Study guide

3.2 Membrane Filtration & Ion Exchange Softening

Illinois Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Illinois Environmental Laws, Administrative Rules & Operator Certification

1.1 Illinois EPA Regulatory Framework & Permitting 1.2 Wastewater Operator Certification: Classes 1-4, K, R & Collection System 1.3 Drinking Water Operator Certification: Classes A-D

2 Chapter 2: Water Sources, Coagulation, Flocculation & Clarification

2.1 Water Sources, Characteristics & Intake Management 2.2 Coagulation Chemistry & Rapid Mixing 2.3 Flocculation, Sedimentation & Clarifier Operation

3 Chapter 3: Filtration Technologies & Advanced Drinking Water Treatment

3.1 Granular Media Filtration Operations 3.2 Membrane Filtration & Ion Exchange Softening 3.3 Lime-Soda Ash Softening, Iron & Manganese Removal 3.4 Fluoridation, Corrosion Control & Disinfection Byproducts

4 Chapter 4: Disinfection Science & Chemical Feed Systems

4.1 Chlorine Chemistry, Forms & Breakpoint Chlorination 4.2 Contact Time (CT) Calculations & Alternative Disinfectants 4.3 Chemical Feed Equipment, Calibration & Feed Rate Math

5 Chapter 5: Wastewater Preliminary, Primary, Lagoon & Fixed-Film Treatment

5.1 Preliminary Treatment: Screening, Comminution & Grit Removal 5.2 Primary Clarification & Sedimentation 5.3 Waste Stabilization Ponds & Facultative Lagoons 5.4 Trickling Filters & Rotating Biological Contactors 5.5 Imhoff Tanks, Septic Tank Systems & Intermittent Sand Filters

6 Chapter 6: Activated Sludge Treatment & Process Control

6.1 Activated Sludge Variations & Flow Schemes 6.2 Key Operational Parameters: MLSS, F/M, MCRT & SVI 6.3 Return Activated Sludge (RAS) & Waste Activated Sludge (WAS) Control 6.4 Operational Troubleshooting, Bulking & Foaming

7 Chapter 7: Nutrient Removal, Effluent Polishing & Solids Handling

7.1 Biological & Chemical Nutrient Removal 7.2 Effluent Disinfection, Dechlorination & Polishing 7.3 Aerobic & Anaerobic Sludge Digestion 7.4 Sludge Thickening, Dewatering & Biosolids Regulations 7.5 Sludge Drying Beds & Air-Drying Systems

8 Chapter 8: Water Distribution, Wastewater Collection & Pumping Systems

8.1 Water Distribution Piping, Storage & Backflow Prevention 8.2 Wastewater Collection Systems, Inflow & Infiltration 8.3 Lift Stations, Wet Wells & Hydraulics 8.4 Centrifugal & Positive Displacement Pumps 8.5 Flow Measurement, Weirs, Flumes & Meters 8.6 Motors, Electrical Systems, Instrumentation & SCADA

9 Chapter 9: Laboratory Analysis, Applied Calculations, Safety & Plant Administration

9.1 Drinking Water Laboratory Testing & Compliance Sampling 9.2 Wastewater Laboratory Testing & Quality Assurance 9.3 Operator Applied Mathematics: Water & Wastewater Calculations 9.4 Plant Safety, Confined Space Entry & Chlorine Handling 9.5 Plant Management, Preventive Maintenance & Recordkeeping

3.2 Membrane Filtration & Ion Exchange Softening

Key Takeaways Explain This Topic AI

Membrane processes are categorized by pore diameter and separation mechanics: Microfiltration (0.1–0.2 µm) and Ultrafiltration (0.01–0.05 µm) remove suspended matter, protozoa, and viruses, whereas Nanofiltration (0.001–0.01 µm) and Reverse Osmosis (<0.001 µm) remove dissolved hardness, minerals, and PFAS.

Daily direct integrity testing, such as the Pressure Decay Test (PDT) capable of resolving breaches down to 3 microns, is legally mandated under LT2ESWTR to receive pathogen log-removal credits.

Membrane hydraulics are governed by flux (gfd), transmembrane pressure (TMP), and temperature correction factors; irreversible fouling is removed via Clean-In-Place (CIP) using citric acid for scale and caustic/bleach for organics.

Cation exchange softening uses sodium-form polystyrene resins where two Na+ ions are stoichiometrically exchanged for each Ca2+ or Mg2+ ion removed.

Softener units produce zero-hardness effluent blended with bypassed raw water (80–120 mg/L finished target) and regenerate via a 4-step sequence: backwash, brine injection (10–14% NaCl), slow displacement rinse, and fast rinse.

