Study guide
9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics
ICC Accessibility Inspector / Plans Examiner 21
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping 1.2 General Administration: Definitions, Conventions, and Code Editions 1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy 1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
2 Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes 2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings 2.3 Knee and Toe Clearances 2.4 Unobstructed and Obstructed Reach Ranges 2.5 Protruding Objects and Vertical Clearance
3 Chapter 3: Accessible Routes — Route Scoping, Entrances, and Doors
3.1 Accessible Route Scoping, Components, Slopes, and Clear Width 3.2 Accessible Entrances: Number, Location, and Power-Operated Doors 3.3 Doors, Doorways, and Gates: Clear Width and Maneuvering Clearances 3.4 Door Hardware, Forces, Closing Speed, Door Surfaces, and Windows
4 Chapter 4: Accessible Routes — Ramps, Curb Ramps, and Conveyance
4.1 Ramps: Slopes, Landings, and Clearances 4.2 Ramp Handrails, Edge Protection, and Cross Slopes 4.3 Curb Ramps, Blended Transitions, and Detectable Warnings at Crossings 4.4 Elevators, LULA Elevators, and Platform Lifts
5 Chapter 5: Accessible Means of Egress
5.1 Accessible Means of Egress: Number, Components, Elevators, and Stairways 5.2 Elevators, Platform Lifts, Areas of Refuge, and Exterior Areas for Assisted Rescue 5.3 Two-Way Communication, Egress Signage, and Instructions
6 Chapter 6: General Site and Building Elements
6.1 Accessible Parking: Scoping, Van Spaces, Dimensions, and Signs 6.2 Passenger Loading Zones, Bus Stops, and Rail Platforms 6.3 Site Accessibility: Site Routes, Routes Through Parking, EV Charging, and Fuel Dispensers 6.4 Stairways: Treads, Risers, Nosings, Visual Contrast, and Lighting 6.5 Stair Handrails: Location, Height, Profile, Continuity, and Extensions
7 Chapter 7: Plumbing Elements and Facilities
7.1 Water Closets and Toilet Compartments 7.2 Grab Bars: Locations, Cross Sections, Spacing, Strength, and Assisted Toileting 7.3 Toilet Rooms, Lavatories, Sinks, Mirrors, Urinals, and Accessories 7.4 Bathtubs, Shower Compartments, and Seats 7.5 Plumbing Scoping: Family Rooms, Adult Changing Stations, Drinking Fountains, Laundry, and Saunas
8 Chapter 8: Communication Elements and Features
8.1 Visible Alarms and Assistive Listening Systems 8.2 Accessible Signage: Visual Characters, Raised Characters, Braille, Pictograms, and Symbols 8.3 Telephones, ATMs and Fare Machines, Two-Way Communication Systems, and Detectable Warnings
9 Chapter 9: Special Rooms and Spaces
9.1 Assembly Areas: Wheelchair Spaces, Companion Seats, Dispersion, and Lines of Sight 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics 9.3 Kitchens and Kitchenettes
10 Chapter 10: Built-in Furnishings and Equipment
10.1 Dining Surfaces and Work Surfaces 10.2 Sales and Service Counters and Windows 10.3 Check-Out Aisles, Food Service Lines, Benches, Storage, Charging Stations, and Gaming
11 Chapter 11: Dwelling and Sleeping Units
11.1 Scoping Accessible, Type A, and Type B Units (IBC 1108) 11.2 Type A Units (A117.1 Section 1103) 11.3 Type B Units (A117.1 Section 1104) 11.4 Accessible Units: Hotels, Dormitories, Health Care and Residential Care (A117.1 Section 1102) 11.5 Type C (Visitable) Units and Units with Communication Features
12 Chapter 12: Recreational Facilities
12.1 Swimming Pools, Wading Pools, Hot Tubs, and Spas 12.2 Play Areas and Amusement Rides 12.3 Sports Facilities, Exercise Equipment, Golf, Boating, Fishing, and Shooting Facilities
9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics
Key Takeaways Explain This Topic AI
At least 5 percent, but not less than one, of each type of dressing, fitting and locker room in each cluster is accessible, with a turning space, a 903 bench and limits on door swing (IBC 1110.14 or 1110.17; A117.1 803).
Each courtroom is accessible: a wheelchair space in the jury box, gallery wheelchair spaces from Table 1109.2.2.1, an assistive listening system, and work stations on an accessible route.
Elevated courtroom employee stations need only be capable of later vertical access if a ramp, lift or elevator can be added without reconfiguring the courtroom or extending its electrical system.
Group I-3 facilities make at least 3 percent of sleeping units Accessible units (at least one per classification level) plus one of each special holding or housing cell type.
Self-service storage needs 5 percent of spaces accessible up to 200 spaces, and 10 plus 2 percent of units over 200 above that.
