Study guide
11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102)
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102)
Key Takeaways Explain This Topic AI
An Accessible unit has an accessible route connecting all spaces, a turning space in every room on the route, and doors complying with Section 404, with exceptions such as existing hospital patient room doors 44 inches wide.
At least one bathroom has a lavatory, water closet and tub or shower complying with Sections 603 to 610 (grab bars installed), in a single area with equivalent vanity space.
Kitchens in Accessible units comply with Section 804, and operable windows comply with Section 506 (except kitchen and bathroom windows).
In at least one sleeping area, 5 percent but not less than one bed has a parallel-approach clear floor space on both sides (or one between two beds), an open frame, a 17 to 23-inch height, and a wheelchair charging area.
Table 1108.6.1.1 splits R-1 Accessible units between roll-in shower units and others, and Accessible units are dispersed among the various classes of units.
Last updated: October 2026
11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102)
Accessible units are the highest level of residential accessibility in the IBC. They are scoped in R-1 hotels and motels, R-2 dormitories and similar non-apartment R-2 uses, R-3 transient boarding (2024), R-4, and all I occupancies (Section 11.1).
Unit Requirements (A117.1 1102)
- Item Section Requirement
- Primary entrance 1102.2 On an accessible route; not into a bedroom unless the only entrance
- Accessible route 1102.3.1 Connects all spaces and elements (not unfinished attics or basements)
Turning space 1102.3.2 In all rooms on the route, except toilet rooms not required to comply with 1102.11.2 and closets or pantries 48 in. deep maximum
- Components 1102.3.3 Walking surfaces not steeper than 1:20, doors, ramps, elevators and platform lifts
- Doors 1102.5 Primary entrance and all user passage doorways comply with 404
- Ramps, elevators, lifts 1102.6 to 1102.8 Comply with 405; 407, 408 or 409; 410
Operable parts 1102.9 Lighting controls, panelboards, switches and receptacles, environmental, appliance, plumbing fixture and security or intercom controls comply with 309
- Laundry 1102.10 Washers and dryers comply with 611
- Kitchens 1102.12 Comply with 804
- Windows 1102.13 Operable windows comply with 506.1 (kitchens and bathrooms exempt)
- Storage 1102.14 At least one of each type complies with 905 (kitchen cabinets exempt)
Door exceptions (1102.5) : existing hospital patient sleeping room doors 44 in. wide need no latch-side clearance; secondary toilet rooms need no maneuvering clearance on the bathroom side; no turning space between doors in series; storm, screen and communicating doors between sleeping units exempt from 404.2.5; balcony doors other than the primary entrance need no exterior clearance where the balcony is too small; none in small closets and pantries. IBC 1108.5.3.1 separately allows entry doors to Accessible units in I-2 hospitals to omit latch-side clearance.
Toilet and Bathing (1102.11)
At least one toilet and bathing facility complies with 1102.11.2: the room complies with 603 (turning space, door swing, mirrors), and at least one lavatory, one water closet and either a bathtub or a shower comply with 604 through 610 , with grab bars installed , all in a single toilet/bathing area.
Vanity countertop space (1102.11.2.1) : if other units in the facility have vanity counter space, Accessible units get equivalent space in size and proximity to the lavatory.
Mirrors (1102.11.2.2) : bottom of the reflecting surface 40 in. maximum above the lavatory.
All other toilet and bathing facilities in the unit get Type B-level reinforcement (1102.11.1) unless no Type B units are provided in the structure.
Roll-In Showers
Table 1108.6.1.1 sets how many Accessible units must have roll-in showers (for example, 1 of 4 Accessible units in a 51-to-75-unit hotel; 2 of 8 at 151 to 200 units). Under the 2024 IBC, where all units have showers and none has a bathtub, the required Accessible units may all use standard or alternate roll-in showers with seats, and transfer showers may substitute for all but the minimum number of roll-in showers. In I-1 and I-2 facilities, part of the Accessible units may use the IBC assisted-bathing roll-in shower (1110.2.3) and assisted-toileting water closet (1110.2.2).
Beds and Charging (1102.15, new in 2017)
In at least one sleeping area of the unit, 5 percent , but not less than one bed complies:
Item Requirement
Clear floor space On both sides of the bed, positioned for a parallel approach (one shared space between two beds satisfies both)
- Bed frame At least one bed with an open bed frame (lift devices fit under it)
- Bed height At least one bed 17 to 23 in. from the floor to the top of the uncompressed mattress
Charging The bed clear floor space also serves as a wheelchair charging area complying with 906 (grounded duplex outlet within reach)
Dispersion and Multistory Units
Accessible units are dispersed among the various classes of units (size, price, view, amenities) (1108.6.1.1).
On a multiple-building R-1 site, structures with more than 50 units are counted separately, and smaller structures are counted together.
R-1 multistory units (1108.4 Exception 5) : an accessible route is not required between stories within an individual unit if the accessible level meets the Accessible unit provisions and has sleeping accommodations for at least two persons and a toilet facility.
R-2 non-apartment uses : Accessible units per Table 1108.6.1.1; where bedrooms are grouped into suites, only one bedroom per suite counts toward the required number.
Worked Example
A new 120-unit Group R-2 college dormitory with two-bedroom suites (240 bedrooms):
Bedrooms count as sleeping units (1108.6.2.3), but only one bedroom in each suite may count toward the required Accessible units.
Table 1108.6.1.1 for 201 to 300 units: 10 Accessible units, 3 with roll-in showers.
Each Accessible unit: route, turning spaces, 404 doors, a complying bathroom with installed grab bars, 309 controls, 905 storage, and a compliant bed with clear floor space on both sides, an open frame, 17 to 23 in. height and a charging outlet.
All other dormitory units in the structure are Type B units (structure with four or more units).