Study guide

3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds)

Florida HVAC Contractor License Class A/B

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts & License Classes 1.2 Exam Format, Open-Book Rules & Pearson VUE 1.3 Eligibility, Experience Paths & Financial Responsibility

2 Establishing the Contracting Business

2.1 Business Organizational Structure 2.2 Business Plan, Marketplace & License Scope 2.3 Professionals, Fixed Assets & Bonding

3 Insurance for Florida HVAC Contractors

3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds) 3.2 Coverages, Limits & Policy Language 3.3 Maintaining Insurance & CILB Certificate-Holder Rules

4 Overhead, Staffing & Markets

4.1 Developing the Business, Staffing & Markets 4.2 Determining Business Overhead (FICA, FUTA, SUTA, Workers' Comp, Rent & Utilities) 4.3 Determining Outsourced Services

5 Bids, Proposals & Estimating

5.1 Preparing Bids and Proposals 5.2 AIA Documents, Offers & Contract Components 5.3 Labor Productivity, Overhead & Project Costing

6 Purchasing, Invoices, Draws & Safety Programs

6.1 Purchasing Materials, UCC & Inventory (FIFO) 6.2 Invoices, Draw Requests & Percentage of Completion 6.3 Developing a Safety Program (OSHA, SDS & Drug Testing)

7 Managing Contracts

7.1 Contract Law, Scope & Completion Schedules 7.2 Florida Lien Law Inside Contracting 7.3 Mediation, Arbitration, Tort Law & Risk

8 Managing Trade Operations

8.1 Scheduling Trade Operations (CPM, RFI & Submittals) 8.2 OSHA Records, Document Retainage & Penalties 8.3 Takeoffs, Equipment Lease vs Purchase & Inventory

9 Accounting I: Receivables, Payables & Cash

9.1 Managing Accounts Receivable 9.2 Managing Accounts Payable & Discounts 9.3 Cash Flow, Banking & Financial Ratios

10 Accounting II: Taxes, Job Cost & Payroll

10.1 Filing Tax Forms & Returns 10.2 Tracking Job Costs 10.3 Payroll, Employment Taxes & Garnishments

11 Managing Human Resources

11.1 Hiring, I-9, Background Checks & Discrimination 11.2 HR Policies, OSHA & Drug-Test Chain of Custody 11.3 Evaluating Employees

12 Florida Contractor Law: Chapter 489 & 61G4

12.1 Chapter 489: Certified vs Registered & Qualifying Agents 12.2 61G4 Board Rules, Advertising & Discipline 12.3 Qualifying Agent Duties, Supervision & Additional Entities

13 Florida Construction Lien Law (Chapter 713)

13.1 Construction Lien Overview & Claimants 13.2 Notices to Owner, Time Limits & Perfecting Liens 13.3 Payment Bonds, Waivers & Claims of Lien

14 Financial Responsibility, CE & Federal Rules

14.1 Financial Responsibility & the 660 FICO Rule 14.2 Continuing Education & Biennial Renewal 14.3 Federal Employment, Immigration, OSHA & Environmental Rules

15 Plans, Specs & Equipment Selection

15.1 Reading Plans, Specifications, Symbols & Scales 15.2 Recommending Plan Changes & Equipment Types 15.3 EER, SEER, ARI Listings & Cost Effectiveness

16 Energy Codes, Loads & Thermal Resistance

16.1 Florida Energy Codes, R-Values & U-Factors 16.2 Determining HVAC Heating & Cooling Loads 16.3 Applying Energy Conservation, Fan Curves & Pump Curves

17 HVAC System & Duct Design

17.1 Designing HVAC Systems (Psychrometrics, Enthalpy & Airflow) 17.2 Designing Duct Systems & Insulation 17.3 Selecting Equipment, Location & Codes

18 Piping, Pumps, Boilers, Controls & Rigging Design

18.1 Pipe Sizing, Valves, Fittings, Sealants & Layout 18.2 Control Requirements, Fan Motors, CFM & Compressor Capacity 18.3 Pumps, Boilers, Steam, Fuel & Pipe Insulation 18.4 Grease Ducts, Live Loads, Rigging & Mechanical Equipment

19 Sheet Metal Duct Fabrication

19.1 Fabricating Rectangular & Round Ducts 19.2 Seams, Locks, Taping, Mastics & Liners 19.3 Fittings, Outlets & Grilles 19.4 Kitchen Hoods, Exhausts & Drain Pans

