Study guide
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas
Key Takeaways Explain This Topic AI
Recreational facilities serving Type A or Type B units must have 25 percent, but not less than one, of each type accessible, and such pools need not provide accessible means of entry into the water.
Pools with 300 linear feet or more of pool wall need two accessible means of entry, at least one a pool lift or sloped entry; smaller pools need one.
Pool lifts sit where the water is 48 inches deep or less, with the raised seat 16 inches from the edge, a 16 to 19-inch seat height, 18-inch submersion, 300-pound capacity and unassisted operation from deck and water.
Sloped entries reach 24 to 30 inches below the water level with two handrails 33 to 38 inches apart; wading pools need a sloped entry to the deepest part.
Hot tubs and spas need one means of entry (lift, transfer wall or transfer system); where clustered, 5 percent but not less than one of each type must comply.
Last updated: October 2026
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas
The Recreational Facilities domain is 6% of the exam, split between General Recreational Facilities (3%) and Swimming Pools, Wading Pools, Hot Tubs and Spas (3%). The IBC scopes recreation in Section 1111 (the same number in 2021 and 2024), and A117.1 Chapter 10 provides the technical criteria. Note that A117.1-2017 places recreation in Chapter 10 (the 2009 edition used Chapter 11).
Scoping for Recreational Facilities (IBC 1111.1 to 1111.3)
Section Facility Requirement
1111.2.1 R-2 and R-4 recreational facilities serving Accessible units Every recreational facility of each type serving them is accessible
1111.2.2 R-2, R-3, R-4 facilities serving a single building with Type A or Type B units 25 percent , not less than one, of each type of recreational facility accessible, counting every facility of each type on the site
1111.2.3 Facilities serving multiple buildings with Type A or Type B units on a site 25 percent, not less than one, of each type serving each building
1111.3 All other occupancies Recreational facilities are accessible
An apartment complex with two pools serving its Type B buildings needs at least one accessible pool (25% of 2, rounded up). Under 1111.4.14 Exception 3, pools required to be accessible by 1111.2.2 and 1111.2.3 need not provide accessible means of entry into the water , only an accessible route to and around them.
Pool Scoping (IBC 1111.4.14)
Swimming pools, wading pools, cold baths, hot tubs and spas are accessible and on an accessible route, with these exceptions:
Catch pools at the end of a water slide flume need no accessible means of entry if part of the catch pool edge is on an accessible route.
Where spas, cold baths or hot tubs are clustered , at least 5 percent , not less than one of each type in each cluster, are accessible and on an accessible route.
Residential recreation pools under 1111.2.2 and 1111.2.3 need no accessible means of entry.
Raised diving boards and diving platforms (1111.4.14.1) and water slides (1111.4.14.2) need not be accessible or on an accessible route.
Means of Entry (A117.1 1009.1)
Facility Requirement
Swimming pools (1009.1.1) At least two accessible means of entry: pool lifts, sloped entries, transfer walls, transfer systems or pool stairs; at least one must be a pool lift or a sloped entry
Pools with less than 300 linear feet of pool wall Only one accessible means of entry required (still a lift or sloped entry under the same rule)
Wave pools, leisure rivers, sand bottom pools and pools with access limited to one area One means of entry, which must be a lift, a sloped entry or a transfer system
- Catch pools No means of entry if the edge is on an accessible route
- Wading pools (1009.1.2) At least one sloped entry
Hot tubs and spas (1009.1.3) At least one means of entry: lift, transfer wall or transfer system; in clusters, 5 percent, not less than one
Pool Lifts (1009.2)
Item Requirement
Location Where the water level is 48 in. maximum (not required where the whole pool is deeper; with multiple lifts, only one must be in such an area)
Seat location Raised seat centerline over the deck, 16 in. minimum from the pool edge; deck slope 1:48 maximum between seat and edge
Clear deck space On the side of the seat opposite the water, 36 in. wide, extending forward 52 in. (new; 48 in. existing) from a line 12 in. behind the rear edge of the seat; slope 1:48 maximum
- Seat height Stops at 16 to 19 in. above the deck in the raised position
- Seat 16 in. minimum wide, with a back rest, firm and stable
Footrests and armrests Footrests that move with the seat (not required on spa lifts); the armrest opposite the water removable or folding
- Operation Unassisted operation from both the deck and water levels; controls unobstructed and per 309.4
- Submerged depth Seat submerges 18 in. minimum below the stationary water level
- Capacity 300 lb minimum, with a static load of 1.5 times the rated load
- Sloped Entries (1009.3)
Comply with 402, 403 and 405 (1:12 maximum ramp, landings) as modified: surfaces need not be slip resistant; swimming pool sloped entries extend to 24 to 30 in. below the stationary water level, with a landing at that depth where landings are required; wading pool entries extend to the deepest part. At least two handrails complying with 505 are provided, 33 to 38 in. apart; extensions are not required at the bottom landing, and wading pool entries are exempt from the handrail rules.
Transfer Walls (1009.4)
- Item Requirement
- Clear deck space 60 x 60 in. at the base, slope 1:48, centered on the grab bar or between two bars
- Height 16 to 19 in. above the deck
- Depth and length 12 to 16 in. deep; 60 in. minimum long, centered on the deck space
Grab bars At least one, perpendicular to the pool wall, full depth of the wall, top 4 to 6 in. above the wall; 24 in. clearance on both sides of a single bar, or 24 in. between two bars
Transfer Systems (1009.5)
A transfer platform 19 in. deep and 24 in. wide at the head, at 16 to 19 in. high, with a 60 x 60 in. transfer space centered on a 24-in. side; transfer steps 8 in. maximum high, treads 14 to 17 in. deep and 24 in. wide, reaching 18 in. below the water; grab bars 4 to 6 in. above each step and the platform, on at least one side.
Pool Stairs (1009.6)
Comply with 504.2 through 504.5 (risers may be outside 4 to 7 in. if uniform); at least two handrails 20 to 24 in. apart; no bottom extensions required. Pool stairs count as a means of entry only for the second required means, since one must be a lift or sloped entry.