Study guide

1.3 Eligibility, Experience Paths & Financial Responsibility

Florida HVAC Contractor License Class A/B

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts & License Classes 1.2 Exam Format, Open-Book Rules & Pearson VUE 1.3 Eligibility, Experience Paths & Financial Responsibility

2 Establishing the Contracting Business

2.1 Business Organizational Structure 2.2 Business Plan, Marketplace & License Scope 2.3 Professionals, Fixed Assets & Bonding

3 Insurance for Florida HVAC Contractors

3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds) 3.2 Coverages, Limits & Policy Language 3.3 Maintaining Insurance & CILB Certificate-Holder Rules

4 Overhead, Staffing & Markets

4.1 Developing the Business, Staffing & Markets 4.2 Determining Business Overhead (FICA, FUTA, SUTA, Workers' Comp, Rent & Utilities) 4.3 Determining Outsourced Services

5 Bids, Proposals & Estimating

5.1 Preparing Bids and Proposals 5.2 AIA Documents, Offers & Contract Components 5.3 Labor Productivity, Overhead & Project Costing

6 Purchasing, Invoices, Draws & Safety Programs

6.1 Purchasing Materials, UCC & Inventory (FIFO) 6.2 Invoices, Draw Requests & Percentage of Completion 6.3 Developing a Safety Program (OSHA, SDS & Drug Testing)

7 Managing Contracts

7.1 Contract Law, Scope & Completion Schedules 7.2 Florida Lien Law Inside Contracting 7.3 Mediation, Arbitration, Tort Law & Risk

8 Managing Trade Operations

8.1 Scheduling Trade Operations (CPM, RFI & Submittals) 8.2 OSHA Records, Document Retainage & Penalties 8.3 Takeoffs, Equipment Lease vs Purchase & Inventory

9 Accounting I: Receivables, Payables & Cash

9.1 Managing Accounts Receivable 9.2 Managing Accounts Payable & Discounts 9.3 Cash Flow, Banking & Financial Ratios

10 Accounting II: Taxes, Job Cost & Payroll

10.1 Filing Tax Forms & Returns 10.2 Tracking Job Costs 10.3 Payroll, Employment Taxes & Garnishments

11 Managing Human Resources

11.1 Hiring, I-9, Background Checks & Discrimination 11.2 HR Policies, OSHA & Drug-Test Chain of Custody 11.3 Evaluating Employees

12 Florida Contractor Law: Chapter 489 & 61G4

12.1 Chapter 489: Certified vs Registered & Qualifying Agents 12.2 61G4 Board Rules, Advertising & Discipline 12.3 Qualifying Agent Duties, Supervision & Additional Entities

13 Florida Construction Lien Law (Chapter 713)

13.1 Construction Lien Overview & Claimants 13.2 Notices to Owner, Time Limits & Perfecting Liens 13.3 Payment Bonds, Waivers & Claims of Lien

14 Financial Responsibility, CE & Federal Rules

14.1 Financial Responsibility & the 660 FICO Rule 14.2 Continuing Education & Biennial Renewal 14.3 Federal Employment, Immigration, OSHA & Environmental Rules

15 Plans, Specs & Equipment Selection

15.1 Reading Plans, Specifications, Symbols & Scales 15.2 Recommending Plan Changes & Equipment Types 15.3 EER, SEER, ARI Listings & Cost Effectiveness

16 Energy Codes, Loads & Thermal Resistance

16.1 Florida Energy Codes, R-Values & U-Factors 16.2 Determining HVAC Heating & Cooling Loads 16.3 Applying Energy Conservation, Fan Curves & Pump Curves

17 HVAC System & Duct Design

17.1 Designing HVAC Systems (Psychrometrics, Enthalpy & Airflow) 17.2 Designing Duct Systems & Insulation 17.3 Selecting Equipment, Location & Codes

18 Piping, Pumps, Boilers, Controls & Rigging Design

18.1 Pipe Sizing, Valves, Fittings, Sealants & Layout 18.2 Control Requirements, Fan Motors, CFM & Compressor Capacity 18.3 Pumps, Boilers, Steam, Fuel & Pipe Insulation 18.4 Grease Ducts, Live Loads, Rigging & Mechanical Equipment

19 Sheet Metal Duct Fabrication

19.1 Fabricating Rectangular & Round Ducts 19.2 Seams, Locks, Taping, Mastics & Liners 19.3 Fittings, Outlets & Grilles 19.4 Kitchen Hoods, Exhausts & Drain Pans

