Study guide
10.3 Transmission Lines, Characteristic Impedance, Attenuation & SWR
FCC Amateur Radio General License Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & Exam Strategy
1.1 General Class License Overview, Exam Format & Question Pool Structure 1.2 Core Study Strategies, Formula Quick Reference & Test-Taking Tactics
2 Chapter 2: Subelement G1 – Commission's Rules
2.1 General Class Band Privileges & ITU Regions 2.2 Antenna Structure Limits, Beacons & Security Rules 2.3 Transmitter Power Limits, 60-Meter Band Rules & Prohibited Transmissions 2.4 Volunteer Examiner Accreditation, Exam Administration & Remote Testing 2.5 Control Operator Categories, Repeaters, Third-Party Traffic & Station Identification
3 Chapter 3: Subelement G2 – Operating Procedures
3.1 HF Phone Operating Procedures, SSB Tuning & Phonetic Alphabet 3.2 CW Operating Procedures, Q-Signals, RIT/XIT & Split Operation 3.3 Digital Operating Procedures: FT8, JS8Call, PSK31 & RTTY 3.4 Emergency Communications, Traffic Nets, RACES, ARES & Distress Priority 3.5 Volunteer Monitor Program, HF Direction Finding & Azimuthal Maps
4 Chapter 4: Subelement G3 – Radio Wave Propagation
4.1 Solar Activity, Sunspots, Solar Flux Index & Geomagnetic Indices 4.2 Maximum Usable Frequency (MUF), Lowest Usable Frequency (LUF) & Ionospheric Layers 4.3 Skywave Propagation, NVIS, HF Scatter & Tropospheric Ducting
5 Chapter 5: Subelement G4 – Amateur Radio Practices
5.1 Station Setup, Speech Processors & Audio DSP Filters 5.2 Test Equipment: RF Wattmeters, SWR Bridges, Dummy Loads & Oscilloscopes 5.3 Radio Frequency Interference (RFI), TVI, Harmonics & Core Filtering 5.4 Station Grounding, Bonding & Lightning Protection 5.5 Mobile and Portable HF Operations, Vehicle Noise & Battery Systems
6 Chapter 6: Subelement G5 – Electrical Principles
6.1 Reactance, Impedance, Resonance & Quality Factor (Q) 6.2 Decibels, Power Calculations & RMS/Peak AC Voltage Conversions 6.3 Power Factor, Transformer Ratios & Resistive Voltage Dividers
7 Chapter 7: Subelement G6 – Circuit Components
7.1 Inductors, Toroid Cores, Crystals & Semiconductor Diodes 7.2 Transistors (BJT, FET), Voltage Regulators & Vacuum Tube Amplifiers
8 Chapter 8: Subelement G7 – Practical Circuits
8.1 Linear Power Supplies, Rectifier Circuits & Filter Capacitors 8.2 RF Filters, Oscillators (Colpitts, Hartley, Pierce) & Mixers 8.3 Superheterodyne Receivers, Direct Sampling SDRs & Transceiver Architecture
9 Chapter 9: Subelement G8 – Signals and Emissions
9.1 SSB, CW, AM & FM Modulation Principles & Carrier Suppression 9.2 Frequency Mixing, Intermodulation Distortion (IMD) & Bandwidth Standards 9.3 Digital Emission Protocols, Baudot, PSK, FSK & Symbol Rates
10 Chapter 10: Subelement G9 – Antennas and Feed Lines
10.1 Half-Wave Dipoles, Quarter-Wave Verticals & Radiation Patterns 10.2 Directional Antennas: Yagi-Uda, Cubical Quad & Phased Arrays 10.3 Transmission Lines, Characteristic Impedance, Attenuation & SWR 10.4 Antenna Tuners, Impedance Matching Networks & Baluns
11 Chapter 11: Subelement G0 – Electrical and RF Safety
11.1 RF Exposure Evaluation, Maximum Permissible Exposure (MPE) & Safety Offsets 11.2 Tower Safety, Fall Arrest Gear, Antenna Installation & AC Power Hazards
10.3 Transmission Lines, Characteristic Impedance, Attenuation & SWR
Key Takeaways Explain This Topic AI
The characteristic impedance (Z0 = sqrt(L/C)) of a transmission line is determined solely by the conductor diameters, conductor spacing, and the dielectric constant of the insulating material, independent of line length or operating frequency.
