Study guide
1.1 Idaho Journeyman Exam Format, PSI Logistics & Rapid NEC Navigation
Idaho Journeyman Electrician Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Orientation, NEC Navigation & Idaho Regulations
1.1 Idaho Journeyman Exam Format, PSI Logistics & Rapid NEC Navigation 1.2 Idaho Electrical Licensing Laws (Title 54, Ch. 10) & IDAPA 24.39.10 Requirements 1.3 Idaho Permits, Inspection Procedures & State-Specific NEC Amendments 1.4 NEC Article 90 Scope, Code Arrangement & Article 110 General Requirements
2 Chapter 2: Electrical Theory & Essential Math Calculations
2.1 Ohm's Law, Joule's Law & DC Circuit Calculations 2.2 Single-Phase & Three-Phase AC Fundamentals and Power Factor 2.3 DC & AC Voltage Drop Calculations and Conductor Sizing 2.4 NEC Article 100 Essential Definitions for Journeymen
3 Chapter 3: Conductors, Raceways & Box Sizing Calculations
3.1 Conductor Ampacity, Insulation Types & Terminal Temperature Ratings 3.2 Ambient Temperature Correction & Raceway Conductor Bundling Derating 3.3 Outlet & Junction Box Volume Fill Calculations (NEC 314.16) 3.4 Conduit Fill Calculations & Large Pull Box Sizing (NEC 314.28)
4 Chapter 4: Branch Circuits & Overcurrent Protection
4.1 Branch Circuit Ratings, Multiwire Circuits & Receptacle Placement 4.2 GFCI & AFCI Protection Mandates and Idaho Code Clarifications 4.3 Overcurrent Protective Devices, Standard Ratings & Small Conductor Rules 4.4 Feeder & Transformer Tap Rules (NEC 240.21)
5 Chapter 5: Feeders, Services & Outside Branch Circuits
5.1 Feeder Conductor Sizing, Neutral Calculations & Voltage Drop 5.2 Outside Branch Circuits, Feeders & Overhead/Underground Clearances 5.3 Service Drop, Service Lateral & Service-Entrance Sizing 5.4 Service Disconnecting Means, Emergency Disconnects & Surge Protection
6 Chapter 6: Load Calculations: Dwellings & Commercial
6.1 General Lighting, Small Appliance & Laundry Load Calculations 6.2 Standard Method Single-Family Dwelling Service Calculations (NEC 220 Part III) 6.3 Optional Method Single-Family & Multifamily Calculations (NEC 220 Part IV) 6.4 Commercial & Industrial Feeder/Service Calculations
7 Chapter 7: Grounding and Bonding: Systems & Electrodes
7.1 Grounding vs. Bonding Fundamentals & System Grounding 7.2 Grounding Electrodes & Grounding Electrode Conductor (GEC) Sizing 7.3 Main Bonding Jumpers, System Bonding Jumpers & Supply-Side Bonding
8 Chapter 8: Grounding and Bonding: Equipment & Enclosures
8.1 Equipment Grounding Conductors (EGC) Types, Installation & Sizing (Table 250.122) 8.2 Separately Derived Systems (SDS) Transformers & Generator Grounding 8.3 Service Enclosure Bonding, Concentric Knockouts & Effective Ground-Fault Path
9 Chapter 9: Wiring Methods, Cables & Conduits
9.1 General Requirements for Wiring Methods & Underground Installations (Article 300) 9.2 Nonmetallic-Sheathed (NM), Metal-Clad (MC) & Armored (AC) Cables 9.3 Metallic & Nonmetallic Raceway Systems (EMT, PVC, RMC, FMC) 9.4 Cabinets, Cutout Boxes & Outlet Box Installation Rules (Articles 312 & 314)
10 Chapter 10: Equipment for General Use: Devices, Luminaires & Appliances
10.1 Switches, Receptacles & Device Installation Standards (Articles 404 & 406) 10.2 Luminaire Clearances, Closet Rules & Lighting Track (Article 410) 10.3 Household Appliances & Fixed Electric Space Heating (Articles 422 & 424) 10.4 Generators, Transformer Overcurrent Protection & Panelboards
