Study guide

2.1 Business Organizational Structure

Florida HVAC Contractor License Class A/B

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts & License Classes 1.2 Exam Format, Open-Book Rules & Pearson VUE 1.3 Eligibility, Experience Paths & Financial Responsibility

2 Establishing the Contracting Business

2.1 Business Organizational Structure 2.2 Business Plan, Marketplace & License Scope 2.3 Professionals, Fixed Assets & Bonding

3 Insurance for Florida HVAC Contractors

3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds) 3.2 Coverages, Limits & Policy Language 3.3 Maintaining Insurance & CILB Certificate-Holder Rules

4 Overhead, Staffing & Markets

4.1 Developing the Business, Staffing & Markets 4.2 Determining Business Overhead (FICA, FUTA, SUTA, Workers' Comp, Rent & Utilities) 4.3 Determining Outsourced Services

5 Bids, Proposals & Estimating

5.1 Preparing Bids and Proposals 5.2 AIA Documents, Offers & Contract Components 5.3 Labor Productivity, Overhead & Project Costing

6 Purchasing, Invoices, Draws & Safety Programs

6.1 Purchasing Materials, UCC & Inventory (FIFO) 6.2 Invoices, Draw Requests & Percentage of Completion 6.3 Developing a Safety Program (OSHA, SDS & Drug Testing)

7 Managing Contracts

7.1 Contract Law, Scope & Completion Schedules 7.2 Florida Lien Law Inside Contracting 7.3 Mediation, Arbitration, Tort Law & Risk

8 Managing Trade Operations

8.1 Scheduling Trade Operations (CPM, RFI & Submittals) 8.2 OSHA Records, Document Retainage & Penalties 8.3 Takeoffs, Equipment Lease vs Purchase & Inventory

9 Accounting I: Receivables, Payables & Cash

9.1 Managing Accounts Receivable 9.2 Managing Accounts Payable & Discounts 9.3 Cash Flow, Banking & Financial Ratios

10 Accounting II: Taxes, Job Cost & Payroll

10.1 Filing Tax Forms & Returns 10.2 Tracking Job Costs 10.3 Payroll, Employment Taxes & Garnishments

11 Managing Human Resources

11.1 Hiring, I-9, Background Checks & Discrimination 11.2 HR Policies, OSHA & Drug-Test Chain of Custody 11.3 Evaluating Employees

12 Florida Contractor Law: Chapter 489 & 61G4

12.1 Chapter 489: Certified vs Registered & Qualifying Agents 12.2 61G4 Board Rules, Advertising & Discipline 12.3 Qualifying Agent Duties, Supervision & Additional Entities

13 Florida Construction Lien Law (Chapter 713)

13.1 Construction Lien Overview & Claimants 13.2 Notices to Owner, Time Limits & Perfecting Liens 13.3 Payment Bonds, Waivers & Claims of Lien

14 Financial Responsibility, CE & Federal Rules

14.1 Financial Responsibility & the 660 FICO Rule 14.2 Continuing Education & Biennial Renewal 14.3 Federal Employment, Immigration, OSHA & Environmental Rules

15 Plans, Specs & Equipment Selection

15.1 Reading Plans, Specifications, Symbols & Scales 15.2 Recommending Plan Changes & Equipment Types 15.3 EER, SEER, ARI Listings & Cost Effectiveness

16 Energy Codes, Loads & Thermal Resistance

16.1 Florida Energy Codes, R-Values & U-Factors 16.2 Determining HVAC Heating & Cooling Loads 16.3 Applying Energy Conservation, Fan Curves & Pump Curves

17 HVAC System & Duct Design

17.1 Designing HVAC Systems (Psychrometrics, Enthalpy & Airflow) 17.2 Designing Duct Systems & Insulation 17.3 Selecting Equipment, Location & Codes

18 Piping, Pumps, Boilers, Controls & Rigging Design

18.1 Pipe Sizing, Valves, Fittings, Sealants & Layout 18.2 Control Requirements, Fan Motors, CFM & Compressor Capacity 18.3 Pumps, Boilers, Steam, Fuel & Pipe Insulation 18.4 Grease Ducts, Live Loads, Rigging & Mechanical Equipment