Velocity Factor (VF = v_line / c) expresses the speed of electromagnetic waves in a transmission line relative to the speed of light, ranging from 0.66 for solid polyethylene coax to 0.82-0.85 for foam coax and 0.95 for open-wire line.
Transmission line attenuation (line loss in dB/100 ft) increases proportionally with operating frequency, physical cable length, and Standing Wave Ratio (SWR).
Open-wire or window ladder line (300 to 450 ohms) exhibits extremely low dielectric loss compared to coaxial cables, making it exceptionally efficient for multi-band antenna systems operating with high SWR.
Standing Wave Ratio (SWR) measures the degree of impedance mismatch between the transmission line and the antenna load; reflected power in low-loss feedlines is not destroyed but is re-reflected toward the load.
Last updated: August 2026
10.3 Transmission Lines, Characteristic Impedance, Attenuation & SWR
A transmission line (or feedline) is the electrical conduit that transports radio frequency energy between a transmitter/receiver and an antenna system. Rather than behaving as simple DC hookup wires, transmission lines operate as distributed-parameter waveguides governed by electromagnetic field equations.
Selecting the correct transmission line, calculating its physical and electrical length, understanding line losses across frequency, and mastering the mechanics of Standing Wave Ratio (SWR) and wave reflections are critical skills tested on the FCC General Class exam. This section explores the electrical physics of coaxial cables, open-wire ladder lines, velocity factors, and power reflection dynamics.
1. Transmission Line Architecture & Characteristic Impedance ( Z 0 Z_0 Z 0 )
Every transmission line possesses distributed electrical properties distributed continuously along its entire length: inductance per unit length ( L L L ) in henrys and capacitance per unit length ( C C C ) in farads. +-----------------------------------------------------------------------------------------+
- | EQUIVALENT DISTRIBUTED CIRCUIT OF A TRANSMISSION LINE |
- | |
- | L/2 L/2 L/2 L/2 |
- | +---CCCC---------CCCC---+ +---CCCC---------CCCC---+ |
- | | | | | |
- | ---+ +--------+ +---> |
- | | | | | |
- | --- --- --- --- |
- | C --- G --- C --- G --- |
- | | | | | |
- | ----------------------------------------------------------------> |
- | |
- | Characteristic Impedance: Z0 = √(L / C) |
- +-----------------------------------------------------------------------------------------+
- Mathematical Definition of Z 0 Z_0 Z 0
For a lossless transmission line, the characteristic impedance ( Z 0 Z_0 Z 0 ) is the ratio of RF voltage to RF current of a single wave traveling down the line without reflections: Z 0 = L C Z_0 = \sqrt{\frac{L}{C}} Z 0 = C L
Physical Determinants of Z 0 Z_0 Z 0
Characteristic impedance is determined solely by the physical geometry of the conductors and the dielectric constant ( ϵ r \epsilon_r ϵ r ) of the insulating material :
Coaxial Cable: Z 0 = 138 ϵ r log 10 ( D d ) Z_0 = \frac{138}{\sqrt{\epsilon_r}} \log_{10}\left(\frac{D}{d}\right) Z 0 = ϵ r 138 lo g 10 ( d D ) Where D D D is the inside diameter of the outer shield braid, d d d is the outside diameter of the center conductor, and ϵ r \epsilon_r ϵ r is the dielectric constant of the insulator.
Parallel Open-Wire Line: Z 0 = 276 ϵ r log 10 ( 2 S d ) Z_0 = \frac{276}{\sqrt{\epsilon_r}} \log_{10}\left(\frac{2S}{d}\right) Z 0 = ϵ r 276 lo g 10 ( d 2 S ) Where S S S is the center-to-center conductor spacing and d d d is the wire diameter.
Important
Exam Rule: The characteristic impedance ( Z 0 Z_0 Z 0 ) of a transmission line depends only on conductor diameter, spacing, and dielectric material . It is completely independent of the length of the line and independent of operating frequency.
2. Velocity Factor ( V F VF V F ) & Electrical vs. Physical Length
Electromagnetic waves travel at the speed of light ( c = 300 × 10 6 m/s c = 300\times 10^6\text{ m/s} c = 300 × 1 0 6 m/s ) only in a vacuum or in air. When an electromagnetic wave travels through a solid or foam dielectric insulating material inside a cable, its propagation velocity slows down.
