Study guide

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108)

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108)

Key Takeaways Explain This Topic AI

Units required to be Type A may be built as Accessible units, and units required to be Type B may be built as Accessible or Type A units (IBC 1108.2).

Group R-1 and R-2 non-apartment uses (dormitories, boarding houses) provide Accessible units per Table 1108.6.1.1, which separates units with and without roll-in showers.

R-2 apartment houses, monasteries and convents with more than 20 units provide Type A units for at least 2 percent, counted across all R-2 units on the site.

In I-1, I-2, R-1, R-2, R-3 and R-4 structures with four or more units intended as residences, every such unit is a Type B unit unless 1108.7 reduces the count.

Without elevator service, only ground-floor (accessible entrance) story units must be Type B; site impracticality, multistory units and flood hazard areas can reduce Type A and B counts.

Last updated: October 2026

  • 11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108)
  • Three Unit Types in the IBC

Unit Standard Intended level Typical use

Accessible unit A117.1 Section 1102 Fully accessible at occupancy Hotels, dormitories, nursing homes, hospitals, assisted living

Type A unit A117.1 Section 1103 Accessible with some adaptable features (removable base cabinets, reinforcement) Apartments: 2% of units in larger R-2 sites

Type B unit A117.1 Section 1104 Basic usability, consistent with the Fair Housing Accessibility Guidelines Every unit in most residential structures with four or more units

IBC 1108.2: units required to be Type A may be designed as Accessible units; units required to be Type B may be designed as Accessible or Type A units. A higher type always satisfies a lower requirement.

Accessible spaces (1108.3) : Rooms and spaces available to the general public or to residents and serving Accessible, Type A or Type B units are accessible, including toilet and bathing rooms, kitchens, living and dining areas and exterior spaces such as patios, terraces and balconies (exceptions: stories exempted by 1108.4, recreational facilities per 1111.2, and impervious Type B decks or balconies up to 4 in. below the interior floor).

Accessible route (1108.4) : At least one accessible route connects accessible entrances with the primary entrance of each Accessible, Type A and Type B unit and with the spaces serving them. Exceptions include site conditions outside the owner's control (a vehicular route with complying parking may substitute), I-3 and R-2 buildings where the required units and all common and public areas are on an accessible route, R-1 multistory units with an accessible level meeting Accessible-unit criteria, and stories exempted under 1108.7.

Group I Scoping (1108.5)

  • Facility Accessible units Type B units
  • I-1 Condition 1 4% , not less than one Every unit in structures with four or more residential units
  • I-1 Condition 2 10% , not less than one Same
  • I-2 nursing homes 50% of each type, not less than one Same
  • I-2 general hospitals, psychiatric and detoxification 10% , not less than one Same
  • I-2 rehabilitation (mobility) 100% -
  • I-3 3% of sleeping units, not less than one per classification level, plus one per special-purpose cell type -

In I-1 and I-2 facilities, a portion of the Accessible units (50% or 90% as listed) may use assisted-toileting water closets (IBC 1110.2.2) and assisted-bathing roll-in showers (1110.2.3) instead of the standard A117.1 fixtures.

  • Group R Scoping (1108.6)
  • R-1 (hotels, motels, transient boarding houses)

Accessible units per Table 1108.6.1.1 , dispersed among classes of units:

  • Total units Without roll-in showers With roll-in showers Total Accessible units
  • 1 to 25 1 0 1
  • 26 to 50 2 0 2
  • 51 to 75 3 1 4
  • 76 to 100 4 1 5
  • 101 to 150 5 2 7
  • 151 to 200 6 2 8
  • 201 to 300 7 3 10
  • 301 to 400 8 4 12
  • 401 to 500 9 4 13
  • 501 to 1,000 2% of total 1% of total 3% of total
  • Over 1,000 20, plus 1 per 100 over 1,000 10, plus 1 per 100 over 1,000 30, plus 2 per 100 over 1,000

On a multiple-building site, structures with more than 50 units are counted individually; structures with 50 or fewer units are counted together. The 2024 IBC adds exceptions where every unit has showers and none has a bathtub. Every R-1 unit intended to be occupied as a residence in a structure with four or more such units is a Type B unit. Small owner-occupied R-1 buildings with five or fewer units are exempt from Chapter 11 (1103.2.11).

R-2

R-2 type Requirement

Live/work units (1108.6.2.1) Nonresidential portion accessible; residential portion Type B where four or more live/work units

Apartment houses, monasteries and convents (1108.6.2.2) More than 20 units : at least 2% , not less than one, Type A units, counting all R-2 units on the site (existing structures do not count) and dispersed; every unit in structures with four or more units is Type B

Other R-2 (dormitories, fraternities, sororities, congregate living, boarding houses) (1108.6.2.3) Accessible units per Table 1108.6.1.1; Type B in structures with four or more units; bedrooms count as sleeping units

R-3 and R-4

R-3 with four or more units intended as residences in a single structure: all Type B. The 2024 IBC also requires Accessible units per Table 1108.6.1.1 in transient R-3 congregate living facilities and boarding houses.

R-4 Condition 1: at least one Accessible sleeping unit; Condition 2: at least two ; Type B in structures with four or more sleeping units.

Reducing Type A and Type B Counts (1108.7)

Section Rule

1108.7.1 No elevator Only units on stories described in 1108.7.1.1 and 1108.7.1.2 must be Type A and Type B. At least one story with an accessible exterior entrance has all its units Type B; additional stories qualify where the slope between their entrance and arrival points within 50 ft is 10 percent or less

1108.7.2 Multistory units A multistory unit without elevator service need not be Type B; with elevator service to one floor, that floor is the primary entry, complies as Type B and contains the living area, kitchen and toilet if provided

1108.7.3 Elevator to lowest residential story only Only units on that story are Type B

1108.7.4 Site impracticality On multiple nonelevator buildings, the Type B count may drop to the percentage of the site with pre-development grades under 10 percent, but not below 20 percent, with additional conditions

1108.7.5 Flood hazard areas Type A and B not required in nonelevator buildings where the required floor elevation is more than 30 in. above, and more than 10 percent slope from, arrival points within 50 ft

Worked Example

A new four-story R-2 apartment building with an elevator has 96 units; a second 24-unit building without an elevator stands on the same site.

Type A: the site has 120 R-2 units (more than 20), so 2% = 2.4, giving 3 Type A units, dispersed among unit types (and among the buildings where units qualify).

Type B, elevator building: all 96 units (any not Type A) are Type B.

Type B, nonelevator building: only units on the story with the accessible entrance (and any other qualifying story under 1108.7.1.2) must be Type B.