Study guide
8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
Key Takeaways Explain This Topic AI
Wheelchair accessible telephones need a clear floor space, a 10-inch maximum reach over an enclosure edge for a parallel approach (20 inches for forward), push-button controls and a 29-inch cord.
Volume-control telephones provide gain up to 20 dB with an intermediate step of 12 dB and automatic reset; TTY keypads are 34 inches minimum high when in use.
ATMs and fare machines need a clear floor space, Section 309 operable parts, a 12-key layout with a raised dot on 5, raised function key symbols, a screen visible from 40 inches, speech output and braille instructions.
Detectable warnings use truncated domes 0.9 to 1.4 inches in base diameter, 0.2 inch high, 1.6 to 2.4 inches on center in a square grid, 24 inches deep, contrasting light-on-dark or dark-on-light.
Two-way communication systems provide both visual and audible signals, handset cords are 29 inches minimum, and telephone entry systems comply with DASMA 303.
Last updated: October 2026
8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
These elements are a small share of the outline (Telephones, Assistive Listening Systems and ATMs 1%; Detectable Warnings 1%), but the questions are usually direct recall of A117.1 numbers.
Where the Scoping Comes From
IBC Chapter 11 does not itself scope public telephones, ATMs or entry systems. Those are scoped in IBC Appendix E (Supplementary Accessibility Requirements), which applies only where the jurisdiction adopts it, and in federal ADA regulations. Appendix E requires, for example, at least one machine of each type at each location where ATMs or fare machines are provided, accessible two-way communication systems used to gain admittance, and wheelchair accessible, volume-control and TTY telephones in specified numbers. Detectable warnings are scoped in IBC 1110.13 (2024; 1110.11 in 2021) for transit platform edges and in A117.1 406.6.2 for street crossings.
Public Telephones (A117.1 Section 704)
- Item Section Requirement
- Clear floor space 704.2.1 Not obstructed by bases, enclosures or seats (drive-up only phones exempt)
- Parallel approach 704.2.1.1 Edge of the enclosure to the face of the telephone 10 in. maximum
Forward approach 704.2.1.2 Front edge of a counter in the enclosure to the face of the telephone 20 in. maximum
- Operable parts 704.2.2 Comply with 309; push-button controls where service is available
- Directories 704.2.3 Comply with 309
- Cord length 704.2.4 29 in. minimum
Volume control 704.3 Gain adjustable up to 20 dB minimum; incremental controls have at least one intermediate step of 12 dB ; automatic reset
TTY 704.4 Permanently affixed within or adjacent to the enclosure
TTY height 704.5 Touch surface of the keypad 34 in. minimum above the floor (not required where seats are provided)
TTY shelf 704.6 Shelf and outlet where phones accommodate portable TTYs, with 6 in. vertical clearance above the TTY area
Visual relay service booth 704.7 Seating and privacy enclosure, two-way video, 20 footcandles diffuse lighting, flat bright green or blue background
Volume-controlled telephones are identified by a handset with radiating sound waves (703.6.3.4) and TTYs by the International Symbol of TTY (703.6.3.2).
ATMs and Fare Machines (A117.1 Section 707)
- Item Section Requirement
- Clear floor space 707.2 In front of the machine (not required at drive-up only machines)
Operable parts 707.3 Comply with 309; each part distinguishable by sound or touch without activation, unless a clear or correct key is provided
- Privacy 707.4 Same degree of privacy of input and output for all users
- Numeric keys 707.5 12-key ascending or descending telephone layout; the 5 key has a single raised dot
Function keys 707.6 Raised symbols: Enter or Proceed = circle ; Clear or Correct = left arrow ; Cancel = X ; Add value = plus ; Decrease value = minus ; keys contrast with the background
Display screen 707.7 Visible from 40 in. above the center of the clear floor space; sans serif characters with the "I" 3/16 in. minimum
Speech output 707.8 Speech enabled; instructions, prompts, verification, errors and all displayed information usable by people with vision impairments; delivered through an industry standard connector or handset; user can repeat, interrupt and adjust volume; receipts provided audibly except for location, date, time, account number and machine identifier
- Input controls 707.9 At least one tactually discernible control for each function
- Braille instructions 707.10 Braille instructions for initiating speech mode
- Two-Way Communication Systems (A117.1 Section 708)
Two-way communication systems, such as entry intercoms, provide both visual and audible signals (708.2); handset cords are 29 in. minimum (708.3); telephone entry systems comply with ANSI/DASMA 303 (708.4). The IBC 1009.8 egress communication system is a separate requirement covered in Section 5.3.
Detectable Warnings (A117.1 Section 705)
- Item Section Requirement
- Standardization 705.2 Standard within a building, facility, site or complex
- Contrast 705.3 Contrast visually with adjacent surfaces, light-on-dark or dark-on-light
- Interior locations 705.4 Differ from adjoining walking surfaces in resiliency or sound-on-cane contact
- Dome size 705.5.1 Base diameter 0.9 to 1.4 in. ; top diameter 50 to 65 percent of the base
Dome height 705.5.2 0.2 in.
- Dome spacing 705.5.3 1.6 to 2.4 in. center to center; 0.65 in. minimum base to base
- Alignment 705.5.4 Square grid
- Depth 705.6 24 in. minimum in the direction of travel
Width 705.6 Full width of the curb ramp run (excluding flares) or blended transition; full width of at-grade rail crossings; full length of public use areas of bus and rail boarding platforms
Placement (705.7)
Perpendicular curb ramps : at the back of curb where the ends of the bottom grade break are in front of the back of curb; on the ramp run within one dome spacing of the bottom grade break where the grade break is behind the back of curb by 60 in. or less; on the lower landing at the back of curb where that distance is more than 60 in.
Parallel curb ramps : on the turning space at the flush transition between street and sidewalk.
Blended transitions : at the back of curb, or at the flush transition for raised crossings and depressed corners.
Cut-through refuge islands : at the island edges, separated by at least 24 in. without warnings.
At-grade rail crossings : on each side, the nearest edge 6 to 15 ft from the centerline of the nearest rail (on the side of any pedestrian gates away from the rail).
Boarding platforms : at the boarding edge.