Study guide
4.1 Sensors, Transducers, and Signal Conditioning
FE Other Disciplines Fundamentals of Engineering
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Strategy
About the FE Other Disciplines Exam How to Use This Study Guide
2 Chapter 1: Mathematics
1.1 Analytic Geometry, Trigonometry, and Vector Operations 1.2 Differential and Integral Calculus 1.3 Ordinary Differential Equations and Laplace Transforms 1.4 Linear Algebra, Matrices, and Systems of Equations 1.5 Numerical Methods, Root-Finding, and Numerical Integration
3 Chapter 2: Probability and Statistics
2.1 Probability Distributions, PMFs, and PDFs 2.2 Expected Value, Mean, Variance, and Descriptive Statistics 2.3 Estimation, Confidence Intervals, and Sample Sizes 2.4 Hypothesis Testing, Goodness of Fit, and Linear Regression
4 Chapter 3: Chemistry
3.1 Stoichiometry, Chemical Reactions, and Solutions 3.2 Chemical Equilibrium, Acids/Bases, and Ideal Gas Laws 3.3 Oxidation-Reduction, Electrochemistry, and Corrosion Basics
5 Chapter 4: Instrumentation and Controls
4.1 Sensors, Transducers, and Signal Conditioning 4.2 Data Sampling, Accuracy/Precision, and A/D Conversion 4.3 Logic Diagrams, Boolean Algebra, and Control Logic
6 Chapter 5: Engineering Ethics and Societal Impacts
5.1 NCEES Model Rules of Professional Conduct and Codes of Ethics 5.2 Public Protection, Licensure Boards, and Professional Liability 5.3 Societal Impacts: Sustainability, Life-Cycle Analysis, and Public Safety
7 Chapter 6: Safety, Health, and Environment
6.1 OSHA Regulations, Industrial Hygiene, and PPE 6.2 Hazard Assessment, Risk Management, and Environmental Rules 6.3 Gas Detection and Monitoring 6.4 Electrical Safety 6.5 Confined Space Entry and Ventilation Rates
8 Chapter 7: Engineering Economics
7.1 Time Value of Money, Interest Formulas, and Cash Flow Diagrams 7.2 Capital Budgeting: Present Worth, Annual Worth, IRR, and B/C Ratio 7.3 Depreciation Methods, Income Taxes, and Breakeven Analysis 7.4 Cost Analysis, Uncertainty, Expected Value, and Decision Trees
9 Chapter 8: Statics
8.1 Statics Equilibrium, Free-Body Diagrams, and Force Systems 8.2 Distributed Loads, Resultants, and Equivalent Force-Couple Systems 8.3 Internal Forces in Rigid Bodies: Trusses, Frames, Machines, and Friction 8.4 Three-Dimensional Equilibrium, Cables, and Pulley Systems 8.5 Area Properties: Centroids, Moments of Inertia, and Radius of Gyration 8.6 Weight, Mass, and Force Units: slug, lbm, lbf, and g_c
10 Chapter 9: Dynamics
9.1 Kinematics of Particles and Rigid Bodies 9.2 Newton's Second Law for Particles and Rigid Bodies 9.3 Angular Motion, Torque, and Mass Moment of Inertia 9.4 Work-Energy Principle, Power, and Efficiency 9.5 Impulse-Momentum, Impact, and Coefficient of Restitution 9.6 Dynamic Friction and Vibrations: Natural Frequency and Damping
11 Chapter 10: Strength of Materials
10.1 Stress Types, Axial Stress-Strain, and Thermal Deformation 10.2 Torsion of Circular Shafts, Polar Moment, and Angle of Twist 10.3 Shear and Moment Diagrams 10.4 Flexural Bending Stress and Transverse Shear Stress 10.5 Stress Transformations, Principal Stresses, and Mohr's Circle 10.6 Beam Deflections and Combined Axial/Bending Loading 10.7 Column Buckling (Euler Formula) and Yield/Failure Criteria
12 Chapter 11: Materials
11.1 Crystal Structure, Phase Diagrams, and Material Processing 11.2 Mechanical Properties, Fatigue, Fracture, and Corrosion 11.3 Thermal Properties of Materials 11.4 Electrical and Chemical Properties of Materials 11.5 Material Selection for Engineering Design
13 Chapter 12: Fluid Mechanics
12.1 Fluid Properties, Hydrostatic Pressure, and Manometry 12.2 Dimensionless Numbers and Flow Regimes 12.3 Continuity Equation, Bernoulli Equation, and Energy Equation 12.4 Impulse-Momentum Equation and Forces on Control Volumes 12.5 Flow in Pipes, Friction Factors (Moody Diagram), and Head Losses 12.6 Turbomachinery: Pumps, Turbines, Fans, and Compressors 12.7 Open-Channel Flow, Manning's Equation, and Drag 12.8 Fluid Transport Systems and Flow Measurement 12.9 Ideal Gas Law, Gas Mixtures, and the Real Gas Law
