Study guide
4.3 Determining Outsourced Services
Florida HVAC Contractor License Class A/B
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts & License Classes 1.2 Exam Format, Open-Book Rules & Pearson VUE 1.3 Eligibility, Experience Paths & Financial Responsibility
2 Establishing the Contracting Business
2.1 Business Organizational Structure 2.2 Business Plan, Marketplace & License Scope 2.3 Professionals, Fixed Assets & Bonding
3 Insurance for Florida HVAC Contractors
3.1 Obtaining Insurance (GL, Workers' Compensation & Bonds) 3.2 Coverages, Limits & Policy Language 3.3 Maintaining Insurance & CILB Certificate-Holder Rules
4 Overhead, Staffing & Markets
4.1 Developing the Business, Staffing & Markets 4.2 Determining Business Overhead (FICA, FUTA, SUTA, Workers' Comp, Rent & Utilities) 4.3 Determining Outsourced Services
5 Bids, Proposals & Estimating
5.1 Preparing Bids and Proposals 5.2 AIA Documents, Offers & Contract Components 5.3 Labor Productivity, Overhead & Project Costing
6 Purchasing, Invoices, Draws & Safety Programs
6.1 Purchasing Materials, UCC & Inventory (FIFO) 6.2 Invoices, Draw Requests & Percentage of Completion 6.3 Developing a Safety Program (OSHA, SDS & Drug Testing)
7 Managing Contracts
7.1 Contract Law, Scope & Completion Schedules 7.2 Florida Lien Law Inside Contracting 7.3 Mediation, Arbitration, Tort Law & Risk
8 Managing Trade Operations
8.1 Scheduling Trade Operations (CPM, RFI & Submittals) 8.2 OSHA Records, Document Retainage & Penalties 8.3 Takeoffs, Equipment Lease vs Purchase & Inventory
9 Accounting I: Receivables, Payables & Cash
9.1 Managing Accounts Receivable 9.2 Managing Accounts Payable & Discounts 9.3 Cash Flow, Banking & Financial Ratios
10 Accounting II: Taxes, Job Cost & Payroll
10.1 Filing Tax Forms & Returns 10.2 Tracking Job Costs 10.3 Payroll, Employment Taxes & Garnishments
11 Managing Human Resources
11.1 Hiring, I-9, Background Checks & Discrimination 11.2 HR Policies, OSHA & Drug-Test Chain of Custody 11.3 Evaluating Employees
12 Florida Contractor Law: Chapter 489 & 61G4
12.1 Chapter 489: Certified vs Registered & Qualifying Agents 12.2 61G4 Board Rules, Advertising & Discipline 12.3 Qualifying Agent Duties, Supervision & Additional Entities
13 Florida Construction Lien Law (Chapter 713)
13.1 Construction Lien Overview & Claimants 13.2 Notices to Owner, Time Limits & Perfecting Liens 13.3 Payment Bonds, Waivers & Claims of Lien
14 Financial Responsibility, CE & Federal Rules
14.1 Financial Responsibility & the 660 FICO Rule 14.2 Continuing Education & Biennial Renewal 14.3 Federal Employment, Immigration, OSHA & Environmental Rules
15 Plans, Specs & Equipment Selection
15.1 Reading Plans, Specifications, Symbols & Scales 15.2 Recommending Plan Changes & Equipment Types 15.3 EER, SEER, ARI Listings & Cost Effectiveness
16 Energy Codes, Loads & Thermal Resistance
16.1 Florida Energy Codes, R-Values & U-Factors 16.2 Determining HVAC Heating & Cooling Loads 16.3 Applying Energy Conservation, Fan Curves & Pump Curves
17 HVAC System & Duct Design
17.1 Designing HVAC Systems (Psychrometrics, Enthalpy & Airflow) 17.2 Designing Duct Systems & Insulation 17.3 Selecting Equipment, Location & Codes
18 Piping, Pumps, Boilers, Controls & Rigging Design
18.1 Pipe Sizing, Valves, Fittings, Sealants & Layout 18.2 Control Requirements, Fan Motors, CFM & Compressor Capacity 18.3 Pumps, Boilers, Steam, Fuel & Pipe Insulation 18.4 Grease Ducts, Live Loads, Rigging & Mechanical Equipment
