Study guide
13.4 Psychrometric Properties, Processes & Air Conditioning Systems
Coal India Management Trainee CIL MT
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: CIL MT Exam Overview & Coal Sector Landscape
1.1 CIL MT Exam Pattern, Marking Scheme & Strategy 1.2 Coal India Limited: Corporate Structure, Maharatna Status & Subsidiaries 1.3 Indian Coal Mining Sector, Energy Mix & Environmental Regulations
2 Chapter 2: Paper-I General Awareness, Polity & Current Affairs
2.1 Indian Constitution, Governance & Statutory Bodies 2.2 Indian Economy, Union Budget & Economic Planning 2.3 Indian Geography, Mineral Belts & Environmental Ecology 2.4 Modern Indian History, Freedom Struggle & Cultural Heritage 2.5 General Science: Physics, Chemistry & Biology Fundamentals 2.6 Inventions, Discoveries & Scientific-Technological Development 2.7 Uses of Internet, Computer Awareness & Digital Governance 2.8 National & International Organisations 2.9 Awards, Honours & Sports 2.10 Books & Authors, Important Monuments & Places of India 2.11 Ports, Power Plants & Infrastructure of India 2.12 Climate Change, SDGs, National Parks & Wildlife Sanctuaries 2.13 Flagship Government Programmes & Current Affairs Method 2.14 World Physical, Social & Economic Geography
3 Chapter 3: Paper-I Reasoning & Logical Ability
3.1 Series Completion, Coding-Decoding & Semantic Analogies 3.2 Syllogisms, Logical Deduction & Venn Diagrams 3.3 Seating Arrangements, Linear/Circular Alignments & Puzzles 3.4 Direction Sense, Blood Relations & Order/Ranking 3.5 Alphabetical & Alphanumeric Series 3.6 Statement & Conclusions, Statement & Arguments 3.7 Clocks & Calendars 3.8 Cubes, Dice & Figure Counting 3.9 Mirror Images, Water Images, Embedded Figures & Non-Verbal Series 3.10 Decision Making & Data Analysis in Reasoning
4 Chapter 4: Paper-I Numerical Ability & Quantitative Aptitude
4.1 Arithmetic Foundations: Percentages, Profit & Loss, Ratio & Proportion 4.2 Averages, Simple/Compound Interest, Alligations & Mixtures 4.3 Time & Work, Pipes & Cisterns, Time, Speed & Distance 4.4 Algebra, Mensuration, Geometry & Data Interpretation (DI) 4.5 Number System, LCM, HCF & Decimal Fractions 4.6 Surds, Indices & Simplification 4.7 Problems on Ages 4.8 Boats & Streams and Problems on Trains 4.9 Permutations & Combinations 4.10 Probability for Quantitative Aptitude
5 Chapter 5: Paper-I General English & Verbal Ability
5.1 English Grammar, Error Spotting & Sentence Correction 5.2 Vocabulary Building: Synonyms, Antonyms, Idioms & Phrases 5.3 Reading Comprehension, Cloze Tests & Para Jumbles 5.4 Fill in the Blanks, Cloze Passages & Sentence Completion 5.5 Jumbled Sentences & Sentence Improvement
6 Chapter 6: Paper-II Engineering Mathematics
6.1 Matrix Algebra, Rank & Systems of Linear Equations 6.2 Eigenvalues, Eigenvectors & the Cayley-Hamilton Theorem 6.3 Limits, Continuity, Differentiability & Mean Value Theorems 6.4 Maxima-Minima, Indeterminate Forms & Taylor Series 6.5 Definite, Improper, Double & Triple Integrals 6.6 Partial Derivatives, Total Derivative & Multivariable Optimisation 6.7 First-Order Differential Equations: Linear & Non-Linear 6.8 Higher-Order Linear Differential Equations & Engineering Applications 6.9 Laplace Transforms & Transfer-Function Methods 6.10 Probability, Conditional Probability & Bayes' Theorem 6.11 Random Variables, Distributions & Descriptive Statistics 6.12 Numerical Methods: Root Finding, Integration & ODE Solvers
7 Chapter 7: Paper-II Engineering Mechanics & Statics-Dynamics