14 Chapter 13: Basic Electrical Engineering
13.1 Electrical Fundamentals, Ohm's Law, and DC Circuits 13.2 AC Circuits, Phasors, Impedance, and Three-Phase Power 13.3 Magnetic Fields, Induction, Transformers, and Motor Efficiency 13.4 Electrical Measuring Devices: Voltmeter, Ammeter, and Wattmeter
15 Chapter 14: Thermodynamics and Heat Transfer
14.1 First & Second Laws of Thermodynamics and Pure Substance Properties 14.2 Thermodynamic Processes and Property Diagrams (T-s, P-h, P-v) 14.3 Heat Transfer: Conduction, Convection, and Radiation 14.4 Ideal Gas Processes and Power/Refrigeration Cycles 14.5 Mass and Energy Balances on Control Volumes 14.6 Combustion and Combustion Products 14.7 Psychrometrics: Relative Humidity, Wet-Bulb Temperature, and the Psychrometric Chart
4.1 Sensors, Transducers, and Signal Conditioning
Key Takeaways Explain This Topic AI
Active transducers generate an electrical output directly from physical stimuli without external power, whereas passive transducers require external excitation voltage.
Wheatstone bridge circuits convert small fractional resistance changes from strain gauges into measurable voltage signals, with full-bridge arrangements maximizing output sensitivity and providing intrinsic temperature compensation.
Resistance Temperature Detectors (RTDs) offer superior linearity and stability using Pt100 platinum elements with lead-wire compensation (3-wire or 4-wire), while thermocouples leverage the Seebeck effect for extreme temperature ranges.
Operational amplifiers serve as the foundation of signal conditioning; instrumentation amplifiers provide high input impedance and high common-mode rejection ratio (CMRR) necessary for amplifying microvolt-level bridge signals.
First-order active and passive RC filters establish specific cutoff frequencies (f_c = 1 / (2πRC)) to attenuate high-frequency noise and prevent aliasing prior to analog-to-digital conversion.
Last updated: August 2026
4.1 Sensors, Transducers, and Signal Conditioning
Core Concept: Instrumentation systems convert physical engineering variables (temperature, pressure, strain, displacement, acceleration) into calibrated, noise-free electrical signals suitable for digital processing. Understanding transducer operation, bridge circuits, and op-amp signal conditioning is essential for NCEES FE exam success.
Classification of Transducers & Sensors
A transducer is any device that converts energy from one form to another. A sensor is a specific type of transducer that detects a physical parameter and converts it into a readable signal (voltage, current, or resistance).
Transducer Category Operating Mechanism Key Characteristics Common Examples
Active (Self-Generating) Produces electrical output directly from physical stimulus; requires no external power supply. High dynamic response; no excitation voltage required. Thermocouples (Seebeck effect), Piezoelectric accelerometers, Photovoltaic cells
Passive (Variable Parameter) Alters electrical impedance (resistance, capacitance, inductance) in response to stimulus; requires external excitation. Highly accurate; requires stable power supply and bridge circuits. Strain gauges (piezoresistive), RTDs, Thermistors, LVDTs (inductive), Capacitive pressure sensors
Critical Sensor Performance Parameters
Sensitivity ( S S S ): The ratio of change in electrical output ( Δ Y \Delta Y Δ Y ) to the change in physical input ( Δ X \Delta X Δ X ): S = d Y d X S = \frac{dY}{dX} S = d X d Y
Linearity: The degree to which the calibration curve conforms to a straight line over a specified operating range.