11 Chapter 11: Motors, Motor Circuits & Controllers
11.1 Motor Nameplate vs. Table FLC & Branch Circuit Conductor Sizing 11.2 Branch Circuit Short-Circuit & Ground-Fault Protection (Table 430.52) 11.3 Motor Overload Protection Sizing & Selection (NEC 430 Part III) 11.4 Motor Disconnects, Controllers & Multimotor Feeder Calculations
12 Chapter 12: Special Occupancies & Hazardous Locations
12.1 Hazardous (Classified) Locations: Classes, Divisions, Zones & Seals 12.2 Commercial Garages, Repair Hangars & Fuel Dispensing Facilities 12.3 Health Care Facilities: Patient Care Spaces & Redundant Grounding (Article 517) 12.4 Agricultural Buildings, Marinas, Boatyards & RV Parks
13 Chapter 13: Special Equipment, Emergency Systems & Renewable Energy
13.1 Swimming Pools, Spas, Hot Tubs & Equipotential Bonding (Article 680) 13.2 Electric Vehicle Supply Equipment (EVSE) Installation & Sizing (Article 625) 13.3 Solar Photovoltaic (PV) Systems & Energy Storage Systems (Articles 690 & 706) 13.4 Emergency, Standby Power Systems & Fire Pumps (Articles 700, 701, 702 & 695) 13.5 Fire Alarm, Optical Fiber & Power-Limited Circuits (Articles 760, 770 & 800)
1.1 Idaho Journeyman Exam Format, PSI Logistics & Rapid NEC Navigation
Key Takeaways Explain This Topic AI
The Idaho Journeyman Electrician examination is 100 questions and requires 70% (70 correct) to pass; the Master exam requires 75%, and the Contractor and Limited Contractor exams require 70%.
DOPL publishes the journeyman item breakdown by NEC chapter: Introduction 7, Chapter 1 five, Chapter 2 twenty, Chapter 3 twenty, Chapter 4 fifteen, Chapter 5 thirteen, Chapter 6 seven, Chapter 7 five, Chapter 8 three, Chapter 9 three, and Calculations two.
The exam is open book on candidate-supplied references: the National Electrical Code (2023 edition, tested since August 1, 2025), Ferm’s Fast Finder Index, Ugly’s Electrical Reference, and Tom Henry’s Key Word Index — handbooks are not allowed.
You may highlight, tab, and leave permanent notes in your code book, but loose paper inside reference material is prohibited and will be confiscated.
A feedback button appears on every exam question; a challenge must cite a code article and the answer you believe is correct, and appeals are forfeited if you retake the exam first.
Last updated: August 2026
1.1 Idaho Journeyman Exam Format, PSI Logistics & Rapid NEC Navigation
The Idaho Journeyman Electrician Examination is the gateway to independent professional licensure in the State of Idaho. Administered on behalf of the Idaho Electrical Board within the Division of Occupational and Professional Licenses (DOPL) by PSI Services LLC , this high-stakes, open-book examination tests an electrician's ability to interpret, navigate, and apply the 2023 National Electrical Code (NFPA 70) alongside state-specific administrative statutes under Idaho Code Title 54, Chapter 10 and IDAPA 24.39.10 . Idaho routes candidates to register and pay directly through PSI at test-takers.psiexams.com/idcon/test after creating a DOPL Online Services account; the license application itself goes to DOPL after you pass.
Achieving a passing score requires far more than passive memorization. Success demands structured codebook architecture mastery, rapid keyword indexing workflows, disciplined time budgeting, and proven calculation methodologies.
