1 Introduction
About the ICC CBO Exam How to Use This Guide
2 Chapter 1: Legislative and Alternative Methods
1.1 Code Adoption and Local Amendments 1.2 Board of Appeals and Alternative Materials/Methods
3 Chapter 2: Code Enforcement and Due Process
2.1 Permits and Construction Documents 2.2 Inspection Process and Certificate of Occupancy 2.3 Notices, Violations, and Stop Work Orders 2.4 Right of Entry and Administrative Warrants 2.5 Due Process and Equal Protection 2.6 Hazard Abatement and Emergency Measures 2.7 Tort Liability and Sovereign Immunity 2.8 Code Enforcement Prosecution and Civil Remedies
4 Chapter 3: Human Resources in Code Administration
3.1 Anti-Discrimination Laws in Public Employment (ADA, Title VII) 3.2 Wage, Hour, and Safety Laws (FLSA, OSHA) 3.3 Personnel Discipline, Performance, and Dismissal 3.4 Labor Relations, Grievances, and Due Process
5 Chapter 4: Reports and Public Records
4.1 Records Management and Document Retention 4.2 Public Records Disclosure and Freedom of Information Laws
6 Chapter 5: Customer Service and Public Relations
5.1 Customer Service Principles in Public Administration 5.2 Public Relations, Media, and Stakeholder Communication 5.3 Interagency Cooperation and Coordination 5.4 Conflict De-escalation and Dispute Resolution 5.5 Feedback Strategy and Continuous Service Improvement
7 Chapter 6: Personnel Administration
6.1 Job Descriptions and Personnel Needs Assessment 6.2 Recruitment, Selection, and Onboarding Processes 6.3 Staff Training, Professional Goals, and Certification 6.4 Performance Appraisals and Supervision Standards
8 Chapter 7: Financial Management
7.1 Operating and Capital Budget Development 7.2 Fee Structures, Valuation, and Revenue Generation 7.3 Financial Controls, Audits, and Cost Recovery
9 Chapter 8: Department Records and Information Systems
8.1 Permitting and Code Enforcement Reporting Systems 8.2 Electronic Document Review and Workflow Integration 8.3 Information Security, Data Privacy, and Disaster Recovery
10 Chapter 9: Architectural Plan Review
9.1 Use and Occupancy Classifications (IBC Chapter 3) 9.2 Construction Types and Height/Area Limitations (IBC Chapters 5 & 6) 9.3 Fire and Smoke Protection Features (IBC Chapters 7 & 8) 9.4 Fire Protection Systems (IBC Chapter 9) 9.5 Means of Egress and Occupant Load (IBC Chapter 10)
11 Chapter 10: Structural Plan Review
10.1 Design Loads and Structural Criteria (IBC Chapter 16) 10.2 Materials Standards and Foundations (IBC Chapters 18-23)
12 Chapter 11: Building Systems and Energy Code Plan Review
11.1 Mechanical (IMC) and Fuel Gas (IFGC) Plan Review 11.2 Plumbing Systems (IPC) and Backflow Protection 11.3 Electrical (NEC/NFPA 70) and Energy (IECC) Code Plan Review
13 Chapter 12: Field Inspection and Construction Compliance
12.1 Accessibility Standards and ANSI A117.1 Compliance 12.2 Soil Conditions, Excavation, and Site Inspections 12.3 Footing and Foundation Inspections 12.4 Concrete, Masonry, Steel, and Wood Structural Inspections 12.5 Rough-in MEP Inspections 12.6 Special Inspections and Quality Assurance (IBC Chapter 17) 12.7 Existing Buildings, Alterations (IEBC), and Final Inspections
9.1 Use and Occupancy Classifications (IBC Chapter 3)
Key Takeaways Explain This Topic AI
Occupancy classification is the foundational step of plan review, determining all subsequent fire safety, egress, and heights/areas parameters.
The ten primary occupancy groups in IBC Chapter 3 represent varying hazards: Assembly (A), Business (B), Educational (E), Factory (F), High Hazard (H), Institutional (I), Mercantile (M), Residential (R), Storage (S), and Utility (U).
Daycare facilities are classified by age and occupant count: five or fewer children is Group R-3, six or more children older than 2.5 years is Group E, and six or more children 2.5 years or younger is Group I-4.
Accessory occupancies must not exceed 10% of the area of the story and do not require fire-resistance-rated separation from the main occupancy (except for Group H or specific tables).