19 Sheet Metal Duct Fabrication
19.1 Fabricating Rectangular & Round Ducts 19.2 Seams, Locks, Taping, Mastics & Liners 19.3 Fittings, Outlets & Grilles 19.4 Kitchen Hoods, Exhausts & Drain Pans
20 Split, Package & Heat Pump Installation
20.1 Installing Split & Package Air Conditioners 20.2 Installing Split & Package Heat Pumps 20.3 Air-Cooled vs Water-Cooled Systems
21 Large Systems, Chillers & Towers
21.1 Installing by Tonnage & Class A vs Class B Limits 21.2 Chilled Water, Water Towers & Secondary Coolant 21.3 Centrifugal, Absorption & Ammonia Systems
22 Refrigeration, Coolers, Ventilation & Controls Install
22.1 Low, Medium & Ultra-Low Temperature Systems & EPA Rules 22.2 Walk-In & Reach-In Coolers 22.3 Ventilation, Exhaust, Makeup Air, Grease Ducts & Kitchen Exhaust 22.4 Geothermal, Pneumatic & DDC Controls, TAB & Smoke Tests
23 Condensers, Compressors & Air Handlers
23.1 Installing Air-Cooled & Water-Cooled Condensers 23.2 Hermetic, Semi-Hermetic & Centrifugal Compressors 23.3 Air Handlers, Evaporators, Heat Exchangers, Receivers & Heat Strips
24 Duct, Fans, Filters & Terminals
24.1 Installing Sheet Metal, Fiberglass & Flexible Duct 24.2 Fans, Blowers, Motors, Grilles, Registers & Fire Dampers 24.3 Filters, Flues, Warm-Air, Gas & Fuel-Oil Appliances
25 Refrigerant Piping & Joining
25.1 Refrigerant Piping, Copper Tubing & Pipe Sizing 25.2 Brazing, Welding, Flaring, Swaging & Soldering 25.3 Steel Pipe, Plastic Pipe, Threading & Oxy-Acetylene 25.4 Hangers, Supports, Horizontally Supported Piping & Pressure Testing
26 Metering Devices & Line Components
26.1 TXVs, Capillary Tubes, Reversing Valves & Metering Devices 26.2 Liquid, Suction & Heat-Pump Dryers, Filters & Oil Traps 26.3 Receivers, Heat Strips, Gas/Oil Appliances & Related Accessories
27 Controls Installation
27.1 Pressure, Temperature, Humidity & Bellows Controls 27.2 Thermostats, Humidistats, Pneumatic & Solid-State Controls 27.3 Transformers, Capacitors, Contactors, Relays & Safety Disconnects 27.4 Defrost Components, Starters, Solenoids & Limit Switches
28 Motors, Wiring & Electrical Installation
28.1 Wiring Single-Phase & Three-Phase Equipment 28.2 Motor Types, Protection, Controllers, Belts & Pulleys 28.3 Geothermal Loops, Surge Protectors, Phase Monitors & Plastic Pipe
29 Diagnostic Analysis: Refrigeration
29.1 Pressure-Enthalpy Diagrams & Operating Pressures 29.2 Air Volumes, Enthalpy, Wet-Bulb & Dry-Bulb 29.3 Leak Detection & Refrigeration Test Instruments
30 Diagnostic Analysis: Electrical & Instruments
30.1 Current Draw, Voltage, Power & Motor Terminals 30.2 Testing Relays, Capacitors, Starters, Transformers & Defrost Stats 30.3 Using Amprobes, Velometers, Pitot Tubes, Manometers & Gauges
31 Recovery, Repair & Calibration
31.1 Nitrogen & Gas Regulators, Recovery & Retrofit 31.2 Repairing Hermetic, Semi-Hermetic, Centrifugal Compressors & Blowers 31.3 Calibrating Thermostats, Pressure Switches & Pneumatic Controls 31.4 Superheat, Safety Cutouts, Defrost Clocks & Freezer Controls
32 Mechanical Service & Cleaning
32.1 Belts, Pulleys, Motor Rotation & Seized Compressors 32.2 Crankcase & Evaporator Pressure Regulators & Unloaders 32.3 Cleaning Towers, Condensers, Foreign Matter & Condensate Drains
33 Jobsite Safety & Equipment