7.1 Force Systems, Coplanar Equilibrium & Lami's Theorem 7.2 Plane Trusses, Friction Mechanics & Screws/Wedges 7.3 Centroids, Center of Gravity & Moment of Inertia 7.4 Kinematics, Kinetics of Particles & Rigid Body Dynamics 7.5 Virtual Work & Lagrange's Equation 7.6 Rolling Friction, Belt-Pulley Drives, Brakes, Clutches & Vehicle Dynamics
8 Chapter 8: Paper-II Mechanics of Materials & Structural Integrity
8.1 Simple Stresses, Strains, Elastic Moduli & Thermal Stresses 8.2 Principal Stresses, Strain Energy & Mohr's Circle 8.3 Shear Force & Bending Moment Diagrams, Beam Bending & Shear Stresses 8.4 Torsion of Circular Shafts, Springs & Column Buckling 8.5 Thin Cylinders, Spheres & Thick-Walled Pressure Vessels 8.6 Deflection of Beams: Double Integration, Macaulay & Moment-Area 8.7 Shear Centre & Unsymmetrical Bending 8.8 Strain Gauges, Rosettes & Experimental Stress Analysis 8.9 Mechanical Testing: Universal Testing Machine, Hardness & Impact
9 Chapter 9: Paper-II Theory of Machines & Mechanical Vibrations
9.1 Simple Mechanisms, Kinematic Inversions & Velocity/Acceleration Diagrams 9.2 Cams & Followers, Toothed Gearing & Epicyclic Gear Trains 9.3 Flywheels, Centrifugal/Inertia Governors & Rotor Balancing 9.4 Free, Damped & Forced Single-Degree-of-Freedom Vibrations 9.5 Gyroscopic Couple & Gyroscopic Effects
10 Chapter 10: Paper-II Machine Design & Failure Theories
10.1 Static Failure Theories & Variable/Fatigue Loading 10.2 Design of Threaded Fasteners, Welded & Riveted Joints 10.3 Design of Shafts, Keys, Couplings & Rolling/Sliding Bearings 10.4 Design of Spur, Helical, Bevel & Worm Gears 10.5 Design of Helical, Leaf & Torsion Springs 10.6 Design of Brakes & Clutches: Energy, Lining Pressure & Heat
11 Chapter 11: Paper-II Fluid Mechanics & Hydraulic Machinery
11.1 Fluid Properties, Hydrostatic Forces & Buoyancy 11.2 Fluid Kinematics, Continuity & Bernoulli's Equation 11.3 Viscous Flow in Pipes, Boundary Layer & Minor Losses 11.4 Hydraulic Turbines, Centrifugal & Reciprocating Pumps 11.5 Dimensional Analysis, Similitude & Model Testing 11.6 Control-Volume Analysis: Continuity, Momentum & Energy
12 Chapter 12: Paper-II Thermodynamics, Thermal Cycles & Turbomachinery
12.1 Fundamental Concepts, First & Second Laws of Thermodynamics 12.2 Entropy, Availability, Exergy & Properties of Pure Substances 12.3 Air-Standard Gas Power Cycles: Otto, Diesel, Dual & Brayton 12.4 Vapour Power Cycles: Ideal, Reheat & Regenerative Rankine Cycles 12.5 Thermodynamic Relations: Maxwell, Clausius-Clapeyron & Joule-Thomson 12.6 Behaviour of Ideal & Real Gases and Equations of State 12.7 Air & Gas Compressors: Reciprocating, Rotary & Multi-Stage 12.8 Steam & Gas Turbines: Impulse, Reaction & Velocity Diagrams
13 Chapter 13: Paper-II Heat Transfer, Refrigeration & Air Conditioning
13.1 Steady & Unsteady Conduction, Extended Surfaces (Fins) 13.2 Forced/Natural Convection, Radiation & Heat Exchanger LMTD/NTU 13.3 Vapour Compression & Vapour Absorption Refrigeration Systems 13.4 Psychrometric Properties, Processes & Air Conditioning Systems 13.5 Gas Refrigeration, Heat Pump Cycles & Cryogenics
14 Chapter 14: Paper-II Materials Science, Metallurgy & Manufacturing Technology