Nonseparated occupancies require no fire separation but apply the most restrictive occupancy's height, area, and sprinkler requirements to the entire structure, whereas separated occupancies use fire-rated assemblies and the unity equation calculation.
Last updated: July 2026
- Use and Occupancy Classifications (IBC Chapter 3)
- Introduction to Use and Occupancy Classifications
A building’s occupancy classification is the fundamental starting point of any building code plan review. Under the International Building Code (IBC), every structure is categorized into one or more use groups based on the nature of the activities conducted within its walls. The Certified Building Official (CBO) and the plan reviewer must verify this classification before any other parameters—such as height, area, construction type, means of egress, or fire protection systems—can be determined.
Occupancy classification identifies the inherent fire hazards, occupant densities, and occupant capabilities associated with a specific use. For example, a building housing sleeping occupants (Group R) or individuals who are restrained or incapacitated (Group I) presents a significantly higher life-safety risk than an office building (Group B), thus triggering more stringent code controls.
The Ten Primary Occupancy Groups
IBC Chapter 3 classifies all buildings and structures into ten primary occupancy groups. Understanding these classifications, along with their subgroups and threshold criteria, is essential for CBO exam candidates.
1. Assembly (Group A)
Group A occupancies are designed for civic, social, or religious functions, recreation, food and drink consumption, or awaiting transportation. It is subdivided into five subgroups:
Group A-1 : Assembly uses, usually with fixed seating, intended for the production and viewing of the performing arts or motion pictures (e.g., movie theaters, concert halls, theaters with stages).
Group A-2 : Assembly uses intended for food and/or drink consumption (e.g., restaurants, taverns, bars, nightclubs, banquet halls). These spaces frequently feature high occupant loads and concentrated layouts.
Group A-3 : Assembly uses intended for worship, recreation, or amusement and other assembly uses not classified elsewhere (e.g., churches, community halls, gymnasiums without spectator seating, bowling alleys, art galleries, museums).
Group A-4 : Assembly uses intended for viewing of indoor sporting events and activities with spectator seating (e.g., indoor arenas, swimming pools, tennis courts with bleachers).
Group A-5 : Assembly uses intended for participation in or viewing of outdoor activities (e.g., stadiums, amusement parks, grandstands, outdoor arenas).
Note
Assembly rooms or spaces with an occupant load of fewer than 50 persons, or that are accessory to another occupancy, are generally classified as Group B or as accessory to the main occupancy.
2. Business (Group B)
Group B includes the use of a building for office, professional, or service-type transactions, including storage of records and accounts. Typical examples include banks, civic administration offices, professional service suites (attorneys, architects, engineers), post offices, laboratories, and outpatient clinics (ambulatory care). Educational occupancies above the 12th grade (colleges and universities) are also classified as Group B.
3. Educational (Group E)
Group E covers the use of a building by six or more persons at any one time for educational purposes through the 12th grade. It also includes daycare facilities providing custodial care for more than five children who are older than 2.5 years of age. A critical threshold for daycare facilities is the age of the children: if the facility cares for five or fewer children, it is classified as Group R-3, whereas if it cares for children 2.5 years of age or younger, it is typically classified as Group I-4.
4. Factory and Industrial (Group F)
Group F is designated for assembly, disassembly, fabrication, finishing, manufacturing, packaging, repair, or processing of materials that are not classified as Group H high-hazard. It is divided into:
Group F-1 (Moderate-Hazard) : Manufacturing of combustible materials (e.g., auto repair, commercial kitchens, woodworking, plastics, textiles).
Group F-2 (Low-Hazard) : Processing or manufacturing of noncombustible materials that do not involve a significant fire hazard (e.g., beverage production, brick and masonry manufacturing, glass fabrication).
5. High Hazard (Group H)
Group H involves the manufacturing, processing, generation, or storage of materials that constitute a physical or health hazard in quantities in excess of those allowed in control areas. These are classified into:
Group H-1 : Buildings containing materials that present a detonation hazard.
Group H-2 : Buildings containing materials that present a deflagration hazard or a hazard from accelerated burning.
Group H-3 : Buildings containing materials that readily support combustion or present a physical hazard.
Group H-4 : Buildings containing materials that are health hazards (e.g., highly toxic, toxic, or corrosive materials).
Group H-5 : Semiconductor fabrication facilities and research and development areas.
The determination of a Group H occupancy is based on the Maximum Allowable Quantities (MAQ) of hazardous materials per control area (IBC Table 307.1(1) and Table 307.1(2)).
