Study guide
10.1 Dining Surfaces and Work Surfaces
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
10.1 Dining Surfaces and Work Surfaces
Key Takeaways Explain This Topic AI
At least 5 percent of seating and standing spaces at dining and work surfaces must be accessible; the 2024 IBC extends this to movable dining surfaces, while the 2021 IBC counts fixed or built-in surfaces.
Accessible dining and work surface spaces are dispersed throughout the space and located on a level served by an accessible route.
A117.1 902 requires a forward-approach clear floor space with knee and toe clearance and a top 28 to 34 inches above the floor.
Knee and toe clearance need not extend beyond a drink surface 12 inches or less deep, and dining surfaces 15 to 24 inches high may use a parallel approach.
Children's dining and work surfaces may be 26 to 30 inches high with 24-inch knee clearance, and surfaces for children 5 and younger may use a parallel approach.
Last updated: October 2026
10.1 Dining Surfaces and Work Surfaces
The Built-in Furnishings and Equipment domain is 5% of the exam: Seating at Tables, Counters and Work Surfaces (4%) and Storage Elements (1%). The scoping is in IBC Section 1110 (and 1109.2.9 for dining areas); the technical criteria are in A117.1 Chapter 9.
Scoping
Topic 2021 IBC 2024 IBC
Seating and standing spaces at tables, counters and work surfaces 1110.12: where provided at fixed or built-in surfaces in accessible spaces, at least 5 percent , not less than one, accessible 1110.14: dining surfaces, 5 percent of seating and standing spaces at fixed, built-in and movable dining surfaces (1110.14.1); work surfaces, 5 percent at fixed or built-in surfaces (1110.14.2)
- Dispersion 1110.12.1: distributed throughout the space and on a level with an accessible route 1110.14.3: same
- Check-writing surfaces Exempt where the check-out aisle is not required to be accessible Same
Dining and drinking areas 1109.2.9: all interior and exterior floor areas accessible and on an accessible route (with exceptions); 1109.2.9.1: 5 percent of dining surfaces accessible and distributed Same structure
Visiting areas 1110.12.2 1110.15
Employee work surfaces used only by employees for work are in employee work areas and are generally not required to comply (1103.2.2), but work surfaces for public or common use, such as a library study carrel or a public counter-height writing surface, are.
Dining Area Route Exceptions (1109.2.9)
An accessible route between levels is not required where 1104.4 Exception 1 applies.
A dining mezzanine is not required to be on an accessible route if it contains less than 25 percent of the total dining area and the same services and decor are provided in the accessible area.
Tiered dining in sports facilities: routes serving at least 25 percent of the dining area, provided they serve the accessible seating and each tier has the same services.
Employee-only work areas follow 1103.2.2 and 1104.3.1.
Technical Criteria (A117.1 Section 902)
Item Section Requirement
Clear floor space 902.2 Forward approach , with knee and toe clearance per 306 (new-building clear floor space 30 x 52 in.)
Drink surfaces 902.2 Exception 1 At drink surfaces 12 in. or less deep, knee and toe clearance need not extend beyond the depth of the surface
Low dining surfaces 902.2 Exception 2 Dining surfaces 15 to 24 in. high may have a parallel-approach clear floor space
- Exposed surfaces 902.3 No sharp or abrasive surfaces under exposed portions
- Height 902.4 Top 28 to 34 in. above the floor
Children's surfaces 902.5 Forward approach with knee and toe clearance (24 in. minimum knee clearance permitted); top 26 to 30 in. ; surfaces for children 5 and younger may use a parallel approach instead
The knee clearance rules of Section 306 apply in full: 27 in. minimum under the front edge (for adult surfaces), 30 in. wide, 17 to 25 in. deep with toe clearance.
Where 902 Is Referenced
Section 902 is the work surface standard for several other provisions: diaper changing tables (603.5), kitchen work surfaces (804.3), courtroom stations (807.4), tiered seating with dining surfaces (802.1), check-writing surfaces at check-out aisles (904.4.3), and tray slides (904.5.2 uses the same 28 to 34 in. range).
Worked Examples
Restaurant (2024 IBC): 40 movable tables seat 160 people, and a fixed bar has 18 standing and seating spaces. Five percent of the 160 table seats = 8 accessible seating spaces at tables, dispersed among the dining room's areas and table types. Five percent of 18 bar spaces = 0.9, so at least 1 accessible space at the bar, or an accessible portion elsewhere in the same area that offers the same services. Under the 2021 IBC, the movable tables would be counted through 1109.2.9.1 (5 percent of dining surfaces), giving a similar outcome.
Library study carrels: 30 fixed carrels for public use need at least 2 accessible carrels (5 percent of 30 = 1.5, rounded up), each with a forward approach, knee and toe clearance and a top 28 to 34 inches high, located on an accessible route and dispersed.
Bar top at 42 inches: A 42-inch bar does not comply as an accessible dining surface. Provide a 28 to 34 inch high portion (with knee clearance) or accessible tables in the same area offering the same service.
Exam Traps
Trap Correct rule
A 42-inch bar or counter is "accessible" because it has a footrest Dining and work surfaces are 28 to 34 inches high with knee and toe clearance
- Knee clearance can stop at 12 inches under any surface Only at drink surfaces 12 inches or less deep
- Movable tables never count (2024 IBC) 1110.14.1 counts fixed, built-in and movable dining surfaces
All accessible seats can be grouped by the door Accessible spaces are dispersed throughout the space and on an accessible level
A children's table must be 28 to 34 inches high Children's surfaces may be 26 to 30 inches with 24-inch knee clearance