebra, Matrices, and Systems of Equations 1.5 Numerical Methods, Root-Finding, and Numerical Integration
3 Chapter 2: Probability and Statistics
2.1 Probability Distributions, PMFs, and PDFs 2.2 Expected Value, Mean, Variance, and Descriptive Statistics 2.3 Estimation, Confidence Intervals, and Sample Sizes 2.4 Hypothesis Testing, Goodness of Fit, and Linear Regression
4 Chapter 3: Chemistry
3.1 Stoichiometry, Chemical Reactions, and Solutions 3.2 Chemical Equilibrium, Acids/Bases, and Ideal Gas Laws 3.3 Oxidation-Reduction, Electrochemistry, and Corrosion Basics
5 Chapter 4: Instrumentation and Controls
4.1 Sensors, Transducers, and Signal Conditioning 4.2 Data Sampling, Accuracy/Precision, and A/D Conversion 4.3 Logic Diagrams, Boolean Algebra, and Control Logic
6 Chapter 5: Engineering Ethics and Societal Impacts
5.1 NCEES Model Rules of Professional Conduct and Codes of Ethics 5.2 Public Protection, Licensure Boards, and Professional Liability 5.3 Societal Impacts: Sustainability, Life-Cycle Analysis, and Public Safety
7 Chapter 6: Safety, Health, and Environment
6.1 OSHA Regulations, Industrial Hygiene, and PPE 6.2 Hazard Assessment, Risk Management, and Environmental Rules 6.3 Gas Detection and Monitoring 6.4 Electrical Safety 6.5 Confined Space Entry and Ventilation Rates
8 Chapter 7: Engineering Economics
7.1 Time Value of Money, Interest Formulas, and Cash Flow Diagrams 7.2 Capital Budgeting: Present Worth, Annual Worth, IRR, and B/C Ratio 7.3 Depreciation Methods, Income Taxes, and Breakeven Analysis 7.4 Cost Analysis, Uncertainty, Expected Value, and Decision Trees
9 Chapter 8: Statics
8.1 Statics Equilibrium, Free-Body Diagrams, and Force Systems 8.2 Distributed Loads, Resultants, and Equivalent Force-Couple Systems 8.3 Internal Forces in Rigid Bodies: Trusses, Frames, Machines, and Friction 8.4 Three-Dimensional Equilibrium, Cables, and Pulley Systems 8.5 Area Properties: Centroids, Moments of Inertia, and Radius of Gyration 8.6 Weight, Mass, and Force Units: slug, lbm, lbf, and g_c
10 Chapter 9: Dynamics
9.1 Kinematics of Particles and Rigid Bodies 9.2 Newton's Second Law for Particles and Rigid Bodies 9.3 Angular Motion, Torque, and Mass Moment of Inertia 9.4 Work-Energy Principle, Power, and Efficiency 9.5 Impulse-Momentum, Impact, and Coefficient of Restitution 9.6 Dynamic Friction and Vibrations: Natural Frequency and Damping
11 Chapter 10: Strength of Materials
10.1 Stress Types, Axial Stress-Strain, and Thermal Deformation 10.2 Torsion of Circular Shafts, Polar Moment, and Angle of Twist 10.3 Shear and Moment Diagrams 10.4 Flexural Bending Stress and Transverse Shear Stress 10.5 Stress Transformations, Principal Stresses, and Mohr's Circle 10.6 Beam Deflections and Combined Axial/Bending Loading 10.7 Column Buckling (Euler Formula) and Yield/Failure Criteria
12 Chapter 11: Materials
11.1 Crystal Structure, Phase Diagrams, and Material Processing 11.2 Mechanical Properties, Fatigue, Fracture, and Corrosion 11.3 Thermal Properties of Materials 11.4 Electrical and Chemical Properties of Materials 11.5 Material Selection for Engineering Design
13 Chapter 12: Fluid Mechanics
12.1 Fluid Properties, Hydrostatic Pressure, and Manometry 12.2 Dimensionless Numbers and Flow Regimes 12.3 Continuity Equation, Bernoulli Equation, and Energy Equation 12.4 Impulse-Momentum Equation and Forces on Control Volumes 12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses 12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors 12.7 Open-Channel Flow, Manning's Equation, and Drag 12.8 Fluid Transport Systems and Flow Measurement 12.9 Ideal Gas Law, Gas Mixtures, and the Real Gas Law
14 Chapter 13: Basic Electrical Engineering
13.1 Electrical Fundamentals, Ohm's Law, and DC Circuits 13.2 AC Circuits, Phasors, Impedance, and Three-Phase Power 13.3 Magnetic Fields, Induction, Transformers, and Motor Efficiency 13.4 Electrical Measuring Devices: Voltmeter, Ammeter, and Wattmeter
15 Chapter 14: Thermodynamics and Heat Transfer
14.1 First & Second Laws of Thermodynamics and Pure Substance Properties 14.2 Thermodynamic Processes and Property Diagrams (T-s, P-h, P-v) 14.3 Heat Transfer: Conduction, Convection, and Radiation 14.4 Ideal Gas Processes and Power/Refrigeration Cycles 14.5 Mass and Energy Balances on Control Volumes 14.6 Combustion and Combustion Products 14.7 Psychrometrics: Relative Humidity, Wet-Bulb Temperature, and the Psychrometric Chart
14.6 Combustion and Combustion Products
Key Takeaways Explain This Topic AI
NCEES names combustion and combustion products explicitly, listing CO, CO2, NOx, ash, and particulates.