Last updated: October 2026
- 9.2 Dressing and Locker Rooms, Courtrooms, Detention Cells, Self-Storage, and Classroom Acoustics
- Dressing, Fitting and Locker Rooms
Scoping (IBC 1110.14 in 2021; 1110.17 in 2024): where provided, at least 5 percent , but not less than one, of each type of use in each cluster is accessible. IBC 1112.1 requires the ISA at accessible rooms where not all are accessible. In existing buildings, IEBC 306.7.14 (2021) or 306.7.16 (2024) permits one accessible room on the same level where providing it at the same location is technically infeasible, with one for each sex where separate-sex facilities exist.
Technical criteria (A117.1 803):
- Section Requirement
- 803.2 A turning space within the room
803.3 Doors may not swing into the room unless a clear floor space complying with 305.3 is provided within the room beyond the arc of the door swing
803.4 A bench complying with 903 (42 in. long, 20 to 24 in. deep, 17 to 19 in. high, back support or wall, 250 lb)
- 803.5 Coat hooks within a forward or side reach range; shelves 40 to 48 in. above the floor
- Judicial Facilities (IBC 1109.4 and A117.1 807)
- Item Requirement
- Courtrooms (1109.4.1) Each courtroom is accessible
- Jury box (1109.4.1.1) A wheelchair space within the jury box; adjacent companion seating not required
Gallery seating (1109.4.1.2) Wheelchair spaces per Table 1109.2.2.1 and designated aisle seats per 1109.2.5; technical criteria per A117.1 802 (807.5)
Assistive listening (1109.4.1.3) Required in every courtroom, with receivers per Table 1109.2.7.1
Employee work stations (1109.4.1.4) Judge's bench, clerk's, bailiff's, deputy clerk's and court reporter's stations on an accessible route; vertical access to elevated stations is not required at initial construction if a ramp, lift or elevator can later be installed without reconfiguring or extending the courtroom or extending the electrical system
Other work stations (1109.4.1.5) Litigant's and counsel stations, including the lectern, accessible
Holding cells (1109.4.2) Central holding cells: one accessible cell of each type (adult male, juvenile male, adult female, juvenile female), or at least one where not separated; court-floor holding cells: each courtroom served by one accessible cell of each type (cells may serve several courtrooms)
A117.1 807: each raised or depressed area provides a turning space (not required at jury box levels without wheelchair spaces); a clear floor space within each jury box and witness stand (in alterations, the wheelchair space may be outside a raised jury box or witness stand where ramps or lifts would encroach on egress); courtroom stations comply with 902 work surface criteria. Platform lifts are permitted to jury boxes, witness stands and raised or depressed courtroom areas (IBC 1110.9 Item 5 in 2021; 1110.11 in 2024).
Detention and Correctional Facilities
Scoping (IBC 1108.5.5): in Group I-3, at least 3 percent of sleeping units, but not less than one in each classification level , are Accessible units. In addition, at least one cell serving each special purpose (orientation, protective custody, administrative or disciplinary detention or segregation, detoxification and medical isolation) is an Accessible unit; cells designed without protrusions for suicide prevention need not have grab bars. Medical care facility cells required to be Accessible are in addition to medical isolation cells. Visiting areas (IBC 1110.12.2 in 2021; 1110.15 in 2024) make at least 5 percent of cubicles, but not less than one, accessible on both the visitor and detainee sides, and at least one counter where counters are provided.
Technical criteria (A117.1 806):
- Section Requirement
- 806.2.1 Turning space within the cell
- 806.2.2 Where benches are provided, at least one complies with 903
- 806.2.3 Where beds are provided, a clear floor space on at least one side positioned for a parallel approach
- 806.2.4 Toilet and bathing facilities in the cell comply with 603
806.3.1 Where audible emergency alarms serve cells, visible alarms per 702 (not required where inmates are not allowed independent egress)
- 806.3.2 Telephones in cells have volume controls per 704.3
- Self-Service Storage (IBC 1109.3)
- Total spaces Accessible spaces
- 1 to 200 5%, but not less than 1
- Over 200 10, plus 2% of the units over 200
Accessible spaces are dispersed through the classes of spaces (size, climate control), but need not exceed the table count where there are more classes than required spaces, and may all be in one building of a multiple-building facility. A facility with 450 spaces needs 10 + 0.02 x 250 = 15 accessible spaces.
Transportation Facilities (A117.1 805)
Bus stops, shelters, signs and rail platforms are covered in Section 6.2 of this guide.
Enhanced Classroom Acoustics (A117.1 808, new in 2017)
Applies to classrooms of 20,000 cubic feet or less that are required to provide enhanced acoustics (the 2021 IEBC, for example, requires A117.1 808 for certain Group E additions, Level 3 alterations and changes of occupancy).
Item Requirement
Reverberation, performance method T60 at 500, 1,000 and 2,000 Hz: 0.6 s in rooms up to 10,000 cu ft; 0.7 s in rooms over 10,000 and under 20,000 cu ft; field verified per ASTM E2235
Reverberation, prescriptive method Noise reduction coefficient (NRC) ratings of finishes meeting the standard's equations
Ambient sound 35 dBA and 55 dBC maximum from sources outside the classroom, and the same from sources inside, measured at 36 to 42 in. high in the furnished, unoccupied room