33.1 PPE: Hearing, Head, Eye, Face & Respiratory Protection 33.2 Lockout/Tagout, Warning Signs, Toxic Materials & Ventilation 33.3 Rigging, Hoists, Cranes, Forklifts, Backhoes & Excavation 33.4 Ladders, Scaffolds, Tools & Air Compressors
34 Energy Management
34.1 Envelope, Duct Pressure & Blower-Door Testing 34.2 Efficient Equipment, Zoning, ERVs, Wi-Fi Thermostats & Green Buildings 34.3 Energy Forms, R/U Factors, Window Heat Gain & Florida Load Calcs
35 Indoor Air Quality
35.1 Ventilation, Filtration, Humidity, UV & Air Cleaners 35.2 Contaminants, Source Control, TAB & Human Health Effects
4.3 Determining Outsourced Services
Key Takeaways Explain This Topic AI
A true HVAC subcontract is a licensed specialty contractor with its own employees, tools, and Chapter 440 coverage or exemption; that invoice is a direct job cost, not a way to hide labor burden.
Air-conditioning electrical authority is limited: single-phase work on a dedicated existing disconnect, dedicated HVAC-circuit repairs with a breaker lock, and low-voltage HVAC controls — new three-phase power wiring is licensed electrical-contractor work.
Class B cannot outsource around the 25-ton / 500,000 Btu per-system cap; F.S. 489.113(9) majority-of-the-work priming does not split one oversized system into legal Class B pieces.
Rooftop and chiller sets typically outsource crane work to an OSHA 29 CFR 1926 Subpart CC operator; sealed structural or mechanical drawings that law or specifications require must be signed by a Florida licensed professional engineer.
EPA Section 608 recovery may be outsourced when the shop lacks certified technicians or large-system recovery equipment, but venting remains illegal and the HVAC contractor of record still owns the job.
Last updated: August 2026
4.3 Determining Outsourced Services
Area B's outsourced services item asks when a Florida HVAC contractor should buy a specialty instead of hiring it. The Contractors Manual and Builder's Guide to Accounting treat the decision as license scope plus job-cost structure. A legitimate subcontractor invoice is a direct job cost . A helper you control who invoices you on a 1099 is still an employee from section 4.1. Outsourcing does not erase qualifying-agent supervision under F.S. 489.1195, and it does not expand Class B capacity.
Keep versus buy: the decision rule
Outsource when all of the following are true:
The work is outside the air-conditioning license , or inside the license but beyond the shop's equipment, certification, or peak-season capacity .
The vendor is a properly licensed contractor (or a Florida professional engineer (PE) for sealed work) with workers' compensation or a valid exemption and general liability.
You can supervise , inspect, and warrant the interface — the curb, the disconnect, the duct connection, the refrigerant charge — because the CILB qualifier still owns the job.
The subcontract price, plus your markup for supervision, warranty, and overhead, still fits the estimate.
Keep the work in-house when it is core HVAC labor you already burden (W-2 techs, recovery machines, brazing, start-up) and when teaching a helper is cheaper than a specialty minimum. August overtime on W-2 techs is often cheaper than a panic subcontract after a hurricane — until the work is electrical, structural, or over Class B tonnage , at which point overtime cannot cure a license problem.
