Study guide

8.5 Engineered Wood, I-Joists, Trusses & Connectors

Georgia General Contractor Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 0: Exam Orientation, Blueprint & Open-Book Method

0.1 Official Exam Facts, Content Outlines & Approved References 0.2 Open-Book Navigation, Reference Indexing & Study Plan

2 Chapter 1: Georgia Contractor Licensing & Regulatory Law

1.1 Board Authority & Commercial General Contractor Tiers 1.2 Scope, Exemptions & Unlicensed Contracting 1.3 Eligibility, Experience Requirements & Qualifying Agents 1.4 Financial Responsibility, Net Worth, Surety Bonds & Insurance 1.5 License Renewal, No-CE Rule & Disciplinary Actions

3 Chapter 2: Georgia Construction & Lien Law

2.1 Georgia Mechanics & Materialmen's Liens 2.2 Project Notices: Notice of Commencement, Notice to Contractor & Preliminary Notice 2.3 Statutory Lien Waivers & Affidavits of Nonpayment 2.4 Georgia Prompt Pay Act & Right to Repair Act

4 Chapter 3: Business Organization, Financial Management & Taxes

3.1 Business Entity Selection & Joint Ventures 3.2 Georgia Entity Registration, Foreign Qualification & Trade Names 3.3 Construction Accounting, WIP & Financial Statements 3.4 Cash Flow, Working Capital & Construction Banking 3.5 Federal, Georgia & Payroll Tax Administration 3.6 Worker Classification, Wage-and-Hour & Prevailing Wage

5 Chapter 4: Construction Contracts, Bidding & Risk Management

4.1 Contract Pricing Models & Cost Risk 4.2 Project Delivery Methods & Responsibility 4.3 Essential Contract Clauses & Risk Allocation 4.4 Standard Documents: AIA, ConsensusDocs & EJCDC 4.5 Quantity Takeoff, Direct Cost & Markup 4.6 Bid Scope Review, Submission & Withdrawal 4.7 Surety Bonds, Insurance & Risk Management

6 Chapter 5: Project Management, Scheduling & Quality Control

5.1 Project Planning, WBS, Logic & Resources 5.2 CPM, Float, Updating & Schedule Compression 5.3 Project Administration, Submittals, RFIs & Records 5.4 Changes, Delays, Claims & Dispute Resolution 5.5 QA/QC, Special Inspections & Closeout

7 Chapter 6: Georgia Building Codes, Environmental Regulations & Site Work

6.1 Current Georgia Codes, Amendments, Permits & Inspections 6.2 Occupancy, Construction Type, Egress & Accessibility 6.3 GESA, NPDES, Buffers, BMPs & Certified Personnel 6.4 Survey Control, Layout, Clearing & Site Preparation 6.5 Excavation, Earthwork Volumes, Hauling & Compaction 6.6 Shallow Foundations, Slabs, Deep Systems & Drainage

8 Chapter 7: Concrete & Masonry Construction

7.1 Concrete Materials, Mix Design & Field Testing 7.2 Concrete Placement, Hot/Cold Weather, Curing & Defects 7.3 Formwork, Shores, Reshores & Removal 7.4 Reinforcing Steel, Splices & Post-Tensioning 7.5 Masonry Units, Mortar, Grout & Testing 7.6 Masonry Walls, Reinforcement, Flashing & Movement Joints

9 Chapter 8: Structural Steel, Metals & Framing Systems

8.1 Structural Steel Shapes, Framing & Erection Stability 8.2 Bolted Connections, Welding & Nondestructive Testing 8.3 Steel Joists, Deck & Cold-Formed Framing 8.4 Heavy Timber, Fire Performance & Mass Timber 8.5 Engineered Wood, I-Joists, Trusses & Connectors 8.6 Wood Framing, Sheathing, Bracing & Fastening

10 Chapter 9: Building Envelope, Thermal & Moisture Protection, Doors & Windows

9.1 Low-Slope Roofing, Insulation & Drainage 9.2 Steep-Slope Roofing, Sheet Metal & Flashing 9.3 Insulation, Air Barriers & Vapor Control 9.4 Commercial Doors, Frames, Hardware & Fire Assemblies 9.5 Windows, Storefronts & Curtain Walls 9.6 Insulating Glass, Safety Glazing & Water Control

