Study guide

6.2 HPE Alletra Storage MP Hardware: Controller Nodes, JBOFs, Switchless & Switched Systems

HPE ATP - Storage Solutions HPE0-J81

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Orientation, Customer Requirements, HPE GreenLake & Portfolio

1.1 HPE0-J81 Exam Facts & the HPE ATP - Storage Solutions Certification Path 1.2 Assessing Storage Requirements, Workload Sizing & SLAs 1.3 HPE GreenLake Basics: Cloud Platform, Workspaces & Consumption Model 1.4 The HPE Storage Portfolio: Current Systems, Legacy Platforms & Positioning

2 Chapter 2: HPE Storage Tools, Reference Resources & Cloud Management

2.1 Assessment, Sizing & Configuration Tools: SAF, NinjaSTARS, Ninja Online & OCS 2.2 Compatibility & Reference Resources: SPOCK, QuickSpecs & HPE Support Center 2.3 Cloud Management & AIOps: Data Services Cloud Console, Data Ops Manager & HPE InfoSight

3 Chapter 3: Storage Topologies, Architectures & Implementation Models

3.1 Storage Topologies Compared: DAS, NAS, and SAN Architectures 3.2 Block, File, and Object Storage Implementations & Protocols 3.3 Converged, Hyperconverged (HCI) & Software-Defined Storage (SDS)

4 Chapter 4: Storage Fabrics, Connectivity & HPE GreenLake Services

4.1 SAN Fabric Design, Zoning & Multi-Protocol Storage Networking 4.2 Network Attached Storage Protocols, Shares & Permissions 4.3 HPE GreenLake Offerings for Storage and Data Protection

5 Chapter 5: HPE MSA Gen7 Storage: Hardware, Software & Data Protection

5.1 HPE MSA Gen7 Hardware: Models, Controllers, Drives & Expansion 5.2 HPE MSA Software: Virtual Storage, MSA-DP+, Automated Tiering & SSD Read Cache 5.3 HPE MSA Data Protection & Management: Snapshots, Volume Copy, Remote Snap & SMU v4

6 Chapter 6: HPE Alletra Storage MP B10000 & X10000

6.1 HPE Alletra Storage MP B10000 & X10000: Features and Positioning 6.2 HPE Alletra Storage MP Hardware: Controller Nodes, JBOFs, Switchless & Switched Systems 6.3 B10000 Resiliency & Data Services: All-Active Nodes, RAID 6, Data Reduction & Replication 6.4 Managing HPE Alletra Storage MP: Onboarding, Provisioning, Monitoring & Local Tools

7 Chapter 7: Data Protection Principles, Replication & Disaster Recovery

7.1 Fundamentals of Data Protection: RPO, RTO & Resiliency Architectures 7.2 Storage Snapshots, Clones & Replication Strategies 7.3 Disaster Recovery Planning, Business Continuity & Immutability

8 Chapter 8: HPE StoreOnce, Tape, GreenLake Backup and Recovery & Zerto

8.1 HPE StoreOnce Systems, Catalyst & Cloud Bank Storage 8.2 HPE Tape Solutions: LTO Technology, MSL Libraries & the Offline Air Gap 8.3 HPE GreenLake for Backup and Recovery: Architecture, Policies & Ransomware Protection 8.4 HPE Zerto Software: Continuous Data Protection, Disaster Recovery & Cyber Resilience

6.2 HPE Alletra Storage MP Hardware: Controller Nodes, JBOFs, Switchless & Switched Systems

Key Takeaways Explain This Topic AI

The Alletra Storage MP building block is a 2U chassis that holds either two controller nodes or 24 NVMe SSDs; controllers and JBOF shelves connect over 100 GbE.

B10000 switchless systems (B10120, B10130, B10140) put 2 nodes and 24 drive bays in one 2U chassis; a 4-node B10140 (4N) uses two chassis.

B10000 switched systems (B10230, B10240) use a pair of dedicated 100GbE switches, 2 to 6 controller nodes and up to 16 JBOFs, for about 5.9 PB raw.

B10000 controller nodes have no built-in host ports; each needs at least one host adapter for FC/NVMe-FC or Ethernet iSCSI/NVMe-TCP.

The X10000 scales from 3 to 16 controller nodes (64-core, 512 GB each) and 1 to 16 fully populated 24-drive JBOFs, about 23.6 PB raw.

Last updated: October 2026

HPE Alletra Storage MP Hardware

Quick Answer: Alletra Storage MP is built from 2U chassis that hold either two controller nodes or 24 NVMe SSDs (a JBOF). In a switchless B10000 the controllers and up to 24 drives share one chassis and JBOFs connect directly. In a switched B10000, two dedicated 100GbE switches connect 2 to 6 controller nodes to up to 16 JBOFs , so performance and capacity scale independently. The X10000 uses the same building blocks with 3 to 16 nodes .

Why disaggregation matters

In a traditional dual-controller array, controllers and drives are bought together. If you need more performance you buy a bigger array; if you need more capacity you may also buy controller power you do not need. In Alletra Storage MP the compute (controller nodes) and the capacity (NVMe JBOFs) are separate units on a shared network. In a switched configuration every controller node can reach every JBOF, so adding either one rebalances the system without forklift upgrades.