Last updated: September 2026

Membrane Filtration & Ion Exchange Softening

Public water utilities utilize advanced separation processes to control pathogens, disinfection byproduct precursors, dissolved hardness, and emerging contaminants such as per- and polyfluoroalkyl substances (PFAS). Membrane filtration and cation exchange softening provide engineered barriers with selective removal capabilities exceeding conventional granular media.

1. Membrane Filtration Categories & Cutoffs

Membranes are semipermeable synthetic barriers that separate impurities under hydraulic pressure. They are categorized into four classes based on pore diameter, molecular weight cutoff (MWCO), and separation mechanisms:

Microfiltration (MF)

Pore Size & MWCO: 0.1 to 0.2 microns (100 to 200 nm); MWCO > 100,000 Daltons.

Operating Pressure: 5 to 30 psi.

Target Removals: Suspended solids, turbidity, bacteria, and protozoan cysts ( Cryptosporidium , Giardia ) via physical sieving. Ineffective against enteric viruses or dissolved salts.

Ultrafiltration (UF)

Pore Size & MWCO: 0.01 to 0.05 microns (10 to 50 nm); MWCO = 10,000 to 100,000 Daltons.

Operating Pressure: 10 to 50 psi.

Target Removals: Complete protozoan/bacterial barrier, high log-removal of enteric viruses (Hepatitis A, Norovirus; up to 4-log credit), and macromolecules via sieving. Does not remove dissolved minerals.

Nanofiltration (NF)

Pore Size & MWCO: 0.001 to 0.01 microns (1 to 10 nm); MWCO = 200 to 1,000 Daltons.

Operating Pressure: 50 to 150 psi ( "membrane softening" ).

Target Removals: Divalent ions (Ca2+, Mg2+, SO4 2-), color, and DBP precursors via sieving and Donnan charge exclusion. Rejects 40% to 60% of monovalent salts.

Reverse Osmosis (RO)

Structure & MWCO: Dense, non-porous polyamide thin-film composite; pore size < 0.001 microns (< 1 nm); MWCO < 100 Daltons.

Operating Pressure: 150 to 800+ psi to overcome feed osmotic pressure.

Target Removals: Monovalent ions (Na+, Cl-), nitrate (NO3-), heavy metals, radionuclides, dissolved minerals (> 99% TDS rejection), and PFAS via solution-diffusion.

2. Membrane Operational Parameters & Hydraulics

Membrane plant operation depends on four key hydraulic parameters:

Flux (J): Permeate flow rate per unit active membrane area, expressed in gallons per square foot per day (gfd) or liters per square meter per hour (LMH): J = Q p A m = Permeate Flow (gpm) × 1 , 440 min/day Active Membrane Surface Area (sq ft) J = \frac{Q_p}{A_m} = \frac{\text{Permeate Flow (gpm)} \times 1,440 \text{ min/day}}{\text{Active Membrane Surface Area (sq ft)}} J = A m ​ Q p ​ ​ = Active Membrane Surface Area (sq ft) Permeate Flow (gpm) × 1 , 440 min/day ​ Design flux ranges from 15 to 35 gfd for MF/UF and 10 to 20 gfd for spiral-wound NF/RO.

Transmembrane Pressure (TMP): Net driving pressure forcing water through the membrane: TMP = P feed + P concentrate 2 − P permeate \text{TMP} = \frac{P_{\text{feed}} + P_{\text{concentrate}}}{2} - P_{\text{permeate}} TMP = 2 P feed ​ + P concentrate ​ ​ − P permeate ​ For vacuum submerged fibers, TMP = P_tank - P_suction. Increasing TMP at constant flux indicates fouling.

Recovery Rate (%): Percentage of feed water converted to permeate: Recovery (%) = Q permeate Q feed × 100 \text{Recovery (\%)} = \frac{Q_{\text{permeate}}}{Q_{\text{feed}}} \times 100 Recovery (%) = Q feed ​ Q permeate ​ ​ × 100 MF/UF achieves 90% to 95% recovery. NF/RO recovery is limited to 75% to 85% by mineral scaling in the concentrate stream.

Temperature Correction Factor (TCF): Water viscosity increases as temperature drops (~2.5% to 3.0% per °C). At constant pressure, flux drops in winter; to maintain production, TMP must increase. SCADA tracks temperature-normalized specific flux (J at 20°C) to isolate true fouling.

3. Membrane Integrity Testing & Log Credits

Under the SDWA Long Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR), plants receive up to 4-log (99.99%) Cryptosporidium credit by verifying membrane integrity.

Direct Integrity Testing: A daily automated physical challenge on an isolated skid. In the Pressure Decay Test (PDT) , the skid is drained and pressurized with air to 10 to 30 psi. Intact wetted pores hold air behind their capillary bubble point. A broken fiber (> 3 µm) allows air to escape, causing a rapid pressure drop (psi/min) recorded by digital sensors. Direct testing must resolve defects ≤ 3 microns to confirm the Log Reduction Value (LRV).