20 Split, Package & Heat Pump Installation

20.1 Installing Split & Package Air Conditioners 20.2 Installing Split & Package Heat Pumps 20.3 Air-Cooled vs Water-Cooled Systems

21 Large Systems, Chillers & Towers

21.1 Installing by Tonnage & Class A vs Class B Limits 21.2 Chilled Water, Water Towers & Secondary Coolant 21.3 Centrifugal, Absorption & Ammonia Systems

22 Refrigeration, Coolers, Ventilation & Controls Install

22.1 Low, Medium & Ultra-Low Temperature Systems & EPA Rules 22.2 Walk-In & Reach-In Coolers 22.3 Ventilation, Exhaust, Makeup Air, Grease Ducts & Kitchen Exhaust 22.4 Geothermal, Pneumatic & DDC Controls, TAB & Smoke Tests

23 Condensers, Compressors & Air Handlers

23.1 Installing Air-Cooled & Water-Cooled Condensers 23.2 Hermetic, Semi-Hermetic & Centrifugal Compressors 23.3 Air Handlers, Evaporators, Heat Exchangers, Receivers & Heat Strips

24 Duct, Fans, Filters & Terminals

24.1 Installing Sheet Metal, Fiberglass & Flexible Duct 24.2 Fans, Blowers, Motors, Grilles, Registers & Fire Dampers 24.3 Filters, Flues, Warm-Air, Gas & Fuel-Oil Appliances

25 Refrigerant Piping & Joining

25.1 Refrigerant Piping, Copper Tubing & Pipe Sizing 25.2 Brazing, Welding, Flaring, Swaging & Soldering 25.3 Steel Pipe, Plastic Pipe, Threading & Oxy-Acetylene 25.4 Hangers, Supports, Horizontally Supported Piping & Pressure Testing

26 Metering Devices & Line Components

26.1 TXVs, Capillary Tubes, Reversing Valves & Metering Devices 26.2 Liquid, Suction & Heat-Pump Dryers, Filters & Oil Traps 26.3 Receivers, Heat Strips, Gas/Oil Appliances & Related Accessories

27 Controls Installation

27.1 Pressure, Temperature, Humidity & Bellows Controls 27.2 Thermostats, Humidistats, Pneumatic & Solid-State Controls 27.3 Transformers, Capacitors, Contactors, Relays & Safety Disconnects 27.4 Defrost Components, Starters, Solenoids & Limit Switches

28 Motors, Wiring & Electrical Installation

28.1 Wiring Single-Phase & Three-Phase Equipment 28.2 Motor Types, Protection, Controllers, Belts & Pulleys 28.3 Geothermal Loops, Surge Protectors, Phase Monitors & Plastic Pipe

29 Diagnostic Analysis: Refrigeration

29.1 Pressure-Enthalpy Diagrams & Operating Pressures 29.2 Air Volumes, Enthalpy, Wet-Bulb & Dry-Bulb 29.3 Leak Detection & Refrigeration Test Instruments

30 Diagnostic Analysis: Electrical & Instruments

30.1 Current Draw, Voltage, Power & Motor Terminals 30.2 Testing Relays, Capacitors, Starters, Transformers & Defrost Stats 30.3 Using Amprobes, Velometers, Pitot Tubes, Manometers & Gauges

31 Recovery, Repair & Calibration

31.1 Nitrogen & Gas Regulators, Recovery & Retrofit 31.2 Repairing Hermetic, Semi-Hermetic, Centrifugal Compressors & Blowers 31.3 Calibrating Thermostats, Pressure Switches & Pneumatic Controls 31.4 Superheat, Safety Cutouts, Defrost Clocks & Freezer Controls

32 Mechanical Service & Cleaning

32.1 Belts, Pulleys, Motor Rotation & Seized Compressors 32.2 Crankcase & Evaporator Pressure Regulators & Unloaders 32.3 Cleaning Towers, Condensers, Foreign Matter & Condensate Drains

33 Jobsite Safety & Equipment

33.1 PPE: Hearing, Head, Eye, Face & Respiratory Protection 33.2 Lockout/Tagout, Warning Signs, Toxic Materials & Ventilation 33.3 Rigging, Hoists, Cranes, Forklifts, Backhoes & Excavation 33.4 Ladders, Scaffolds, Tools & Air Compressors

34 Energy Management

34.1 Envelope, Duct Pressure & Blower-Door Testing 34.2 Efficient Equipment, Zoning, ERVs, Wi-Fi Thermostats & Green Buildings 34.3 Energy Forms, R/U Factors, Window Heat Gain & Florida Load Calcs

35 Indoor Air Quality

35.1 Ventilation, Filtration, Humidity, UV & Air Cleaners 35.2 Contaminants, Source Control, TAB & Human Health Effects

1.3 Eligibility, Experience Paths & Financial Responsibility

Key Takeaways Explain This Topic AI

F.S. 489.111: an applicant for certification must be 18, of good moral character, and meet one statutory experience/education path; one year equals 2,000 person-hours.

