Study guide
17.1 Equipment Maintenance, Calibration Schedules & Clinic Safety
IJCAHPO Certified Retina Technician CRT
Track your progress as you read
Finished sections get a check mark.
1 Exam Overview: Current CRT Requirements & Blueprint
Exam Overview: Current Requirements, Scope & Study Plan
2 Chapter 1: History Taking, Triage & Clinical Documentation
1.1 Comprehensive Ophthalmic & Medical History for Retina Patients 1.2 Telephone Triage, Urgent Symptoms & Emergency Scheduling 1.3 Scribing, Electronic Health Records & Retinal Billing Codes
3 Chapter 2: Visual Assessment & Low Vision Rehabilitation
2.1 Standardized Visual Acuity Testing & Optotypes 2.2 Sub-Chart Acuity Protocols: CF, HM, LP, and NLP 2.3 Low Vision Definitions, Optical Devices & Patient Counseling
4 Chapter 3: Pupil Assessment & Visual Field Testing
3.1 Pupillary Examination & Relative Afferent Pupillary Defect 3.2 Confrontation Fields & Automated Perimetry in Retina 3.3 Amsler Grid Testing & Metamorphopsia Monitoring
5 Chapter 4: Tonometry & Ocular Motility
4.1 Goldmann Applanation & Handheld Tonometry Techniques 4.2 Tonometer Disinfection, Calibration & Post-Procedure IOP Monitoring 4.3 Ocular Motility Assessment, Strabismus & Alignment Testing
6 Chapter 5: Diagnostic Ophthalmic Ultrasound
5.1 Ophthalmic B-Scan Echography for Posterior Segment Pathology 5.2 Standardized A-Scan Echography & Optical Biometry
7 Chapter 6: Slit Lamp, Electrophysiology & Supplemental Testing
6.1 Slit Lamp Biomicroscopy, Illumination & Fundus Lenses 6.2 Color Vision Assessment & Hertel Exophthalmometry 6.3 Ophthalmic Electrophysiology: ERG, VEP, and EOG
8 Chapter 7: Ophthalmic Microbiology & Infection Control
7.1 Ocular Pathogens & Routes of Disease Transmission 7.2 Clinical Asepsis, Universal Precautions & Vitreous Specimen Collection
9 Chapter 8: General Retinal Pharmacology & Therapeutics
8.1 Ocular Drug Delivery Methods & Routes of Administration 8.2 Mydriatics, Cycloplegics & Diagnostic Ophthalmic Dyes 8.3 Anesthetics, Glaucoma Agents & Prescription Verification
10 Chapter 9: Anti-VEGF Therapies, Steroids & Retinal Toxicity
9.1 Anti-VEGF Agents & Neovascular Retinal Diseases 9.2 Corticosteroids, Sustained-Release Implants & AREDS Supplements 9.3 Systemic Medication Retinal Toxicity & Plaquenil Screening
11 Chapter 10: Surgical Assisting & Intravitreal Procedures
10.1 Intravitreal Injection Protocol, Antisepsis & Complication Checks 10.2 Retinal Laser Therapy Modalities & Laser Safety Protocols 10.3 Surgical Instrument Handling, Tray Setup & Sterilization
12 Chapter 11: Patient Services, Education & Clinical Care
11.1 Patient Education, Chronic Disease Counseling & Treatment Adherence 11.2 Special Needs Accommodations, Patient Diversity & Interpersonal Skills 11.3 Ophthalmic Emergencies, First Aid & Clinical Care Coordination 11.4 Clinic Operations, Research Support, Forms & Referrals
13 Chapter 12: General Ocular Anatomy & Retinal Physiology
12.1 Ocular Anatomy, Orbit & Posterior Segment Architecture 12.2 Ten Retinal Layers, Photoreceptors & Macular Anatomy 12.3 Ocular Blood Supply, Microcirculation & Vitreoretinal Interface 12.4 Body Systems, Ocular Adnexa & Medical Terminology
14 Chapter 13: Retinal Pathology & Systemic Disease Manifestations
13.1 Age-Related Macular Degeneration & Retinal Vascular Occlusions 13.2 Diabetic Retinopathy & Systemic Diseases Affecting the Retina 13.3 Peripheral Retinal Degenerations, Tears & Detachments
15 Chapter 14: Ophthalmic Optics & Lensometry
14.1 Principles of Ophthalmic Optics & Refraction 14.2 Manual & Automated Lensometry Techniques
16 Chapter 15: Fundus Photography & Ophthalmic Angiography
15.1 Fundus Photography Techniques & Fundus Autofluorescence 15.2 Fluorescein Angiography Principles, Phases & Image Interpretation 15.3 Indocyanine Green Angiography & Angiographic Complication Management
17 Chapter 16: Optical Coherence Tomography (OCT & OCT-A)
16.1 OCT Principles, Scan Acquisition & Artifact Recognition 16.2 Structural OCT Interpretation: Retinal Fluid & Biomarkers 16.3 Optical Coherence Tomography Angiography (OCT-A) Principles & Flow
18 Chapter 17: Equipment Maintenance, Ethics & Regulatory Compliance
17.1 Equipment Maintenance, Calibration Schedules & Clinic Safety 17.2 Medical Ethics, Scope of Practice & Informed Consent 17.3 Patient Privacy, HIPAA Standards & Hazardous Waste Disposal
17.1 Equipment Maintenance, Calibration Schedules & Clinic Safety
Key Takeaways Explain This Topic AI
Use the current manufacturer instructions and facility preventive-maintenance plan for each device; schedules, cleaning agents, calibration targets, and authorized repairs are not universal.
