1 Introduction & Exam Overview
0.1 Current Exam Facts: Limited vs Unlimited 0.2 Application, CTS Registration & Exam Day 0.3 Blueprint Weights & Study Strategy
2 Safety: Fall Protection
1.1 OSHA Fall Protection Trigger Heights & Hierarchy 1.2 Personal Fall Arrest Systems 1.3 Guardrails, Warning Lines & Safety Monitors
3 Safety: Access & Equipment
2.1 Ladder Safety for Roofing 2.2 Scaffolding, Roof Brackets & Staging 2.3 Hoists, Material Handling & Crane Basics
4 Safety: PPE & Job Hazards
3.1 PPE Requirements for Roofers 3.2 Fire Safety, Hot Work & Kettle Operations 3.3 Hazard Communication, SDS & Chemical Risks 3.4 Asbestos, Silica, Lead & Heat Illness
5 Preparation: Deck & Substrate
4.1 Roof Deck Types & Inspection 4.2 Tear-Off, Re-Roof Prep & Substrate Repair 4.3 Rigid Board Insulation & Cover Boards
6 Preparation: Underlayment & Fasteners
5.1 Underlayment Types & Ice/Water Shield (Illinois) 5.2 Fasteners, Attachment Patterns & Corrosion 5.3 Moisture Control, Vapor Retarders & Ventilation Basics
7 Steep-Slope: Asphalt Shingles
6.1 Asphalt Shingle Types, Ratings & Installation 6.2 Valleys, Hips, Ridges & Starter Courses 6.3 Steep-Slope Flashing Details
8 Steep-Slope: Tile, Slate, Wood & Metal
7.1 Concrete & Clay Tile Systems 7.2 Slate Roofing 7.3 Wood Shingles & Shakes 7.4 Architectural & Structural Metal (Steep)
9 Steep-Slope: Climate & Reroofing
8.1 Attic Ventilation & Condensation Control 8.2 Ice Dams & Cold-Climate Detailing (Illinois) 8.3 Steep-Slope Reroofing & Overlay Rules
10 Low-Slope: Bituminous Systems
9.1 Built-Up Roofing (BUR) Systems 9.2 Modified Bitumen (APP & SBS) 9.3 Low-Slope Flashing, Edges & Terminations
11 Low-Slope: Single-Ply & SPF
10.1 EPDM Systems & Details 10.2 TPO & PVC Single-Ply Systems 10.3 Spray Polyurethane Foam (SPF) Roofing
12 Low-Slope: Drainage & Waterproofing
11.1 Drainage, Ponding & Roof Slope Design 11.2 Waterproofing & Dampproofing 11.3 Low-Slope Repair & Maintenance Practices
13 Illinois Law: Licensing Act
12.1 Illinois Roofing Industry Licensing Act Overview 12.2 Limited vs Unlimited Licenses & Qualifying Party 12.3 Bonds, Insurance & Workers' Compensation
14 Illinois Law: Business Practices
13.1 Contracts, Advertising & License Display 13.2 Mechanics Liens & Consumer Protections (Illinois) 13.3 Discipline, Penalties & Continuing Education
15 Codes, Estimating & Business
14.1 Building Codes, Permits & Fire/Energy Requirements 14.2 Estimating: Pitch Factors, Areas & Waste 14.3 NASCLA Business Law & Project Management Basics
16 Non-Residential Systems (Unlimited)
15.1 Commercial Roof System Selection 15.2 Structural Loads, Fire Ratings & Energy Code 15.3 Industrial & Specialty Roofing Systems 15.4 Unlimited Upgrade Path & Exam Differences
6.1 Asphalt Shingle Types, Ratings & Installation
Key Takeaways Explain This Topic AI
Three-tab shingles are single-layer strips; laminated (architectural) shingles are multi-layer products with thicker profiles and typically stronger wind ratings
Most asphalt shingles require a minimum roof slope of 2:12 with special underlayment below 4:12; Illinois freeze-thaw climates favor full ice-and-water protection at eaves
Standard fastening is four nails per strip shingle; six nails are required in high-wind zones or when the manufacturer specifies enhanced fastening
Nails must penetrate the deck by at least 3/4 inch (or through the sheathing) and hit the manufacturer’s nail line—high or low nailing voids the wind warranty
ASTM D3462 covers asphalt shingle physical requirements; wind classifications (often ASTM D3161 or D7158) and Class A fire ratings appear on product labels Illinois contractors must match to the job
Last updated: July 2026
6.1 Asphalt Shingle Types, Ratings & Installation
Quick Answer: Illinois steep-slope asphalt work centers on choosing the right shingle type, verifying ASTM and wind ratings, respecting slope and underlayment limits, and driving the correct number of nails into the manufacturer’s nail line so the roof survives Midwest wind and freeze-thaw cycles.
Asphalt shingles dominate Illinois residential steep-slope roofs. On the CTS exam—roughly 20 Domain 3 questions on the Limited scope and about 35 on Unlimited—you are expected to know product types, rating labels, minimum slopes, and fastening patterns, not just how to swing a hammer.
Three-Tab vs Laminated (Architectural) Shingles
Three-tab (strip) shingles are single-thickness asphalt sheets cut into three tabs. They are lighter, usually lower cost, and historically common on starter and older Illinois stock. Exposure is typically 5 inches; each strip is about 36 inches wide. Because they are thinner, wind uplift resistance depends heavily on correct nailing and seal-strip activation.