11 Chapter 10: Finishes, Mechanical, Electrical & Plumbing Coordination

10.1 Gypsum Assemblies, Ceilings & Finish Coordination 10.2 Concrete Moisture, Flooring & Tile Assemblies 10.3 HVAC, Ductwork, Dampers & Mechanical Coordination 10.4 Plumbing, DWV, Venting & Backflow 10.5 Fire Sprinklers, Standpipes & Fire Department Connections 10.6 Electrical Distribution, Grounding & Emergency Systems

12 Chapter 11: Construction Safety & OSHA Standards (29 CFR Part 1926)

11.1 OSHA Authority, Inspections, Reporting & Multi-Employer Sites 11.2 Fall Protection, Clearance Planning & Scaffolds 11.3 Excavation, Protective Systems & Trench Safety 11.4 Hazard Communication, Silica, Temporary Power & PPE 11.5 Cranes, Rigging, Signal Persons & Power-Line Safety

8.5 Engineered Wood, I-Joists, Trusses & Connectors

Key Takeaways Explain This Topic AI

Engineered wood products follow manufacturer and design-professional instructions.

I-joist flange cuts and unapproved web openings are prohibited.

Trusses require erection bracing and permanent bracing shown in the construction documents.

Last updated: August 2026

  • 8.5 Engineered Wood, I-Joists, Trusses & Connectors
  • Engineered Wood Products (EWP)

Engineered wood products are manufactured by bonding wood strands, veneers, or dimensional lumber with waterproof structural adhesives (phenol-resorcinol or polyurethane) under high heat and pressure.

1. Glued Laminated Timber (Glulam - ANSI A190.1)

Glulam members consist of individual 1-1/2" thick (nominal 2x) or 3/4" thick (for curved members) kiln-dried wood laminations oriented with grain running parallel longitudinally.

Balanced vs. Unbalanced Layups:

Unbalanced Layup (Simple Spans): The highest-grade, highest-tensile wood laminations are concentrated on the bottom (tension) face , while lower-grade laminations occupy the compression zone. Unbalanced glulams are stamped "TOP" on the compression edge; installing an unbalanced beam upside down results in severe structural deficiency.

Balanced Layup (Continuous Spans & Cantilevers): Features equal high-grade tension laminations on both top and bottom faces, accommodating bending moment reversals over intermediate support columns.

Appearance Grades:

Industrial Grade: Surfaced for utility; knots and imperfections remain open; used in concealed framing or industrial warehouses.

Architectural Grade: Surfaced smooth with open knots filled and voids puttied; standard choice for exposed commercial applications.

Premium Grade: Highest aesthetic grade with all knots filled and wood surfaces selected for uniform color; used in high-end civic and commercial showpieces.

Manufacturing Camber: Glulam beams are built with an engineered upward curve (camber) to counteract dead load deflection, typically designed for 1.5 to 2.0 times calculated dead load deflection .

2. Structural Composite Lumber (SCL)

Laminated Veneer Lumber (LVL): Produced by stacking thin wood veneers (1/10" to 1/8" thick) coated with waterproof adhesive, with the grain of all veneers running parallel in the longitudinal direction. LVL eliminates natural defects (knots, splits, grain slope), yielding high bending strength ( F b F_b F b ​ up to 2,800–3,100 psi) and exceptional dimensional stability for headers, primary beams, and I-joist flanges.

Parallel Strand Lumber (PSL / Parallam): Manufactured from long veneer strands (up to 8 feet in length) bonded parallel under pressure. Possesses superior compressive and tensile capacity; ideal for heavily loaded interior columns and long-span beams.

Laminated Strand Lumber (LSL): Formed from shorter wood strands (4" to 12"); widely used for rim boards, wall studs, and headers.