1. Examination Blueprint & Administrative Logistics
The examination is conducted at PSI testing centers in computer-based testing (CBT) format. Candidates are tested across electrical theory, wiring methods, equipment for general use, grounding and bonding, calculations, special occupancies, and Idaho administrative rules. +-----------------------------------------------------------------------------+
- | IDAHO JOURNEYMAN EXAM SPECIFICATIONS |
- | |
- | [QUESTION COUNT] ---> 100 Questions (mostly four-option MCQ, |
- | plus some True/False items) |
- | [PASSING THRESHOLD] ---> 70% Minimum (70 Raw Correct Answers) |
- | [ADMINISTERING BODY] ---> PSI Services LLC (on behalf of Idaho DOPL) |
- | [FORMAT] ---> Open-Book, Computer-Based Testing (CBT) |
- | [EXAM FEE] ---> $75 paid to PSI at scheduling |
- | [TESTED CODE] ---> 2023 NEC (tested edition since 8/1/2025) |
- +-----------------------------------------------------------------------------+
- Key Examination Parameters
Exam Dimension Specification & Protocol
Total Item Count 100 items. DOPL states questions are four-option multiple choice with one correct answer, and that the exam also contains True/False questions.
Passing Standard 70% raw score (at least 70 correct out of 100). This is a straight percent-correct standard, not a scaled score. Master = 75%; Limited Installer and Contractor = 70%.
Allotted Time Published third-party figures for the Idaho journeyman exam range from 240 to 300 minutes, and DOPL’s own bulletin historically listed 4 hours. The PSI candidate bulletin for the exam you actually schedule is the controlling source — read it before test day. Plan around roughly 2.5 to 3 minutes per question.
Authorized Materials Candidate-supplied only: 2023 NFPA 70 (NEC), Ferm’s Fast Finder Index, Ugly’s Electrical Reference, Tom Henry’s Key Word Index. Handbooks are not allowed.
Hardware Allowed Silent, non-programmable basic or scientific calculator. Confirm device rules in the current PSI candidate bulletin.
Question Feedback A feedback button is available on every question; feedback must cite a code article and the answer you believe is correct.
Note
Official Reference Material Verification: Testing centers inspect candidate code books. DOPL’s bulletin is explicit that no other versions of the code book are allowed — no commentaries, no illustrated versions, and no handbooks. Idaho’s tested edition moved to the 2023 NEC effective August 1, 2025 , so the 2017 or 2020 editions will not match the citations, table numbers, and subsection structure used in the questions.
Warning
Do not expect to bring a printed copy of IDAPA 24.39.10 into the journeyman exam. DOPL’s approved-reference list for the Journeyman, Limited Installer, and Master exams contains only the NEC and the three commercial index/reference books above. The Idaho statutes and rules are still testable — you simply have to know them from memory rather than look them up. (The separate Contractor exam allows the DOPL Contractor’s Business and Law Reference Manual, which must be printed, hole-punched, and placed in a three-ring binder before exam day.)
1a. The Published DOPL Journeyman Exam Breakdown
DOPL publishes an actual item distribution for the journeyman exam, organized by NEC chapter. Because the exam is exactly 100 items, each item count is also a percentage — use this table to allocate study time.
Exam Block Items What It Covers
Introduction 7 NEC Article 90 (purpose, scope, code arrangement) plus Idaho Code Title 54 Chapter 10 and IDAPA 24.39.10
NEC Chapter 1 5 Article 100 definitions; Article 110 general requirements, terminations, working space
NEC Chapter 2 20 Branch circuits (210), calculations (220), feeders (215), services (230), overcurrent (240), grounding and bonding (250)
NEC Chapter 3 20 Wiring methods (300), ampacity (310), boxes (312/314), cables (320/330/334), raceways (342/344/348/352/358)
NEC Chapter 4 15 Switches (404), receptacles (406), panelboards (408), luminaires (410), appliances (422), heating (424), motors (430), generators (445), transformers (450)
NEC Chapter 5 13 Hazardous locations (500-506), garages (511), fuel dispensing (514), health care (517), agriculture (547), marinas (555), RV parks (551)
NEC Chapter 6 7 Signs (600), EVSE (625), pools and spas (680), solar PV (690), energy storage (706), fire pumps (695)
NEC Chapter 7 5 Emergency (700), legally required standby (701), optional standby (702), interconnection (705), Class 1/2/3 (725), fire alarm (760)
- NEC Chapter 8 3 Communications systems (800-840), which are independent of Chapters 1-7
- NEC Chapter 9 3 Tables 1, 4, 5, and 8 — conduit fill, raceway area, conductor area, conductor properties
- Calculations 2 Stand-alone calculation items
- TOTAL 100
Important
Where the points actually are. Chapters 2 and 3 together are 40 of 100 items — more than the Introduction, Chapter 1, Chapters 6 through 9, and Calculations combined. If your study time is limited, branch circuits, load calculations, services, grounding and bonding, ampacity, boxes, and raceways are where it pays off.