Hysteresis: The maximum difference in output readings for a given input when approached from increasing versus decreasing directions.
Response Time / Time Constant ( τ \tau τ ): The time required for a first-order sensor output to reach 63.2 % 63.2\% 63.2% of its final steady-state value following a step input change.
Loading diagram... Complete Sensor Signal Conditioning Pipeline
- Strain Gauges and Wheatstone Bridge Circuits
- Strain Gauge Operating Principle
Metallic foil strain gauges operate on the piezoresistive effect : stretching or compressing a thin conductive wire alters its electrical resistance. The relationship between fractional resistance change ( Δ R / R 0 ) (\Delta R / R_0) ( Δ R / R 0 ) and mechanical strain ( ϵ = Δ L / L 0 ) (\epsilon = \Delta L / L_0) ( ϵ = Δ L / L 0 ) is defined by the Gauge Factor ( G F GF GF ): Gauge Factor ( G F ) = Δ R / R 0 ϵ ⟹ Δ R R 0 = G F ⋅ ϵ \text{Gauge Factor } (GF) = \frac{\Delta R / R_0}{\epsilon} \implies \frac{\Delta R}{R_0} = GF \cdot \epsilon Gauge Factor ( GF ) = ϵ Δ R / R 0 ⟹ R 0 Δ R = GF ⋅ ϵ
For standard metallic foil strain gauges (typically constantan alloy), G F ≈ 2.0 GF \approx 2.0 GF ≈ 2.0 , and nominal unstrained resistance R 0 = 120 , Ω R_0 = 120\\,\Omega R 0 = 120 , Ω or 350 , Ω 350\\,\Omega 350 , Ω .
Wheatstone Bridge Configurations
Because fractional resistance changes are extremely small (typically μ Ω \mu\Omega μ Ω to m Ω m\Omega m Ω ), a Wheatstone bridge circuit is required to convert resistance changes into measurable output voltage changes. +V_in (Excitation)
- |
- +----+----+
- | |
- [R1] [R2]
- | |
- +-- A +-- B --> V_out = V_A - V_B
- | |
- [R4] [R3]
- | |
- +----+----+
- |
- GND
The general voltage output equation for a Wheatstone bridge excited by V i n V_{in} V in is: V o u t = V i n ( R 3 R 3 + R 2 − R 4 R 1 + R 4 ) V_{out} = V_{in} \left( \frac{R_3}{R_3 + R_2} - \frac{R_4}{R_1 + R_4} \right) V o u t = V in ( R 3 + R 2 R 3 − R 1 + R 4 R 4 )
The bridge is balanced ( V o u t = 0 V_{out} = 0 V o u t = 0 ) when: R 1 R 3 = R 2 R 4 R_1 R_3 = R_2 R_4 R 1 R 3 = R 2 R 4
Bridge Sensitivity Comparison
Bridge Type Active Gauges Arrangement & Application Approximate Output Voltage Formula
Quarter-Bridge 1 Gauge ( R 1 = R 0 + Δ R R_1 = R_0 + \Delta R R 1 = R 0 + Δ R ) Uniaxial strain measurement. High temperature sensitivity. V o u t ≈ V i n 4 ⋅ G F ⋅ ϵ V_{out} \approx \frac{V_{in}}{4} \cdot GF \cdot \epsilon V o u t ≈ 4 V in ⋅ GF ⋅ ϵ
Half-Bridge 2 Gauges ( R 1 , R 2 R_1, R_2 R 1 , R 2 ) Bending strain ( R 1 R_1 R 1 in tension, R 2 R_2 R 2 in compression) OR active gauge + dummy gauge for temperature compensation. V o u t ≈ V i n 2 ⋅ G F ⋅ ϵ V_{out} \approx \frac{V_{in}}{2} \cdot GF \cdot \epsilon V o u t ≈ 2 V in ⋅ GF ⋅ ϵ
Full-Bridge 4 Gauges ( R 1 , R 3 R_1, R_3 R 1 , R 3 tension, R 2 , R 4 R_2, R_4 R 2 , R 4 compression) Maximum output sensitivity; complete intrinsic temperature cancellation; immune to lead resistance. V o u t = V i n ⋅ G F ⋅ ϵ V_{out} = V_{in} \cdot GF \cdot \epsilon V o u t = V in ⋅ GF ⋅ ϵ
Temperature Compensation Tip: Temperature expansion causes non-strain resistance drift. In a half-bridge, placing an inactive "dummy gauge" on an unstrained block of identical material in the adjacent bridge arm cancels thermal drift automatically because both arms experience identical thermal Δ R \Delta R Δ R .
