11.2 Fresh Water Generators (Evaporators) & Heat Exchangers

DG Shipping General Purpose Rating Final Exam India

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction to Shipping, Ship Structure & Organization

1.1 Maritime Trade, Ship Types & Principal Dimensions 1.2 Shipboard Organization, Ranks & Trainee GP Rating Duties 1.3 Hull Structure, Compartments & Watertight Openings 1.4 Computer Operation, Shipboard IT Systems & Digital Basics

2 Chapter 2: Navigation Basics, Bridge Equipment & Watchkeeping

2.1 Bridge Layout, Compass, Helmsman Duties & Steering Orders 2.2 Lookout Duties, Night Vision & STCW Bridge Watchkeeping 2.3 IALA Maritime Buoyage System (Region A) & Basic COLREGs Lights/Shapes

3 Chapter 3: Anchor Work, Mooring Operations & Tug Safety

3.1 Ground Tackle: Anchors, Cables, Windlass & Hawse Pipe 3.2 Mooring Equipment, Lines & Deck Fittings 3.3 Mooring & Unmooring Operations, Snap-Back Zones & Tug Safety

4 Chapter 4: Cargo Handling Gear, Stowage & Hold Maintenance

4.1 Cargo Handling Appliances: Derricks, Cranes & Safe Working Load (SWL) 4.2 Cargo Hold Preparation, Dunnage & Hold Cleaning 4.3 Container Cargo, Bulk Cargoes & IMDG Code Awareness

5 Chapter 5: Seamanship, Ropes, Rigging & Deck Maintenance

5.1 Natural, Synthetic & Wire Ropes: Care, Coiling & Splicing 5.2 Seamanship Knots, Bends, Hitches & Block/Tackle Rigging 5.3 Deck Maintenance: Chipping, Wire-Brushing, Painting & Working Aloft/Overside

6 Chapter 6: Shipboard Safety, Safe Working Practices & Permits

6.1 Personal Protective Equipment (PPE) & Risk Assessment Onboard 6.2 Permit to Work Systems & Enclosed Space Entry 6.3 Hot Work Precautions, Electrical Safety on Deck & Gangway Watch

7 Chapter 7: STCW Basic Safety, Firefighting & Life Saving Appliances

7.1 Life-Saving Appliances: Lifejackets, Immersion Suits & Lifebuoys 7.2 Survival Craft: Lifeboats, Liferafts & Launching Appliances 7.3 Basic Firefighting Principles, Fire Triangle & Portable Extinguishers 7.4 Elementary First Aid, CPR, Bleeding Control & Medical Emergency Response

8 Chapter 8: Marine Pollution Prevention & MARPOL Regulations

8.1 MARPOL Overview & Annex I: Oil Pollution Prevention 8.2 MARPOL Annex V: Garbage Management & Shipboard Waste 8.3 Bunkering Procedures, SOPEP & Spill Response

9 Chapter 9: Engine Room Familiarization, Watchkeeping & Safety

9.1 Engine Room Layout, Bilges, Tank Tops & Trainee Ratings Duties 9.2 Engine Room Instrumentation, Alarms & Emergency Escapes 9.3 Quick-Closing Valves, Emergency Stops & Fire Dampers

10 Chapter 10: Marine Diesel Engines: Cycles, Components & Systems

10.1 Two-Stroke & Four-Stroke Marine Diesel Operating Principles 10.2 Main Engine Structural Components & Moving Parts 10.3 Engine Support Systems: Fuel Oil, Lubricating Oil & Starting Air 10.4 Engine Cooling Water Systems & Scavenge Fires

11 Chapter 11: Marine Auxiliary Machinery, Heat Exchangers & Boilers

11.1 Air Compressors, Compressed Air Receivers & Centrifugal Purifiers 11.2 Fresh Water Generators (Evaporators) & Heat Exchangers 11.3 Marine Boilers, Exhaust Gas Economizers & Steam Systems 11.4 Domestic Services, Refrigeration, Air Conditioning & Sewage Treatment

12 Chapter 12: Marine Pumps, Piping Systems, Valves & Steering Gear

12.1 Centrifugal & Positive Displacement Marine Pumps 12.2 Valves, Filters, Strainers & Pipeline Identification 12.3 Bilge, Ballast & Oily Water Separator (OWS) Systems 12.4 Steering Gear Systems & Emergency Steering Procedures 12.5 Shipboard Plumbing Repairs, Pipe Clamping & Pipeline Maintenance

