Study guide
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight
Key Takeaways Explain This Topic AI
Table 1109.2.2.1 requires 1 wheelchair space for 4 to 25 seats, 2 for 26 to 50, 4 for 51 to 100, 5 for 101 to 300, 6 for 301 to 500, then 6 plus 1 per 150 up to 5,000 and 36 plus 1 per 200 above 5,000.
Each required wheelchair space has a companion seat beside it, with shoulder alignment in row seating, and at least 5 percent of aisle seats are designated aisle seats with folding armrests.
A single wheelchair space is 36 inches wide (33 inches each when two are adjacent) and 52 inches deep for front or rear entry in new buildings (48 inches existing), or 60 inches deep for side entry.
Wheelchair spaces adjoin but do not overlap the accessible route or the required aisle width, except that new-building spaces may extend 4 inches into the aisle.
Wheelchair space locations are dispersed horizontally, at varied distances and by seating type, with the minimum number of locations set by A117.1 Table 802.10.
Last updated: October 2026
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight
The ICC 21 outline lists Special Rooms and Spaces as a single 8% subtopic, about six questions. Assembly seating dominates it because scoping (IBC 1109.2) and technical criteria (A117.1 802) both contain tables.
- IBC Scoping (1109.2)
- Wheelchair Spaces (Table 1109.2.2.1)
- Seating capacity Minimum wheelchair spaces
- 4 to 25 1
- 26 to 50 2
- 51 to 100 4
- 101 to 300 5
- 301 to 500 6
- 501 to 5,000 6, plus 1 for each 150, or fraction thereof, between 501 and 5,000
- 5,001 and over 36, plus 1 for each 200, or fraction thereof, over 5,000
Worked example for 1,800 seats: 6 + (1,800 - 500)/150 = 6 + 8.67, rounded up to 9, for 15 wheelchair spaces.
- Section Requirement
- 1109.2.1 Services A service on an inaccessible level is also provided on an accessible level
1109.2.2.2 Luxury boxes, club boxes and suites Each box or suite in arenas, stadiums and grandstands uses Table 1109.2.2.1 individually
- 1109.2.2.3 Other boxes Total wheelchair spaces from the table, located in at least 20 percent of the boxes
- 1109.2.3 Companion seats At least one companion seat for each required wheelchair space
1109.2.4 Multilevel dispersion Wheelchair spaces on the main floor and on one of each two additional floor or mezzanine levels; exceptions where a second level has 25 percent or less of the seats in worship spaces, or 25 percent or less and 300 or fewer seats elsewhere; team and player seating need not be dispersed
1109.2.5 Designated aisle seats At least 5 percent , but not less than one, of aisle seats, located closest to accessible routes
1109.2.6 Lawn seating Lawn and exterior overflow seating areas connect to an accessible route
1109.2.8 Performance areas An accessible route directly connects the performance area to the seating area where a circulation path does; routes connect performance areas to ancillary performer areas
1109.2.9 Dining and drinking areas All interior and exterior floor areas accessible and on an accessible route; exceptions for 1104.4 levels, mezzanines with less than 25 percent of the dining area and the same services, and tiered sports dining with routes to at least 25 percent
Wheelchair spaces are required only with fixed seating ; movable chairs can be removed to create space.
Technical Criteria (A117.1 Section 802)
- Item Section Requirement
- Floor 802.2 Slope not steeper than 1:48
- Width 802.3 36 in. for a single space; 33 in. each where two spaces are adjacent
- Depth, new 802.4.1 52 in. where entered from the front or rear; 60 in. where entered only from the side
- Depth, existing 802.4.2 48 in. front or rear entry; 60 in. side entry
- Approach 802.5 Adjoins an accessible route; the route may not overlap the space
Aisle overlap 802.5.1 May not overlap the required aisle width, except new-building space depth may overlap 4 in.
Integration 802.6 An integral part of the seating area, not segregated
Companion seat 802.7 Beside each wheelchair space; equivalent in size, quality, comfort and amenities; may be movable
Shoulder alignment 802.7.2 In row seating, companion seat aligned with the wheelchair user's shoulder, assumed 36 in. or more from the front and 12 in. or more from the rear of the space; companion seat floor at the same elevation
Designated aisle seats 802.8 Folding or retractable armrests on the aisle side where seats nearby have armrests; identified by a sign or marker
Lines of Sight (802.9)
Seated spectators : lines of sight comparable to seated spectators nearby, either over the heads of the first row in front or between heads and over shoulders.
Standing spectators : where spectators in front are expected to stand, the front of the wheelchair space is 12 in. maximum from the back of the seat in front, and the floor of the wheelchair space is raised per Table 802.9.2.2 (for example, with 8-inch risers and rows 33 to 44 inches deep, the wheelchair space is 30 inches above the tread in front).
Dispersion (802.10)
- Total seating Minimum wheelchair space locations (Table 802.10)
- Up to 150 1
- 151 to 500 2
- 501 to 1,000 3
- 1,001 to 5,000 3, plus 1 for each 1,000 seats or portion above 1,000
- 5,001 and over 7, plus 1 for each 2,000 seats or portion above 5,000
Locations are dispersed horizontally (not required with 300 or fewer seats if they are in the 2nd and 3rd quartiles of the row length), at a variety of distances from the event (exceptions for bleachers at points of entry, movie theaters with 300 or fewer seats, and other spaces with 300 or fewer seats whose locations are in the front 50 percent of rows), and by type where distinct seating areas have different amenities. In motion picture theaters, locations are on a riser or cross-aisle in tiered seating and within the rear 60 percent of seats or within the 40th to 100th percentile of vertical viewing angles. Where charging stations are provided at wheelchair space locations, they comply with Section 906.
Note the difference: Table 1109.2.2.1 counts wheelchair spaces ; Table 802.10 counts locations , each of which may contain several spaces and companion seats.
Sign Language Interpreter Stations (802.11, new in 2017)
Where provided: a level clear floor area 24 in. deep x 36 in. wide ; located so seating within a 60-degree arc each side and within 65 ft has sight lines to the station from 36 to 72 in. above the station floor; 10 footcandles of lighting at 48 in. above the station floor; a flat, smooth, monochromatic, low-luster backdrop where a permanent wall is less than 10 ft behind.
Worked Example
A 420-seat theater with fixed seats on a single level:
Wheelchair spaces: 301 to 500 seats = 6 , each with a companion seat.
Designated aisle seats: 5% of the aisle seats (if 60 aisle seats, 3).
Wheelchair space locations (Table 802.10): 151 to 500 seats = 2 locations, dispersed horizontally and at different distances (the 300-seat exceptions do not apply at 420 seats).
Each space 36 in. wide (33 in. if paired) and 52 in. deep if entered from the front or rear.