14.1 Crystal Structures, Phase Diagrams & Iron-Iron Carbide Equilibrium 14.2 Heat Treatment Processes & Engineering Alloy Steels 14.3 Casting Processes, Metal Forming & Welding Metallurgy 14.4 Metal Cutting Mechanics, Tool Life & Machine Tools 14.5 Plastic Deformation, Yield Criteria & Load Estimation in Bulk Forming 14.6 Sheet Metal Forming: Shearing, Bending & Deep Drawing 14.7 Powder Metallurgy 14.8 Brazing, Soldering & Adhesive Bonding 14.9 Non-Traditional Machining: EDM, ECM, USM, AJM, LBM & EBM 14.10 Abrasive Machining, Grinding & Superfinishing 14.11 Principles of Work Holding, Jigs & Fixtures 14.12 Economics of Machining & Tool Life Optimisation
15 Chapter 15: Paper-II Metrology, Quality Control & Industrial Engineering / OR
15.1 Limits, Fits, Tolerances, Gauges & Surface Metrology 15.2 Production Planning, Forecasting & Inventory Control Models 15.3 Operations Research: Linear Programming & Transportation/Assignment 15.4 Project Management: CPM, PERT, Network Analysis & Crashing 15.5 Comparators & Interferometry 15.6 Coordinate Measuring Machines & Machine Tool Alignment Testing 15.7 Computer Integrated Manufacturing: CAD/CAM & Integration Tools 15.8 NC/CNC Machines & CNC Part Programming 15.9 Material Requirements Planning, Scheduling & Sequencing 15.10 Queuing Theory & Simple Queuing Models 15.11 Network Flow Models: Shortest Route, Maximal Flow & Spanning Tree
13.4 Psychrometric Properties, Processes & Air Conditioning Systems
Key Takeaways Explain This Topic AI
Moist air properties follow Dalton's law of partial pressures P = P_a + P_v, with specific humidity omega = 0.622*P_v/(P - P_v) and relative humidity phi = P_v/P_vs * 100%; at 100% saturation DBT = WBT = DPT.
Moist air specific enthalpy is calculated as h = 1.005 DBT + omega (2501 + 1.88*DBT) kJ/kg d.a., where 1.005 kJ/kg·K is dry air specific heat and 2501 kJ/kg is water latent heat of vaporization at 0°C.
Fundamental psychrometric processes are mapped as directional vectors on the psychrometric chart: sensible heating/cooling (horizontal omega = const), humidification/dehumidification (vertical DBT = const), cooling & dehumidification (diagonal down-left), and adiabatic evaporative cooling along constant WBT/enthalpy lines.
Cooling coil performance is governed by the Bypass Factor BPF = (T_exit - T_ADP)/(T_inlet - T_ADP) and Contact Factor eta_c = 1 - BPF, where Apparatus Dew Point (ADP) is the effective coil surface temperature.
The Sensible Heat Factor SHF = RSH / (RSH + RLH) establishes the slope of the room condition line on the psychrometric chart, targeting industrial comfort design standards of 24°C DBT and 50-60% RH.
Last updated: August 2026
Psychrometric Properties, Processes & Air Conditioning Systems
Psychrometry is the branch of engineering science dedicated to the thermodynamic evaluation of moist air—a binary mixture of dry air and water vapor. In coal mining operations, precise psychrometric control is essential for maintaining human thermal comfort, mitigating heat stress in deep underground shafts (where auto-compression and geothermal gradients raise intake air temperatures), preventing spontaneous combustion in coal storage silos, and ensuring proper climate control in heavy equipment control cabins and computerized washery dispatch rooms.
1. Atmospheric Air Composition & Dalton's Law of Partial Pressures
Atmospheric moist air is treated as an ideal gas mixture obeying Dalton's Law of Partial Pressures . The total barometric pressure P P P is the sum of the partial pressure of dry air ( P a P_a P a ) and the partial pressure of water vapor ( P v P_v P v ): P = P a + P v P = P_a + P_v P = P a + P v
Standard Atmospheric Pressure at Sea Level: P = 101.325 kPa = 760 mm Hg = 1.01325 bar P = 101.325\text{ kPa} = 760\text{ mm Hg} = 1.01325\text{ bar} P = 101.325 kPa = 760 mm Hg = 1.01325 bar .