13 Chapter 13: Workshop Tools, Fitting, Hot Work & Electrical Safety

13.1 Workshop Hand Tools, Fitting Practices & Precision Measurement 13.2 Power Tools, Grinding, Drilling & Safe Workshop Operations 13.3 Gas Welding, Electric Arc Welding & Hot Work Safety 13.4 Electrical Safety, Isolation, LOTO & Hazards in Machinery Spaces 13.5 Lathe Machine Operations, Centering & Fabrication 13.6 Shipboard Carpentry, Woodworking & Cement Box Emergency Repairs

14 Chapter 14: Engine Room Firefighting, Fixed Systems & Emergency Response

14.1 Machinery Space Fire Hazards & Flammable Liquids Management 14.2 Fixed Fire-Extinguishing Systems: CO2, Water Mist & Hi-Expansion Foam 14.3 Emergency Procedures: Blackout, Flooding, Abandon Ship & Engine Room Safety Drills

11.2 Fresh Water Generators (Evaporators) & Heat Exchangers

Key Takeaways Explain This Topic AI

A vacuum lets jacket-water heat evaporate seawater at low temperature. Boiling at about 40–45°C requires roughly 0.074–0.096 bar absolute pressure, about 91–93% vacuum relative to normal atmospheric pressure.

The demister mesh prevents carryover of saline seawater mist, ensuring distillate purity before the steam condenses on seawater-cooled tubes or plates.

The salinometer monitors distillate conductivity. If salinity exceeds the approved alarm setting, a divert valve keeps off-spec water out of the fresh-water tanks;10 ppm can be used as a setting example.

Plate heat exchangers provide high thermal efficiency and compact dimensions using corrugated titanium or stainless steel plates with double-seal elastomer gaskets.

Shell-and-tube heat exchangers incorporate sacrificial zinc anodes inside seawater water boxes to mitigate galvanic corrosion of copper-nickel tubes and tube sheets.

Last updated: November 2026

11.2 Fresh Water Generators (Evaporators) & Heat Exchangers

Fresh water is essential aboard sea-going merchant vessels for engine cooling systems, steam boiler feed water, and domestic crew consumption (drinking, cooking, showers, and sanitation). Carrying thousands of tonnes of fresh water in structural tanks would drastically reduce cargo deadweight capacity. Merchant ships overcome this by producing their own high-purity fresh water using vacuum fresh water generators (evaporators) powered entirely by waste heat from the main propulsion engine. In parallel, marine heat exchangers manage thermal equilibrium across engine cooling, lubricating oil, and fuel systems.

  • 1. Fresh Water Generator (Vacuum Evaporator)
  • The Thermodynamics of Low-Temperature Evaporation

At standard atmospheric pressure ( 1.013 bar 1.013\text{ bar} 1.013 bar or 101.3 kPa 101.3\text{ kPa} 101.3 kPa ), water boils at 100 ∘ C 100^\circ\text{C} 10 0 ∘ C . Lowering absolute pressure lowers the boiling point, allowing water to boil well below this temperature. +-------------------------------------------------------------------------+

  • | PRESSURE VS. BOILING POINT OF WATER |
  • +------------------------------------+------------------------------------+
  • | Absolute Pressure inside Chamber | Approximate Water Boiling Point |
  • +------------------------------------+------------------------------------+
  • | 1.013 bar (Atmospheric Pressure) | 100°C |
  • | 0.500 bar | 81°C |
  • | 0.200 bar | 60°C |
  • | 0.074 bar (about 93% vacuum) | 40°C |
  • | 0.096 bar (about 91% vacuum) | 45°C |
  • +------------------------------------+------------------------------------+

A vacuum evaporator reduces absolute pressure so that jacket-water heat can boil the feed. At 40 ∘ C 40^\circ\text{C} 4 0 ∘ C , water's saturation pressure is about 0.074 bar absolute 0.074\text{ bar absolute} 0.074 bar absolute ; at 45 ∘ C 45^\circ\text{C} 4 5 ∘ C , it is about 0.096 bar absolute 0.096\text{ bar absolute} 0.096 bar absolute . Relative to atmospheric pressure of 1.013 bar 1.013\text{ bar} 1.013 bar , these correspond to about 93 % 93\% 93% and 91 % 91\% 91% vacuum respectively. Percentage vacuum is 100 ( 1 − P a b s / P a t m ) 100(1-P_{abs}/P_{atm}) 100 ( 1 − P ab s ​ / P a t m ​ ) . Read the plant's actual pressure and temperature together.