The Velocity Factor ( V F VF V F ) is the ratio of wave velocity along the transmission line ( v line v_{\text{line}} v line ) to the velocity of light in free space ( c c c ): V F = v line c = 1 ϵ r VF = \frac{v_{\text{line}}}{c} = \frac{1}{\sqrt{\epsilon_r}} V F = c v line = ϵ r 1 +-----------------------------------------------------------------------------------------+
- | DIELECTRIC MATERIALS & VELOCITY FACTORS |
- | |
- | DIELECTRIC MATERIAL TYPICAL VF COMMON CABLE TYPES |
- | --------------------------- ---------- ------------------------------------ |
- | Air Dielectric (Open Wire) 0.95 - 0.98 450 Ω Window Line, 600 Ω True Ladder |
- | Foam Polyethylene (FPE) 0.80 - 0.85 LMR-400, RG-8X, RG-213 Foam |
- | Solid Polytetrafluoroethylene 0.69 - 0.71 RG-142, RG-400 (Teflon) |
- | Solid Polyethylene (PE) 0.66 RG-58, RG-8U, RG-213 Solid |
- +-----------------------------------------------------------------------------------------+
- Calculating Physical Length of Transmission Line Stubs
Because the wave travels slower inside the cable, a quarter-wavelength or half-wavelength section of transmission line is physically shorter than its free-space counterpart: L physical (feet) = L free space × V F = ( 984 f MHz × Electrical Fraction ) × V F L_{\text{physical (feet)}} = L_{\text{free space}} \times VF = \left(\frac{984}{f_{\text{MHz}}} \times \text{Electrical Fraction}\right) \times VF L physical (feet) = L free space × V F = ( f MHz 984 × Electrical Fraction ) × V F
Practical Stub Calculation Example:
Calculate the physical length of an electrical quarter-wavelength ( λ / 4 \lambda / 4 λ /4 ) matching stub at 14.100 MHz 14.100\text{ MHz} 14.100 MHz using solid polyethylene coaxial cable ( V F = 0.66 VF = 0.66 V F = 0.66 ): L free space ( λ / 4 ) = 246 14.100 = 17.447 feet L_{\text{free space (}\lambda/4\text{)}} = \frac{246}{14.100} = 17.447\text{ feet} L free space ( λ /4 ) = 14.100 246 = 17.447 feet L physical = 17.447 × 0.66 = 11.51 feet L_{\text{physical}} = 17.447 \times 0.66 = 11.51\text{ feet} L physical = 17.447 × 0.66 = 11.51 feet
3. Coaxial Cable Types vs. Open-Wire / Ladder Line
Amateur operators choose between shielded coaxial cables and balanced parallel-conductor lines based on power levels, frequency, physical routing, and anticipated SWR. +-----------------------------------------------------------------------------------------+
- | COAXIAL CABLE VS. OPEN-WIRE WINDOW LINE |
- | |
- | COAXIAL CABLE (UNBALANCED 50 Ω / 75 Ω): |
- | - Shielded construction prevents RF radiation and allows routing near metal/conduits |
- | - Higher dielectric loss at high frequencies |
- | - High SWR dramatically increases internal cable heat and signal attenuation |
- | |
- | OPEN-WIRE / 450 Ω WINDOW LADDER LINE (BALANCED): |
- | - Air-insulated dielectric provides exceptionally low loss |
- | - Handles very high SWR (10:1 or higher) with virtually zero added loss |
- | - Must be suspended away from metal objects, gutters, and earth |
- +-----------------------------------------------------------------------------------------+
- Common Transmission Line Specifications Matrix
Cable Type Nominal Z 0 Z_0 Z 0 Typical V F VF V F Dielectric Type Matched Loss at 30 MHz (dB/100 ft) Matched Loss at 150 MHz (dB/100 ft) Maximum Power Handling (at 30 MHz)
RG-58 50 Ω 50\ \Omega 50 Ω 0.66 0.66 0.66 Solid PE 2.5 dB 2.5\text{ dB} 2.5 dB 5.5 dB 5.5\text{ dB} 5.5 dB ≈ 200 Watts \approx 200\text{ Watts} ≈ 200 Watts
