Study guide

4.2 ERG Green Table and Toxic Inhalation Hazards (TIH)

NFPA 470 Hazardous Materials Awareness-Level Responder Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Recognition & Identification

1.1 DOT Placards and Labeling System 1.2 The NFPA 704 Fire Diamond 1.3 Shipping Papers and Safety Data Sheets (SDS)

2 Chapter 2: Initial Response Staging & Positioning

2.1 Scene Approach and Safe Staging 2.2 Establishing Isolation Perimeters 2.3 Evacuation and Shelter-in-Place Actions

3 Chapter 3: DOT Hazard Classes & Chemical Properties

3.1 DOT Hazard Classes 1 through 4 3.2 DOT Hazard Classes 5 through 9 3.3 Key Physical & Chemical Behavior

4 Chapter 4: Critical Reference Resources

4.1 ERG Structure and Navigation 4.2 ERG Green Table and Toxic Inhalation Hazards (TIH) 4.3 National and Local Emergency Resources

5 Chapter 5: Hazardous Material Containers

5.1 Highway Cargo Tanks 5.2 Rail Tank Cars and Intermodal Tanks 5.3 Non-Bulk Packaging & Small Containers

6 Chapter 6: Operations Boundaries & Reporting

6.1 Awareness-Level Scope and Action Boundaries 6.2 Scene Size-Up and the ICS-201 Briefing Form 6.3 Unified Command & Radio Communications

4.2 ERG Green Table and Toxic Inhalation Hazards (TIH)

Key Takeaways Explain This Topic AI

Initial isolation applies around the source; protective-action distances describe a separate downwind area.

ERG small spills involve 208 litres (55 US gallons) or less and can include a small leak from a large package; container capacity alone is insufficient.

Current Table 1 chlorine small-spill values are 60 metres (200 feet) of isolation, with separate day/night downwind distances; large spills refer to Table 3.

Table 2 is information about toxic gases generated in water; those gases are already considered in the associated Table 1 distances.

For fire, use the applicable orange fire isolation information plus the relevant green downwind protection for residual release, within qualified incident decisions.

Last updated: October 2026

Use the green tables as a conditional reference

Green highlighting in ERG2024 identifies material requiring additional toxic-inhalation or specified water-reactive toxic-gas guidance. It does not establish a single isolation distance, make the orange guide optional or qualify every responder to carry out an evacuation. Awareness study should teach the candidate to find and explain the applicable information, recognise uncertainty and communicate through the emergency plan.

The tables model initial protective information for transportation incidents. They do not predict the precise outline or concentration of every real plume. Actual weather, terrain, release conditions and incident assessment still matter. Before using a numerical answer in a classroom question, identify the material, guide, applicable row or table, spill category and requested direction. Never interpret a bare number without its units and conditions.

Separate the two kinds of distance

Initial isolation describes an area around the release source, in all directions. Protective action describes a separate downwind area where people may need appropriate protective measures. These terms are not synonyms. A downwind number does not automatically become the radius of an all-directions circle, and the isolation number does not replace the potentially longer downwind distance.

Protective measures may involve evacuation or sheltering according to the incident assessment and plan. The table is not an instruction for an awareness-only person to approach the material, make an unauthorised entry or independently direct public movement. Your task may be to report the reference information and undertake assigned non-intervention scene-security duties from a safe position.

Table 1 and spill classification

Table 1 lists materials by identification number and name, with initial-isolation and downwind values. Read qualifiers, including entries limited to material spilled in water. The table separates small/large spills and day/night downwind conditions; some large-spill entries direct the reader to Table 3 instead of giving one generic large-spill number.

The guide's background defines small spills as 208 litres (55 US gallons) or less . Its table heading includes a small package or a small leak from a large package . Large spills involve greater quantities, a large-package release or many small packages. The volume of the tank by itself does not prove the quantity released or justify assigning every minor leak to the large-spill column. If the necessary conditions are unknown, state that uncertainty and seek qualified assistance.

A current chlorine Table 1 exercise

For a specified small chlorine spill, UN1017, without fire , the actual ERG2024 Table 1 row gives:

  • Requested information Published value
  • Initial isolation in all directions 60 metres (200 feet)
  • Downwind protective action, day 0.3 kilometres (0.2 mile)
  • Downwind protective action, night 1.5 kilometres (0.9 mile)
  • Large chlorine spill Refer to Table 3

These are the printed paired units, rounded for the reference. They are not exact mathematical unit equalities. For example, 60 metres is about 197 feet; the guide pairs it with 200 feet. The 0.3 and 1.5 kilometre values differ by a factor of five in this particular row. That does not establish a universal night/day multiplier for every material, container or weather condition.

Day and night are separate modelling conditions because atmospheric mixing can differ. The table uses day between sunrise and sunset and night between sunset and sunrise. Temperature inversions, terrain, wind and other circumstances can complicate actual dispersion. Do not memorise that every nighttime plume is exactly three, five or ten times longer.

Table 2 is generated-gas information

Table 2 identifies toxic gases produced when specified water-reactive materials are spilled in water. Its information explains the hazard behind the applicable reference entry. The associated Table 1 distances already account for those generated gases.

Therefore, Table 2 is not a general instruction to identify a gas, discard the parent-material row and substitute an unrelated gas row. It also does not direct every water-reactive substance to Table 3. Check the exact entry and its conditions. Water contact, a material already posing a toxic-inhalation hazard, and the appropriate fire instructions are distinct considerations.

Table 3 needs container and wind conditions

Table 3 provides additional large-spill guidance for six common toxic-inhalation gases: ammonia, chlorine, ethylene oxide, hydrogen chloride, hydrogen fluoride and sulfur dioxide. It differentiates transport containers and wind bands rather than giving one number for every large spill.

The NOAA display of the current chlorine entry shows why those inputs matter. In a classroom case explicitly classified as a large chlorine spill from a rail tank car, without fire, using Table 3's published rail-car quantity assumption of 80,000 kg, its isolation entry is 3,000 feet. With daytime moderate wind, the downwind entry is 3.9 miles; the corresponding nighttime moderate-wind entry is 5.6 miles. Moderate wind is the 6-12 mph band, including its endpoints; low is below 6 and high above 12. Other container rows have different values. These are reference-reading examples, not a field perimeter decision for an unspecified leak.

Fire and residual toxic release

The green introduction and NOAA explanation distinguish fire/explosion isolation from residual toxic protection. When fire is involved, consult the applicable orange-guide fire provision for initial isolation, then retain the relevant green downwind protection for residual material release. Do not merely take the larger of two numbers and apply it as one circle.

Work exercises by naming the source row and conditions aloud, checking direction and units, and describing the notification needed. Keep the actual ERG2024 beside the question. Missing conditions are a reason to obtain information, not invent a universal answer.