20 Split, Package & Heat Pump Installation

20.1 Installing Split & Package Air Conditioners 20.2 Installing Split & Package Heat Pumps 20.3 Air-Cooled vs Water-Cooled Systems

21 Large Systems, Chillers & Towers

21.1 Installing by Tonnage & Class A vs Class B Limits 21.2 Chilled Water, Water Towers & Secondary Coolant 21.3 Centrifugal, Absorption & Ammonia Systems

22 Refrigeration, Coolers, Ventilation & Controls Install

22.1 Low, Medium & Ultra-Low Temperature Systems & EPA Rules 22.2 Walk-In & Reach-In Coolers 22.3 Ventilation, Exhaust, Makeup Air, Grease Ducts & Kitchen Exhaust 22.4 Geothermal, Pneumatic & DDC Controls, TAB & Smoke Tests

23 Condensers, Compressors & Air Handlers

23.1 Installing Air-Cooled & Water-Cooled Condensers 23.2 Hermetic, Semi-Hermetic & Centrifugal Compressors 23.3 Air Handlers, Evaporators, Heat Exchangers, Receivers & Heat Strips

24 Duct, Fans, Filters & Terminals

24.1 Installing Sheet Metal, Fiberglass & Flexible Duct 24.2 Fans, Blowers, Motors, Grilles, Registers & Fire Dampers 24.3 Filters, Flues, Warm-Air, Gas & Fuel-Oil Appliances

25 Refrigerant Piping & Joining

25.1 Refrigerant Piping, Copper Tubing & Pipe Sizing 25.2 Brazing, Welding, Flaring, Swaging & Soldering 25.3 Steel Pipe, Plastic Pipe, Threading & Oxy-Acetylene 25.4 Hangers, Supports, Horizontally Supported Piping & Pressure Testing

26 Metering Devices & Line Components

26.1 TXVs, Capillary Tubes, Reversing Valves & Metering Devices 26.2 Liquid, Suction & Heat-Pump Dryers, Filters & Oil Traps 26.3 Receivers, Heat Strips, Gas/Oil Appliances & Related Accessories

27 Controls Installation

27.1 Pressure, Temperature, Humidity & Bellows Controls 27.2 Thermostats, Humidistats, Pneumatic & Solid-State Controls 27.3 Transformers, Capacitors, Contactors, Relays & Safety Disconnects 27.4 Defrost Components, Starters, Solenoids & Limit Switches

28 Motors, Wiring & Electrical Installation

28.1 Wiring Single-Phase & Three-Phase Equipment 28.2 Motor Types, Protection, Controllers, Belts & Pulleys 28.3 Geothermal Loops, Surge Protectors, Phase Monitors & Plastic Pipe

29 Diagnostic Analysis: Refrigeration

29.1 Pressure-Enthalpy Diagrams & Operating Pressures 29.2 Air Volumes, Enthalpy, Wet-Bulb & Dry-Bulb 29.3 Leak Detection & Refrigeration Test Instruments

30 Diagnostic Analysis: Electrical & Instruments

30.1 Current Draw, Voltage, Power & Motor Terminals 30.2 Testing Relays, Capacitors, Starters, Transformers & Defrost Stats 30.3 Using Amprobes, Velometers, Pitot Tubes, Manometers & Gauges

31 Recovery, Repair & Calibration

31.1 Nitrogen & Gas Regulators, Recovery & Retrofit 31.2 Repairing Hermetic, Semi-Hermetic, Centrifugal Compressors & Blowers 31.3 Calibrating Thermostats, Pressure Switches & Pneumatic Controls 31.4 Superheat, Safety Cutouts, Defrost Clocks & Freezer Controls

32 Mechanical Service & Cleaning

32.1 Belts, Pulleys, Motor Rotation & Seized Compressors 32.2 Crankcase & Evaporator Pressure Regulators & Unloaders 32.3 Cleaning Towers, Condensers, Foreign Matter & Condensate Drains

33 Jobsite Safety & Equipment

33.1 PPE: Hearing, Head, Eye, Face & Respiratory Protection 33.2 Lockout/Tagout, Warning Signs, Toxic Materials & Ventilation 33.3 Rigging, Hoists, Cranes, Forklifts, Backhoes & Excavation 33.4 Ladders, Scaffolds, Tools & Air Compressors