Temperature Measurement Transducers: Thermocouples vs. RTDs
Temperature is among the most frequently measured parameters in engineering exams. NCEES tests your ability to distinguish between thermoelectric devices and resistive detectors.
Thermocouples (Seebeck Effect)
A thermocouple consists of two dissimilar conductor wires joined at two junctions. When a temperature gradient exists between the measuring (hot) junction ( T h o t T_{hot} T h o t ) and the reference (cold) junction ( T r e f T_{ref} T re f ), an electromotive force (EMF) is generated proportionally: V e m f = S ⋅ ( T h o t − T r e f ) V_{emf} = S \cdot (T_{hot} - T_{ref}) V e m f = S ⋅ ( T h o t − T re f )
where S S S is the Seebeck coefficient ( μ V / ∘ C ) (\mu\text{V}/^\circ\text{C}) ( μ V / ∘ C ) .
Cold Junction Compensation (CJC): Modern instruments measure T r e f T_{ref} T re f using an isothermal block and add the corresponding voltage electronically.
Standard Types:
Type K (Chromel-Alumel): Most popular general-purpose ( S ≈ 41 , μ V / ∘ C S \approx 41\\,\mu\text{V}/^\circ\text{C} S ≈ 41 , μ V / ∘ C , range − 200 ∘ C -200^\circ\text{C} − 20 0 ∘ C to + 1250 ∘ C +1250^\circ\text{C} + 125 0 ∘ C ).
Type J (Iron-Constantan): High sensitivity, reducing atmosphere ( S ≈ 52 , μ V / ∘ C S \approx 52\\,\mu\text{V}/^\circ\text{C} S ≈ 52 , μ V / ∘ C , up to 750 ∘ C 750^\circ\text{C} 75 0 ∘ C ).
Type T (Copper-Constantan): High precision for cryogenic applications ( − 200 ∘ C -200^\circ\text{C} − 20 0 ∘ C to + 350 ∘ C +350^\circ\text{C} + 35 0 ∘ C ).
Resistance Temperature Detectors (RTDs)
RTDs exploit the positive temperature coefficient of metals (most commonly platinum). Over standard operating ranges, resistance increases linearly with temperature according to the Callendar-Van Dusen equation (linear approximation): R ( T ) = R 0 [ 1 + α ( T − T 0 ) ] R(T) = R_0 \left[ 1 + \alpha (T - T_0) \right] R ( T ) = R 0 [ 1 + α ( T − T 0 ) ]
Pt100 Standard: Platinum RTD with nominal resistance R 0 = 100.0 , Ω R_0 = 100.0\\,\Omega R 0 = 100.0 , Ω at T 0 = 0 ∘ C T_0 = 0^\circ\text{C} T 0 = 0 ∘ C and temperature coefficient α = 0.00385 , ∘ C − 1 \alpha = 0.00385\\,^\circ\text{C}^{-1} α = 0.00385 , ∘ C − 1 (or Ω / Ω / ∘ C \Omega/\Omega/^\circ\text{C} Ω/Ω / ∘ C ).
Lead-Wire Compensation: Long extension wire resistance R w R_w R w introduces measurement error.
2-Wire: Uncompensated (adds 2 R w 2 R_w 2 R w directly to RTD resistance).