Characteristic Gas Constants: Dry air R a = 0.2870 kJ/kg ⋅ K R_a = 0.2870\text{ kJ/kg}\cdot\text{K} R a = 0.2870 kJ/kg ⋅ K , Water vapor R v = 0.4615 kJ/kg ⋅ K R_v = 0.4615\text{ kJ/kg}\cdot\text{K} R v = 0.4615 kJ/kg ⋅ K . R a R v = 0.2870 0.4615 = 18.015 28.966 = 0.622 \frac{R_a}{R_v} = \frac{0.2870}{0.4615} = \frac{18.015}{28.966} = 0.622 R v R a = 0.4615 0.2870 = 28.966 18.015 = 0.622 +-----------------------------------------------------------------------------------------+
- | PSYCHROMETRIC TEMPERATURE RELATIONSHIPS |
- | |
- | UNSATURATED MOIST AIR (Relative Humidity < 100%): |
- | |
- | Dry Bulb Temp (DBT) > Wet Bulb Temp (WBT) > Dew Point Temp (DPT) |
- | |
- | - Dry Bulb Temp (DBT): True sensible kinetic temperature measured by bare thermometer.|
- | - Wet Bulb Temp (WBT): Lowest adiabatic evaporation temp measured by wet-wick sensor. |
- | - Dew Point Temp (DPT): Saturation temperature corresponding to partial pressure Pv. |
- | |
- | SATURATED MOIST AIR (Relative Humidity = 100%): |
- | |
- | Dry Bulb Temp (DBT) = Wet Bulb Temp (WBT) = Dew Point Temp (DPT) |
- +-----------------------------------------------------------------------------------------+
- 2. Fundamental Psychrometric Properties & Governing Formulations
- 1. Specific Humidity / Humidity Ratio ( ω \omega ω )
The mass of water vapor present per unit mass of dry air: ω = m v m a = P v V / ( R v T ) P a V / ( R a T ) = R a R v P v P a = 0.622 P v P − P v ( kg water vapor kg dry air ) \omega = \frac{m_v}{m_a} = \frac{P_v V / (R_v T)}{P_a V / (R_a T)} = \frac{R_a}{R_v} \frac{P_v}{P_a} = 0.622 \frac{P_v}{P - P_v} \quad \left(\frac{\text{kg water vapor}}{\text{kg dry air}}\right) ω = m a m v = P a V / ( R a T ) P v V / ( R v T ) = R v R a P a P v = 0.622 P − P v P v ( kg dry air kg water vapor ) In terms of specific humidity: P v = ω P 0.622 + ω \text{In terms of specific humidity: } \quad P_v = \frac{\omega P}{0.622 + \omega} In terms of specific humidity: P v = 0.622 + ω ω P
2. Relative Humidity ( ϕ \phi ϕ or RH \text{RH} RH )
The ratio of the actual partial pressure of water vapor P v P_v P v to the saturation pressure of water vapor P v s P_{vs} P v s at the same dry bulb temperature: ϕ = P v P v s ∣ DBT = m v m v s ∣ DBT × 100 % \phi = \left.\frac{P_v}{P_{vs}}\right|_{\text{DBT}} = \left.\frac{m_v}{m_{vs}}\right|_{\text{DBT}} \times 100\% ϕ = P v s P v DBT = m v s m v DBT × 100%
3. Degree of Saturation ( μ \mu μ )
The ratio of actual specific humidity ω \omega ω to the saturated specific humidity ω s \omega_s ω s at the same dry bulb temperature: μ = ω ω s ∣ DBT = 0.622 P v P − P v 0.622 P v s P − P v s = ϕ [ P − P v s P − P v ] \mu = \left.\frac{\omega}{\omega_s}\right|_{\text{DBT}} = \frac{0.622 \frac{P_v}{P - P_v}}{0.622 \frac{P_{vs}}{P - P_{vs}}} = \phi \left[\frac{P - P_{vs}}{P - P_v}\right] μ = ω s ω DBT = 0.622 P − P v s P v s 0.622 P − P v P v = ϕ [ P − P v P − P v s ]
Note
Because P v ≤ P v s P_v \le P_{vs} P v ≤ P v s , the term [ P − P v s P − P v ] ≤ 1 \left[\frac{P - P_{vs}}{P - P_v}\right] \le 1 [ P − P v P − P v s ] ≤ 1 . Therefore, for unsaturated air, μ ≤ ϕ \mu \le \phi μ ≤ ϕ ; at saturation ( ϕ = 1.0 \phi = 1.0 ϕ = 1.0 ), μ = ϕ = 1.0 \mu = \phi = 1.0 μ = ϕ = 1.0 .