Electrical work beyond HVAC statutory limits
F.S. 489.105(3)(f)–(g) give air-conditioning contractors a narrow electrical grant , not an electrical license. You may:
Replace, disconnect, or reconnect power wiring on the line or load side of the dedicated existing electrical disconnect on single-phase systems.
Repair or replace power wiring, disconnects, breakers, or fuses for dedicated HVAC circuits with proper use of a circuit-breaker lock .
Install, disconnect, and reconnect low-voltage HVAC control wiring .
Install a condensate drain to an existing safe waste or other approved disposal other than a direct connection to a sanitary system .
You may not run potable water , sanitary sewer , pool piping , or electrical power wiring beyond those HVAC exceptions. You may not install liquefied petroleum or natural gas fuel lines within buildings except disconnect/reconnect of those appliances on a changeout. Three-phase power wiring, a new circuit from a panel that is not a dedicated existing HVAC disconnect, service-entrance work, and lighting are electrical-contractor work. Outsource them. Putting a 1099 “electrician” who is not licensed on your rooftop is unlicensed contracting stacked on misclassification.
Class A and Class B share this electrical limit. Unlimited tonnage is not unlimited voltage or phase .
Sheet metal, crane, recovery, and engineering
Sheet metal. Residential changeouts often use factory plenums, flexible duct, and ductboard that W-2 installers can set to SMACNA and Florida Building Code — Mechanical 2023 rules. Large commercial rectangular duct, kitchen grease duct (NFPA 96), and pressure-class duct that must be fabricated in a shop are frequently outsourced to a licensed sheet-metal contractor . That sub brings a brake, a plasma table, and workers' compensation on sheet-metal classes. Paying a helper to roll duct on your shop brake after hours is not a sheet-metal subcontract; it is more W-2 payroll (and possibly a different workers' compensation class). If the HVAC firm has a real sheet-metal shop and W-2 mechanics, keep it — and burden it.
Crane and rigging. Setting a packaged rooftop or an air-cooled chiller is a lift. OSHA 29 CFR 1926 Subpart CC governs cranes in construction. Most HVAC shops do not own a crane or a certified operator. Outsource the lift to a crane company, require proof of operator qualification, and treat the invoice as a job cost . After a Florida hurricane, crane minimums spike; that is a bid input, not a surprise. Class A jobs over 25 tons are where this cost becomes routine. Class B still sees 5-ton rooftop packages that need a picker or crane; the license class does not remove the lift hazard.
Refrigerant recovery. EPA Section 608 technician certification is federal and is not a substitute for a CILB license. Venting is prohibited. If your W-2 crew is 608-certified and you own recovery machines sized for 3–20 ton work, keep recovery in-house. Outsource when you lack certified techs, when a replacement involves a large chiller or centrifugal charge your machines cannot hold, or when a specialty recovery contractor is the only legal way to pull a retired R-22 or high-charge plant. The HVAC contractor of record still documents the recovery. Outsourcing the tank does not outsource the EPA duty.
Engineering and PE stamps. F.S. 489.105 lets an air-conditioning contractor design systems if not prohibited by law . Residential Manual J / S / D load and equipment selection is ordinary contractor design. When the project specifications or Florida law require drawings signed and sealed by a Florida licensed professional engineer (Chapter 471) — rooftop structural loading, some commercial mechanical plans, life-safety smoke-control narratives, or energy models a building official will only accept from a PE — outsource the stamp . Do not “stamp” drawings with a contractor license. Do not let an unlicensed designer impersonate a PE. Class A design of boilers and pressure vessels is still not a PE license.
Class B cannot subcontract around capacity
F.S. 489.113(9)(a) allows a contractor to act as prime when the majority of the work under the contract is within the license, subcontracting remaining licensed trades (electrical, plumbing, roofing, sheet metal). That rule lets a Class A HVAC prime hire an electrician for three-phase power. It does not let a Class B HVAC contractor take a 40-ton chiller as prime and hire a Class A friend to “be the license” on the same system. Capacity is in any one system . Outsourced services cannot launder tonnage.