3-Wire: Standard industrial bridge connection; cancels equal lead resistance R w R_w R w in adjacent bridge arms.
4-Wire (Kelvin Sensing): Precision current source drives current through two outer leads while a high-impedance voltmeter measures voltage drop across two inner leads, completely eliminating R w R_w R w errors.
Sensor Type Principle Sensitivity Linearity Range Cost
Thermocouple Seebeck EMF Low ( 10 – 50 , μ V / ∘ C 10\text{--}50\\,\mu\text{V}/^\circ\text{C} 10 – 50 , μ V / ∘ C ) Non-linear (needs LUT) Very Wide ( − 200 to 1800 ∘ C -200\text{ to }1800^\circ\text{C} − 200 to 180 0 ∘ C ) Low
RTD (Pt100) Resistance change Medium ( 0.385 , Ω / ∘ C 0.385\\,\Omega/^\circ\text{C} 0.385 , Ω / ∘ C ) Excellent Linear Moderate ( − 200 to 850 ∘ C -200\text{ to }850^\circ\text{C} − 200 to 85 0 ∘ C ) Moderate
Thermistor Semiconductor NTC High ( − 4 % to − 6 % / ∘ C -4\% \text{ to } -6\% / ^\circ\text{C} − 4% to − 6% / ∘ C ) Highly Exponential Narrow ( − 50 to 150 ∘ C -50\text{ to }150^\circ\text{C} − 50 to 15 0 ∘ C ) Very Low
Signal Conditioning & Operational Amplifiers
Raw sensor outputs (microvolts or millivolts) are too weak for direct digitization by Analog-to-Digital Converters (ADCs). Signal conditioning provides amplification, filtering, level shifting, and impedance matching.
Ideal Operational Amplifier (Op-Amp) Golden Rules
For an ideal op-amp operating under negative feedback:
Zero Input Current: I + = I − = 0 I_+ = I_- = 0 I + = I − = 0 (Infinite input impedance Z i n = ∞ Z_{in} = \infty Z in = ∞ ).
Virtual Short: V + = V − V_+ = V_- V + = V − (The op-amp continuously adjusts output voltage V o u t V_{out} V o u t to hold the differential input voltage at zero). Inverting Amplifier Non-Inverting Amplifier
- R_f R_f
- +--[ ]--+ +--[ ]--+
- | | | |
- Vin-+- [R_in] -+-(-) -+-(-) |
- |--- Vout |--- Vout
- GND-+(+) Vin-+(+)
- Core Op-Amp Circuit Gain Formulas
Inverting Amplifier: V o u t = − ( R f R i n ) V i n ⟹ A v = − R f R i n V_{out} = -\left(\frac{R_f}{R_{in}}\right) V_{in} \implies A_v = -\frac{R_f}{R_{in}} V o u t = − ( R in R f ) V in ⟹ A v = − R in R f
Non-Inverting Amplifier: V o u t = ( 1 + R f R i n ) V i n ⟹ A v = 1 + R f R i n V_{out} = \left(1 + \frac{R_f}{R_{in}}\right) V_{in} \implies A_v = 1 + \frac{R_f}{R_{in}} V o u t = ( 1 + R in R f ) V in ⟹ A v = 1 + R in R f
Differential (Difference) Amplifier: When matched such that R 3 / R 1 = R 4 / R 2 R_3/R_1 = R_4/R_2 R 3 / R 1 = R 4 / R 2 : V o u t = R 2 R 1 ( V 2 − V 1 ) V_{out} = \frac{R_2}{R_1} (V_2 - V_1) V o u t = R 1 R 2 ( V 2 − V 1 )
Instrumentation Amplifier (3 Op-Amp Topology): Provides ultra-high input impedance on both inputs and exceptional Common-Mode Rejection Ratio (CMRR) for strain gauge bridge amplification: A v = ( 1 + 2 R 1 R G ) ( R 3 R 2 ) A_v = \left(1 + \frac{2 R_1}{R_G}\right) \left(\frac{R_3}{R_2}\right) A v = ( 1 + R G 2 R 1 ) ( R 2 R 3 )
where R G R_G R G is the single external gain-setting resistor.
