1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
1.2 General Administration: Definitions, Conventions, and Code Editions
Key Takeaways Explain This Topic AI
The ICC 21 exam is offered on 2021 and 2024 code editions; both use ICC A117.1-2017 and the matching IBC and IEBC.
ICC writes exam questions from the first printing of each reference book, and only the approved references can be used to appeal a question.
A117.1-2017 applies larger 'new buildings and facilities' dimensions and keeps older dimensions for existing buildings, defined as those erected or permitted before the standard was adopted.
A117.1 Section 105.2 permits rounding down values less than one-half when ratios or percentages are calculated; 105.3 applies industry tolerances except where a requirement is a stated range.
A117.1 Section 104 allows alternative designs that provide equivalent or greater accessibility when approved by the administrative authority.
Last updated: October 2026
1.2 General Administration: Definitions, Conventions, and Code Editions
The General Administration subtopic (1% of the ICC 21 outline) asks you to determine compliance "while using proper terms and definitions within code provisions." Many wrong answers on this exam come from misreading a defined term rather than from forgetting a number.
Which Books, Which Editions
ICC's exam catalog lists exam 21 in two editions, and both use the same standard:
- Exam edition Building code Existing building code Technical standard
- 2021 2021 IBC 2021 IEBC ICC A117.1-2017
- 2024 2024 IBC 2024 IEBC ICC A117.1-2017
The exam has 80 four-option multiple-choice questions, a 2.5-hour limit, and is open book. ICC states that exam questions are developed from the first printing of each code book and that only the approved reference list may be used as the basis for appealing a question. Bring the edition that matches your registration. Section numbers in this guide follow the 2021 and 2024 IBC, which share the same Chapter 11 section numbers (1101 to 1112); where subsection numbers differ, both are given.
- How the Documents Fit Together
- IBC Chapter 11 scopes accessibility. Section 1102.1 requires compliance with "this code and ICC A117.1."
IBC Chapter 10 contains the accessible means of egress provisions (Section 1009) and other "mainstreamed" items such as ramps (1012) and handrails (1014).
IBC Chapter 9 contains visible alarm scoping (907.5.2.3).
IEBC Section 306 scopes accessibility for repairs, alterations, additions and changes of occupancy.
ICC A117.1 contains technical criteria. Section 102.2 says sites, facilities, buildings and elements required to be accessible "by the scoping provisions adopted by the administrative authority" comply with Chapters 3 to 10, and dwelling and sleeping units comply with Chapter 11. A117.1 does not decide how many elements are required; the IBC does.
A117.1 Chapter 1 Conventions
Section Rule Exam use
103 Criteria are based on adult body sizes and, where noted, children Children's provisions are optional alternatives where specifically stated
104 Alternative designs, products or technologies are allowed where they give equivalent or greater accessibility and the administrative authority approves A designer may not self-certify equivalence
105.1 Specific criteria govern over general criteria Toilet room door rules govern over general door rules
105.2 Where ratios or percentages are calculated, values less than one-half may be rounded down 2.4 required spaces may round to 2; 2.5 must round up to 3
105.3 Dimensions are subject to conventional industry tolerances, except where the requirement is a range with stated minimum and maximum end points A grab bar height of 33 to 36 inches has no tolerance
- 105.4 Figures are informational only unless stated otherwise The text governs when a figure seems to conflict
- 105.5 "Floor" means the finish floor or ground surface Measure heights from finish surfaces
- 105.6 A reference to a section includes all its subsections "Comply with 404" pulls in all of 404
106 Referenced documents (ASME A17.1, ASME A18.1, NFPA 72, BHMA A156.10/A156.19, MUTCD and others) become part of the standard to the prescribed extent Elevator and lift safety criteria live in ASME standards
New Versus Existing in A117.1-2017
The 2017 edition introduced larger dimensions labelled "new buildings and facilities" and kept the earlier dimensions for "existing buildings and facilities." Section 107.5 defines an existing building as one erected before the date the standard was adopted, or one for which a legal building permit has been issued. Typical pairs:
Element New buildings Existing buildings
Clear floor space 30 x 52 in. 30 x 48 in.
- Circular turning space 67 in. diameter 60 in. diameter
- Front approach, push side of a swinging door 52 in. deep 48 in. deep
- Passenger loading zone access aisle 67 in. wide 60 in. wide
- Point reductions in route width, separation 52 in. segments 48 in. segments
When a question does not state otherwise, a "new" building uses the new-construction column. Additions are new construction.
Definitions That Change Answers
Term Key meaning
Accessible Complies with A117.1 (A117.1 107.5); in the IBC, a site, building, facility or portion that complies with Chapter 11
- Accessible route A continuous, unobstructed path that complies with Chapter 11
- Common use Shared by two or more people but not for public use
- Public use Made available to the general public
Employee work area Used only by employees and only for work; corridors, toilet rooms, kitchenettes and break rooms are not employee work areas
Circulation path Exterior or interior way of passage, including walks, hallways, courtyards, elevators, platform lifts, ramps, stairways and landings
- Ramp A walking surface with a running slope steeper than 1:20
- Blended transition A raised crossing, depressed corner or similar connection with a grade of 1:20 or less
Dwelling unit Complete, independent living facilities including permanent provisions for living, sleeping, eating, cooking and sanitation
Sleeping unit A room in which people sleep that may include provisions for living, eating and either sanitation or kitchen facilities, but not both
Technically infeasible An alteration with little likelihood of being accomplished because of structural conditions (a load-bearing member that is an essential part of the structural frame) or other existing physical or site constraints
Primary function A major activity for which the facility is intended; mechanical rooms, boiler rooms, supply storage, employee lounges and locker rooms, janitorial closets, entrances, corridors and restrooms are not primary function areas
Wheelchair space / wheelchair space location A space for one wheelchair and its occupant / a location containing one or more wheelchair spaces plus companion seating
Administrative Authority
The building official enforces the adopted IBC and approves alternative methods and modifications under the administrative provisions of IBC Chapter 1. ADA and Fair Housing Act obligations exist separately under federal law; the IBC user note says the I-Codes are intended to meet or exceed those requirements, but a building permit does not certify federal compliance.
Exam Traps
Reading a figure as if it were mandatory when the text says something different (105.4).
Applying a tolerance to a stated range such as 17 to 19 in. seat height (105.3).
Treating a staff break room as an employee work area.
Using the 60-inch turning circle for a new building.