RG-8X (Mini-8) 50 Ω 50\ \Omega 50 Ω 0.82 0.82 0.82 Foam PE 1.7 dB 1.7\text{ dB} 1.7 dB 4.5 dB 4.5\text{ dB} 4.5 dB ≈ 800 Watts \approx 800\text{ Watts} ≈ 800 Watts
RG-213 / RG-8U 50 Ω 50\ \Omega 50 Ω 0.66 0.66 0.66 Solid PE 1.1 dB 1.1\text{ dB} 1.1 dB 2.8 dB 2.8\text{ dB} 2.8 dB 1 , 500 Watts (Full Limit) 1,500\text{ Watts (Full Limit)} 1 , 500 Watts (Full Limit)
LMR-400 50 Ω 50\ \Omega 50 Ω 0.85 0.85 0.85 Foam PE 0.7 dB 0.7\text{ dB} 0.7 dB 1.5 dB 1.5\text{ dB} 1.5 dB 1 , 500 Watts (Full Limit) 1,500\text{ Watts (Full Limit)} 1 , 500 Watts (Full Limit)
RG-6 / RG-11 75 Ω 75\ \Omega 75 Ω 0.82 0.82 0.82 Foam PE 0.8 dB 0.8\text{ dB} 0.8 dB 1.8 dB 1.8\text{ dB} 1.8 dB 1 , 000 Watts 1,000\text{ Watts} 1 , 000 Watts
450 Ω \Omega Ω Window Line 450 Ω 450\ \Omega 450 Ω 0.91 0.91 0.91 Air / Poly Web ≈ 0.12 dB \approx 0.12\text{ dB} ≈ 0.12 dB ≈ 0.30 dB \approx 0.30\text{ dB} ≈ 0.30 dB > 5 , 000 Watts >5,000\text{ Watts} > 5 , 000 Watts
4. Standing Wave Ratio (SWR) & Reflection Mechanics
When a transmission line of characteristic impedance Z 0 Z_0 Z 0 is terminated in a load impedance ( Z L Z_L Z L ) that matches Z 0 Z_0 Z 0 perfectly ( Z L = Z 0 Z_L = Z_0 Z L = Z 0 ), all energy arriving at the load is absorbed and converted into radiated RF or heat. The line is said to be flat , and the voltage reflection coefficient is zero.
If Z L ≠ Z 0 Z_L \ne Z_0 Z L = Z 0 , boundary conditions dictate that the load cannot absorb all incident power. A portion of the incoming forward voltage wave ( V fwd V_{\text{fwd}} V fwd ) is reflected back toward the generator as a reflected voltage wave ( V ref V_{\text{ref}} V ref ) . +-----------------------------------------------------------------------------------------+
- | FORWARD & REFLECTED WAVE INTERFERENCE |
- | |
- | Forward Wave ===========================================> (Load ZL ≠ Z0) |
- | Reflected Wave <========================================== |
- | |
- | Composite Standing Wave: |
- | Vmax = |Vfwd| + |Vref| (Constructive Interference Node) |
- | Vmin = |Vfwd| - |Vref| (Destructive Interference Node) |
- | |
- | SWR = Vmax / Vmin |
- +-----------------------------------------------------------------------------------------+
- The Voltage Reflection Coefficient ( Γ \Gamma Γ )
The ratio of the reflected voltage wave to the forward voltage wave is the complex voltage reflection coefficient ( Γ \Gamma Γ ) : Γ = Z L − Z 0 Z L + Z 0 \Gamma = \frac{Z_L - Z_0}{Z_L + Z_0} Γ = Z L + Z 0 Z L − Z 0
Calculating Standing Wave Ratio (SWR)
The superposition of forward and reflected traveling waves creates a stationary interference pattern along the line called a standing wave . SWR is defined as the ratio of maximum RF voltage to minimum RF voltage along the line: SWR = V max V min = 1 + ∣ Γ ∣ 1 − ∣ Γ ∣ \text{SWR} = \frac{V_{\text{max}}}{V_{\text{min}}} = \frac{1 + |\Gamma|}{1 - |\Gamma|} SWR = V min V max = 1 − ∣Γ∣ 1 + ∣Γ∣
Simplified Resistive SWR Calculation
For purely resistive antenna loads ( R L R_L R L with zero reactance), SWR is easily calculated by dividing the larger resistance by the smaller resistance: SWR = R L Z 0 ( if R L > Z 0 ) or SWR = Z 0 R L ( if R L < Z 0 ) \text{SWR} = \frac{R_L}{Z_0} \quad (\text{if } R_L > Z_0) \qquad \text{or} \qquad \text{SWR} = \frac{Z_0}{R_L} \quad (\text{if } R_L < Z_0) SWR = Z 0 R L ( if R L > Z 0 ) or SWR = R L Z 0 ( if R L < Z 0 )
Examples:
If a 100 Ω 100\ \Omega 100 Ω non-reactive load is connected to a 50 Ω 50\ \Omega 50 Ω line: SWR = 100 / 50 = 2.0 : 1 \text{SWR} = 100 / 50 = \mathbf{2.0:1} SWR = 100/50 = 2.0 : 1 .