2. Permitted Codebook Tabs, Highlighting & Calculator Guidelines
PSI maintains rigorous rules regarding authorized testing materials. Proctors will examine your reference codebook thoroughly before allowing you into the testing carrel. +-----------------------------------------------------------------------------+
- | PSI REFERENCE MATERIAL AUDIT |
- | |
- | [PERMITTED - DOPL APPROVED REFERENCE LIST] |
- | * 2023 National Electrical Code (NFPA 70), candidate-supplied |
- | * Ferm's Fast Finder Index (IAEI) |
- | * Ugly's Electrical Reference (George V. Hart) |
- | * Tom Henry's Key Word Index |
- | * Permanent tabs, highlighting, and handwritten notes in those books |
- | |
- | [PROHIBITED - GROUNDS FOR CONFISCATION / DISQUALIFICATION] |
- | * NEC HANDBOOKS, commentaries, and illustrated code editions |
- | * Other editions of the code book (2017 / 2020 NEC) |
- | * Loose paper inside reference material; sticky Post-it notes |
- | * Smartphones, smartwatches, recording devices, or digital assistants |
- +-----------------------------------------------------------------------------+
- Marking Up Your Books
DOPL's rule is short and worth quoting: you may highlight your book, tab different sections, and leave notes in your reference material , but loose paper in your reference material will not be allowed . That is a genuinely permissive marking policy compared with many states — build your index, write your formulas in the margins, and tab every table in the "Power Tables" checklist below.
Calculators
Bring a silent, non-programmable, battery- or solar-powered basic four-function or scientific calculator. Devices with QWERTY keyboards, wireless connectivity, stored programs, or text memory are not acceptable at PSI test centers. PSI does not publish an approved-model list for this program, so verify the device rules in the candidate bulletin for the exam you schedule rather than assuming a particular model is allowed.
If You Think a Question Is Wrong
DOPL provides a formal challenge path, and knowing it is worth points of peace of mind:
Use the feedback button available on every question during the exam . Feedback must reference an article in the code book and state the answer you believe is correct; feedback that does not meet that standard is not reviewed.
If you did not leave feedback during the exam, submit a Comment/Challenge form to DOPL within 15 days of completing the exam.
Allow 15 days for a response on a failed exam; if a score change is merited you are notified by email.
Critical: if you retake a failed exam on which you submitted an appeal or left feedback, you forfeit the appeal for that attempt. Wait for the ruling before rescheduling.
3. Exam Time Management: The 3-Pass Method
Whatever the exact allotted time turns out to be on your bulletin, budget it as percentages of the clock rather than fixed minute marks . Questions vary drastically in complexity — from a 30-second definition lookup to a 6-minute multi-step motor feeder calculation. The 3-Pass Method ensures you capture all easy points before committing time to arduous calculations. +-----------------------------------------------------------------------------+
- | THE 3-PASS EXAM TIME BUDGET (% OF CLOCK) |
- | |
- | [PASS 1: RAPID LOOKUPS & THEORY] (first ~35% of the clock) |
- | * 40-50 Questions | Target: 45-90 seconds per question |
- | * Direct index lookups, definitions (Art. 100), basic clearance tables |
- | * Read question: If solvable immediately or found in 1 min, ANSWER. |
- | * If complex math or multi-table cross-reference: SELECT GUESS, FLAG & SKIP|
- | |
- | [PASS 2: MODERATE LOOKUPS & SINGLE-STEP MATH] (next ~40% of the clock) |
- | * 35-40 Flagged Questions | Target: 2.5 - 3.5 minutes per question |
- | * Conductor ampacity derating (Art. 310), box fill calculations (Art. 314)|
- | * Standard motor branch circuits (Art. 430), Table 250.66 / 250.122 |
- | * Grounding electrode sizing, simple voltage drop |
- | |
- | [PASS 3: MULTI-STEP CALCULATIONS & DEEP RESEARCH] (next ~20%) |
- | * 10-15 Heavy Questions | Target: 4.0 - 6.0 minutes per question |
- | * Full dwelling unit service load calculations (Art. 220) |
- | * Multi-motor feeder OCPD sizing & complex conduit fill |
- | * Idaho administrative code rules recalled from memory (no IDAPA book!) |
- | |
- | [PASS 4: FINAL AUDIT & SUBMIT] (final ~5%) |
- | * Verify ZERO unanswered questions (ensure all 100 have an answer logged) |
- | * Re-verify calculations for simple arithmetic errors |
- +-----------------------------------------------------------------------------+
Tip
Never Leave a Question Blank: The PSI examination does not impose a negative guessing penalty. A blank question is guaranteed 0 points, whereas an educated guess provides a 25% to 50% probability of being correct. Always log a placeholder answer immediately when flagging a question for later review.