Indirect Integrity Testing: Continuous filtrate monitoring via turbidimeters (≤ 0.15 NTU) or laser particle counters (2 to 5 µm) to detect sudden fiber breaks between daily PDTs.

4. Fouling Mechanisms & Clean-In-Place (CIP)

Membranes accumulate particulate cakes (silt/flocs), inorganic scale (CaCO3, CaSO4, BaSO4, SiO2), biofouling (bacterial slime/EPS), and organic adsorption (humic acids). Routine backwashes with air scour clear reversible cake layers.

When normalized TMP rises 15% to 20% or normalized flux drops 10% to 15%, a Clean-In-Place (CIP) is conducted:

Acid Wash: 1% to 2% citric acid or dilute hydrochloric acid (pH 2.0 to 3.0) at 35°C to 40°C dissolves mineral scale and metal oxides (iron/manganese).

Caustic/Oxidant Wash: Sodium hydroxide (NaOH, pH 11.0 to 12.0) with sodium hypochlorite (100 to 500 mg/L NaOCl) cleans organics and biofilms from MF/UF membranes.

Caution

Polyamide thin-film composite RO membranes cannot tolerate free chlorine (< 1,000 ppm-hours exposure causes permanent damage). Hypochlorite must never be applied to polyamide RO systems; use non-oxidizing biocides instead.

5. Cation Exchange Water Softening Chemistry & Blending

Cation exchange softening utilizes synthetic polystyrene-divinylbenzene resin beads functionalized with negative sulfonate groups (R-SO3-) charged with mobile sodium (Na+) ions.

Stoichiometric Exchange

Divalent hardness cations carry higher charge and affinity than sodium. As hard water filters through the resin, each divalent cation displaces two sodium ions: Ca 2 + + 2 R-SO 3 Na ⇌ ( R-SO 3 ) 2 Ca + 2 Na + \text{Ca}^{2+} + 2 \text{ R-SO}_3\text{Na} \rightleftharpoons (\text{R-SO}_3)_2\text{Ca} + 2 \text{ Na}^+ Ca 2 + + 2 R-SO 3 ​ Na ⇌ ( R-SO 3 ​ ) 2 ​ Ca + 2 Na + Mg 2 + + 2 R-SO 3 Na ⇌ ( R-SO 3 ) 2 Mg + 2 Na + \text{Mg}^{2+} + 2 \text{ R-SO}_3\text{Na} \rightleftharpoons (\text{R-SO}_3)_2\text{Mg} + 2 \text{ Na}^+ Mg 2 + + 2 R-SO 3 ​ Na ⇌ ( R-SO 3 ​ ) 2 ​ Mg + 2 Na +

Split-Stream Blending

Ion exchange produces zero-hardness effluent (0 mg/L as CaCO3). Pure softened water is corrosive and strips pipe scales. Plants bypass a calculated portion of raw water and blend it with softened effluent to maintain a finished target hardness of 80 to 120 mg/L as CaCO3 : Q blend = Q total × ( H target H raw ) and Q soft = Q total − Q blend Q_{\text{blend}} = Q_{\text{total}} \times \left(\frac{H_{\text{target}}}{H_{\text{raw}}}\right) \quad \text{and} \quad Q_{\text{soft}} = Q_{\text{total}} - Q_{\text{blend}} Q blend ​ = Q total ​ × ( H raw ​ H target ​ ​ ) and Q soft ​ = Q total ​ − Q blend ​

6. Four-Step Ion Exchange Regeneration Sequence

When resin sites become exhausted, hardness breaks through. The unit is regenerated through a 4-step sequence:

Backwash (5 to 10 min): Upflow of filtered water at 5 to 8 gpm/sq ft expands the bed by 50% to 75% , scrubbing trapped solids and reclassifying resin beads.

Brine Injection (20 to 30 min): Downflow of 10% to 14% NaCl solution (6 to 15 lbs salt per cubic foot of resin). High sodium concentration drives mass action, displacing bound Ca2+ and Mg2+ from resin sites back into solution.

Slow Rinse / Displacement (20 to 40 min): Clean water at the brine injection rate pushes the brine plug slowly through the bed, maximizing contact time.

Fast Rinse (10 to 15 min): Downflow at service rate (1.5 to 3.0 gpm/cu ft) flushes spent chlorides and residual salt to waste until effluent conductivity reaches baseline potable levels.

Waste Brine Disposal

Spent softener brine is a concentrated, high-chloride waste stream. Under IEPA regulations, brine cannot be discharged to unlined lagoons or freshwater streams without an NPDES permit or industrial sewer discharge approval.