6. Institutional (Group I)
Group I is designated for facilities where occupants are cared for or confined in a supervised environment.
Group I-1 : Facilities where more than 16 occupants (excluding staff) reside on a 24-hour basis and receive custodial care (e.g., assisted living, group homes). It is divided into Condition 1 (occupants are capable of self-preservation without physical assistance) and Condition 2 (occupants require physical assistance to respond to an emergency).
Group I-2 : Facilities providing medical, surgical, obstetric, psychiatric, nursing, or custodial care on a 24-hour basis for occupants who are not capable of self-preservation (e.g., hospitals, nursing homes). Condition 1 applies to nursing homes; Condition 2 applies to hospitals.
Group I-3 : Facilities inhabited by more than five persons who are under restraint or security (e.g., prisons, jails, reformatories). Conditions 1 through 5 are established based on the level of restraint and free movement.
Group I-4 : Daycare facilities providing custodial care for more than five persons of any age (excluding children older than 2.5 years of age, who are Group E) for less than 24 hours per day.
7. Mercantile (Group M)
Group M covers buildings used for the display and sale of merchandise, including stocks of goods accessory to such spaces. Typical examples include department stores, drug stores, retail shops, supermarkets, and wholesale markets.
8. Residential (Group R)
Group R is designated for buildings containing sleeping accommodations.
Group R-1 : Residential occupancies containing sleeping units where the occupants are primarily transient in nature (e.g., hotels, motels, boarding houses with transient guests).
Group R-2 : Residential occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent (e.g., apartment houses, condominiums, nontransient boarding houses, dormitories).
Group R-3 : Residential occupancies where the occupants are primarily permanent and not classified under R-1, R-2, R-4, or I. This includes one- and two-family dwellings, small congregate living facilities (16 or fewer permanent occupants, or 10 or fewer transient occupants), and small care facilities caring for five or fewer occupants.
Group R-4 : Residential care/assisted living facilities housing between 6 and 16 occupants (excluding staff). Condition 1 applies to facilities where occupants are capable of self-preservation; Condition 2 applies where they require assistance.
9. Storage (Group S)
Group S is designated for buildings used for storage that are not classified as hazardous.
Group S-1 (Moderate-Hazard) : Storage of combustible materials (e.g., furniture, books, tires, cardboard packaging).
Group S-2 (Low-Hazard) : Storage of noncombustible materials, including those on wood pallets or in paper cartons (e.g., metal parts, empty bottles, cement bags, food products in noncombustible packaging).
10. Utility and Miscellaneous (Group U)
Group U covers towers, agricultural buildings, barns, carports, private garages, greenhouses, sheds, and retaining walls that do not fit into any other category.
Design Options for Mixed Occupancies (IBC Section 508)
Many modern buildings contain multiple uses, which requires the plan reviewer to apply the mixed occupancies rules of IBC Section 508. The code provides three main design options:
1. Accessory Occupancies (IBC Section 508.2)
An accessory occupancy is a space that is ancillary to the main occupancy. To qualify:
The accessory space must not occupy more than 10% of the building area of the story in which it is located.
The allowable height and area limits are based on the main occupancy group.
Fire Separation : No separation is required between the main occupancy and the accessory occupancy, except as specifically mandated by Table 508.2.1 (e.g., separating Group H accessory spaces or separating certain assembly areas).
2. Nonseparated Occupancies (IBC Section 508.3)
Under this option:
No fire-resistance-rated separations are required between the different occupancies.
The allowable building height and area must be determined based on the most restrictive occupancy present in the building or story.
Similarly, the fire protection system requirements (such as automatic sprinklers or fire alarms) are governed by the most restrictive occupancy. This option is popular for open layouts but can penalize the entire structure based on a minor, highly restrictive occupancy.
3. Separated Occupancies (IBC Section 508.4)
Under this option:
Each portion of the building must be separated from other occupancies by fire barriers and/or horizontal assemblies.
The minimum fire-resistance ratings for these separations are specified in IBC Table 508.4. These ratings vary from 1 to 4 hours depending on the occupancy groups being separated and whether the building is sprinklered.
The height and area of each separated occupancy must comply with its own classification, but the overall building must satisfy the "unity equation" (sum of the ratios of the actual area to the allowable area for each occupancy must not exceed 1.0). This method requires more structural and fire-rating analysis but maximizes the potential size of the building.