Study guide
4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings
Key Takeaways Explain This Topic AI
Curb ramp runs and blended transitions are 48 inches minimum wide, excluding flared sides (A117.1-2017 406.5.1).
Perpendicular curb ramps need a 48 x 48 inch top landing (48 x 60 where constrained at the back of sidewalk); parallel curb ramps need a 48 x 48 inch bottom landing (48 x 60 where constrained on two or more sides).
Curb ramp running slope is 1:20 minimum to 1:12 maximum, but the run need not exceed 15 feet; blended transitions are 1:20 maximum.
Cross slope is 1:48 maximum, counter slope at the gutter is 1:20 maximum, and flared sides are 10 percent maximum where pedestrians cross the ramp.
Detectable warnings are required at curb ramps and blended transitions at pedestrian street crossings, refuge islands, at-grade rail crossings and unprotected transit platform edges.
Last updated: October 2026
4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings
Curb ramps are part of the Walking Surfaces and Ramps subtopic. ICC A117.1-2017 replaced the older curb ramp rules with a structure based on public right-of-way practice. If you learned curb ramps from the 2009 edition or the ADA Standards (36-inch width, 36-inch top landing, 1:10 flares), relearn them here.
Definitions
Curb ramp : A short ramp cutting through a curb or built up to it.
Blended transition : A raised pedestrian street crossing, depressed corner or similar connection between the pedestrian access route at sidewalk level and the street crossing, with a grade of 1:20 or less .
Counter slope : Any slope opposing the running slope of a curb ramp, typically the gutter.
Grade break : The line where two surface planes with different grades meet.
Perpendicular Curb Ramps (406.2)
- Element Requirement
- Landing (406.2.1) 48 x 48 in. minimum at the top ; may overlap pedestrian routes and clear spaces
Constrained landing Where constrained at the back of sidewalk, 48 x 60 in. , with the 60 in. in the direction of the curb ramp run
Landing slope 1:48 maximum in all directions
Running slope (406.2.2) Cuts through or is built up to the curb at right angles (or meets the gutter grade break at right angles on a curved curb); 1:20 minimum and 1:12 maximum
Run length Not required to exceed 15 ft
Flared sides (406.2.3) Where a pedestrian circulation path crosses the curb ramp, flared sides are required, sloped 10 percent maximum
The 15-foot cap matters on steep streets: a curb ramp descending along a street with a steep grade may never reach 1:12 relative to level, so the code stops requiring additional length after 15 feet.
Parallel Curb Ramps (406.3)
- Element Requirement
- Landing (406.3.1) 48 x 48 in. minimum at the bottom ; may overlap pedestrian routes
Constrained landing Where constrained on two or more sides, 48 x 60 in. , with the 60 in. in the direction of the pedestrian street crossing
Landing slope 1:48 maximum in all directions
Running slope (406.3.2) In line with the direction of sidewalk travel; 1:20 minimum and 1:12 maximum; run not required to exceed 15 ft
Parallel ramps suit narrow sidewalks: the sidewalk itself ramps down to a landing at street level.
Blended Transitions (406.4)
Running slope 1:20 maximum . Because a blended transition is not steeper than 1:20, it is not a ramp and does not need handrails, but it does need detectable warnings at street crossings.
Common Requirements (406.5)
- Section Requirement
- 406.5.1 Width Curb ramp runs (excluding flared sides) and blended transitions 48 in. minimum
406.5.2 Grade breaks Perpendicular to the direction of the ramp run at the top and bottom; not permitted on the surface of ramp runs and landings; surfaces meeting at grade breaks are flush
406.5.3 Cross slope 1:48 maximum; at crossings without yield or stop control and at mid-block crossings, may equal the street grade
406.5.4 Counter slope Gutter or street at the foot of the ramp, blended transition or landing 1:20 maximum
406.5.5 Clear space Beyond the bottom grade break, 48 x 48 in. within the width of the crossing and wholly outside the parallel vehicle travel lane
406.5.6 Marking If adjacent curbs are painted, the paint extends along the flared portion
406.5.7 Location Curb ramps and flares may not project into vehicular traffic lanes, parking spaces or parking access aisles; at marked crossings, ramps are wholly within the markings (excluding flares)
- 406.5.8 Obstructions Located or protected to prevent obstruction by parked vehicles
- 406.5.9 Handrails Not required on curb ramps
- Detectable Warnings (406.6 and 705)
Section 406.6.1 says where detectable warnings are provided they comply with Section 705. Section 406.6.2 then requires them at:
Curb ramps and blended transitions at pedestrian street crossings ;
Pedestrian refuge islands (except cut-through islands at street level less than 6 ft long in the direction of travel);
Pedestrian at-grade rail crossings not within a street or highway;
Boarding platforms at bus and rail transit stops where the platform edges are not protected by screens or guards;
Boarding and alighting areas at sidewalk or street-level rail transit stops where the side facing the rail vehicles is not protected.
A117.1 Section 705 sets the dome geometry (base diameter, top diameter, height and spacing), visual contrast and the placement of the warning surface on each configuration; see Section 8.3 of this guide. IBC 1110.13 (2024; 1110.11 in 2021) scopes detectable warnings on passenger transit platform edges bordering a drop-off without screens or guards, and exempts bus stops.
Worked Example
A new campus street crossing uses perpendicular curb ramps. The sidewalk is 7 feet wide with a building face at the back.
Ramp run: 48 inches wide minimum, running slope between 1:20 and 1:12. A 6-inch curb at 1:12 needs 72 inches of run.
Top landing: 48 x 48 inches minimum, but because the landing is constrained by the building at the back of the sidewalk, 48 x 60 inches with 60 inches in the direction of the ramp.
72 inches of ramp plus 60 inches of landing is 132 inches, more than the 84-inch sidewalk. A parallel curb ramp or a blended transition is the practical solution.
Detectable warnings are required because this is a pedestrian street crossing.
Exam Traps
- Trap 2017 rule
- 36-inch curb ramp width 48 inches
- 36-inch top landing 48 x 48 inches (48 x 60 when constrained)
Flares 1:10 measured parallel to the curb, 1:12 with short landings Flares 10 percent maximum where pedestrians cross the ramp
- Handrails on curb ramps Not required
- Detectable warnings optional Required at street crossings and the other 406.6.2 locations