Study guide
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width
Key Takeaways Explain This Topic AI
IBC 1104.1 requires an accessible route from public transportation stops, accessible parking, accessible passenger loading zones and public streets or sidewalks to the accessible entrance served.
IBC 1104.4 Exception 1 releases stories with an aggregate area of 3,000 square feet or less, but not for M with five or more tenants, health care offices, transportation facilities, government buildings or structures with four or more dwelling units.
Accessible route walking surfaces have a running slope not steeper than 1:20 and a cross slope not steeper than 1:48; steeper running slopes are ramps.
A117.1-2017 requires 36-inch interior and 48-inch exterior accessible routes; 32-inch point reductions up to 24 inches long must be separated by 52-inch segments in new buildings (48 inches existing).
Routes narrower than 60 inches need passing spaces at 200-foot maximum intervals; new 180-degree turns around objects less than 52 inches wide use 36/60/36, 42/48/42 or 43/43/43 widths.
Last updated: October 2026
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width
Accessible Routes is the largest domain on the ICC 21 exam (27%). This section covers the scoping that decides where routes are required (IBC 1104) and the technical rules every route segment must meet (A117.1 Sections 402 and 403). Doors, ramps, curb ramps, elevators and lifts follow in later sections.
IBC 1104: Where Accessible Routes Are Required
Section Requirement
1104.1 Site arrival points At least one accessible route within the site from public transportation stops, accessible parking, accessible passenger loading zones, and public streets or sidewalks to the accessible building entrance served. Exception: other than in buildings containing or serving Type B units, no route is needed if the only access between them is a vehicular way not providing for pedestrian access.
1104.2 Within a site At least one accessible route connects accessible buildings, facilities, elements and spaces on the same site (same vehicular-way exception; recreational facilities only as required by 1111).
1104.3 Connected spaces At least one accessible route to each portion of a building required to be accessible, to accessible entrances connecting accessible pedestrian walkways, and to the public way. Exceptions: stories exempted by 1104.4; assembly levels with fixed seating that have no wheelchair spaces; elevated courtroom employee work stations under 1109.4.1.4; recreational facilities as limited by 1111.
1104.3.1 Common use circulation paths in employee work areas (see Section 1.1).
1104.3.2 Press boxes Must be on an accessible route, except press boxes in bleachers with a single point of entry, or free-standing press boxes more than 12 ft above grade, where the aggregate press box area per playing field is 500 sq ft or less.
1104.4 Multistory At least one accessible route connects each accessible story, mezzanine and occupied roof.
1104.5 Location Routes coincide with or are in the same area as general circulation paths; interior circulation needs an interior route; where only one route exists, it may not pass through kitchens, storage rooms, restrooms, closets or similar spaces (a kitchen or storage room in an Accessible, Type A or Type B unit is allowed).
1104.6 Security barriers Bollards and checkpoints may not obstruct accessible routes or accessible means of egress; a route beside a metal detector is allowed if users keep visual contact with their belongings.
The Multistory Exceptions (1104.4)
Stories, mezzanines and occupied roofs with an aggregate area of not more than 3,000 sq ft located above and below accessible levels. This exception does not apply to: multiple-tenant Group M facilities with five or more tenant spaces where at least one is above or below the accessible level; stories containing offices of health care providers (Group B or I); passenger transportation facilities and airports ; government buildings ; and structures with four or more dwelling units .
Stories, mezzanines or occupied roofs that contain no accessible elements or spaces required by Sections 1108 or 1109.
The cab of an air traffic control tower and the floor immediately below it.
A two-story building where one story or mezzanine has an occupant load of five or fewer and contains no public use space.
A117.1 Section 402: Route Components
An accessible route consists of one or more of: walking surfaces with a running slope not steeper than 1:20 , doors and doorways, gates, ramps, curb ramps (excluding flared sides), blended transitions, elevators and platform lifts. Revolving doors, revolving gates and turnstiles are not part of an accessible route (402.3); an accessible door or gate must be provided beside them.
A117.1 Section 403: Walking Surfaces
- Rule Section Requirement
- Surface 403.2 Comply with 302 (stable, firm, slip resistant)
- Slope 403.3 Running slope not steeper than 1:20 ; cross slope not steeper than 1:48
- Changes in level 403.4 Comply with 303 (1/4 in. vertical, 1/2 in. beveled)
Handrails 403.6 Where handrails are required at the side of a corridor, they comply with Sections 505.4 through 505.9
A walking surface steeper than 1:20 is a ramp (A117.1 definition) and must comply with Section 405. A path that rises 15 inches over 24 feet (288 inches) has a slope of 15/288 = 1:19.2, which is steeper than 1:20, so it is a ramp needing landings and, because the rise exceeds 6 inches, handrails.
Clear Width (403.5)
- Condition Requirement (A117.1-2017)
- Interior accessible route 36 in. minimum
- Exterior accessible route 48 in. minimum
- Exterior route within seating areas 36 in. minimum
- Exterior ramp Clear width per 405.5 (36 in.)
Point reduction, new buildings 32 in. minimum for 24 in. maximum length; reduced segments separated by segments 52 in. long and 36 in. wide
Point reduction, existing buildings 32 in. for 24 in. maximum; separated by segments 48 in. long and 36 in. wide
180-Degree Turns (403.5.2)
- Condition Requirement
- New, object 52 in. or wider Normal widths of 403.5.1 apply through the turn
New, object less than 52 in. wide One set of approach/during/leaving widths: 36/60/36 , 42/48/42 , or 43/43/43 in.
Existing, object less than 48 in. wide 42/48/42 in.; not required where the width during the turn is 60 in.
90-Degree Turns (403.5.3)
New buildings use one of four sets: both legs 40 in. wide maintained for 28 in. from the inner corner; both legs 36 in. where the interior corners are chamfered 8 in. along both walls; one leg 42 in. and the other 38 in.; or one leg 44 in. and the other 36 in. Turns at doors complying with 404.2.3 and at elevators or lifts complying with 407 to 410 are exempt. Existing buildings require 36 in. legs.
Passing Spaces (403.5.4)
Where a route is less than 60 in. wide, passing spaces are required at 200 ft maximum intervals. A passing space is either a 60 x 60 in. space or an intersection of two walking surfaces forming a T-shaped turning space whose base and arms extend 52 in. (new, using a 304.3.2.1 T) or 48 in. (existing) beyond the intersection.
Worked Example
A new office corridor is 40 inches wide and 260 feet long, with one structural column narrowing it to 33 inches for 18 inches of length.
The 40-inch interior width exceeds 36 inches.
The column creates a point reduction: 33 inches is at least 32 inches and 18 inches is no more than 24 inches, so it complies. A second reduction would need at least 52 inches of 36-inch-wide corridor between them.
At 260 feet long and less than 60 inches wide, the corridor needs passing spaces at intervals of 200 feet maximum, for example a 60 x 60 alcove or a qualifying T intersection.
Exam Traps
Exterior accessible routes are 48 inches wide in A117.1-2017, not 36 (IEBC 306.7.6 allows 36 inches for exterior routes in alterations).
New-building point reductions use 52-inch separations.
Passing spaces are 403.5.4 in the 2017 edition.
The 3,000 sq ft multistory exception is an aggregate area test, and government buildings cannot use it.