Study guide

6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

ICC Accessibility Inspector / Plans Examiner 21

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Administrative and Scoping Provisions

1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures

2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)

2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance

3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors

3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows

4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance

4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts

5 Chapter 5: Accessible Means of Egress

5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions

6 Chapter 6: General Site and Building Elements

6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

7 Chapter 7: Plumbing Elements and Facilities

7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas

8 Chapter 8: Communication Elements and Features

8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings

9 Chapter 9: Special Rooms and Spaces

9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes

10 Chapter 10: Built-in Furnishings and Equipment

10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming

11 Chapter 11: Dwelling and Sleeping Units

11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features

12 Chapter 12: Recreational Facilities

12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities

6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

Key Takeaways Explain This Topic AI

Handrails are required on both sides of stairs and ramps (A117.1 505.2), with exceptions for aisle stairs and ramped aisles in assembly seating.

The top of the gripping surface is 34 to 38 inches above stair nosings, ramp surfaces and walking surfaces, at a consistent height, with 1 1/2 inches minimum clearance to adjacent surfaces.

Circular handrails are 1 1/4 to 2 inches in diameter; noncircular handrails have a 4 to 6 1/4 inch perimeter and a 2 1/4 inch maximum cross-section dimension.

Brackets attached to the bottom of the handrail may obstruct no more than 20 percent of its length and must keep horizontal projections 1 1/2 inches below the handrail.

At stairs, handrails extend horizontally 12 inches beyond the top nosing and slope for one tread depth beyond the bottom nosing; inside handrails on switchback stairs are continuous.

Last updated: October 2026

6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions

Handrails appear in two places on the ICC 21 outline: ramp handrails under Accessible Routes (Section 4.2 of this guide) and stairs and handrails under General Site and Building Elements. This section concentrates on the general Section 505 criteria and their application at stairways. The IBC counterpart is Section 1014, which the 2024 edition renumbered because it inserted a new 1014.3 (lateral location).

Where Handrails Are Required

A117.1 504.7 : Accessible stairs have handrails complying with 505.

A117.1 405.8 : Ramp runs with a rise greater than 6 in. have handrails complying with 505.

A117.1 505.2 : Handrails are on both sides of stairs and ramps. Exceptions: in assembly seating areas, aisle stairs need a handrail only at the side or within the aisle, and ramped aisles serving seats do not need handrails on the sides.

IBC 1014.1 : Handrails are provided for stairways and ramps as required by 1011.11 and 1012.8.

IBC 1014.9 (2021) / 1014.10 (2024) : Stairways have intermediate handrails so all portions of the required width are within 30 in. of a handrail.

Height, Clearance and Profile

Item A117.1 505 IBC 1014 (2021 / 2024)

Height Top of gripping surface 34 to 38 in. above stair nosings, ramp surfaces and walking surfaces, at a consistent height (505.4) 34 to 38 in., uniform (1014.2 / 1014.2)

Clearance 1 1/2 in. minimum between gripping surface and adjacent surfaces (505.5) 1 1/2 in. minimum (1014.7 / 1014.8)

Circular profile 1 1/4 to 2 in. outside diameter (505.7.1) Type I (1014.3.1 / 1014.4.1)

Noncircular profile Perimeter 4 to 6 1/4 in. , cross-section 2 1/4 in. max (505.7.2) Type I adds a 1 in. minimum cross-section and 0.01 in. edge radius

Type II (finger recess) Not recognized Only R-3, within R-2 dwelling units and accessory U (1014.3.2 / 1014.4.2)

  • Surfaces Free of sharp or abrasive elements; edges rounded (505.8) Same (1014.7 / 1014.8)
  • Fittings Handrails do not rotate in fittings (505.9) Same (1014.5 / 1014.6)
  • Lateral location - 2024 only: handrails outside the walking surface within 6 in. of its edge (1014.3)
  • Continuity (A117.1 505.3 and 505.6)

Handrails are continuous within the full length of each stair flight or ramp run .

Inside handrails on switchback or dogleg stairs and ramps are continuous between flights or runs.

Other handrails comply with the extension rules (505.10) and with Section 307 protruding objects.

Gripping surfaces are continuous, without interruption by newel posts, other construction elements or obstructions (505.6), except:

Brackets or balusters attached to the bottom of the handrail are not obstructions if they obstruct 20 percent or less of the handrail length, their horizontal projections are 1 1/2 in. minimum below the bottom of the handrail (reduced by 1/8 in. for each 1/2 in. of perimeter above 4 in.), and edges are rounded;

Along walking surfaces not steeper than 1:20, the bottoms of handrails may be obstructed along their full length where they are integral to crash rails or bumper guards.

Exception to continuity: handrails in aisles serving seating may be discontinuous to provide access to seats and crossovers.

Extensions (A117.1 505.10)

Location Extension

Ramps, top and bottom (505.10.1) Horizontally above the landing 12 in. minimum beyond the top and bottom of ramp runs

Top of stairs (505.10.2) Horizontally above the landing 12 in. minimum, beginning directly above the landing nosing

Bottom of stairs (505.10.3) At the slope of the stair flight for a horizontal distance equal to one tread depth beyond the bottom tread nosing

Termination Return to a wall, guard or the landing surface, or continuous to the handrail of an adjacent flight

Extensions are not required at continuous inside turns, in aisles serving seating where handrails are discontinuous, or, in alterations , where full extensions would be hazardous due to plan configuration. IBC 1014.6 (2021) / 1014.7 (2024) states the same top, bottom and ramp extensions and exempts handrails within dwelling units that are not required to be accessible, which may run only from the top riser to the bottom riser.

A117.1-2017 does not require an added horizontal segment after the one-tread-depth bottom extension: the bottom extension continues at the stair slope for one tread depth and then returns or continues to the next flight.

Worked Example

A new exit stair with 11-inch treads uses 1 1/2-inch steel pipe handrails (1.9 in. outside diameter) on both sides, mounted with 1 1/4 inches of clearance to a CMU wall, 36 inches above the nosings. At the top, the handrail stops directly above the top nosing; at the bottom, it extends 11 inches at the stair slope and returns to the wall.

Profile and height comply.

Clearance fails: 1 1/2 inches minimum is required.

Top extension fails: the handrail must extend 12 inches horizontally beyond the landing nosing.

Bottom extension complies: one tread depth (11 inches) at the slope of the flight, then a return.