Laminated (architectural / dimensional) shingles bond two or more layers into a thicker, shadow-lined appearance. They generally carry higher wind ratings, longer warranties, and better hail resistance—valuable across Illinois, where spring storms and winter ice cycles punish roofs. Most modern Illinois re-roofs specify laminated products.
- Feature Three-Tab Laminated / Architectural
- Construction Single layer, cut tabs Multi-layer laminated
- Typical thickness Thinner Thicker, dimensional
Common wind rating Often lower (e.g., 60–70 mph class depending on brand) Often higher (110–130+ mph with enhanced nailing)
- Appearance Flat, uniform tabs Random shadow lines
- Illinois use today Budget / matching older roofs Dominant new and reroof choice
Exam tip: if a question contrasts “3-tab” with “laminated” or “architectural,” laminated means multi-layer dimensional product—not a different fastener brand.
ASTM and Performance Ratings
Product labels and manufacturer instructions are exam gold. Know what the common standards mean:
- Standard / Rating What It Addresses
- ASTM D3462 Asphalt shingle material requirements (asphalt, mat, granules)
- ASTM D3161 Fan-induced wind resistance test (often Class A, D, or F)
- ASTM D7158 Classification of wind resistance from uplift and stiffness (Classes D, G, H)
- UL 790 / ASTM E108 Fire classification (Class A is highest for asphalt systems)
- Algae-resistant (AR) Copper-bearing granules that slow Midwest roof staining
Illinois code jurisdictions typically require Class A fire-rated asphalt assemblies on dwellings. Wind rating on the bundle must meet or exceed the design wind speed for the site when the manufacturer’s enhanced nailing pattern is used. Do not assume a “130 mph” label applies if you only drove four nails when six were required for that rating.
Slope Limits and Underlayment
Asphalt shingles are steep-slope products. Manufacturer and code practice in Illinois generally follow this framework:
- Roof Slope Typical Asphalt Rule
- Below 2:12 Asphalt shingles not allowed—use low-slope systems
2:12 to less than 4:12 Allowed with double underlayment or manufacturer-approved low-slope method; ice barrier at eaves critical in Illinois
4:12 and steeper Standard single underlayment (plus ice barrier where required)
In Illinois freeze-thaw climates, an ice-and-water shield (self-adhered membrane) is required from the eave upward to at least 24 inches inside the exterior wall line—often farther on wide overhangs—because ice dams force meltwater under shingles. Underlayment alone is not a substitute for that eave ice barrier.
Fastening: Four vs Six Nails
Four nails per strip shingle is the standard pattern for many three-tab and laminated products in normal exposure: one nail about 1 inch from each end and nails spaced along the manufacturer’s nail line (often just below the seal strip / through the common bond area on laminates).
Six nails per shingle is required when:
- The manufacturer’s high-wind or enhanced warranty instructions say so
- Local design wind speed or Illinois code adoption triggers enhanced fastening
- You are installing in known high-wind corridors or on steep slopes where the manufacturer mandates it
- Pattern Typical Use
- 4 nails Standard installation per product instructions
- 6 nails High-wind / enhanced fastening to achieve published wind rating
Nails must be corrosion-resistant roofing nails with minimum 12-gauge shank and 3/8-inch head (verify manufacturer). Each nail must penetrate the roof deck at least 3/4 inch , or fully through thinner sheathing. Overdriven nails that cut the shingle, or underdriven nails that sit high, both fail inspection and void wind performance.
Nail location matters more than nail count. High-nailing (above the seal strip / outside the nail zone) and low-nailing (into the exposed butt) are classic CTS failure points. On laminated shingles, nails must catch both the common bond and the overlying laminate layer as the instructions show—missing the laminate layer is a frequent Midwest callback after wind events.
Illinois Wind and Freeze-Thaw Considerations
Illinois roofs see repeated freeze-thaw, ice dams, and thunderstorm outflow winds. Practical exam-relevant rules:
Seal strips must activate. In cold weather, hand-seal or use manufacturer cold-weather procedures so tabs bond before the first windstorm.
Deck must be dry and sound. Wet OSB or cupped plywood leads to fastener withdrawal when ice repeatedly expands in Illinois winters.
Match wind rating to fastening. A high wind classification on the wrapper is meaningless without the nail count and placement that earned that rating.
Starter and drip edge (covered in 6.2) complete the wind and water path—shingles alone do not seal the eave.
Installation Sequence Snapshot
A code-compliant Illinois asphalt install typically follows this order:
Inspect and repair deck; replace damaged sheathing
Install drip edge at eaves (under underlayment) and rakes (over underlayment—verify local/manufacturer sequence)
- Apply ice-and-water barrier at eaves, valleys, and other required locations
- Install underlayment up the field
- Snap chalk lines; install starter course
- Course field shingles with correct exposure and offset
- Flash penetrations and walls as work progresses (see 6.3)
- Cap hips and ridges last
Offset patterns (commonly 6-inch or manufacturer-specified racking/offset) prevent stacked cutouts that create water channels. Never install asphalt shingles over existing shingles unless the manufacturer and local Illinois authority specifically allow a second layer and the structure can carry the load.
Exam Focus
Expect Domain 3 items that ask: minimum slope for asphalt; when six nails are required; where the nail line sits; difference between three-tab and laminated; which ASTM number relates to shingles; and why Illinois ice barriers extend inside the wall line. Answer from manufacturer instructions and the principles above—not from “whatever the last crew did.”