4. Specific Enthalpy of Moist Air ( h h h )
The total thermal energy per kilogram of dry air, referencing dry air and liquid water at 0 ∘ C 0^{\circ}\text{C} 0 ∘ C ( h a = 0 , h w = 0 h_a = 0, h_w = 0 h a = 0 , h w = 0 ): h = h a + ω h v = c p a ⋅ DBT + ω ( h f g , 0 + c p v ⋅ DBT ) h = h_a + \omega h_v = c_{pa} \cdot \text{DBT} + \omega (h_{fg,0} + c_{pv} \cdot \text{DBT}) h = h a + ω h v = c p a ⋅ DBT + ω ( h f g , 0 + c p v ⋅ DBT )
Taking c p a = 1.005 kJ/kg ⋅ K c_{pa} = 1.005\text{ kJ/kg}\cdot\text{K} c p a = 1.005 kJ/kg ⋅ K , h f g , 0 = 2501 kJ/kg h_{fg,0} = 2501\text{ kJ/kg} h f g , 0 = 2501 kJ/kg , and c p v = 1.88 kJ/kg ⋅ K c_{pv} = 1.88\text{ kJ/kg}\cdot\text{K} c p v = 1.88 kJ/kg ⋅ K : h = 1.005 DBT + ω ( 2501 + 1.88 DBT ) ( kJ kg dry air ) h = 1.005 \, \text{DBT} + \omega \left(2501 + 1.88 \, \text{DBT}\right) \quad \left(\frac{\text{kJ}}{\text{kg dry air}}\right) h = 1.005 DBT + ω ( 2501 + 1.88 DBT ) ( kg dry air kJ )
5. Moist Air Specific Volume ( v v v )
Volume occupied by the mixture per unit mass of dry air: v = V m a = R a T P a = R a T P − P v = 0.2870 ( DBT + 273.15 ) P − P v ( m 3 kg dry air ) v = \frac{V}{m_a} = \frac{R_a T}{P_a} = \frac{R_a T}{P - P_v} = \frac{0.2870 (\text{DBT} + 273.15)}{P - P_v} \quad \left(\frac{\text{m}^3}{\text{kg dry air}}\right) v = m a V = P a R a T = P − P v R a T = P − P v 0.2870 ( DBT + 273.15 ) ( kg dry air m 3 )
3. The Psychrometric Chart: Coordinate Geometry & Lines of State
The psychrometric chart visually maps thermodynamic states of moist air at standard atmospheric pressure ( 101.325 kPa 101.325\text{ kPa} 101.325 kPa ). +-----------------------------------------------------------------------------------------+
- | PSYCHROMETRIC CHART TOPOLOGY & LINES |
- | |
- | Specific |
- | Humidity (w) Saturation Curve (phi=100%) |
- | ^ / |
- | | / |
- | | / / Constant Rel. Humidity |
- | | / / |
- | | / / |
- | | Constant Enthalpy (h) / / |
- | | & Constant WBT Lines / / |
- | | \ / / |
- | | \ / / Constant Specific |
- | | \ / / Volume Lines (v) |
- | | \ / / \ |
- | | \ / / \ |
- | | \ / / \ |
- | | \ / / \ |
- | +---------------------------+--+----------------------+--------------------> |
- | Constant Dry Bulb Temp (DBT) Lines |
+-----------------------------------------------------------------------------------------+ +-----------------------------------------------------------------------------------------+
- | ORIENTATION OF LINES ON THE CHART |
- | |
- | 1. Constant Dry Bulb Temp (DBT): Vertical, parallel straight lines. |
- | 2. Constant Specific Humidity (w): Horizontal, parallel straight lines. |
- | 3. Constant Dew Point Temp (DPT): Horizontal lines extending left to Sat. Curve. |
- | 4. Constant Relative Humidity (phi): Curved lines bowing upward from bottom-left. |
- | 5. Constant Enthalpy / WBT: Diagonal lines sloping downward to the right. |
- | 6. Constant Specific Volume (v): Steeply inclined diagonal lines. |
- +-----------------------------------------------------------------------------------------+
4. Fundamental Psychrometric Processes +-----------------------------------------------------------------------------------------+
- | VECTOR MAP OF PSYCHROMETRIC PROCESSES |
- | |
- | Humidification (w increases) |
- | ^ |
- | Heating & Humidification | Cooling & Humidification |
- | (Winter A/C) | (Air Washer / Evaporative) |
- | \ | / |
- | \ | / |
- | \ | / |
- | Sensible Cooling <----------------------+----------------------> Sensible Heating |
- | (w = const, DBT drops) | (w = const, DBT rises|