34 Energy Management

34.1 Envelope, Duct Pressure & Blower-Door Testing 34.2 Efficient Equipment, Zoning, ERVs, Wi-Fi Thermostats & Green Buildings 34.3 Energy Forms, R/U Factors, Window Heat Gain & Florida Load Calcs

35 Indoor Air Quality

35.1 Ventilation, Filtration, Humidity, UV & Air Cleaners 35.2 Contaminants, Source Control, TAB & Human Health Effects

3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds)

Key Takeaways Explain This Topic AI

Rule 61G4-15.003 requires air conditioning contractors to carry $100,000 public liability and $25,000 property damage — not the $300,000 / $50,000 general-contractor figures.

Class A and Class B Air Conditioning Contractors share the same CILB insurance minimums; unlimited Class A scope does not raise the Board floor.

Construction-industry employers must secure Chapter 440 workers' compensation when they have one or more employees; a qualifying officer's exemption never covers employees.

F.S. 489.115(5)(d) lets an initial applicant attest that a Notice of Election to be Exempt will be obtained within 30 days after the license is issued.

GL, auto, and inland-marine premiums are general overhead; workers' compensation is a labor burden allocated to jobs by payroll — do not treat a quoted premium dollar as an exam fact.

Last updated: August 2026

3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds)

Florida's Construction Industry Licensing Board will not let an Air Conditioning Contractor keep an active certificate or registration unless the business is properly insured. Business & Finance Area A item 5 (Obtain Insurance) is not a sales pitch for an agent — it is a licensing, accounting, and risk-transfer decision you make before the first rooftop changeout, refrigerant recovery, or service call.

The statutory trigger: affidavit first, coverage always

Section 489.115(5)(a), Florida Statutes , makes an affidavit of insurance a prerequisite to initial issuance or renewal of a CILB certificate or registration. On a Board form, the applicant attests that the firm has obtained workers' compensation as required by Chapter 440 , plus public liability and property damage insurance for the safety and welfare of the public, in amounts the Board sets by rule. Rule 61G4-15.003 converts that affidavit into a continuing duty: the applicant has obtained and will maintain those coverages for the life of an active certificate or registration , including a change of status onto active. Failing to continually maintain the stated amounts is a violation of the rule .

The DBPR Construction Industry FAQ restates the same duty in exam-ready language: active licensees must maintain minimum amounts of insurance at all times. Do not treat insurance as a renewal-week paperwork item.

CILB does not require a licensing surety bond to certify an Air Conditioning Contractor. Keep three instruments separate: (1) CILB public-liability and property-damage insurance, (2) Chapter 440 workers' compensation or a valid exemption, and (3) surety — bid, performance, and payment bonds demanded by owners, or the $100,000 Financially Responsible Officer bond payable to CILB when a firm designates an FRO. A letter of bondability is not a substitute for an FRO bond; an irrevocable letter of credit in the same amount is.

CILB limits: HVAC is $100,000 / $25,000, not the GC line

Rule 61G4-15.003(2)(h) publishes aggregate public-liability and property-damage amounts by license category. HVAC candidates miss B&F items when they memorize the General Contractor row.

  • License category (61G4-15.003) Public liability (aggregate) Property damage (aggregate)
  • General Contractor $300,000 $50,000
  • Building Contractor $300,000 $50,000
  • Air Conditioning Contractor $100,000 $25,000

Mechanical, plumbing, roofing, sheet metal, pool, solar, residential, underground utility, pollutant storage, and specialty (unless specified otherwise) $100,000 $25,000

Class A (unlimited capacity) and Class B (not more than 25 tons cooling and 500,000 Btu heating in any one system) share the Air Conditioning Contractor row. Passing the Class A trade exam does not bump you to $300,000 / $50,000. A Miami Class A crew setting a 40-ton rooftop package and a Class B shop replacing a 3-ton split in a Cape Coral house both need $100,000 public liability and $25,000 property damage to satisfy the Board.

Those numbers are license minimums . A general contractor, school board, or property manager can still require higher contract limits. Bind what the contract requires; answer CILB questions with $100,000 / $25,000 .

The coverages an HVAC contractor actually buys

Obtaining insurance means assembling a portfolio , not buying a single certificate:

Commercial general liability (GL / public liability) — third-party bodily injury and property damage from operations. Example: a condenser is staged at the curb and a passerby trips over the disconnect whip.