19 Sheet Metal Duct Fabrication

19.1 Fabricating Rectangular & Round Ducts 19.2 Seams, Locks, Taping, Mastics & Liners 19.3 Fittings, Outlets & Grilles 19.4 Kitchen Hoods, Exhausts & Drain Pans

20 Split, Package & Heat Pump Installation

20.1 Installing Split & Package Air Conditioners 20.2 Installing Split & Package Heat Pumps 20.3 Air-Cooled vs Water-Cooled Systems

21 Large Systems, Chillers & Towers

21.1 Installing by Tonnage & Class A vs Class B Limits 21.2 Chilled Water, Water Towers & Secondary Coolant 21.3 Centrifugal, Absorption & Ammonia Systems

22 Refrigeration, Coolers, Ventilation & Controls Install

22.1 Low, Medium & Ultra-Low Temperature Systems & EPA Rules 22.2 Walk-In & Reach-In Coolers 22.3 Ventilation, Exhaust, Makeup Air, Grease Ducts & Kitchen Exhaust 22.4 Geothermal, Pneumatic & DDC Controls, TAB & Smoke Tests

23 Condensers, Compressors & Air Handlers

23.1 Installing Air-Cooled & Water-Cooled Condensers 23.2 Hermetic, Semi-Hermetic & Centrifugal Compressors 23.3 Air Handlers, Evaporators, Heat Exchangers, Receivers & Heat Strips

24 Duct, Fans, Filters & Terminals

24.1 Installing Sheet Metal, Fiberglass & Flexible Duct 24.2 Fans, Blowers, Motors, Grilles, Registers & Fire Dampers 24.3 Filters, Flues, Warm-Air, Gas & Fuel-Oil Appliances

25 Refrigerant Piping & Joining

25.1 Refrigerant Piping, Copper Tubing & Pipe Sizing 25.2 Brazing, Welding, Flaring, Swaging & Soldering 25.3 Steel Pipe, Plastic Pipe, Threading & Oxy-Acetylene 25.4 Hangers, Supports, Horizontally Supported Piping & Pressure Testing

26 Metering Devices & Line Components

26.1 TXVs, Capillary Tubes, Reversing Valves & Metering Devices 26.2 Liquid, Suction & Heat-Pump Dryers, Filters & Oil Traps 26.3 Receivers, Heat Strips, Gas/Oil Appliances & Related Accessories

27 Controls Installation

27.1 Pressure, Temperature, Humidity & Bellows Controls 27.2 Thermostats, Humidistats, Pneumatic & Solid-State Controls 27.3 Transformers, Capacitors, Contactors, Relays & Safety Disconnects 27.4 Defrost Components, Starters, Solenoids & Limit Switches

28 Motors, Wiring & Electrical Installation

28.1 Wiring Single-Phase & Three-Phase Equipment 28.2 Motor Types, Protection, Controllers, Belts & Pulleys 28.3 Geothermal Loops, Surge Protectors, Phase Monitors & Plastic Pipe

29 Diagnostic Analysis: Refrigeration

29.1 Pressure-Enthalpy Diagrams & Operating Pressures 29.2 Air Volumes, Enthalpy, Wet-Bulb & Dry-Bulb 29.3 Leak Detection & Refrigeration Test Instruments

30 Diagnostic Analysis: Electrical & Instruments

30.1 Current Draw, Voltage, Power & Motor Terminals 30.2 Testing Relays, Capacitors, Starters, Transformers & Defrost Stats 30.3 Using Amprobes, Velometers, Pitot Tubes, Manometers & Gauges

31 Recovery, Repair & Calibration

31.1 Nitrogen & Gas Regulators, Recovery & Retrofit 31.2 Repairing Hermetic, Semi-Hermetic, Centrifugal Compressors & Blowers 31.3 Calibrating Thermostats, Pressure Switches & Pneumatic Controls 31.4 Superheat, Safety Cutouts, Defrost Clocks & Freezer Controls

32 Mechanical Service & Cleaning

32.1 Belts, Pulleys, Motor Rotation & Seized Compressors 32.2 Crankcase & Evaporator Pressure Regulators & Unloaders 32.3 Cleaning Towers, Condensers, Foreign Matter & Condensate Drains