- | / | \ |
- | / | \ |
- | / | \ |
- | Cooling & Dehumidification| Chemical Dehumidification |
- | (Summer A/C) v (Desiccant Dryer) |
- | Dehumidification (w decreases) |
- +-----------------------------------------------------------------------------------------+
- Summary of Key Thermodynamic Air Conditioning Processes
- Process DBT WBT DPT Specific Humidity ω \omega ω Relative Humidity ϕ \phi ϕ Enthalpy h h h
- Sensible Heating ↑ \uparrow ↑ ↑ \uparrow ↑ Constant Constant ↓ \downarrow ↓ ↑ \uparrow ↑
- Sensible Cooling ↓ \downarrow ↓ ↓ \downarrow ↓ Constant Constant ↑ \uparrow ↑ ↓ \downarrow ↓
- Humidification Constant ↑ \uparrow ↑ ↑ \uparrow ↑ ↑ \uparrow ↑ ↑ \uparrow ↑ ↑ \uparrow ↑
- Dehumidification Constant ↓ \downarrow ↓ ↓ \downarrow ↓ ↓ \downarrow ↓ ↓ \downarrow ↓ ↓ \downarrow ↓
Cooling & Dehumidification ↓ \downarrow ↓ ↓ \downarrow ↓ ↓ \downarrow ↓ ↓ \downarrow ↓ ↑ \uparrow ↑ (usually) ↓ \downarrow ↓
- Heating & Humidification ↑ \uparrow ↑ ↑ \uparrow ↑ ↑ \uparrow ↑ ↑ \uparrow ↑ Varies ↑ \uparrow ↑
- Evaporative Cooling ↓ \downarrow ↓ Constant ↑ \uparrow ↑ ↑ \uparrow ↑ ↑ \uparrow ↑ Constant
Chemical Dehumidification ↑ \uparrow ↑ ≈ \approx ≈ Const ↓ \downarrow ↓ ↓ \downarrow ↓ ↓ \downarrow ↓ ≈ \approx ≈ Const
5. Adiabatic Mixing of Two Moist Air Streams
When two air streams 1 (flow rate m ˙ a 1 \dot{m}_{a1} m ˙ a 1 , state DBT 1 , ω 1 , h 1 \text{DBT}_1, \omega_1, h_1 DBT 1 , ω 1 , h 1 ) and 2 (flow rate m ˙ a 2 \dot{m}_{a2} m ˙ a 2 , state DBT 2 , ω 2 , h 2 \text{DBT}_2, \omega_2, h_2 DBT 2 , ω 2 , h 2 ) mix adiabatically under steady flow: +-----------------------------------------------------------------------------------------+
- | ADIABATIC MIXING & LEVER RULE |
- | |
- | Conservation of Dry Air: m_dot_a1 + m_dot_a2 = m_dot_a3 |
- | Conservation of Water Vapor: m_dot_a1 * w1 + m_dot_a2 * w2 = m_dot_a3 * w3 |
- | Conservation of Energy: m_dot_a1 * h1 + m_dot_a2 * h2 = m_dot_a3 * h3 |
- | |
- | Mixed State Point (3): |
- | w3 = (m_dot_a1 * w1 + m_dot_a2 * w2) / (m_dot_a1 + m_dot_a2) |
- | h3 = (m_dot_a1 * h1 + m_dot_a2 * h2) / (m_dot_a1 + m_dot_a2) |
- | T3 approx (m_dot_a1 * T1 + m_dot_a2 * T2) / (m_dot_a1 + m_dot_a2) |
- | |
- | GEOMETRIC LEVER RULE: |
- | State 3 lies on the straight line connecting State 1 and State 2 such that: |
- | (Line Segment 1-3) / (Line Segment 3-2) = m_dot_a2 / m_dot_a1 |
- +-----------------------------------------------------------------------------------------+
- 6. Cooling Coil Performance: Bypass Factor (BPF) & Apparatus Dew Point (ADP)
In an air conditioning cooling coil, a fraction of air contacts the coil tubes and fins directly, reaching the Apparatus Dew Point ( T ADP T_{\text{ADP}} T ADP ) at 100% saturation, while the remaining fraction bypasses the coil surface completely unaffected. +-----------------------------------------------------------------------------------------+
- | COIL BYPASS FACTOR & CONTACT FACTOR |
- | |
- | Inlet Air (State 1: T1, w1) |
- | ========================> [ COOLING COIL (Surface Temp = T_ADP) ] ====> Exit Air (T2, |
- | w2) |
- | |
- | Bypass Factor (BPF or X): |
- | BPF = (T2 - T_ADP) / (T1 - T_ADP) = (w2 - w_ADP) / (w1 - w_ADP) |
- | = (h2 - h_ADP) / (h1 - h_ADP) |
- | |
- | Contact Factor (eta_c): |
- | eta_c = 1 - BPF = (T1 - T2) / (T1 - T_ADP) |
- +-----------------------------------------------------------------------------------------+
- Factors Governing Bypass Factor (BPF)
Number of Coil Rows: Increasing tube rows increases air-surface contact ⟹ BPF \implies \text{BPF} ⟹ BPF decreases.