B10000 controller node models

  • Model Configuration Nodes Cores per node Cache memory per node Drive shelves
  • B10120 Switchless 2 8 256 GB Base chassis only
  • B10130 Switchless 2 16 256 GB Base plus up to 2 JBOFs
  • B10140 Switchless 2 32 512 GB Base plus up to 2 JBOFs

B10140 (4N) Switchless, two 2U chassis 4 32 512 GB 2 base chassis plus 1 JBOF (2 JBOFs, up to 96 drives, with ArcusOS 10.6.0)

  • B10230 Switched 2 to 6 16 256 GB Up to 16 JBOFs
  • B10240 Switched 2 to 6 32 512 GB Up to 16 JBOFs

Each node has one CPU (HPE uses AMD EPYC embedded processors) and four slots. All nodes in a system must be the same type. ArcusOS 10.6.0 added five- and six-node switched systems and a non-disruptive conversion from switchless to switched , so a customer can start small and grow.

Capacity

  • Configuration Maximum raw capacity Maximum effective capacity
  • Per shelf (24 drives) 737.2 TB 1,993.5 TB
  • B10130 or B10140 switchless system 2,211.8 TB 6,165.6 TB
  • B10230 or B10240 switched system 5.9 PB 16.6 PB

HPE calculates effective capacity with a 4:1 data compaction ratio (thin provisioning, deduplication, compression and copy technologies) in RAID 6 (10+2) , with 9% free-space headroom. Actual savings depend on the workload.

Chassis, slots and adapters

Switchless chassis: two controller nodes plus 24 SFF NVMe drive bays .

Switched chassis: two controller nodes and no drives ; all SSDs live in JBOFs.

Slots: each node has four OCP slots. Slot 2 (and optionally slot 1) holds the 100GbE back-end adapter, and slots 3 and 4 (and slot 1 when it is not used for the back end) hold host adapters. The exact slot rules depend on the model and ArcusOS release, so check the QuickSpecs.

No built-in host ports: every node needs at least one host adapter.

  • Host adapter type Protocols
  • 32/64Gb Fibre Channel FC and NVMe/FC; current systems support up to 12 FC ports per node
  • 10/25GbE Ethernet iSCSI and NVMe/TCP
  • 100GbE Ethernet iSCSI and NVMe/TCP
  • 10/25GbE replication adapter Optional Remote Copy over IP (RCIP)

For unified file, the Ethernet adapter must be in slot 4, with ports 1 and 2 dedicated to file.

JBOF expansion shelves

2U, 24 NVMe SFF bays , two shelf nodes with 8-core CPUs and 64 GB of memory that is not used as cache .

Each shelf node connects with a 100GbE OCP adapter.

Drives are added from 8 to 24 per enclosure in two-drive increments , and JBOFs are added one at a time.

Switchless versus switched B10000

  • Attribute Switchless (B10100 family) Switched (B10200 family)
  • Back-end network Direct 100GbE cables between nodes and JBOFs Two dedicated 32-port 100GbE switches
  • Drives in the controller chassis Yes, up to 24 No
  • Controller nodes 2, or 4 with the B10140 (4N) 2 to 6
  • JBOFs Up to 2 (on the 4-node model, 1, or 2 with ArcusOS 10.6.0) Up to 16
  • Best for Smaller systems, lower cost Large scale and independent growth

The switches are dedicated to back-end traffic between controller nodes and JBOF shelf nodes. HPE states they cannot be used to connect hosts or any other systems; hosts connect through the host adapters to the customer's own SAN or Ethernet network.

Drive rules

  • Rule (B10000 QuickSpecs) Value
  • Drive interface NVMe
  • NAND types TLC or QLC; no mixing in one system
  • Minimum 8 drives per chassis or system
  • Increments 2 drives
  • Capacities All drives in a system must be the same capacity and type
  • Encrypted options Self-encrypting and FIPS-validated SSDs; encryption needs a license
  • Protection RAID 6 only

QLC SSDs give lower cost per TB and higher density for read-heavy workloads; TLC SSDs suit write-intensive work.

X10000 hardware

  • Component X10000 value (QuickSpecs)
  • Controller chassis 2U, one or two controller nodes; 2 to 8 chassis
  • Controller nodes 3 to 16; one 64-core CPU and 512 GB RAM each

Back-end Two 2-port 100GbE adapters per node; a pair of internal fabric switches (100 GbE, with a 400 GbE bundle available)

  • Front-end 100GbE or 10/25GbE host ports (no mixing within a cluster)
  • JBOFs 1 to 16; 24 NVMe drives each, fully populated
  • Drives TLC 3.84 to 30.72 TB, or QLC 15.36 to 61.44 TB; no TLC and QLC mixing in a cluster
  • Raw capacity About 23.6 PB per cluster (384 drives)
  • Effective capacity Calculated at 2:1 compaction with triple-parity (20+3+1) protection

Optional nodes Data intelligence nodes (ProLiant servers with NVIDIA GPUs) and data protection accelerator nodes

The smallest X10000 has three controller nodes, so it needs two controller chassis.

Worked sizing example

A customer starts with a B10140 switchless system with 12 x 7.68 TB TLC SSDs (92 TB raw). Two years later it needs more capacity: it adds drives in pairs up to 24 in the base chassis, then adds a JBOF. When it later needs more controller performance and more than two JBOFs, ArcusOS 10.6.0 allows a non-disruptive conversion to a switched configuration.

Common exam traps

Hosts on the back-end switches: not allowed; they are internal only.

Drives in a switched controller chassis: none; use JBOFs.

Mixing TLC and QLC or capacities: not supported in a B10000 system.

Built-in host ports: there are none; order host adapters.

Loading diagram... Switched HPE Alletra Storage MP B10000