Study guide

6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms

Key Takeaways Explain This Topic AI

Where loading zones are provided, one accessible passenger loading zone is required in every continuous 100 linear feet of loading zone space (IBC 1106.9.1).

A loading zone is required at an accessible entrance to licensed medical and long-term care facilities where the stay exceeds 24 hours, at valet parking, and at mechanical access parking garage drop-off and pick-up areas.

The vehicle pull-up space is 96 inches wide and 20 feet long, with an access aisle 67 inches wide in new buildings (60 inches existing), full length, at the same level.

Loading zones, their access aisles and the vehicular routes to and from them need 114 inches of vertical clearance (A117.1 503.5).

New bus boarding and alighting areas are 100 inches long perpendicular to the curb by 60 inches wide (96 x 60 existing), with a 1:48 maximum slope perpendicular to the roadway.

Last updated: October 2026

6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms

Passenger loading zones serve people who are dropped off by car, van, paratransit or taxi. The IBC decides when one is required (1106.9), and A117.1 Section 503 sets the dimensions. Bus stops and rail platforms follow A117.1 Section 805.

Scoping (IBC 1106.9)

  • Section Situation Requirement
  • 1106.9 Any passenger loading zone Must be accessible

1106.9.1 Continuous loading zones One accessible zone in every continuous 100 linear feet maximum of loading zone space

1106.9.2 Licensed medical and long-term care facilities where people receive physical or medical treatment or care and the period of stay exceeds 24 hours A loading zone at an accessible entrance

1106.9.3 Valet parking services A loading zone

1106.9.4 Mechanical access parking garages At least one loading zone at vehicle drop-off and vehicle pick-up areas

The medical facility requirement is triggered by stays longer than 24 hours, so a hospital or nursing home needs one; an outpatient clinic does not by that item alone. A valet operation needs a loading zone even though the patron never parks. IBC 1106.2 also requires an accessible loading zone at public lots where bus, truck and fleet spaces are exempted from the parking table.

Dimensions (A117.1 Section 503)

  • Requirement Section Dimension
  • Vehicle pull-up space 503.2 96 in. wide by 20 ft long minimum
  • Access aisle location 503.3.1 Adjoins an accessible route; may not overlap vehicular ways
  • Access aisle width, new buildings 503.3.2.1 67 in. minimum
  • Access aisle width, existing 503.3.2.2 60 in. minimum
  • Access aisle length 503.3.3 Full length of the vehicle pull-up space
  • Aisle marking 503.3.4 Marked to discourage parking
  • Surfaces 503.4 Comply with 302; slopes not steeper than 1:48 ; aisle at the same level as the pull-up space

Vertical clearance 503.5 114 in. minimum at the pull-up space, access aisle, the vehicular route from an entrance to the loading zone, and the route from the zone to a vehicular exit

Compare the two clearances: 98 inches for van parking (502.6) and 114 inches for loading zones (503.5), because loading zones serve lift-equipped paratransit vehicles. A porte-cochere that is 10 feet high (120 inches) complies; one at 9 feet 2 inches (110 inches) does not.

Because the access aisle must be at the same level as the pull-up space, a design that places the aisle on the raised sidewalk behind a curb fails; the aisle must be at street level, and a curb ramp or blended transition connects it to the walk.

Bus Stops (A117.1 Section 805.2 to 805.4)

  • Item Requirement
  • Surface (805.2.1) Firm and stable

New boarding and alighting area (805.2.2.1) 100 in. clear length measured perpendicular to the curb or roadway edge, by 60 in. clear width measured parallel to the roadway

Existing boarding and alighting area (805.2.2.2) 96 in. by 60 in.

Slope (805.2.3) Parallel to the roadway: same as the roadway to the maximum extent practicable; perpendicular: 1:48 maximum

Connection (805.2.4) Connected to streets, sidewalks or pedestrian paths by an accessible route

Shelters (805.3) A clear floor space entirely within the shelter, connected by an accessible route to a boarding and alighting area

Signs (805.4) Route identification signs use visual characters; schedules, timetables and maps are exempt

IBC 1110.13 (2024; 1110.11 in 2021) requires detectable warnings at transit platform edges bordering a drop-off but exempts bus stops .

Rail Platforms and Stations (805.5 to 805.10)

Platforms slope no more than 1:48 in all directions, except platforms on existing track or roadway may follow that grade parallel to the track.

Platform boarding edges not protected by screens or guards have detectable warnings complying with 705.

At each station entrance identified by a sign, at least one sign with raised characters and braille; each platform has at least one raised character and braille station identification sign.

Public address information is also provided visually; clocks have contrasting, uncluttered faces; escalators are 32 in. clear minimum with demarcated and flat steps per ASME A17.1.

Track crossings on circulation paths comply with 402 and have detectable warnings; wheel flange openings may be 2 1/2 in. maximum.

Worked Example

A new hospital has a 160-foot continuous curbside drop-off under a canopy at the main entrance and offers valet parking at the same curb.

The hospital has stays longer than 24 hours, so an accessible loading zone at an accessible entrance is required (1106.9.2), and the valet stand also requires one (1106.9.3).

160 feet of continuous loading zone requires 2 accessible zones (one per 100 feet or fraction).

Each zone: 96 in. x 20 ft pull-up space with a 67 in. access aisle at street level the full 20 ft length.

The canopy must give 114 in. of clearance over the zones, the aisles and the vehicular route in and out.