Study guide

8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols

Key Takeaways Explain This Topic AI

IBC 1112.1 requires the International Symbol of Accessibility at accessible parking, loading zones, toilet rooms, entrances, check-out aisles and dressing rooms only where not all such elements are accessible, plus areas of refuge and assisted rescue areas.

Signs identifying permanent rooms and spaces need visual characters and raised characters with Grade 2 braille; directional and informational signs need visual characters only.

Raised characters are uppercase, sans serif, raised 1/32 inch, 5/8 to 2 inches high, with baselines between 48 and 60 inches above the floor; braille is below the text and also 48 to 60 inches high.

Tactile signs at doors go on the latch side, with an 18 x 18-inch clear floor area beyond the door swing between closed and 45 degrees open.

Visual characters are at least 40 inches above the floor with a minimum height set by Table 703.2.4 (5/8 inch under 6 feet of viewing distance at 40 to 70 inches high), on a nonglare finish of 19 gloss units maximum.

Last updated: October 2026

8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols

Signage is the "Signs" half of the 4% Alarms and Signs subtopic. Read every sign question twice: first decide which kind of sign is required (IBC 1112), then apply the technical criteria for that kind (A117.1 703).

  • Scoping (IBC 1112)
  • International Symbol of Accessibility (1112.1)

Required accessible elements are identified by the ISA at:

Accessible parking spaces required by 1106.2 (not required where total parking is four or fewer spaces);

Accessible parking spaces required by 1106.3 (not required where spaces are assigned to specific units in I-1, R-2, R-3 and R-4);

  • Accessible passenger loading zones;
  • Accessible toilet or bathing rooms where not all are accessible;
  • Accessible entrances where not all are accessible;

Accessible check-out aisles where not all are accessible (above the aisle, where the aisle number or type identification is);

  • Accessible dressing, fitting and locker rooms where not all are accessible;
  • Areas of refuge (1009.9);
  • Exterior areas for assisted rescue (1009.9);

Accessible lockers in recreational facilities.

Toilet Room Signs (1112.2)

Signs required by the International Plumbing Code to identify toilet and bathing rooms are visual characters, raised characters and braille complying with A117.1. Where pictograms designate toilet rooms, they have visual, raised character and braille text descriptors.

Directional Signs (1112.3)

Directional signs with the ISA and A117.1 visual characters, pointing to the nearest like accessible element, are required at: inaccessible building entrances; inaccessible public toilets and bathing facilities; elevators not serving an accessible route; each separate-sex toilet room (pointing to the family or assisted-use room); exits not providing an accessible means of egress (per 1009.10); and drinking fountains for wheelchair users and standing persons that are not adjacent.

Other Signs (1112.4 and 1112.5)

Assistive listening availability (ISA for hearing loss), tactile EXIT signs at area of refuge doors (1013.4), area of refuge and assisted rescue instructions (1009.11), two-way communication directions (1009.8.2), floor-level signs in exit stairways, amusement ride queue signs, and variable message signs in transportation facilities and emergency shelters.

Which Technical Criteria Apply (A117.1 703.1)

Sign type Requirement

Designations of permanent rooms and spaces (interior and exterior) Visual characters (703.2) and raised characters with braille (703.3, 703.4); exterior signs not at the door they serve need not be tactile

Directional and informational signs Visual characters (703.2) only

Pictograms designating permanent interior rooms 703.5 with a text descriptor directly below the pictogram field (no descriptor needed for "No Smoking," logos or the ISA)

Visual and raised characters may be on one sign or on two separate signs with the same information.

Visual Characters (703.2)

  • Item Requirement
  • Case and style Upper, lower or mixed case; conventional form, not italic, oblique, script or highly decorative

Height (Table 703.2.4) Based on the uppercase "I" and the mounting height and viewing distance; for a baseline 40 to 70 in. high viewed from less than 6 ft: 5/8 in. minimum; over 70 to 120 in. viewed from less than 15 ft: 2 in.; over 120 in. viewed from less than 21 ft: 3 in.; add 1/8 in. per foot beyond those distances

  • Width Uppercase "O" 55 to 110 percent of the "I" height
  • Stroke width 10 to 30 percent of the "I" height
  • Character spacing 10 to 35 percent of character height
  • Line spacing 135 to 170 percent of character height
  • Height above floor 40 in. minimum to the baseline
  • Finish and contrast Nonglare ( 19 gloss units maximum at 60 degrees); light-on-dark or dark-on-light
  • Raised Characters (703.3)
  • Item Requirement
  • Duplication Always duplicated in braille
  • Depth 1/32 in. minimum raised
  • Case and style Uppercase , sans serif
  • Height Uppercase "I" 5/8 in. to 2 in. (1/2 in. minimum where separate visual characters are provided)

Stroke width 15% of "I" height maximum at the top, 30% at the base; 10% minimum where characters are both visual and raised

Spacing 1/8 in. minimum at the top, 1/16 in. at the base, four times the stroke width maximum; 3/8 in. from raised borders

Line spacing 135 to 170 percent

Mounting height 48 in. minimum to the baseline of the lowest raised character and 60 in. maximum to the baseline of the highest

Location at Doors (703.3.11)

Single door: alongside the door on the latch side .

Double doors with one active leaf: on the inactive leaf .

Double doors with two active leaves: to the right of the right-hand door .

No wall space: the nearest adjacent wall.

An 18 x 18 in. minimum clear floor area centered on the raised characters, beyond the arc of any door swing between the closed position and 45 degrees open.

Exception: on the push side of doors with closers and without hold-open devices.

Braille (703.4)

Contracted ( Grade 2 ) braille, domed or rounded dots; capital indicators only before the first word of sentences, proper nouns, individual letters, initials and acronyms; placed below the corresponding text, separated 3/8 in. from raised characters and borders; mounted 48 to 60 in. to the baseline of the braille cells. Elevator car controls are exempt from the mounting heights.

Pictograms and Symbols (703.5 and 703.6)

Pictogram field 6 in. minimum high; no characters or braille in the field; nonglare, contrasting.

Symbols: International Symbol of Accessibility (703.6.3.1), International Symbol of TTY (703.6.3.2), International Symbol of Access for Hearing Loss for assistive listening (703.6.3.3), and a handset with radiating sound waves for volume-controlled telephones (703.6.3.4).

Variable Message Signs (703.7)

VMS characters are uppercase, conventional and nonglare, with heights set by viewing distance and pixel-count rules for high-resolution (16 rows or more) and low-resolution (7 to 15 rows) characters.