33 Jobsite Safety & Equipment

33.1 PPE: Hearing, Head, Eye, Face & Respiratory Protection 33.2 Lockout/Tagout, Warning Signs, Toxic Materials & Ventilation 33.3 Rigging, Hoists, Cranes, Forklifts, Backhoes & Excavation 33.4 Ladders, Scaffolds, Tools & Air Compressors

34 Energy Management

34.1 Envelope, Duct Pressure & Blower-Door Testing 34.2 Efficient Equipment, Zoning, ERVs, Wi-Fi Thermostats & Green Buildings 34.3 Energy Forms, R/U Factors, Window Heat Gain & Florida Load Calcs

35 Indoor Air Quality

35.1 Ventilation, Filtration, Humidity, UV & Air Cleaners 35.2 Contaminants, Source Control, TAB & Human Health Effects

2.1 Business Organizational Structure

Key Takeaways Explain This Topic AI

Under F.S. 489.119, a sole proprietorship license is issued only to the individual; anyone contracting through a partnership, LLC, corporation, or other entity must apply as that organization's qualifying agent.

F.S. 489.1195 makes every primary qualifying agent jointly and equally responsible for operations, all field work, and financial matters unless the Construction Industry Licensing Board approves a financially responsible officer, who may not also be the primary qualifying agent.

If the only qualifying agent leaves, F.S. 489.119(3)(a) gives the business 60 days to employ another qualifying agent; the firm may not contract in the gap except on incomplete contracts under a temporary nonrenewable certificate.

C-corporations pay 21% federal entity-level tax plus Florida corporate income/franchise tax at 5.5% after a $50,000 exemption; S-corporations and other pass-throughs generally avoid Florida entity-level corporate tax.

DBPR CILB 6-G (effective July 2024) is the application for a certified Class A air-conditioning contractor who is qualifying a business; Class B uses CILB 6-H.

Last updated: August 2026

2.1 Business Organizational Structure

Florida HVAC contractors lose Business & Finance (B&F) points when they treat the company as if it were the license. Chapter 489 of the Florida Statutes is the opposite: the qualifying agent (QA) is always a natural person, and the business organization is what that person qualifies. Area A of the B&F exam — Establishing the Contracting Business — is 11% of 120 questions , roughly 13 items. Organizational form, tax consequences, fiduciary duty, and the QA chain of responsibility sit at the center of that cluster. The 2026 B&F references that carry this material are Florida Statutes Chapter 455 (2025 edition), the Contractors Manual 2025 (used beginning February 1, 2026), and Builder's Guide to Accounting (2001).

Sole proprietorship, partnership, LLC, C-corporation, and S-corporation

A sole proprietorship is the owner doing business in the owner's legal name or a fictitious name. Under F.S. 489.119(1), if you contract in your own name or as a sole proprietorship under a fictitious name, registration or certification may be issued only to that individual . There is no liability shield. Injured customers, unpaid suppliers, and the Construction Industry Licensing Board (CILB) look through to you. Federal income tax is pass-through on Schedule C of Form 1040, plus self-employment tax at 15.3% of net earnings (12.4% Social Security up to the annual wage base and 2.9% Medicare with no cap). Florida has no individual income tax , so the sole proprietor does not pay a second state income tax on those profits. That tax simplicity is real. Unlimited personal liability is also real.

A partnership under Chapter 620 is two or more persons carrying on a business for profit. General partners share profits, losses, and joint and several liability. Partnerships file federal Form 1065 and issue Schedule K-1s; they do not pay federal entity-level income tax. For CILB purposes a partnership is a business organization under F.S. 489.105(13). You cannot simply “use the partner’s license.” F.S. 489.119(2) requires the applicant to apply for registration or certification as the qualifying agent of the business organization and to list the partnership and its partners by name. A joint venture, including a joint venture of already-qualified companies, is itself a separate organization that must be qualified under board rules (489.119(2)(e)).

