Study guide

15.1 Electricity and Facial Machines

Illinois Esthetician License IDFPR / CTS-PSI Theory Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Illinois Exam Overview

1.1 Current Illinois Esthetician Exam Facts 1.2 Eligibility and the 750-Hour Illinois Curriculum 1.3 Application, Scheduling, Retakes, and Licensure

2 Illinois Law, Scope & Licensing

2.1 IDFPR, the BCENT Board, and the Act 2.2 Scope of Practice and Prohibited Practices 2.3 Renewal, Continuing Education, Fees, and Restoration

3 Illinois Sanitary Standards, Salon Registration & Labor Law

3.1 Illinois Sanitary Standards (68 Ill. Adm. Code 1175.115) 3.2 Salon/Shop Registration and Facility Requirements 3.3 Labor, Compensation, OSHA, and Professional Conduct

4 Microbiology & Infection Control

4.1 Microbiology: Bacteria, Viruses, Parasites, and Fungi 4.2 Levels of Infection Control 4.3 Methods of Infection Control: Heat and Chemical Agents

5 Safety, Blood Exposure & Chemical Handling

5.1 Standard (Universal) Precautions 5.2 Blood Exposure Procedures 5.3 Safety Data Sheets, Chemical Handling, and OSHA

6 Human Anatomy & Physiology

6.1 Cells, Tissues, and Metabolism 6.2 Organs and Body Systems for Estheticians 6.3 Nutrition and Health of the Skin

7 Skin Histology & Physiology

7.1 Epidermal Layers and Structure 7.2 Dermis, Hypodermis, and Glands 7.3 Functions of the Skin

8 Lesions, Gland Disorders, Contagious Conditions

8.1 Primary and Secondary Skin Lesions 8.2 Disorders of the Sebaceous and Sudoriferous Glands 8.3 Contagious Diseases and Inflammations

9 Pigmentation, Growths, Cancers & Referral

9.1 Pigmentation Disorders 9.2 Skin Growths and Cancers 9.3 Contraindications and When to Refer

10 Hair Structure, Growth & Abnormal Growth

10.1 Hair Structure and the Follicle 10.2 Hair Growth Cycles 10.3 Abnormal Hair Growth: Hirsutism and Hypertrichosis

11 Chemistry, pH & Product Knowledge

11.1 pH, Acids, and Alkalinity 11.2 Ingredients and Product Function 11.3 Labeling, SDS, and Chemical Service Procedures

12 Consultation, Draping, Skin Analysis & Protocols

12.1 Client Consultation, Documentation, and Draping 12.2 Skin Types, Fitzpatrick Typing, and Analysis 12.3 Treatment Protocol and Service Contraindications

13 Facial Procedures, Massage, Extractions & Masks

13.1 Facial Sequence: Cleansing and Steaming 13.2 Facial Massage Manipulations 13.3 Extractions and Mask Therapy

14 Exfoliation, Finishing, SPF & Home Care

14.1 Chemical and Mechanical Exfoliation 14.2 Finishing: Moisturize, Sun Protection, and Home Care 14.3 Aftercare and Adverse Reactions

15 Electricity, Machines & Illinois Advanced Boundaries

15.1 Electricity and Facial Machines 15.2 Microdermabrasion, Dermaplaning, and Nano Infusion 15.3 Illinois Advanced Boundaries: Medspas and Lasers

16 Hair Removal, Body Treatments & Wellness

16.1 Waxing, Tweezing, and Depilatories 16.2 Hair Removal Contraindications and Safety 16.3 Body Treatments, Wraps, Wellness, and Aromatherapy

17 Makeup, Color Theory, Lashes & Brows

17.1 Color Theory and Makeup Application 17.2 Makeup Safety, Bracing, and Infection Control 17.3 Eyelash and Eyebrow Services

15.1 Electricity and Facial Machines

Key Takeaways Explain This Topic AI

The outline tests safe use of skin care tools, machines, and devices (Skin Care) and electrical safety (Safety and Infection Control). Illinois 1175.835 places electricity, machines and apparatus, and facial treatments with the aid of machines in the 500-hour Practices block; 1175.805 requires a steamer, magnifying lamp, and Woods lamp at every workstation.

Direct current (galvanic) flows in one direction; alternating current (high-frequency Tesla) reverses. Amp is strength, volt is pressure, ohm is resistance, watt is power; facial currents are measured in milliamperes.

Galvanic negative pole (cathode) is alkaline anaphoresis/desincrustation; positive pole (anode) is acidic cataphoresis/iontophoresis. High-frequency direct method is germicidal on the skin; indirect is stimulating; sparking is used after extraction.

Do not apply galvanic, high-frequency, or other electrical modalities to a client with a pacemaker, metal implants, epilepsy, or (for many currents) pregnancy. Screen before you plug the machine in.

68 Ill. Adm. Code 1175.115 requires cleaning and disinfecting every machine part that contacts the client. Subsection (d) adds registration, safety, FDA documentation if the device is classified, and use only within scope and the manufacturer’s intended use.