CILB 6-G (July 2024) methods: construction-related baccalaureate + 1 year; 1 year foreman + 3 years college credit; 1 worker + 1 foreman + 2 college; 2 worker + 1 foreman + 1 college; 4 years with at least 1 year as foreman; or upgrade from active Class B ≥1 year or Class C ≥4 years.

Class A experience on CILB 6-G should include one year on systems in excess of 25 tons cooling and 500,000 BTU heating.

61G4-15.006 (effective 5/5/2024): no unsatisfied judgments or liens (applicant and the business entity); FICO-derived score 660 or higher; below 660, complete a Board-approved 14-hour financial responsibility course.

61G4-15.003: air-conditioning contractors must carry $100,000 public liability and $25,000 property damage, with the certificate holder listed as the State of Florida, Department of Business and Professional Regulation, Construction Industry Licensing Board.

Last updated: August 2026

Eligibility is a statute-and-form problem, not an exam-score problem

Quick Answer: F.S. 489.111 requires age 18 , good moral character , and one listed experience/education method. CILB 6-G (July 2024, Class A qualifying a business; Class B uses the matching 6-H/5-H set) is how you prove it. 61G4-15.006 (effective 5/5/2024 ) is the credit-report and 660 FICO-derived rule. 61G4-15.003 is $100,000 public liability / $25,000 property damage with State of Florida, DBPR, CILB as certificate holder. Passing PTI/Pearson VUE does not skip those gates.

DBPR's examination checklist is blunt: passing the examination allows you to apply for certified licensure; a passing grade alone does not qualify you . People do sit the exams while they finish a foreman year — that is a personal timing choice, not a waiver. Confirm current application forms (5-G individual, 6-G qualifying a business, and the Class B H-series counterparts) on MyFloridaLicense; 61-35.010 incorporates those forms.

Experience methods on CILB 6-G (July 2024)

Check one box. The form states that a construction-related degree means a baccalaureate from an accredited four-year college in engineering, architecture, or building construction , and that one year of experience equals 2,000 hours . Class A applicants should be able to show one year on systems in excess of 25 tons of cooling and 500,000 BTU heating — that is the capacity that Class B cannot contract, and 6-G's employment-history checkboxes ask for it.

Method What 6-G requires

1. Degree + experience Four-year construction-related baccalaureate (counts as three years) plus one year proven experience in the category

  • 2. Foreman + college 1 year foreman and not less than 3 years of accredited college-level credits
  • 3. Worker + foreman + college 1 year worker , 1 year foreman , and 2 years college-level credits
  • 4. Worker + foreman + college 2 years worker , 1 year foreman , and 1 year college-level credits
  • 5. Time in the trade 4 years as worker or foreman, of which at least 1 year must have been as a foreman

6. Upgrade Active Class B in the classification for a minimum of 1 year , or active Class C for a minimum of 4 years (provide the license number; employment-history section is exempted on the form)

Those six boxes track F.S. 489.111(2)(c) . The statute also states junior/community-college courses count as accredited college-level courses, and it spells out HVAC upgrades in 489.111(2)(c)5: active certified Class C → Class B after 3 years in classification and the Class B exam; Class C → Class A after 4 years and the Class A exam; Class B → Class A after 1 year and the Class A exam. Method 6 on 6-G is the Class A upgrade line (B ≥1 year or C ≥4 years). Do not invent a “90-day Class B upgrade.”

A foreman on this form is not a courtesy title on a business card. The statute describes a foreman as in charge of a group of workers and usually responsible to a superintendent or contractor. A lead technician who directed helpers, assigned tasks, and was the job-site decision maker can document that year; a helper who never ran a crew cannot relabel three helper years as foreman time. List employer name and address, dates, phone, employer's license number , a contact, and the work (air-conditioning equipment, heating, refrigeration, sheet metal ductwork, and — for Class A — systems over 25 tons / 500,000 BTU).

Financial responsibility and financial stability (61G4-15.006, effective 5/5/2024)

The rule splits two grounds for refusal.