This low boiling temperature provides two decisive advantages:

Zero Fuel Consumption : Seawater can be boiled using waste thermal energy extracted from main engine jacket cooling water ( 80 ∘ C– 85 ∘ C 80^\circ\text{C}\text{--}85^\circ\text{C} 8 0 ∘ C – 8 5 ∘ C supply, leaving at 70 ∘ C– 75 ∘ C 70^\circ\text{C}\text{--}75^\circ\text{C} 7 0 ∘ C – 7 5 ∘ C ), requiring no auxiliary boiler steam while underway.

Reduced Scale Formation : Low-temperature operation helps limit scaling, but concentration of salts in the brine still matters. Maintain the specified feed-to-production ratio, brine extraction and approved antiscalant dose; low boiling temperature alone does not prevent deposits on the heating surfaces. VACUUM FRESH WATER GENERATOR: SEPARATE FLUID PATHS

  • HEATING SIDE
  • ME jacket water ----> Evaporator heating passages ----> Jacket-water return
  • | Heat crosses metal plates
  • v
  • SEAWATER / BRINE SIDE
  • Feed seawater ------> Boiling chamber ----> Concentrated brine
  • | |
  • | Vapour rises v
  • v Combined brine/air ejector
  • Demister pad | ^
  • | | v | Air/gases
  • | +-- Brine droplets Vacuum chamber
  • | fall to chamber
  • v
  • Condenser vapour side ----> Distillate collection
  • ^ |
  • | Heat crosses plates v
  • COOLING SIDE Distillate pump
  • Seawater pump -> Condenser water side |
  • | v
  • +-> Feed and ejector water Salinometer/divert valve
  • | | |
  • v v v
  • Overboard Accepted water Reject route
  • for intended use
  • Principal Components of a Vacuum Evaporator

Combined Ejector Pump : A dedicated high-capacity centrifugal seawater pump taking suction from the sea chest. It performs two duties:

Pumps cooling seawater through the upper condenser section.

Delivers high-velocity seawater through a venturi nozzle in the air ejector and brine eductor, generating a vacuum by entraining air and gases, and continuously pumping out concentrated brine.

Evaporator Section : Located in the lower chamber; consists of a bundle of titanium plates or aluminum-brass tubes. Main engine jacket cooling water ( 80 ∘ C 80^\circ\text{C} 8 0 ∘ C ) circulates through one side, while feed seawater enters the bottom shell and boils at 40 ∘ C– 45 ∘ C 40^\circ\text{C}\text{--}45^\circ\text{C} 4 0 ∘ C – 4 5 ∘ C .

Demister Pad (Moisture Separator) : A thick mat of knitted stainless steel wire or Monel mesh mounted between the boiling chamber and condenser. Rising steam bubbles entrain tiny droplets of salty seawater (brine mist). As steam passes through the tortuous path of the demister, the heavier liquid droplets strike the wire mesh, coalesce, and drop back into the boiling chamber. Only dry, salt-free vapor passes through.

Condenser Section : Located in the upper chamber; cooled by seawater. The pure rising vapor strikes the cold condenser plates/tubes, condensing into fresh water distillate that collects in a distillate collection tray.

Distillate Extraction Pump : A small centrifugal pump that extracts pure water from the collection tray against the deep vacuum and discharges it to shipboard potable water tanks.

Feed Water Chemical Dosing Unit : Continuously injects anti-scale conditioning chemical (such as polyphosphate compounds) into the feed seawater line to further inhibit crystalline salt deposition.

Salinometer and Automatic Dump Valve

Fresh water produced for modern high-pressure marine boilers and engine cooling must contain virtually no dissolved mineral salts. Water salinity is monitored continuously by an electrical salinometer connected to a conductivity probe located in the distillate pump discharge pipe.

Principle : Pure water is a poor electrical conductor; dissolved salt ions ( N a + Na^+ N a + , C l − Cl^- C l − ) dramatically increase electrical conductivity. The salinometer measures conductivity and calibrates it into parts per million ( 1 ppm = 1 mg/L 1\text{ ppm} = 1\text{ mg/L} 1 ppm = 1 mg/L ) of sodium chloride ( N a C l NaCl N a Cl ).