Fin Density (Fins per inch): Increasing fin density reduces open gap area ⟹ BPF \implies \text{BPF} ⟹ BPF decreases.
Air Face Velocity: Increasing velocity reduces contact dwell time ⟹ BPF \implies \text{BPF} ⟹ BPF increases.
7. Sensible Heat Factor (SHF) & Space Air Conditioning Loads
Thermal loads in an air-conditioned space comprise sensible heat gain ( RSH \text{RSH} RSH , raising temperature from people, lights, equipment) and latent heat gain ( RLH \text{RLH} RLH , adding moisture from respiration, infiltration, steam): Room Sensible Heat ( RSH ) = m ˙ a c p m ( T room − T supply ) = 1.21 V ˙ ( T room − T supply ) ( kW ) \text{Room Sensible Heat } (\text{RSH}) = \dot{m}_a c_{pm} (T_{\text{room}} - T_{\text{supply}}) = 1.21 \, \dot{V} \, (T_{\text{room}} - T_{\text{supply}}) \quad (\text{kW}) Room Sensible Heat ( RSH ) = m ˙ a c p m ( T room − T supply ) = 1.21 V ˙ ( T room − T supply ) ( kW ) Room Latent Heat ( RLH ) = m ˙ a h f g ( ω room − ω supply ) = 3010 V ˙ ( ω room − ω supply ) ( kW ) \text{Room Latent Heat } (\text{RLH}) = \dot{m}_a h_{fg} (\omega_{\text{room}} - \omega_{\text{supply}}) = 3010 \, \dot{V} \, (\omega_{\text{room}} - \omega_{\text{supply}}) \quad (\text{kW}) Room Latent Heat ( RLH ) = m ˙ a h f g ( ω room − ω supply ) = 3010 V ˙ ( ω room − ω supply ) ( kW ) Room Total Heat ( RTH ) = RSH + RLH \text{Room Total Heat } (\text{RTH}) = \text{RSH} + \text{RLH} Room Total Heat ( RTH ) = RSH + RLH Sensible Heat Factor (SHF) = RSH RSH + RLH = RSH RTH \text{Sensible Heat Factor (SHF)} = \frac{\text{RSH}}{\text{RSH} + \text{RLH}} = \frac{\text{RSH}}{\text{RTH}} Sensible Heat Factor (SHF) = RSH + RLH RSH = RTH RSH +-----------------------------------------------------------------------------------------+
- | ROOM CONDITION LINE ON PSYCHROMETRIC CHART |
- | |
- | Specific |
- | Humidity (w) |
- | ^ |
- | | Saturation Curve |
- | | / |
- | | / Room State (R) |
- | | / * |
- | | / / |
- | | / Coil Exit (2)/ <--- Slope of Line = SHF |
- | | / * / (RSH / RTH) |
- | | ADP *-------/-------/ |
- | | / |
- | +--------------+-------------------------------------------------------------> |
- | T_ADP T2(Supply) T_Room DBT |
- +-----------------------------------------------------------------------------------------+
- 8. Human Thermal Comfort & Mine Ventilation Standards
Human thermal equilibrium is governed by the body heat balance: M ± R ± C − E = S = 0 M \pm R \pm C - E = S = 0 M ± R ± C − E = S = 0 , where M M M is metabolic rate, R R R is radiation, C C C is convection, E E E is evaporative sweating, and S S S is rate of heat storage.
Industrial Design Guidelines (ASHRAE / Indian Standards IS 1391)
Comfort Zone Dry Bulb Temperature: 23 ∘ C − 25 ∘ C 23^{\circ}\text{C} - 25^{\circ}\text{C} 2 3 ∘ C − 2 5 ∘ C (Standard Design Target: 24 ∘ C 24^{\circ}\text{C} 2 4 ∘ C ).
Comfort Relative Humidity: 50 % − 60 % 50\% - 60\% 50% − 60% (Below 30% causes mucosal drying and electrostatic discharge; above 70% inhibits sweat evaporation, inducing heat strain).