A limited liability company (LLC) formed under Chapter 605 is the structure most Florida HVAC start-ups actually file. Articles of organization go to the Florida Division of Corporations (Sunbiz). Official Sunbiz fees for a new Florida LLC are a $100 filing fee plus a $25 registered-agent fee ( $125 total). An LLC is a state-law entity , not a federal tax classification. Default Internal Revenue Service treatment: a single-member LLC is a disregarded entity (Schedule C); a multi-member LLC is a partnership (Form 1065). Members may elect C-corporation treatment on Form 8832 or S-corporation treatment on Form 2553. The operating agreement and the CILB qualifying affidavits must match. F.S. 489.119(2)(b) requires the QA to attest to final approval authority on all construction work and on all business matters — contracts, specifications, checks, drafts, or payments — unless a financially responsible officer (FRO) is approved.

A C-corporation under the Florida Business Corporation Act, Chapter 607, is a separate taxable person. It files federal Form 1120. The federal corporate rate is a flat 21% . Florida then imposes corporate income/franchise tax on corporations, including entities taxed federally as corporations, at 5.5% of Florida net income after a $50,000 exemption (Florida Department of Revenue; that 5.5% rate applies to taxable years beginning on or after January 1, 2022). Shareholders who take remaining profits as dividends pay a second federal tax. That is double taxation . C-corporations may have unlimited shareholders, multiple classes of stock, and entity owners, which matters if you later want outside capital. They are heavier to administer: articles, bylaws, board minutes, and Florida Form F-1120 even when little tax is due.

An S-corporation is a federal tax election , not a Florida entity type. Eligible corporations — and LLCs that elect corporate tax treatment — file IRS Form 2553. Limits the exam tests: no more than 100 shareholders , one class of stock , and eligible shareholders (United States individuals and certain trusts; no nonresident-alien, partnership, or corporate owners). S-corporations generally pay no federal entity-level income tax; income passes through on Form 1120-S and Schedule K-1. Florida generally does not tax S-corporations at the entity level unless the S-corporation pays federal tax on specified lines of Form 1120-S. Owners who work in the business must take reasonable W-2 wages; remaining profit can be distributed without self-employment tax. That payroll discipline is a common reason a profitable HVAC LLC elects S status — and a common CILB/surety red flag when the qualifier draws only distributions and no wage.

Structure Liability shield Federal income tax Florida income/franchise tax CILB licensing posture

Sole proprietorship None Pass-through, Schedule C No Florida individual income tax License issued to the individual (F.S. 489.119(1))

Partnership None for general partners Pass-through, Form 1065 No Florida individual income tax Must qualify the partnership as a business organization

LLC Yes, if capitalization and formalities are respected Default disregarded or partnership; may elect C or S Pass-through generally avoids Florida corporate tax; a C-election pays 5.5% Must qualify the LLC and list members

C-corporation Yes Entity-level 21%, then tax on dividends 5.5% after $50,000 exemption Must qualify the corporation; list officers, directors, and officer-shareholders

S-corporation Yes (corporation or LLC electing S) Pass-through, Form 1120-S Generally no Florida corporate tax unless federal tax is paid on Form 1120-S Same qualifying rules as the underlying legal entity

Open versus closed corporations

B&F materials distinguish open and closed corporations. A closed corporation (closely held) does not offer stock to the public. Ownership is concentrated — often a family HVAC shop — and stock transfer is typically restricted by a shareholder agreement. Florida permits unanimous written shareholder agreements for corporations with fewer than 100 shareholders (F.S. 607.0732) to set transfer and governance rules, but those agreements cannot wipe out the fiduciary duties of officers, directors, and controlling shareholders. An open corporation may sell stock to the public, has many shareholders, and carries heavier securities and reporting obligations. Almost every HVAC contractor on this exam is a closed corporation or an LLC. Do not confuse “closed corporation” with “S-corporation”: S is a tax election; closed versus open describes how stock is held and transferred.

Fiduciary duties of officers and directors

F.S. 607.0830 requires each director, when discharging board duties, to act in good faith and in a manner the director reasonably believes to be in the best interests of the corporation . When becoming informed for a decision or performing oversight, directors must use the care that an ordinarily prudent person in a like position would reasonably believe appropriate. Officers owe parallel duties of care and loyalty : they may not divert corporate opportunities, compete with the company using company crews or customer lists, or approve related-party equipment leases that enrich themselves at the corporation’s expense. The business judgment rule protects informed, good-faith decisions that later turn out poorly. It does not protect self-dealing, a lapse in CILB insurance, or ignoring job-cost losses until suppliers are unpaid.