Air is 21% oxygen and 79% nitrogen by volume, so each mole of oxygen is accompanied by 3.76 moles of nitrogen.
Theoretical or stoichiometric air is the exact amount needed for complete combustion to CO2 and H2O with no excess oxygen.
Excess air is supplied to ensure complete combustion, and its level is verified by measuring oxygen in the flue gas.
Carbon monoxide in the flue gas signals incomplete combustion, while thermal NOx forms from nitrogen and oxygen at high flame temperature rather than from the fuel.
Last updated: August 2026
14.6 Combustion and Combustion Products
NCEES lists "Combustion and combustion products (e.g., CO, CO₂, NOₓ, ash, particulates)" under Thermodynamics and Heat Transfer. Expect one balancing or air-fuel-ratio calculation and one conceptual item on which pollutant comes from where.
The Composition of Air
By volume (equivalently, by moles), dry air is 21% O₂ and 79% N₂. So per mole of oxygen: 79 21 = 3.76 moles of N 2 \frac{79}{21} = 3.76\ \text{moles of N}_2 21 79 = 3.76 moles of N 2 Air = O 2 + 3.76 N 2 (the working unit for every combustion equation) \text{Air} = \text{O}_2 + 3.76\,\text{N}_2 \qquad\text{(the working unit for every combustion equation)} Air = O 2 + 3.76 N 2 (the working unit for every combustion equation)
Molar masses: air 28.97, O₂ 32.00, N₂ 28.01, CO₂ 44.01, H₂O 18.02, CO 28.01, SO₂ 64.06 kg/kmol.
Nitrogen is inert but not irrelevant. It does not react (except in trace NOₓ formation), but it absorbs a large fraction of the released heat and leaves up the stack, which is why flue-gas heat loss is dominated by nitrogen and why oxygen-enriched combustion runs so much hotter.
Stoichiometric (Theoretical) Combustion
For a hydrocarbon C x H y \text{C}_x\text{H}_y C x H y burning completely in theoretical air: C x H y + a ( O 2 + 3.76 N 2 ) → x CO 2 + y 2 H 2 O + 3.76 a N 2 \text{C}_x\text{H}_y + a(\text{O}_2 + 3.76\,\text{N}_2) \rightarrow x\,\text{CO}_2 + \frac{y}{2}\text{H}_2\text{O} + 3.76a\,\text{N}_2 C x H y + a ( O 2 + 3.76 N 2 ) → x CO 2 + 2 y H 2 O + 3.76 a N 2 a = x + y 4 a = x + \frac{y}{4} a = x + 4 y
Methane ( x = 1 x=1 x = 1 , y = 4 y=4 y = 4 , so a = 2 a = 2 a = 2 ): CH 4 + 2 ( O 2 + 3.76 N 2 ) → CO 2 + 2 H 2 O + 7.52 N 2 \text{CH}_4 + 2(\text{O}_2 + 3.76\,\text{N}_2) \rightarrow \text{CO}_2 + 2\,\text{H}_2\text{O} + 7.52\,\text{N}_2 CH 4 + 2 ( O 2 + 3.76 N 2 ) → CO 2 + 2 H 2 O + 7.52 N 2
