Study guide

1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy

Key Takeaways Explain This Topic AI

IEBC 306.7 requires altered facilities to comply with IBC Chapter 11 and A117.1 unless technically infeasible, and then to provide access to the maximum extent technically feasible.

An alteration may not decrease accessibility below new-construction requirements at the time of the alteration (2021 IEBC 306.3.1; 2024 IEBC 306.2.1).

When an alteration affects or contains a primary function area, the route to it, including the toilet facilities and drinking fountains serving it, must be accessible, capped at 20 percent of the alteration cost by Exception 1.

Additions are new construction; an addition that affects or contains a primary function area also triggers the 306.7.1 route requirement.

Accessible means of egress are not required to be added in existing facilities, and Type B units are not required where the work area is 50 percent or less of the building.

Last updated: October 2026

1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy

Accessibility in Existing Buildings is the largest subtopic in the General Administrative domain (4% of the exam). The governing provisions are in IEBC Section 306 , which applies under every IEBC compliance method. The 2021 and 2024 IEBC both use Section 306, but the 2024 edition renumbered several subsections; both numbers are given below.

The Framework

Topic 2021 IEBC 2024 IEBC Rule

Scope 306.1 306.1 Applies to maintenance and repair, change of occupancy, additions and alterations, including historic buildings

Design 306.2 306.3 Comply with the IEBC and the alteration and existing building provisions of A117.1

Maintenance 306.3 306.2 (General) Accessible facilities are maintained accessible; required accessible means of egress are maintained during construction

Prohibited reduction 306.3.1 306.2.1 An alteration may not decrease accessibility below new-construction requirements at the time of the alteration

Extent 306.4 306.4 An alteration never requires more accessibility than new construction would

Change of occupancy 306.5 306.5 Comply with 306.7; Type B units not required where the work area is 50% or less

  • Additions 306.6 306.6 New-construction rules apply; primary function additions trigger 306.7.1
  • Alterations 306.7 306.7 Comply with IBC Chapter 11 and A117.1 unless technically infeasible
  • Prohibited Reduction

The prohibited-reduction rule compares the altered condition with new-construction requirements at the time of the alteration . Replacing a compliant lever handle with a knob, removing grab bars, or narrowing an accessible door below 32 in. clear is prohibited. The same section limits the count: the number of accessible elements need not exceed what new construction would require.

Technically Infeasible

Section 306.7 requires altered elements to comply "unless technically infeasible. Where compliance with this section is technically infeasible, the alteration shall provide access to the maximum extent technically feasible ." Cost is not part of the technically infeasible definition. Cost enters the IEBC only through the 20% exception discussed below.

Primary Function Areas (306.7.1)

Where an alteration affects the accessibility to, or contains an area of primary function, the route to the primary function area shall be accessible. The accessible route to the primary function area shall include toilet facilities and drinking fountains serving the area of primary function.

A primary function is a major activity for which the facility is intended: a bank customer lobby, a cafeteria dining area, conference rooms, offices and other work areas. The definition expressly excludes mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors and restrooms.

The Five Exceptions

Exception The route requirement does not apply to

1 Costs above 20 percent of the cost of the alterations affecting the primary function area (2024 wording: the costs of the accessible route, toilet facilities and drinking fountains)

2 Alterations limited solely to windows, hardware, operating controls, electrical outlets and signs

3 Alterations limited solely to mechanical systems, electrical systems, fire protection systems and abatement of hazardous materials

  • 4 Alterations undertaken primarily to increase the accessibility of the facility
  • 5 Altered areas limited to Type B dwelling and sleeping units
  • Worked Example

An owner remodels a retail sales floor (a primary function area) for $180,000. The route from the entrance to the sales floor has a non-compliant door and the toilet room serving the floor lacks grab bars and an accessible lavatory.

The sales floor itself must comply fully, to the maximum extent technically feasible. The 20% limit never reduces the work on the altered area itself.

Route, toilet room and drinking fountain upgrades are required, but Exception 1 says their cost is not required to exceed 0.20 x $180,000 = $36,000 .

If full upgrades cost $30,000, all must be done. If they cost $52,000, at least $36,000 must be spent and the jurisdiction will expect the spending to improve the route first.

Note

The federal ADA regulation for public accommodations (28 CFR 36.403) contains a separate disproportionality rule with a listed priority order (entrance, route, toilet rooms, telephones, drinking fountains) and an aggregation rule for a series of small alterations. Those details are federal law, not IEBC text. On the ICC 21 exam, answer from IEBC 306.7.1 and its five exceptions.

Additions (306.6)

Provisions for new construction apply to additions. In addition, "an addition that affects the accessibility to, or contains an area of, a primary function shall comply with the requirements in Section 306.7.1." The addition is built to new-construction rules with no cost cap, while the route through the existing building that serves a new primary function area is subject to 306.7.1 and its 20% exception. The 2024 IEBC added 306.6.1, requiring at least one accessible means of egress from an addition where IBC 1009.1 requires it, with relief in 306.6.1.1 for additions built only to house an elevator.

Change of Occupancy (306.5)

A building that undergoes a change of group or occupancy complies with Section 306.7, so the altered-facility rules, including the primary function route requirement, apply to the work. The exception releases Type B units in a change of occupancy combined with alterations where the work area is 50 percent or less of the aggregate building area. Local amendments sometimes add a minimum feature list for a complete change of occupancy; answer from the model IEBC text unless the question states an amendment.

Specific Alteration Rules

  • Topic 2021 2024 Rule
  • Accessible means of egress 306.7.2 306.7.2 Not required to be added in existing facilities
  • Type A units 306.7.3 306.7.3 Individually owned Type A units in R-2 may meet Type B criteria
  • Type B units 306.7.4 306.7.4 Not required where the work area is 50% or less of the building

Entrances 306.7.5 306.7.5 An altered inaccessible entrance need not become accessible if the facility already has an accessible entrance, unless 306.7.1 requires it; IBC 1112 signs required

  • Exterior routes 306.7.6 306.7.6 Exterior accessible routes, including curb ramps, 36 in. minimum width
  • Elevators 306.7.7 306.7.7 Altered elements comply with ASME A17.1, including elevators on the same hall call
  • LULA elevators Not separately listed 306.7.8 Permitted as part of an accessible route
  • Platform lifts 306.7.8 306.7.9 Lifts installed per ASME A18.1 permitted as part of an accessible route

New stairway or escalator 306.7.9 306.7.10 Where none existed and major structural modification is needed, an accessible route between the levels is required

Toilet rooms 306.7.11 306.7.12 If altering existing rooms is technically infeasible, one accessible single-user or family/assisted-use room on the same floor and in the same area, with directional signs

Bathing rooms 306.7.12 306.7.13 Same approach for bathing rooms

Dressing and locker rooms 306.7.14 306.7.16 One accessible room on the same level where technically infeasible at the same location

Amusement rides 306.7.15 306.7.17 Rides altered beyond the manufacturer's design comply as new

Section 306.7.10 (2021) and 306.7.11 (2024) set unit counts: Accessible-unit requirements apply only to the units being altered or added; Type A requirements apply where more than 20 Group R-2 units are altered or added; Type B requirements apply where four or more units are added, or where units are altered and the work area exceeds 50% of the building.