Financial responsibility: you must provide a current consumer credit report (as defined in 61G4-12.011) that does not disclose any unsatisfied judgments or liens against you. There must also be no unsatisfied judgments or liens against the business entity you previously qualified as primary qualifier or that you have applied to qualify. Satisfied items that still print on the report need proof of satisfaction, and bankruptcies need discharge proof, as the 6-G instructions describe.

Financial stability: proof of a credit score, FICO derived, of 660 or higher . Applicants who cannot provide 660 or higher meet stability by completing a 14-hour financial responsibility course approved by the Board .

Both responsibility and stability can be met with one clean current credit report that has a FICO-derived 660 or higher and no unsatisfied judgments or liens (again including the business entity). A 680 score with an open $8,000 materialman's judgment is not a pass — the judgment kills responsibility even though 680 clears the stability number. A 640 score with a clean report still needs the 14-hour course for stability. The old “660 bond” alternative is not the current (5/5/2024) rule; do not study a letter-of-credit workaround as if it still substitutes for the course.

Insurance (61G4-15.003) and workers' compensation

As a prerequisite to initial issuance, renewal of an active certificate, or a status change, the applicant attests to public liability and property damage insurance in the Board's amounts, maintained for the life of an active certificate. For Air Conditioning contractors the table is $100,000 public liability and $25,000 property damage. That is the same floor as mechanical, roofing, plumbing, and most other Division II trades. It is not the General/Building contractor floor of $300,000 / $50,000.

The certificate holder on the Certificate of Insurance must be the State of Florida, Department of Business and Professional Regulation, the Construction Industry Licensing Board . The COI must show the issuing date, agent, exact business-organization name (and d/b/a), insurer, policy number, effective date, expiration date, and those aggregate amounts. Naming only a municipality, or only “DBPR” without CILB, is how a file stalls.

Workers' compensation follows Chapter 440 , Florida Statutes, or a valid exemption. Construction employers with employees generally must carry coverage; officer exemptions are a Division of Workers' Compensation process, not a CILB waiver of job-site reality. Commercial contracts often demand $1 million liability — that is a contract minimum, not the license minimum. The exam tests the Board numbers.

  • Gate Current official bar
  • Age / character 18; good moral character (F.S. 489.111)

Experience One 6-G / 489.111 method; 2,000 hours = 1 year; Class A should show >25 tons / 500,000 BTU for one year

  • Credit — responsibility No unsatisfied judgments or liens (person and entity)
  • Credit — stability FICO-derived 660+ , or Board-approved 14-hour course if below 660
  • Liability insurance $100,000 public liability / $25,000 property damage; holder State of Florida, DBPR, CILB
  • Workers' compensation Chapter 440 or valid exemption
  • Exams Both Division II sittings at 70% , fees confirmed at PTI/Pearson VUE registration

After the exams, the license application still needs electronic fingerprints (FDLE/FBI), the experience affidavits, and the insurance/credit package. Certified licenses renew August 31 of even-numbered years with 14 hours of Board-approved continuing education per biennium (at least one hour each of workplace safety, workers' compensation, business practices, advanced-module building code, and laws and rules) under F.S. 489.115 and 61G4-18.001 — you will study that block later; do not skip CE planning once the certificate issues.

Florida scenario: Miami-Dade lead installer, 640 FICO, four documented years

Andre has been a mechanic in Miami-Dade for three years and a foreman for one year directing two helpers on changeouts and light commercial splits. He wants certified Class B first. Method 5 on CILB 6-G fits: four years as worker or foreman with at least one year as foreman , and 2,000 hours per year. His credit report shows a FICO-derived 640 and no unsatisfied judgments or liens . 61G4-15.006(1) responsibility is met. 61G4-15.006(2) stability is not : 640 is below 660 , so he must complete the Board-approved 14-hour financial responsibility course . He cannot “bond around” the score under the 5/5/2024 rule. He also needs a COI with $100,000 / $25,000 and State of Florida, DBPR, CILB as holder — not a homeowner policy and not a COI that names only the City of Miami. If he later upgrades to Class A, Method 6 requires an active Class B for at least one year plus the Class A trade exam, and the Class A employment checkboxes will look for one year on systems over 25 tons / 500,000 BTU .

Traps: (1) Counting helper years as foreman years. (2) Treating 659 as “close enough” to 660 — it is not; take the 14-hour course. (3) Ignoring an unsatisfied lien because the FICO number is high. (4) Using GC insurance limits or omitting CILB from the certificate holder. (5) Assuming the Pearson VUE printout is the license.