Property damage as CILB still lists a separate aggregate. Many modern GL policies combine bodily injury and property damage; the certificate still has to evidence the Board amounts.

Workers' compensation — medical and indemnity for employees under Chapter 440. Example: a helper's extension ladder kicks out during a rooftop changeout.

Commercial automobile — owned service vans plus hired and non-owned auto if technicians use personal vehicles between calls.

Inland marine (tools and equipment) — recovery machines, vacuum pumps, brazing kits, and copper stolen from a truck at a Daytona Beach job.

Umbrella or excess — extra limit over GL and auto when a hospital or GC specification dwarfs CILB's floor.

Builders risk — usually purchased by the owner or GC on new construction; the HVAC sub confirms whether installed equipment is covered before it is accepted.

Completed operations — the GL grant that responds after you leave the roof (a poorly brazed liquid line weeps into a ceiling three weeks later).

Surety bonds — bid (good-faith bid), performance (complete the contract), payment (pay subcontractors and suppliers). Surety is a credit guarantee, not an insurance indemnity, but B&F groups it with insurance because both transfer project risk.

Loading diagram...

Chapter 440 workers' compensation and the employee trigger

CILB does not publish a workers' compensation dollar limit. Chapter 440 supplies the duty. Air-conditioning work is construction industry employment under F.S. 440.02. Construction employers must secure compensation when they have one or more employees . The non-construction four-employee threshold does not apply to HVAC contractors.

Employees trigger a policy. A qualifying officer's exemption never covers helpers, installers, office staff, or leased labor. Hire one Saturday helper for a rooftop changeout and the corporation needs workers' compensation on that employee.

F.S. 440.10: if you sublet ductwork or start-up and the subcontractor has neither a Florida workers' compensation policy nor a valid exemption, that sub's workers become your statutory employees . Out-of-state subcontractors need Florida listed in Item 3.A. of the policy information page.

Notice of Election to be Exempt

F.S. 440.02 and 440.05 allow certain corporate officers and 10-percent LLC members to elect out of Chapter 440 for themselves . Construction-industry rules:

The entity is active at the Division of Corporations.

The officer or member owns at least 10 percent and is listed as an officer or member.

No more than three officers or members of the corporation or affiliated group may hold exemptions.

File a Notice of Election to be Exempt electronically with the Division of Workers' Compensation, complete the online coverage-and-compliance tutorial, and receive a Certificate of Election to be Exempt .

The certificate is valid two years from the effective date (F.S. 440.05(6)) and names only that officer .

An exemption is not insurance . The officer cannot recover workers' compensation benefits.

F.S. 489.115(5)(d) and the DBPR FAQ: you may apply for licensure before the exemption is issued if you attest that you will obtain the exemption within 30 days after the initial certificate or registration is issued.

Sole proprietors and partners in the construction industry are employees under F.S. 440.02. Remaining a sole proprietor does not create an exemption. Form a corporation or LLC, qualify as a 10-percent officer or member, and file the Notice.

Accounting treatment: overhead versus labor burden

Do not memorize a premium dollar amount. Carriers rate by payroll, class code, territory, and claims, and this guide will not invent a quote. What B&F tests is where the cost lives in the books (Builder's Guide to Accounting; Contractors Manual):

Workers' compensation is a labor burden , estimated from payroll like FICA, FUTA, and SUTA, then allocated to jobs by job payroll.

GL, auto, inland marine, and umbrella are general overhead . Recover them in the overhead markup on every estimate, not as a surprise line item on a residential changeout unless the owner bought a project-specific endorsement.

Builders risk and performance-bond premiums required by a single contract are usually direct job costs .

Lost-bid bond fees are overhead.

Forget workers' compensation burden on a Class B changeout and the job can look profitable until the audit bills additional premium. That is an Area D costing error as well as an Area A insurance error.

Putting the package together before the first permit

A new certified Class B qualifier in Jacksonville organizes Coastal Comfort HVAC, LLC, owns 100 percent, and applies to qualify the LLC. Before the license can be active she binds GL at CILB's $100,000 / $25,000 in the exact LLC name , files the Notice of Election and calendars 30 days, adds auto and inland marine, and writes her estimates with GL in overhead and a plan for workers' compensation burden the day she hires. That is obtaining insurance for Florida HVAC contractors.