4. Rapid NEC Navigation Architecture & Keyword Strategies
Navigating the 900+ pages of the 2023 NEC under timed conditions requires mastering the codebook's organizational framework. The Code is structured logically from general principles to specialized installations. +-----------------------------------------------------------------------------+
- | 2023 NEC CODE ARRANGEMENT (90.3) |
- | |
- | CHAPTERS 1, 2, 3, 4 ---> GENERAL REQUIREMENTS (Apply Universally) |
- | - Ch. 1: General (Definitions, Requirements for Installations) |
- | - Ch. 2: Wiring & Protection (Branch Circuits, Feeders, Services, G&B) |
- | - Ch. 3: Wiring Methods & Materials (Conductors, Conduits, Boxes, Cables) |
- | - Ch. 4: Equipment for General Use (Cords, Switches, Panels, Motors) |
- | | |
- | v |
- | CHAPTERS 5, 6, 7 ---> SPECIAL OCCUPANCIES, EQUIPMENT & CONDITIONS |
- | - Ch. 5: Special Occupancies (Hazardous Locations, Garages, Healthcare) |
- | - Ch. 6: Special Equipment (Signs, Cranes, Pools, Solar PV, EVSE) |
- | - Ch. 7: Special Conditions (Emergency Systems, Optical Fibers, Class 1/2)|
- | (These chapters SUPPLEMENT or MODIFY the general rules in Chapters 1-4) |
- | | |
- | v |
- | CHAPTER 8 ---> COMMUNICATIONS SYSTEMS (Completely Independent) |
- | - Ch. 8: Standalone rules; Chapters 1-7 do NOT apply unless referenced |
- | | |
- | v |
- | CHAPTER 9 ---> TABLES (Conduit Dimensions, Wire Fill, Resistance)|
- | ANNEXES A - K ---> INFORMATIVE (Non-mandatory engineering guidance)|
- +-----------------------------------------------------------------------------+
- The Keyword Identification Process
When reading an exam question, you must instantly filter out conversational filler and extract the operative technical noun . +-----------------------------------------------------------------------------+
- | KEYWORD EXTRACTION WORKFLOW |
- | |
- | QUESTION: "What is the minimum clear working space depth required in |
- | front of a 480V switchboard facing an exposed concrete wall?" |
- | |
- | [STEP 1: FILTER NOISE] ---> Strip words like "What is", "minimum", |
- | "required", "facing". |
- | [STEP 2: IDENTIFY NOUNS]---> "Working space", "Switchboard", "480V", |
- | "Concrete wall". |
- | [STEP 3: CHOOSE KEY] ---> Primary: "Working space" (Table of Contents |
- | or Index) -> Direct to NEC 110.26(A)(1). |
- | [STEP 4: SUB-HEADING] ---> Locate Table 110.26(A)(1) Condition 2 (0-600V)|
- +-----------------------------------------------------------------------------+
- Effective vs. Ineffective Keyword Search Terms
- Poor Search Term (Too Generic / Misleading) Optimal Search Term (Precise NEC Noun) Primary NEC Target Article
- "Wire" or "Cable" Ampacity / Conductors for General Wiring Article 310 / Table 310.16
- "Breaker" or "Fuse" Overcurrent Protection / Standard Ampere Ratings Article 240 / 240.6(A)
- "Ground wire" Grounding Electrode Conductor or Equipment Grounding Conductor Table 250.66 or Table 250.122
- "Electric Car Charger" Electric Vehicle Power Transfer System (EVSE) Article 625
- "Hot Tub" or "Jacuzzi" Spas and Hot Tubs / Swimming Pools Article 680, Part IV
- "Romex" Nonmetallic-Sheathed Cable (Type NM) Article 334
- "Panelboard clearance" Spaces About Electrical Equipment Article 110.26
- 5. Master "Power Tables" Navigation Checklist
Approximately 40% of all journeyman exam questions require reading data directly from key tables in the 2023 NEC. Memorizing the location and purpose of these Power Tables saves vital minutes.
