Study guide

3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances

Key Takeaways Explain This Topic AI

Doorways need a 32-inch clear opening measured between the face of the door and the stop with the door open 90 degrees; openings more than 24 inches deep need 36 inches.

No projections are allowed into the clear opening below 34 inches; between 34 and 80 inches projections are limited to 4 inches, with door closers and stops allowed at 78 inches.

Front approach maneuvering clearance is 60 inches deep plus 18 inches beyond the latch on the pull side and 52 inches deep (48 existing) on the push side.

Add 6 inches of depth at a hinge-side push approach when the door has both a closer and a latch, and at a latch-side approach when the door has a closer.

A forward-approach clearance is required where an obstruction within 18 inches of the latch side projects more than 8 inches beyond the face of the door (404.2.3.5).

Last updated: October 2026

3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances

Windows, Doors, and Doorways carries 5% of the ICC 21 outline. The 2017 edition of A117.1 changed several maneuvering numbers, so read the table in your edition carefully rather than relying on ADA or 2009 memory.

Scope (404.1)

Doors, doorways and gates that are part of an accessible route comply with Section 404. Doors operated only by security personnel are exempt from the maneuvering clearance, hardware, closing speed and opening force provisions. IBC 1010.1.1 independently requires egress doors to provide 32 in. clear width, with its own exceptions (for example, doors not required to be accessible in Group R-2 and R-3 dwelling units).

Clear Width (404.2.2)

Doorways: 32 in. minimum clear opening.

Swinging doors: measured between the face of the door and the stop with the door open 90 degrees .

Openings more than 24 in. deep at doorways without doors : 36 in. minimum.

No projections into the clear width below 34 in. above the floor.

Projections between 34 and 80 in. : 4 in. maximum.

Exceptions: door closers and door stops may be 78 in. minimum above the floor; in alterations , a 5/8-in. projection of the latch-side stop into the clear width is allowed.

Double-leaf doors (404.2.1): at least one active leaf must meet the clear width and maneuvering clearances.

A nominal 36-inch door typically yields about 33 to 34 inches clear once the door thickness and stop are deducted; a nominal 34-inch door is often too narrow.

Maneuvering Clearances (404.2.3)

Maneuvering clearances include the full clear opening width plus the required latch-side or hinge-side clearance, and the floor within them must slope no more than 1:48 (404.2.3.1).

Table 404.2.3.2: Manual Swinging Doors

Approach Door side Perpendicular to doorway Parallel to doorway (beyond latch unless noted)

From front Pull 60 in. 18 in.

From front Push 52 in. (48 in. in existing buildings) 0 in.

From hinge side Pull 60 in. 36 in.

From hinge side Pull 54 in. 42 in.

From hinge side Push 42 in. (+6 in. if closer and latch) 22 in. beyond hinge side

From latch side Pull 48 in. (+6 in. if closer ) 24 in.

From latch side Push 42 in. (+6 in. if closer ) 24 in.

Note what the 2017 table does not contain: there is no 12-inch latch-side clearance on the front push side. That figure comes from the ADA Standards and older editions. In A117.1-2017 the front push side needs depth (52 in. new, 48 in. existing) but 0 in. beyond the latch.

Table 404.2.3.3: Sliding and Folding Doors

Approach Perpendicular Parallel

From front 52 in. (48 in. existing) 0 in.

From nonlatch side 42 in. 22 in. beyond pocket or hinge side

From latch side 42 in. 24 in.

Table 404.2.3.4: Doorways Without Doors (less than 36 in. wide)

  • Approach Perpendicular
  • From front 52 in. (48 in. existing)

From side 42 in.

Recessed Doors (404.2.3.5)

Where any obstruction within 18 in. of the latch side of a doorway projects more than 8 in. beyond the face of the door, measured perpendicular to the face of the door, maneuvering clearances for a forward approach are required. A door set deep in a wall with a return on the latch side therefore needs front-approach clearances even if users arrive from the side.

Thresholds and Doors in Series

Thresholds (404.2.4) : 1/2 in. maximum, complying with 302 and 303; existing or altered thresholds up to 3/4 in. high with a 1:2 bevel on each side for the height above 1/4 in.

Two doors in series (404.2.5) : 48 in. minimum between hinged or pivoted doors plus the width of any door swinging into the space, and the space must provide a turning space . Two 36-inch doors both swinging into the vestibule need 48 + 36 + 36 = 120 in.

Worked Examples

Office door, front approach, pull side, new building : 60 inches perpendicular and 18 inches beyond the latch. A wall return 12 inches from the latch jamb fails.

Same door, push side : 52 inches perpendicular in a new building. A corridor 48 inches wide in front of the push side fails in new construction but complies in an existing building.

Latch-side approach, push side, door with closer and latch : 42 + 6 = 48 inches perpendicular, 24 inches beyond the latch. The "+6" here is triggered by the closer ; whether a latch exists does not matter for latch-side approaches.

Hinge-side approach, push side, door with closer but no latch (a push-pull door): 42 inches perpendicular, 22 inches beyond the hinge side. The +6 applies only when both a closer and a latch are present.

Exam Traps

  • Trap Correct rule
  • Measuring frame to frame Measure from the face of the open door to the stop
  • 48-inch push side in new construction 52 inches new, 48 existing
  • 12-inch latch clearance on the front push side Not in A117.1-2017
  • Latch-side +6 "if closer and latch" Latch side adds 6 in. if a closer is provided
  • Sliding door slide-side clearance of 54 in. 22 in. beyond the pocket side