Passive & Active Analog Filters
Analog low-pass filters remove high-frequency noise prior to sampling.
First-Order Low-Pass RC Filter Cutoff Frequency ( f c f_c f c ): f c = 1 2 π R C f_c = \frac{1}{2\pi R C} f c = 2 π RC 1
Transfer Function Magnitude: ∣ H ( f ) ∣ = 1 1 + ( f f c ) 2 |H(f)| = \frac{1}{\sqrt{1 + \left(\frac{f}{f_c}\right)^2}} ∣ H ( f ) ∣ = 1 + ( f c f ) 2 1 At f = f c f = f_c f = f c , signal amplitude is attenuated by − 3 , dB -3\\,\text{dB} − 3 , dB (reduced to 1 / 2 ≈ 0.707 1/\sqrt{2} \approx 0.707 1/ 2 ≈ 0.707 of its passband value).
- Worked Engineering Examples: Sensors & Conditioning
- Problem 1: Strain Gauge Bridge & Instrumentation Amplifier Design
Scenario: A structural steel member in a cantilever test frame is fitted with a quarter-bridge strain gauge ( R 0 = 120.0 , Ω R_0 = 120.0\\,\Omega R 0 = 120.0 , Ω , Gauge Factor G F = 2.05 GF = 2.05 GF = 2.05 ) powered by an excitation voltage V i n = 10.0 , V V_{in} = 10.0\\,\text{V} V in = 10.0 , V . Under peak structural load, the gauge measures a tensile strain of ϵ = 800 , μ ϵ \epsilon = 800\\,\mu\epsilon ϵ = 800 , μ ϵ ( 800 × 10 − 6 m/m 800 \times 10^{-6}\text{ m/m} 800 × 1 0 − 6 m/m ).
Calculate the resistance change Δ R \Delta R Δ R and unamplified Wheatstone bridge output voltage V o u t , b r i d g e V_{out,bridge} V o u t , b r i d g e .
Determine the amplifier gain A v A_v A v required to scale V o u t , b r i d g e V_{out,bridge} V o u t , b r i d g e to 2.05 , V 2.05\\,\text{V} 2.05 , V for an ADC input range.
If an instrumentation amplifier has matched internal resistors R 1 = 10.0 , k Ω R_1 = 10.0\\,\text{k}\Omega R 1 = 10.0 , k Ω and R 3 / R 2 = 1.0 R_3/R_2 = 1.0 R 3 / R 2 = 1.0 , calculate the required gain setting resistor R G R_G R G .
Solution:
Calculate Resistance Change and Bridge Voltage: Δ R = R 0 ⋅ G F ⋅ ϵ = 120.0 , Ω × 2.05 × ( 800 × 10 − 6 ) = 0.1968 , Ω \Delta R = R_0 \cdot GF \cdot \epsilon = 120.0\\,\Omega \times 2.05 \times (800 \times 10^{-6}) = 0.1968\\,\Omega Δ R = R 0 ⋅ GF ⋅ ϵ = 120.0 , Ω × 2.05 × ( 800 × 1 0 − 6 ) = 0.1968 , Ω V o u t , b r i d g e ≈ V i n 4 ⋅ G F ⋅ ϵ = 10.0 , V 4 × 2.05 × ( 800 × 10 − 6 ) = 4.10 × 10 − 3 , V = 4.10 , mV V_{out,bridge} \approx \frac{V_{in}}{4} \cdot GF \cdot \epsilon = \frac{10.0\\,\text{V}}{4} \times 2.05 \times (800 \times 10^{-6}) = 4.10 \times 10^{-3}\\,\text{V} = 4.10\\,\text{mV} V o u t , b r i d g e ≈ 4 V in ⋅ GF ⋅ ϵ = 4 10.0 , V × 2.05 × ( 800 × 1 0 − 6 ) = 4.10 × 1 0 − 3 , V = 4.10 , mV