A Class B shop that wins a campus of 20-ton rooftops plus one 40-ton chiller should bid the 20-ton work and let the owner contract the chiller to a Class A or mechanical contractor — or the Class B qualifier must not take the campus as a single HVAC contract. Joint ventures are themselves business organizations that must be qualified (F.S. 489.119). Handshake “we'll put it on their ticket” is how 489.127 items are written.
Accounting: subcontracts are cost of sales, not overhead
Builder's Guide: a subcontract on a named job is a direct cost (cost of sales). It is not rent. It still needs:
A written subcontract (AIA A401-2017 is on the 2026 B&F list for this reason).
License, certificate of insurance , and workers' compensation or exemption before the sub steps on the roof (F.S. 440.10).
Your markup for supervision, warranty, punch, and general overhead . Passing through a crane invoice at cost with no markup is how overhead from section 4.2 goes unrecovered.
Retainage and lien-law notices if you are not in privity with the owner — Chapter 713 is a later chapter; the Area B point is that unpaid subs become your problem.
A professional employer organization (PEO) or payroll service is a different outsource: Circular E warns that you remain responsible for employment taxes if a third party fails to deposit. A certified professional employer organization (CPEO) has special IRS status; an ordinary payroll vendor does not take your Form 941 liability away. Do not outsource payroll in order to pretend you have no employees.
Work Keep in-house when Outsource when License / credential Job-cost treatment
3–5 ton changeout labor W-2 installers exist Peak-season capacity is gone and the vendor is a licensed HVAC contractor with WC CILB A or B matching system size Direct labor or HVAC subcontract
Sheet-metal shop duct You have W-2 mechanics and a shop SMACNA / grease duct / volume exceeds the shop Sheet-metal contractor Direct subcontract
Power wiring Single-phase dedicated existing disconnect; HVAC-circuit repair with breaker lock; low-voltage controls Three-phase, new panel circuits, service, lighting Electrical contractor Direct subcontract
Rooftop / chiller set You own a rated lift and qualified operator You do not; almost always on large equipment Crane company; OSHA 1926 Subpart CC Direct job cost
Recovery 608-certified W-2 techs and sized machines Large charge, missing 608 cards, specialty plant EPA 608 technicians Direct labor or recovery subcontract
Sealed drawings / rooftop structure Ordinary contractor design not prohibited Specs or law require a PE seal Florida PE (Ch. 471) Direct professional fee
System over 25 tons / 500k Btu You are Class A You are Class B — do not take the system Class A or mechanical Not a Class B subcontract trick
Florida HVAC scenario
Harbor Class A Mechanical, Inc. in Miami-Dade wins replacement of an 80-ton air-cooled chiller on a three-story condominium. The qualifier maps outsourced services before the bid, not after the crane is late:
Engineering. The existing dunnage may not take the new operating weight. A Florida PE stamps a rooftop structural letter. That fee is in the bid.
Electrical. The new chiller is three-phase . The existing disconnect must be replaced from the switchgear. Harbor's HVAC electrical grant does not cover that feeder. A licensed electrical contractor is named in the bid.
Crane. Saturday morning lift, OSHA 1926 Subpart CC operator, Miami-Dade street permit. Job cost, with weather contingency.
Sheet metal. New 6,000 cfm supply mains in rectangular metal, seal class required by energy code. A licensed sheet-metal contractor fabricates to SMACNA HVAC Duct Construction, 4th edition (2020).
Recovery. The old plant still holds a large charge. Harbor's 608 techs own the recovery; they rent additional recovery cylinders rather than venting. Cylinder rental is a job cost.
Staffing. Harbor uses W-2 lead installers for set, pipe, and start-up. It does not 1099 the electrician's helpers or the crane oiler.
If Harbor were Class B , the correct outsource decision would be not to bid the 80-ton chiller at all . Hiring a Class A company as a “sub” would not make Class B the legal contractor of record on that system. Determining outsourced services includes knowing when the only honest service to outsource is the entire job to a firm whose license matches the tons.