Last updated: October 2026

The 2026 outline lists safe use of skin care tools, machines, and devices under Skin Care and electrical safety under Safety and Infection Control. Illinois writes the same skill into the 750-hour program. 68 Ill. Adm. Code 1175.835(a)(3) lists electricity, machines and apparatus and facial treatments with the aid of machines next to facial treatments without the aid of machines in the 500-hour Practices and Procedures block. 1175.805(a)(4) then tells you what a school workstation must actually hold: a facial chair , a steamer , a magnification lamp , and a Woods lamp , plus a shared set that includes brushing , a vacuum/spray machine , glass electrode or high-frequency current , and a disencrustation machine (galvanic). The exam is not asking you to repair a circuit board. It is asking you to name the current, pick the machine, screen the contraindication, and disinfect what touched the client.

Illinois 1175.115(d) is the legal overlay on every plug. A machine used in esthetics must meet product registration and product safety requirements of any federal, State, county, or local authority. If the device is classified by the Food and Drug Administration (FDA) , you must verify, maintain, or be able to access the documentation. You may not use the device unless the use is part of services within your scope , is consistent with the manufacturer’s intended use , and is consistent with client health and safety . A steamer used as labeled is in bounds. A radio-frequency handpiece marketed to heat living dermis is not saved because it sits on the same rolling cart.

Conductors, insulators, and a complete circuit

Electricity is the movement of electrons along a path. That path is a circuit . Current does not flow until the circuit is complete (closed). Break the path — unplug the electrode, lift the wand, trip a breaker — and the modality stops. That is why a loose inactive electrode in galvanic work, or a client who lets go of the handheld electrode, is not a small inconvenience. The circuit is open.

A conductor lets electrons move. Exam-typical conductors are metals , carbon , water , and the human body . That last one is why electrical modalities work on skin and why wet hands on a damaged cord are a shock risk. An insulator resists flow. Exam-typical insulators are rubber , silk , wood , glass , cement , and plastic . The rubber on a cord and the plastic housing on a steamer are not decoration. They are the barrier between the client and a conductor.

Direct current (DC) is a constant, even-flowing current traveling in one direction . Batteries produce DC. Galvanic current is DC. Alternating current (AC) is a rapid, interrupted current that reverses direction . Wall outlets supply AC. Tesla high-frequency is an oscillating alternating current. If a stem asks which facial current is direct, the answer is galvanic . If it asks which is alternating, the answer is high-frequency .

The four units you must match

Unit What it measures Esthetics hook

Ampere (amp) Strength of the current (number of electrons) Facial currents are tiny; you work in milliamperes (1/1,000 of an amp)

Volt Pressure or force that pushes the current Wall current is higher voltage than a battery-powered galvanic unit

Ohm Resistance Dry skin, thick corneum, and poor contact raise resistance; wet skin lowers it

Watt Power (volts × amps) How much energy the device uses; a 100-watt magnifying bulb is a teaching example, not a statute

Ohm’s-law thinking is enough: more voltage through the same resistance means more current; more resistance (dry, thick, poorly contacted skin) means less current for the same setting. Do not crank a galvanic milliammeter because the client “doesn’t feel it yet.” Check contact, moisture, and whether the inactive electrode is in the hand.

Grounding and GFCI

Grounding gives stray current a safe path to the earth instead of through the client or the operator. A three-prong plug is the exam picture: two blades carry the circuit; the round pin is the ground. Do not break off the ground pin to fit a two-hole outlet. 1175.115(e) already requires compliance with electrical as well as plumbing, fire, and building codes.

A ground-fault circuit interrupter (GFCI) is an outlet or breaker that trips when it detects current leaking from the intended path — typical of a wet room with a steamer, spray machine, and wet hands. Plug facial machines into a GFCI-protected circuit in wet areas. If a machine sparks at the plug, overheats, or has a cracked housing, take it out of service. 1175.115(b)(25) requires equipment to be kept clean and in good repair . A frayed cord is not “good repair.”

Analysis lamps: magnifying and Woods

The magnifying lamp (loupe) is the analysis light. Typical teaching strength is about 5 diopters . Use it after cleanse, with the client draped, to look at texture, comedones, capillaries, and lesions you will not diagnose. Do not park the hot bulb on the client’s face. Disinfect the contact surfaces of the arm and handle; the lens is wiped as the manufacturer allows.

The Woods lamp is a filtered black light used in a darkened room after cleanse. It is an analysis aid, not a diagnosis. Exam-typical color teaching:

  • Blue-white — relatively healthy/normal surface
  • Purple or violet — dehydration
  • White fluorescence — thick stratum corneum / horny buildup
  • Yellow, pink, or orange — oil, comedones
  • Brown — pigmentation / sun damage

A Woods lamp does not let you name melanoma. 225 ILCS 410/3A-1 still forbids medical-treatment advice. If you see an irregular pigmented lesion, you refer . You do not treat it with galvanic current because it “looked brown under the lamp.”