3. Prefabricated Wood I-Joists & Strict Web Hole Cutting Rules

Wood I-joists combine high-strength LVL or solid lumber top and bottom flanges with a vertical oriented strand board (OSB) or plywood web. WOOD I-JOIST HOLE CUTTING RULES

  • ◄─── HIGH SHEAR ZONE ───►◄────── LOW SHEAR / MOMENT ZONE ──────►◄─── HIGH SHEAR ZONE ───►
  • ┌────────────────────────────────────────────────────────────────────────────────┐
  • FLANGE │ ██████████████████████████████████████████████████████████████████████████████ │
  • ├──────────────────────────┐ ┌──────────────────────────────────┤
  • │ NO HOLES PERMITTED │ ALLOWED HOLE │ NO HOLES PERMITTED │
  • WEB │ NEAR SUPPORTS │ (CENTER) │ NEAR SUPPORTS │
  • │ (High Shear Zone) │ ○ Diameter │ (High Shear Zone) │
  • ├──────────────────────────┘ ≤ Depth - 2*Flg └──────────────────────────────────┤
  • FLANGE │ ██████████████████████████████████████████████████████████████████████████████ │
  • └────────────────────────────────────────────────────────────────────────────────┘
  • ▲ ▲
  • BEARING BEARING ┌─────────────────────────────────────────────────────────────────────────┐
  • │ STRICT I-JOIST FIELD MODIFICATION RULES │
  • └─────────────────────────────────────────────────────────────────────────┘
  • │
  • ├─► 1. ABSOLUTE FLANGE INTEGRITY MANDATE
  • │ NEVER cut, notch, drill, bevel, or alter top or bottom flanges under

│ ANY circumstances. Flanges carry 100% of the bending tension and compression.

  • │
  • ├─► 2. WEB HOLE LOCATION (SHEAR VS. MOMENT)
  • │ Large web penetrations (HVAC ducts, plumbing) must be cut in the CENTER THIRD

│ of the span (low shear zone). Never cut large holes near bearing supports.

  • │
  • ├─► 3. MAXIMUM HOLE SIZE & SPACING

│ Maximum round hole diameter = Joist Depth minus (2 × Flange Depth + 1/2").

│ Maintain minimum spacing between holes equal to 2 × the larger hole diameter.

  • │
  • └─► 4. PRE-STAMPED KNOCKOUTS
  • Factory-perforated 1-1/2" knockouts may be tapped out anywhere along the web

for electrical wiring runs without structural calculation.

Cross-Laminated Timber (CLT) & IBC Mass Timber Tall Buildings

Cross-Laminated Timber (CLT) panels consist of 3, 5, 7, or 9 layers of solid-sawn dimensional lumber ( 2 × 4 2\times4 2 × 4 , 2 × 6 2\times6 2 × 6 , or 2 × 8 2\times8 2 × 8 ) stacked flatwise with each layer oriented orthogonally ( 90 ∘ 90^\circ 9 0 ∘ ) to adjacent layers and glued under hydraulic pressure.

IBC Mass Timber Tall Wood Building Classifications

The International Building Code incorporates three distinct Type IV sub-classifications for tall mass timber construction:

Type IV-A (Maximum 18 Stories / 270 Feet): The most stringent mass timber classification. All CLT floor panels, mass timber columns, and bearing walls must be 100% encapsulated with noncombustible materials (e.g., multiple layers of Type X gypsum board) to achieve up to a 3-hour fire-resistance rating .

Type IV-B (Maximum 12 Stories / 180 Feet): Allows a limited percentage of exposed mass timber on ceilings and interior partition walls (typically 20% of ceiling area or 40% of wall area), with the remainder encapsulated to provide a 2-hour rating.

Type IV-C (Maximum 9 Stories / 85 Feet): Permits 100% exposed mass timber ceilings, columns, and walls, relying entirely on the inherent 2-hour fire-resistance provided by the massive charring cross-section of the wood.

Structural Timber Connectors & Hardware

Modern mass timber and engineered wood structures utilize heavy-duty galvanized structural connectors:

Heavy-Duty Joist Hangers (Top-Flange & Face-Mount): Engineered cold-formed or welded 10-to-12-gauge steel brackets transferring joist shear into headers or glulam girders.

Concealed Beam Hangers: Internally routed aluminum or steel knife-plates with cross-drilled dowel pins that sit completely hidden inside mortised beam ends, providing a clean architectural look and protecting the steel connection from fire exposure.

Post Bases & Standoffs: Must provide a minimum 1-inch standoff distance above concrete slabs or exterior grade to prevent capillary moisture absorption and fungal rot.

Split-Ring & Shear-Plate Connectors: Metal rings embedded into pre-cut circular grooves in timber mating faces to transmit heavy shear loads across bolted joints.