Before use, inspect power, battery charge, cords, plugs, optics, guards, moving parts, accessories, and required self-test status; tag and remove unsafe equipment from service.
For a Haag-Streit AT 900, monthly Goldmann calibration verification uses drum positions 0, 2, and 6 with model-specific ranges, not one ±0.5 mmHg limit at every point.
Clean coated lenses, prisms, cameras, OCT optics, and housings only with manufacturer-approved materials and technique; abrasive tissue, excess fluid, or an unapproved solvent can damage them.
Emergency equipment, eyewash, medication storage, supplies, and backup power require documented checks under the applicable policy, label, and regulatory plan.
Last updated: September 2026
Equipment Maintenance, Calibration & Clinic Safety
Reliable measurements depend on equipment identity, condition, approved cleaning, calibration, software configuration, and staff competency. Build the maintenance plan from the device's current instructions for use, facility policy, clinical-engineering schedule, and applicable regulation. A schedule copied from another model is not evidence.
Pre-use and routine checks
Before use, confirm the correct device and accessories. Inspect housing, power cord, plug, footswitch, battery indicator, charger, cables, connectors, wheels, locks, chin rest, forehead strap, guards, optics, and disposables. Run the manufacturer-required self-test. Verify date and time when they affect image comparison. Check that emergency stop controls and isolation features are accessible.
Handheld instruments need charged batteries, clean contacts, undamaged housings, and a backup plan. Rechargeable cells are replaced according to performance and the manufacturer's limits, not an invented calendar. Remove leaking, swollen, overheating, or damaged batteries from use and follow the approved disposal process.
If a device is dropped, exposed to liquid, produces smoke or unusual heat, fails self-test, gives implausible values, or has a damaged patient-contact surface, stop using it. Attach an out-of-service label, prevent accidental reuse, document the event, and notify the designated service group. Only authorized personnel open housings or perform repairs.
Optical surfaces and patient-contact parts
Dust is removed with the approved noncontact method before wiping. Use only specified lens paper, cloth, fluid, and motion for coated fundus lenses, camera objectives, OCT apertures, slit-lamp optics, and prisms. Apply fluid to the approved wipe rather than flooding the instrument unless the instructions say otherwise. Separate optical cleaning from high-level disinfection of a patient-contact surface.
Inspect lenses and prisms for chips, coating damage, cracks, deposits, and clouding. Clean chin rests, forehead straps, handles, fixation targets, and controls using compatible products and required wet-contact time. A disinfectant can be microbiologically effective yet mechanically destructive to a particular device.
Calibration and quality control
Record device identifier, date, test method, reference device or phantom, expected range, observed result, staff member, and corrective action.
For the Haag-Streit AT 900, the monthly check uses its test weight at measuring-drum positions 0, 2, and 6. The current instructions specify −0.05 to +0.05 at zero, 1.95 to 2.05 at position 2, and 5.9 to 6.1 at position 6. Another model may use different tools or limits. A failed device is removed from service; staff do not apply informal correction factors to patient results.
Automated perimeters, fundus cameras, ultrasound systems, OCT/OCT-A platforms, lasers, and cryotherapy units use manufacturer-defined self-tests, reference targets, service intervals, and environmental limits. Quality control includes recognizing drift in image scale, focus, illumination, segmentation, fixation monitoring, probe performance, output verification, or system warnings. Escalate rather than bypass a warning.
Emergency and environmental readiness
Check emergency eyewash, crash cart, oxygen, suction, AED, spill kits, and emergency medications at the frequency assigned by the facility plan. Record seal status, expiration, battery readiness, accessibility, and inspection result. Test an eyewash according to the governing safety program and keep access unobstructed.
Monitor storage temperature for medications and supplies according to each product label. Review minimum and maximum logs and respond to an excursion through the designated quarantine and pharmacy process; do not return a product to use based on appearance alone. Product-specific labels control refrigeration, freezing protection, light protection, and allowable room-temperature exposure.
Use first-expire-first-out inventory rotation, retain lot and expiration traceability when required, and keep sufficient emergency and procedure supplies without overstocking. Clinical readiness includes charged equipment, compatible disposables, updated software under change control, accessible instructions, trained users, and a documented backup workflow.
Service records
Keep maintenance, calibration, repair, software, recall, and incident records with the device. After repair, verify return-to-service authorization and required performance tests. Report recurring failures and possible adverse device events through the organization's safety and regulatory process.
Recall, software, and downtime control
Device safety includes software version, cybersecurity notices, accessories, and recalls. Match the model and serial number to a recall or field-correction notice, quarantine affected equipment when instructed, and document the manufacturer's remedy. Software updates require change control and post-update function checks; never install an unapproved update during patient care.
Every critical system needs a downtime plan. Staff should know how to preserve images, label laterality, document results, contact service, and move patients when the network, PACS, power, or device is unavailable. After repair, authorized personnel complete required performance verification before return to service. Trends such as repeated self-test failure, drifting measurements, intermittent cables, or recurring artifacts are reported even when a reboot temporarily clears the symptom.