Steamer, vacuum/spray, brushing, and the Lucas sprayer

The facial steamer softens sebum and corneum with warm vapor so extraction and product work are easier. Use distilled water unless the manufacturer specifies otherwise; tap minerals scale the heating element. Keep the nozzle at a textbook teaching distance of about 15–18 inches — close enough to warm, not close enough to scald or drip condensate onto the eye. Typical steam time is about 5–10 minutes , adjusted to skin. Do not steam rosacea/couperose, highly sensitive or sunburned skin, respiratory congestion the client cannot tolerate, or skin you may not massage under 1175.115 (inflamed, infected, or erupting). Optional ozone on some steamers is a surface germicidal add-on, not a medical wound treatment.

The vacuum/spray machine has two jobs. Vacuum (suction) helps lift debris from follicles after softening; it is not a substitute for proper extraction technique and is contraindicated on couperose, inflamed acne, and fragile skin. Spray atomizes toner or astringent. Cups and bottles that contact product or skin are cleaned and disinfected or are single-use .

The brushing machine uses rotating brushes for mechanical cleansing/exfoliation of resilient skin. It is not for acne, rosacea, sunburn, or thin skin. Brushes that contact the client are cleaned, then disinfected if nonporous and reusable; porous brush heads that cannot be disinfected are discarded ( 1175.115(b)(3), (b)(11) ).

The Lucas sprayer (Lucas Championnière atomizer) is a cool, fine mist used to apply product — often hydrators or diluted essential-oil blends at the end of a facial. It is a delivery tool, not an inhalational medical treatment. See Section 15.3 for aromatherapy claims.

Galvanic: anaphoresis and cataphoresis

Galvanic current is DC . Two electrodes complete the circuit: the active electrode produces the effect you want (usually on the face); the inactive electrode is typically held in the client’s hand or placed on a large, padded contact. Water-soluble products can be driven by polarity. Oil-only products do not ionize well.

Pole Charge Chemical effect Process name Esthetics use

Cathode (negative) Alkaline Softens, saponifies sebum, opens Anaphoresis / desincrustation Pre-extraction on oily/congested skin

Anode (positive) Acidic Calms, firms, closes Cataphoresis / iontophoresis After extraction or to infuse water-soluble acidic products

Memorize the pairing, not a brand protocol. Desincrustation is the alkaline negative-pole step. Iontophoresis is the general term for driving ions; on the exam it is often the positive pole calming the skin. Do not reverse poles because a classmate “always starts positive.” Follow the machine’s labeled polarity and the product’s intended pole.

High-frequency: direct, indirect, sparking

High-frequency (Tesla) is alternating , oscillating current. A glass electrode (often argon/violet for oily/acne teaching or neon/orange for dry/mature teaching) ionizes oxygen into ozone with a germicidal effect when used on the skin.

Direct method: the electrode contacts the skin (sometimes over dry gauze). This is the germicidal method used on congested or acne-prone surface skin.

Indirect method: the client holds the electrode and the esthetician massages. This is warming and stimulating, not the primary germicidal application.

Sparking: after extraction, lift the electrode slightly so a small spark treats the open follicle. This is a surface germicidal step, not electrosurgery.

Keep high-frequency away from flammable products (alcohol, some solvents). Do not use it to “cauterize” living tissue. That intent is medicine.

Ultrasonic spatula as a surface tool

Textbooks list ultrasonic among other facial services. The exam-typical ultrasonic spatula vibrates at high frequency to loosen surface debris and dead cells — a mechanical, stratum-corneum assist, often with a water film. It is not high-intensity focused ultrasound (HIFU) aimed at living SMAS or dermis, and it is not a medical cavitation body device. If the manufacturer’s indication is dermal lifting or living-layer disruption, 1175.115(d)(4) plus 225 ILCS 410/3A-1 keep it off the esthetics menu.

Contraindications and disinfection

Screen before the machine is on:

Pacemaker or implanted defibrillator — no electrical modalities

Metal implants, braces, extensive dental work — galvanic and high-frequency are typical refusals or modifications

  • Pregnancy — skip galvanic, high-frequency, and other currents the manufacturer contraindicates
  • Epilepsy or seizure history — no electrical modalities
  • Heart conditions, uncontrolled high blood pressure — modify or refuse per protocol and manufacturer
  • Open lesions, inflamed or infected skin — 1175.115 already forbids massaging that surface

Fear of electricity — do not force a current; use a non-machine facial ( 1175.835 still trains treatments without machines)

1175.115(b)(3) is the per-client machine rule: all tools, implements, and items that come in direct contact with a client shall be cleaned and disinfected or disposed of after use on each client. That includes glass electrodes, vacuum cups, brush heads, spray nozzles, ultrasonic spatula blades, steamer nozzle exteriors that were wiped on skin or linens, and diamond tips you will meet in Section 15.2. Clean visible debris first, then apply an EPA-registered hospital-grade disinfectant for the labeled contact time. Porous covers, gauze, and disposable electrodes go in the trash. Store cleaned-and-disinfected parts separately from used ones. A glass electrode wiped with a soiled towel and set back in the drawer is not disinfection. It is unprofessional conduct under the opening sentence of 1175.115.

Loading diagram... Illinois facial-machine circuit: current type to sanitation

Exam-typical teaching landmarks for facial machines (not an Illinois statute)