Determine Required Voltage Gain: A v = V t a r g e t V o u t , b r i d g e = 2.05 , V 0.00410 , V = 500 A_v = \frac{V_{target}}{V_{out,bridge}} = \frac{2.05\\,\text{V}}{0.00410\\,\text{V}} = 500 A v = V o u t , b r i d g e V t a r g e t = 0.00410 , V 2.05 , V = 500
Calculate Gain Resistor R G R_G R G : A v = ( 1 + 2 R 1 R G ) ( 1.0 ) ⟹ 500 = 1 + 2 ( 10 , 000 , Ω ) R G A_v = \left(1 + \frac{2 R_1}{R_G}\right) (1.0) \implies 500 = 1 + \frac{2(10,000\\,\Omega)}{R_G} A v = ( 1 + R G 2 R 1 ) ( 1.0 ) ⟹ 500 = 1 + R G 2 ( 10 , 000 , Ω ) 499 = 20 , 000 R G ⟹ R G = 20 , 000 499 ≈ 40.08 , Ω 499 = \frac{20,000}{R_G} \implies R_G = \frac{20,000}{499} \approx 40.08\\,\Omega 499 = R G 20 , 000 ⟹ R G = 499 20 , 000 ≈ 40.08 , Ω
Problem 2: Pt100 RTD Temperature & Op-Amp Circuit Analysis
Scenario: A Pt100 platinum RTD ( R 0 = 100.0 , Ω R_0 = 100.0\\,\Omega R 0 = 100.0 , Ω at 0 ∘ C 0^\circ\text{C} 0 ∘ C , α = 0.00385 , ∘ C − 1 \alpha = 0.00385\\,^\circ\text{C}^{-1} α = 0.00385 , ∘ C − 1 ) is placed in an industrial vessel. The RTD's measured resistance is 138.50 , Ω 138.50\\,\Omega 138.50 , Ω .
Determine the temperature T T T inside the vessel.
The bridge output produces 50.0 , mV 50.0\\,\text{mV} 50.0 , mV which is fed into a non-inverting op-amp with R i n = 2.0 , k Ω R_{in} = 2.0\\,\text{k}\Omega R in = 2.0 , k Ω and R f = 38.0 , k Ω R_f = 38.0\\,\text{k}\Omega R f = 38.0 , k Ω . Calculate the op-amp output voltage V o u t V_{out} V o u t .
Solution:
Calculate Temperature T T T : R ( T ) = R 0 [ 1 + α T ] ⟹ 138.50 = 100.0 [ 1 + 0.00385 T ] R(T) = R_0 [1 + \alpha T] \implies 138.50 = 100.0 [1 + 0.00385 T] R ( T ) = R 0 [ 1 + α T ] ⟹ 138.50 = 100.0 [ 1 + 0.00385 T ] 1.3850 = 1 + 0.00385 T ⟹ 0.3850 = 0.00385 T ⟹ T = 0.3850 0.00385 = 100.0 ∘ C 1.3850 = 1 + 0.00385 T \implies 0.3850 = 0.00385 T \implies T = \frac{0.3850}{0.00385} = 100.0^\circ\text{C} 1.3850 = 1 + 0.00385 T ⟹ 0.3850 = 0.00385 T ⟹ T = 0.00385 0.3850 = 100. 0 ∘ C
Calculate Non-Inverting Op-Amp Output: A v = 1 + R f R i n = 1 + 38.0 , k Ω 2.0 , k Ω = 1 + 19 = 20 A_v = 1 + \frac{R_f}{R_{in}} = 1 + \frac{38.0\\,\text{k}\Omega}{2.0\\,\text{k}\Omega} = 1 + 19 = 20 A v = 1 + R in R f = 1 + 2.0 , k Ω 38.0 , k Ω = 1 + 19 = 20 V o u t = A v ⋅ V i n = 20 × 50.0 , mV = 1000 , mV = 1.00 , V V_{out} = A_v \cdot V_{in} = 20 \times 50.0\\,\text{mV} = 1000\\,\text{mV} = 1.00\\,\text{V} V o u t = A v ⋅ V in = 20 × 50.0 , mV = 1000 , mV = 1.00 , V