Propane ( x = 3 x=3 x = 3 , y = 8 y=8 y = 8 , so a = 5 a = 5 a = 5 ): C 3 H 8 + 5 ( O 2 + 3.76 N 2 ) → 3 CO 2 + 4 H 2 O + 18.8 N 2 \text{C}_3\text{H}_8 + 5(\text{O}_2 + 3.76\,\text{N}_2) \rightarrow 3\,\text{CO}_2 + 4\,\text{H}_2\text{O} + 18.8\,\text{N}_2 C 3 H 8 + 5 ( O 2 + 3.76 N 2 ) → 3 CO 2 + 4 H 2 O + 18.8 N 2
Air-Fuel Ratio A F R mass = m air m fuel = a ( 4.76 ) ( 28.97 ) M fuel AFR_{\text{mass}} = \frac{m_{\text{air}}}{m_{\text{fuel}}} = \frac{a(4.76)(28.97)}{M_{\text{fuel}}} A F R mass = m fuel m air = M fuel a ( 4.76 ) ( 28.97 )
- Fuel Stoichiometric AFR (mass)
- Methane (CH₄) 17.2
- Propane (C₃H₈) 15.7
- Gasoline (≈C₈H₁₈) 14.7
- Hydrogen 34.3
- Carbon 11.5
The equivalence ratio ϕ \phi ϕ compares actual fuel to stoichiometric fuel: ϕ = A F R stoich A F R actual \phi = \frac{AFR_{\text{stoich}}}{AFR_{\text{actual}}} ϕ = A F R actual A F R stoich
ϕ > 1 \phi > 1 ϕ > 1 is fuel-rich (produces CO and soot); ϕ < 1 \phi < 1 ϕ < 1 is fuel-lean (excess oxygen in the products); ϕ = 1 \phi = 1 ϕ = 1 is stoichiometric.
Excess Air % excess air = a actual − a theoretical a theoretical × 100 % \%\text{ excess air} = \frac{a_{\text{actual}} - a_{\text{theoretical}}}{a_{\text{theoretical}}}\times100\% % excess air = a theoretical a actual − a theoretical × 100%
With e e e as the fractional excess air, the reaction becomes: C x H y + ( 1 + e ) a ( O 2 + 3.76 N 2 ) → x CO 2 + y 2 H 2 O + e a O 2 + 3.76 ( 1 + e ) a N 2 \text{C}_x\text{H}_y + (1+e)a(\text{O}_2+3.76\,\text{N}_2) \rightarrow x\,\text{CO}_2 + \frac{y}{2}\text{H}_2\text{O} + e\,a\,\text{O}_2 + 3.76(1+e)a\,\text{N}_2 C x H y + ( 1 + e ) a ( O 2 + 3.76 N 2 ) → x CO 2 + 2 y H 2 O + e a O 2 + 3.76 ( 1 + e ) a N 2
Excess air appears as O₂ in the products — which is precisely how it is measured in practice. A flue-gas oxygen analyzer is the standard combustion-tuning instrument, and the relationship between flue O₂ and excess air is the reason:
- Flue gas O₂ (dry) Approximate excess air
- 1% ~5%
- 2% ~10%
- 3% ~15%
- 5% ~28%
- 7% ~45%
The optimization trade-off. Too little excess air produces CO and unburned fuel — a safety hazard and an efficiency loss. Too much excess air carries heat up the stack as hot nitrogen and oxygen, wasting fuel. Typical practice is 10–20% excess air for gas and 20–30% for solid fuels. Efficiency is maximized just above the CO breakthrough point, which is why the tuning target is stated as a flue O₂ percentage.
Worked Example: Excess Air Combustion of Propane
Propane burns with 25% excess air. Write the balanced equation and find the air-fuel ratio and the dry volumetric CO₂ percentage.
