Study guide

10.2 Sales and Service Counters and Windows

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

10.2 Sales and Service Counters and Windows

Key Takeaways Explain This Topic AI

At least one of each type of sales or service counter and window must be accessible, and accessible counters are dispersed where counters are dispersed (IBC 1110.13.2 in 2021; 1110.16.2 in 2024).

A parallel-approach accessible counter portion is 36 inches long and 36 inches maximum high with a parallel clear floor space; a forward-approach portion is 30 inches long and 36 inches maximum high with knee and toe clearance.

The accessible portion extends the same depth as the public counter used by standing customers, and objects above it are 12 inches minimum above the surface.

Vertical barriers between staff and customers are 43 inches maximum high, although transparent security glazing may extend above.

In alterations, a 24-inch accessible portion is permitted where a full-length portion would reduce existing work stations or mailboxes, with the clear floor space centered on it.

Last updated: October 2026

  • 10.2 Sales and Service Counters and Windows
  • Scoping (IBC Service Facilities)

Topic 2021 IBC 2024 IBC Requirement

Sales and service counters and windows 1110.13.2 1110.16.2 At least one of each type of counter and window provided for sale or distribution of goods or services is accessible; where counters are dispersed, accessible counters are dispersed too

Food service lines 1110.13.3 1110.16.3 Accessible; where self-service shelves are provided, at least 50 percent , not less than one, of each type accessible

Queue and waiting lines 1110.13.4 1110.16.4 Queues serving accessible counters or check-out aisles are accessible

Controls and hardware 1110.15 1110.18 Controls, operating mechanisms and hardware intended for occupant use are accessible

"Type" is a function-based distinction: a hotel lobby with a registration counter and a concierge counter has two types and needs an accessible portion at each. A bank with ten identical teller windows needs one accessible teller station; if teller windows are on two floors, the accessible stations are dispersed.

  • Technical Criteria (A117.1 Section 904)
  • General (904.1 to 904.3)

Drive-up only counters and windows are exempt (904.1).

All portions of counters required to be accessible are adjacent to a walking surface complying with 403 (904.2).

Each counter complies with 904.3.1 (vertical barriers) and either 904.3.2 (parallel approach) or 904.3.3 (forward approach).

The accessible portion of the countertop extends the same depth as the public portion provided for standing customers (904.3). A "shelf" that is only 8 inches deep in front of a 24-inch-deep counter does not comply.

  • Item Parallel approach (904.3.2) Forward approach (904.3.3)
  • Length of accessible portion 36 in. minimum 30 in. minimum
  • Height 36 in. maximum above the floor 36 in. maximum

Clear floor space Parallel approach adjacent to the counter Forward approach with knee and toe clearance per 306 under the counter

  • Clearance above 12 in. minimum between the surface and any projecting object above 12 in. minimum
  • Short counters Where the whole counter is less than 36 in. long, the entire counter meets the height limit -

The 2017 standard as printed with Supplement 1 states the parallel-approach portion as 26 inches minimum to 36 inches maximum high; an accessible portion between 28 and 36 inches high satisfies either printing.

Vertical Barriers (904.3.1)

At service windows or counters, any vertical barrier between service personnel and customers is 43 in. maximum above the floor. Transparent security glazing may extend above 43 in.

Security Glazing (904.6)

Where counters or teller windows have security glazing separating personnel from the public, a method to facilitate voice communication is provided. Telephone handset devices, where provided, comply with the volume control requirements of 704.3.

Alterations Exception (904.3)

In alterations, where providing a full accessible counter would reduce the number of existing work stations or the number of existing mail boxes , the counter may have an accessible portion 24 in. minimum long complying with the parallel-approach criteria, with the required clear floor space centered on that portion.

Related Counters

  • Counter type Where covered
  • Check-out counters 904.4 (38 in. maximum, 2-in. edge protection) - Section 10.3
  • Tray slides 904.5.2 (28 to 34 in.) - Section 10.3
  • Dining counters and bars 902 (28 to 34 in.) - Section 10.1
  • Reception desks used by employees only Employee work area; the public side is a service counter
  • Courtroom stations 807.4 references 902

Visiting area cubicles and counters IBC 1110.12.2 (2021) / 1110.15 (2024): 5 percent of cubicles accessible on both sides

Worked Example

A new pharmacy has a 12-foot drop-off counter at 42 inches high and a separate 6-foot pick-up counter at 42 inches high, each with a 30-inch deep counter top and 52-inch-high acrylic shields that are opaque below 46 inches.

Two types of counters (drop-off and pick-up), so each needs an accessible portion (one of each type).

Parallel approach option: a 36-inch-long portion at 36 inches maximum height, 30 inches deep to match the public counter depth, with a parallel clear floor space.

Vertical barrier: the opaque portion of the shield extends to 46 inches; it must be 43 inches maximum, with only transparent glazing above.

Because the glazing separates staff and customers, provide a voice communication method such as a speaking port or intercom.

Exam Traps

The accessible portion must be as deep as the public counter; a narrow ledge does not count.

The 43-inch limit applies to opaque vertical barriers; transparent glazing above 43 inches is allowed but then needs a voice communication method.

"One of each type" means each function (registration, concierge, pick-up, drop-off), not one per building.

The 24-inch alteration exception is limited to cases where full compliance would reduce existing work stations or mailboxes.

Drive-up only windows are exempt from Section 904 entirely.