Those Chapter 607 duties sit beside Chapter 489 duties. F.S. 489.105(4) defines a primary qualifying agent as the person who supervises, directs, manages, and controls the contracting activities of the business organization and the construction activities on jobs for which that person obtained the permit. F.S. 489.105(5) defines a secondary qualifying agent as the person responsible for construction activities on jobs for which that person obtained the permit. F.S. 489.105(14) defines an FRO as a person other than the primary QA who, with board approval, assumes personal responsibility for all financial aspects of the business organization.

Under F.S. 489.1195(1)(a), all primary qualifying agents are jointly and equally responsible for supervision of all operations of the business organization, for all field work at all sites, and for financial matters, both for the organization in general and for each specific job — unless the board approves an FRO. An FRO (489.1195(1)(b)) is responsible for all financial aspects and may not be designated as the primary QA. If an FRO is in place, the primary QA remains responsible for all construction activities (489.1195(1)(c)). Board rules for FROs must include net worth, cash, and bonding requirements at least as extensive as those for qualifying agents (489.1195(1)(d)); do not invent a single published HVAC dollar figure for that FRO bond. Secondary QAs, designated by a board-approved joint agreement, are responsible only for field work at sites where their license pulled the permit and for other work they accept; they are not responsible for supervision of financial matters (489.1195(2)(e)).

Org chart and chain of responsibility

Draw the chart from the license out, not from the owner out. The CILB certificate belongs to the individual QA. The business organization is qualified by that person. For a new Class A HVAC company that is qualifying a business, the form is DBPR CILB 6-G , Application for Certified Class-A Air Conditioning Contractor Who is Qualifying a Business (effective July 2024; Rule 61-35.010). Class B uses CILB 6-H . Contracting as an individual with no entity uses CILB 5-G . Qualifying an additional business later requires a new application, payment of a fee equal to the original registration or certification fee, and evidence the QA can supervise each organization (F.S. 489.119(6)). Approval of each additional organization is discretionary with the board.

If the only QA ceases to be affiliated, F.S. 489.119(3)(a) requires notice to the Department of Business and Professional Regulation (DBPR) and gives the business organization 60 days to employ another QA. The organization may not engage in contracting until a QA is employed, unless the executive director or chair of the board grants a temporary, nonrenewable certificate to the FRO, president, partner, or, in a limited partnership, the general partner. That temporary ticket covers incomplete contracts only — contracts already awarded or entered into, or jobs on which the firm was the low bidder and the contract is later awarded. It is not a hunting license for new bids.

Chapter 455 (2025 edition on the B&F list) is the umbrella professional-regulation chapter. DBPR licenses and disciplines under that chapter as well as Chapter 489. Unlicensed contracting, fraud, and failure to maintain required insurance or financial responsibility are department-level problems, not merely “company” problems. The individual QA remains the named professional.

Florida HVAC scenario

Maria holds a certified Class A air-conditioning license. She forms Gulf Breeze Mechanical, LLC on Sunbiz, names herself managing member, and files CILB 6-G to qualify the LLC. She later hires her brother Luis, also Class A certified, as a project manager. They execute a joint agreement designating Maria as sole primary QA and Luis as secondary QA; CILB approves it. Luis pulls the permit on a 40-ton rooftop job in Pensacola. If the condenser is set wrong, Luis is responsible for that site’s field work and Maria is jointly responsible for field supervision. Maria — unless an FRO is designated — remains responsible for whether the LLC paid the equipment vendor. If Maria later sells her membership units to an unlicensed investor, the LLC does not become licensed through the investor. The certificate never belonged to the LLC. If Maria then resigns as QA, the LLC has 60 days to employ another qualifier and cannot take new contracts in the gap.

The exam trap is always the same: ownership is not licensure, a tax election is not a liability shield by itself, and a secondary QA does not take the primary’s financial duties unless the board has approved an FRO.

Loading diagram... Florida HVAC qualifying chain and business structures