If a 25 Ω 25\ \Omega 25 Ω non-reactive load is connected to a 50 Ω 50\ \Omega 50 Ω line: SWR = 50 / 25 = 2.0 : 1 \text{SWR} = 50 / 25 = \mathbf{2.0:1} SWR = 50/25 = 2.0 : 1 .
If a 150 Ω 150\ \Omega 150 Ω non-reactive load is connected to a 50 Ω 50\ \Omega 50 Ω line: SWR = 150 / 50 = 3.0 : 1 \text{SWR} = 150 / 50 = \mathbf{3.0:1} SWR = 150/50 = 3.0 : 1 .
5. Forward Power, Reflected Power & Net Power Transfer
A common misconception is that reflected power travels back into the transmitter and instantly destroys the output transistors, or that reflected power represents permanently lost energy.
Power Relationships & Percentage Reflected
The fraction of power reflected from the load is equal to the square of the magnitude of the reflection coefficient ( ∣ Γ ∣ 2 |\Gamma|^2 ∣Γ ∣ 2 ): P reflected P forward = ∣ Γ ∣ 2 = ( SWR − 1 SWR + 1 ) 2 \frac{P_{\text{reflected}}}{P_{\text{forward}}} = |\Gamma|^2 = \left(\frac{\text{SWR} - 1}{\text{SWR} + 1}\right)^2 P forward P reflected = ∣Γ ∣ 2 = ( SWR + 1 SWR − 1 ) 2 +-----------------------------------------------------------------------------------------+
- | SWR VS. REFLECTED POWER REFERENCE TABLE |
- | |
- | SWR RATIO REFLECTION COEFF (|Γ|) % REFLECTED POWER % DELIVERED POWER |
- | --------- ---------------------- ----------------- ----------------- |
- | 1.0 : 1 0.000 0.0% 100.0% |
- | 1.5 : 1 0.200 4.0% 96.0% |
- | 2.0 : 1 0.333 11.1% 88.9% |
- | 3.0 : 1 0.500 25.0% 75.0% |
- | 4.0 : 1 0.600 36.0% 64.0% |
- | 5.0 : 1 0.667 44.4% 55.6% |
- | 10.0 : 1 0.818 66.9% 33.1% |
- | ∞ : 1 (Open) 1.000 100.0% 0.0% |
- +-----------------------------------------------------------------------------------------+
What Really Happens to Reflected Power?
In a real transmission line system:
The transmitter launches forward power ( P fwd P_{\text{fwd}} P fwd ) toward the antenna.
At the mismatched antenna feedpoint, a portion ( P ref P_{\text{ref}} P ref ) reflects back down the feedline toward the transmitter.
When the reflected wave reaches the source (or antenna tuner matching network), the impedance discontinuity re-reflects the wave back toward the antenna in phase with subsequent transmitter cycles.
Net Power Transfer: In a low-loss line (such as 450 Ω 450\ \Omega 450 Ω ladder line), nearly 100% of the net transmitter power is eventually radiated by the antenna , minus minor ohmic line heating losses after multiple reflections.
Why High SWR Hurts Coaxial Lines: In lossy coaxial lines (like RG-58), standing waves create extreme voltage and current peaks. Because I 2 R I^2R I 2 R ohmic heating and dielectric absorption increase exponentially with current and voltage, each pass of reflected power undergoes additional attenuation. On VHF/UHF or long coaxial runs, high SWR can convert most of your RF power into heat inside the cable.