Air Velocity: 0.15 − 0.25 m/s 0.15 - 0.25\text{ m/s} 0.15 − 0.25 m/s in occupied zones.
Deep Underground Mine Environments: Coal Mines Regulations (CMR) mandate effective temperature thresholds ( < 30.5 ∘ C < 30.5^{\circ}\text{C} < 30. 5 ∘ C wet bulb) in working coal faces to prevent heat stroke and fatal miner fatigue.
- 9. Step-by-Step Worked Problems: Psychrometric Load & Coil Sizing
- Worked Example 1: Psychrometric Properties Calculation
Atmospheric air is at DBT = 35 ∘ C \text{DBT} = 35^{\circ}\text{C} DBT = 3 5 ∘ C and P = 101.325 kPa P = 101.325\text{ kPa} P = 101.325 kPa with a relative humidity of ϕ = 60 % \phi = 60\% ϕ = 60% . Saturated vapor pressure at 35 ∘ C 35^{\circ}\text{C} 3 5 ∘ C is P v s = 5.628 kPa P_{vs} = 5.628\text{ kPa} P v s = 5.628 kPa . Calculate:
- Vapor partial pressure P v P_v P v
- Specific humidity ω \omega ω
Specific enthalpy h h h +-----------------------------------------------------------------------------------------+
- | PSYCHROMETRIC PROPERTY CALCULATION |
- | |
- | STEP 1: Calculate Water Vapor Partial Pressure Pv |
- | Pv = phi * Pvs = 0.60 * 5.628 kPa = 3.3768 kPa |
- | |
- | STEP 2: Calculate Specific Humidity (w) |
- | w = 0.622 * Pv / (P - Pv) |
- | w = 0.622 * (3.3768) / (101.325 - 3.3768) = 2.10037 / 97.9482 |
- | w = 0.02144 kg w.v. / kg d.a. = 21.44 g/kg d.a. |
- | |
- | STEP 3: Calculate Specific Enthalpy (h) |
- | h = 1.005 * DBT + w * (2501 + 1.88 * DBT) |
- | h = 1.005 * (35) + 0.02144 * (2501 + 1.88 * 35) |
- | h = 35.175 + 0.02144 * (2501 + 65.8) = 35.175 + 0.02144 * (2566.8) |
- | h = 35.175 + 55.032 = 90.21 kJ/kg d.a. |
- +-----------------------------------------------------------------------------------------+
- Worked Example 2: Cooling Coil Sizing with Bypass Factor
An air handling unit (AHU) conditions 1.5 kg/s 1.5\text{ kg/s} 1.5 kg/s of outdoor air entering at T 1 = 38 ∘ C T_1 = 38^{\circ}\text{C} T 1 = 3 8 ∘ C DBT and ω 1 = 0.020 kg/kg d.a. \omega_1 = 0.020\text{ kg/kg d.a.} ω 1 = 0.020 kg/kg d.a. across a cooling coil with ADP = 10 ∘ C \text{ADP} = 10^{\circ}\text{C} ADP = 1 0 ∘ C and Bypass Factor BPF = 0.15 \text{BPF} = 0.15 BPF = 0.15 . Calculate the off-coil temperature T 2 T_2 T 2 and the total cooling coil load in kW (assuming h 1 = 89.5 kJ/kg h_1 = 89.5\text{ kJ/kg} h 1 = 89.5 kJ/kg and h 2 = 42.0 kJ/kg h_2 = 42.0\text{ kJ/kg} h 2 = 42.0 kJ/kg ). +-----------------------------------------------------------------------------------------+
- | COIL SIZING & BPF CALCULATION STEPS |
- | |
- | STEP 1: Calculate Off-Coil Dry Bulb Temperature T2 |
- | BPF = (T2 - T_ADP) / (T1 - T_ADP) |
- | 0.15 = (T2 - 10) / (38 - 10) |
- | 0.15 * 28 = T2 - 10 ===> 4.20 = T2 - 10 ===> T2 = 14.2 deg C |
- | |
- | STEP 2: Calculate Coil Cooling Load |
- | Q_coil = m_dot_a * (h1 - h2) |
- | Q_coil = 1.5 kg/s * (89.5 - 42.0 kJ/kg) |
- | Q_coil = 1.5 kg/s * 47.5 kJ/kg = 71.25 kW |
- | Tonnage = 71.25 kW / 3.517 kW/TR = 20.26 TR |
- +-----------------------------------------------------------------------------------------+