Table Reference Table Name / Primary Function High-Yield Application on Exam
Table 110.26(A)(1) Working Spaces (Conditions 1, 2, 3) Depth of clear space in front of panels based on voltage and wall material
Table 250.66 Grounding Electrode Conductor for AC Systems Sizing GEC based on size of largest ungrounded service-entrance conductor
Table 250.102(C)(1) Grounded Conductor, Main Bonding Jumper, Supply-Side Jumper Sizing supply-side bonding jumpers, system bonding jumpers, and main bonding jumpers
Table 250.122 Minimum Size Equipment Grounding Conductors (EGC) Sizing copper or aluminum EGC based on rating of upstream overcurrent device
Table 310.16 Conductor Ampacities (Not More than 3 Current-Carrying in Raceway) Baseline ampacity lookup for copper and aluminum conductors at 60°C, 75°C, 90°C
Table 310.15(B)(1) Ambient Temperature Correction Factors (Based on 30°C) Multiplying factor for raceways/cables in elevated ambient temperatures
Table 310.15(C)(1) More Than Three Current-Carrying Conductors Adjustment Factors Derating factors (80%, 70%, 50%, etc.) when 4 or more conductors share raceway
Table 314.16(A) Metal Boxes (Volume Capacity) Maximum number of conductors permitted in standard trade-size metal boxes
Table 314.16(B) Volume Allowance Required per Conductor Volume allowances (in³ / cm³) per AWG conductor for box fill calculations
Table 430.52 Maximum Rating of Motor Branch-Circuit Protection Devices Sizing non-time delay fuses, dual-element fuses, and inverse-time circuit breakers
Table 430.248 Full-Load Current in Amperes, Single-Phase AC Motors Standard full-load currents (FLC) for 115V, 208V, 230V single-phase motors
Table 430.250 Full-Load Current in Amperes, Three-Phase AC Motors Standard full-load currents (FLC) for 208V, 230V, 460V, 575V 3-phase motors
Chapter 9, Table 1 Percent of Cross Section of Conduit and Tubing for Conductors Conductor fill percentages (1 wire = 53%, 2 wires = 31%, 3+ wires = 40%)
Chapter 9, Table 4 Dimensions and Percent Area of Conduit and Tubing Internal cross-sectional area (in² / mm²) for EMT, PVC, RMC, FMC at 40% fill
Chapter 9, Table 5 Dimensions of Insulated Conductors and Fixture Wires Approximate cross-sectional area (in² / mm²) for THHN, THWN-2, XHHW, USE conductors
Chapter 9, Table 8 Conductor Properties DC resistance (ohms/kFT) and circular mil area for copper and aluminum
Important
Table of Contents vs. Index Search Protocol:
Use the Table of Contents when you know the general article category (e.g., you know motors are in Article 430, or transformers are in Article 450).
Use the Subject Index when the topic is narrow, obscure, or spans multiple articles (e.g., "Swimming Pools, Equipotential Bonding" or "Temporary Wiring" ).
If the Index fails to list a term under your initial search noun, immediately pivot to a broader synonym rather than scanning line-by-line.