Theoretical a = 5 a = 5 a = 5 ; actual = 1.25 ( 5 ) = 6.25 = 1.25(5) = 6.25 = 1.25 ( 5 ) = 6.25 . C 3 H 8 + 6.25 ( O 2 + 3.76 N 2 ) → 3 CO 2 + 4 H 2 O + 1.25 O 2 + 23.5 N 2 \text{C}_3\text{H}_8 + 6.25(\text{O}_2+3.76\,\text{N}_2) \rightarrow 3\,\text{CO}_2 + 4\,\text{H}_2\text{O} + 1.25\,\text{O}_2 + 23.5\,\text{N}_2 C 3 H 8 + 6.25 ( O 2 + 3.76 N 2 ) → 3 CO 2 + 4 H 2 O + 1.25 O 2 + 23.5 N 2
Check oxygen: supplied = 6.25 ( 2 ) = 12.5 = 6.25(2) = 12.5 = 6.25 ( 2 ) = 12.5 atoms; used = 3 ( 2 ) + 4 ( 1 ) = 10 = 3(2) + 4(1) = 10 = 3 ( 2 ) + 4 ( 1 ) = 10 ; excess = 2.5 = 2.5 = 2.5 atoms = 1.25 = 1.25 = 1.25 mol O₂ ✓
Air-fuel ratio by mass: m air = 6.25 ( 4.76 ) ( 28.97 ) = 861.6 kg , M C 3 H 8 = 3 ( 12.01 ) + 8 ( 1.008 ) = 44.09 m_{\text{air}} = 6.25(4.76)(28.97) = 861.6\ \text{kg}, \qquad M_{\text{C}_3\text{H}_8} = 3(12.01)+8(1.008) = 44.09 m air = 6.25 ( 4.76 ) ( 28.97 ) = 861.6 kg , M C 3 H 8 = 3 ( 12.01 ) + 8 ( 1.008 ) = 44.09 A F R = 861.6 44.09 = 19.5 kg air/kg fuel AFR = \frac{861.6}{44.09} = \boxed{19.5\ \text{kg air/kg fuel}} A FR = 44.09 861.6 = 19.5 kg air/kg fuel
Confirm against the stoichiometric value: 15.7 × 1.25 = 19.6 15.7 \times 1.25 = 19.6 15.7 × 1.25 = 19.6 ✓
Dry product analysis (excluding H₂O, as flue-gas analyzers report): n dry = 3 + 1.25 + 23.5 = 27.75 mol n_{\text{dry}} = 3 + 1.25 + 23.5 = 27.75\ \text{mol} n dry = 3 + 1.25 + 23.5 = 27.75 mol % CO 2 = 3 27.75 = 10.8 % , % O 2 = 1.25 27.75 = 4.5 % \%\text{CO}_2 = \frac{3}{27.75} = 10.8\%, \qquad \%\text{O}_2 = \frac{1.25}{27.75} = 4.5\% % CO 2 = 27.75 3 = 10.8% , % O 2 = 27.75 1.25 = 4.5%
The 4.5% flue oxygen is exactly what an analyzer would read to confirm 25% excess air.
Dew point of the products. The wet total is 27.75 + 4 = 31.75 27.75 + 4 = 31.75 27.75 + 4 = 31.75 mol, so the water mole fraction is 4 / 31.75 = 0.126 4/31.75 = 0.126 4/31.75 = 0.126 . At 101.3 kPa the water partial pressure is 0.126 ( 101.3 ) = 12.8 0.126(101.3) = 12.8 0.126 ( 101.3 ) = 12.8 kPa, whose saturation temperature is about 51 °C .
Why the dew point matters: cooling flue gas below ~51 °C condenses water in the stack. For sulfur-bearing fuels the acid dew point is far higher (120–150 °C) because SO₃ forms sulfuric acid, which is why conventional boilers keep stack temperatures well above it and why condensing boilers require corrosion-resistant materials.
Combustion Products and Their Origins
- Product Origin Control
- CO₂ Complete oxidation of fuel carbon Only by using less carbon-intensive fuel or less fuel
- H₂O Oxidation of fuel hydrogen Not controlled; recoverable as latent heat in condensing equipment
CO Incomplete combustion — insufficient air, poor mixing, or flame quenching More excess air, better mixing, longer residence time
Unburned hydrocarbons / soot Fuel-rich zones, flame impingement Same as CO
Thermal NOₓ N₂ from the air reacting with O₂ at high flame temperature Lower peak temperature — flue gas recirculation, staged combustion, low-NOₓ burners, water/steam injection
- Fuel NOₓ Nitrogen chemically bound in the fuel (coal, heavy oil) Fuel switching; staged combustion
- SOₓ Sulfur in the fuel Fuel desulfurization; flue gas desulfurization (scrubbing)
- Ash Incombustible mineral matter in solid fuels Bottom ash removal; fly ash captured by ESP or baghouse
- Particulates (PM) Ash, soot, condensed volatiles Electrostatic precipitator, baghouse, cyclone, wet scrubber
The central asymmetry, and a favorite exam item. CO and NOₓ respond in opposite directions to the same lever. Raising flame temperature and excess air burns out CO but increases thermal NOₓ; lowering peak temperature suppresses NOₓ but risks CO breakthrough. This is why combustion tuning is a genuine optimization rather than a maximization, and why low-NOₓ burners must be carefully commissioned against CO limits.
Note also that thermal NOₓ nitrogen comes from the combustion air, not the fuel — so burning a nitrogen-free fuel such as pure methane or hydrogen in air still produces NOₓ. Only the flame temperature controls it.