Alarm Setting : Use the approved salinity limit for the plant and intended water use. The salinometer has an adjustable alarm; 10 ppm is an example set point , rather than a universal statutory boiler-feed limit. Boiler-feed acceptance also follows the boiler water-treatment specification.

3-Way Solenoid Dump Valve : If salinity exceeds the selected limit, the salinometer gives an alarm and operates the divert valve. Off-spec water goes to the installed reject route, such as the bilge or evaporator return, instead of storage. Investigate foaming, excess feed, demister displacement or condenser leakage before accepting production again. EXAMPLE: ALARM SET TO 10 ppm

  • Distillate +-------------+ Salinity <= 10 ppm +--------------------------+
  • Extraction ==| Salinometer |======================>| Fresh Water Storage Tank |
  • Pump +------+------+ +--------------------------+
  • | Salinity > 10 ppm
  • v (Alarm Triggered)
  • +-----------------------+
  • | 3-Way Solenoid Valve |=====================> [Overboard / Bilge]
  • +-----------------------+
  • Fresh Water Post-Treatment (Potable Water System)

Water produced by low-temperature distillation must be disinfected before drinking-water use. Its low salt content does not establish microbiological safety. The water also needs stabilisation because very low mineral content can make it corrosive and unpalatable. Follow the ship's approved potable-water treatment and monitoring arrangements, which can include:

Re-hardening / Mineralizer Filter : Calcium-carbonate media and other approved mineral treatment increase hardness and alkalinity, improve taste and reduce corrosivity. Check pH and treatment performance against the potable-water specification.

Ultraviolet (UV) Disinfection : An approved UV unit, commonly using 254 nm radiation, inactivates microorganisms as water passes the lamp. Lamp condition, sleeve cleanliness and correct flow matter; UV provides no disinfectant residual in the downstream pipework.

Chlorination Unit : Controlled sodium-hypochlorite dosing provides disinfection and a residual that limits bacterial regrowth. A far-tap residual of 0.2–0.5 mg/L is a common operating example; dose, contact time and monitoring follow the approved water-safety plan. Keep tanks and distribution pipes hygienic and investigate abnormal results.

Warning

Avoid Polluted Feed Water : Do not produce drinking water from polluted seawater in ports, harbours or coastal waters. About 20 nautical miles 20\text{ nautical miles} 20 nautical miles offshore is a common operating guide, but pollution may extend farther. Follow the approved water-safety plan, risk assessment and maker’s instructions. Volatile chemicals can carry over, and low-temperature distillation does not replace disinfection.

2. Marine Heat Exchangers

Heat exchangers transfer thermal energy between two fluids of differing temperatures without allowing them to mix. In a ship's machinery space, they function as coolers (lubricating oil cooler, jacket water cooler, scavenge air cooler) and heaters (fuel oil heaters, feed water heaters). Modern ships primarily use two structural designs: Plate Type and Shell-and-Tube Type . PLATE HEAT EXCHANGER (PHE) SHELL-AND-TUBE HEAT EXCHANGER

  • Fixed Frame Tightening Bolts Tube Bundle Inside Cylindrical Shell
  • | | +--------------------------------+
  • v v |===Seawater In======+ |
  • +----+ +--+ +--+ +--+ +----+ | |--------------| | |
  • | | | | | | | | | | | | Baffles | | Zinc |
  • | | | | | | | | | | | |--+ +--| | Anodes |
  • | | | | | | | | | | | | | | | | In Cover |
  • | | | | | | | | | | | |--------------| | |
  • +----+ +--+ +--+ +--+ +----+ |===Seawater Out=====+ |
  • ^ ^ +--------------------------------+
  • | | ^ ^
  • Fixed Plate Movable Plate | |
  • (Titanium Plates & Gaskets) Hot Oil In Cool Oil Out
  • 1. Plate-Type Heat Exchangers (PHE)

Plate heat exchangers consist of a pack of thin, corrugated metal plates held between a stationary frame plate and a movable pressure plate by high-tensile steel tightening bolts.

Plate Metallurgy : Made of pressed titanium for seawater services (impervious to saltwater corrosion and impingement attack) or AISI 316 stainless steel for fresh water and lubricating oil duties. Corrugations (chevron or herringbone patterns) create severe fluid turbulence even at low flow velocities, yielding heat transfer coefficients 3 to 5 times higher than tubular designs.

Elastomeric Gaskets : Molded Nitrile Butadiene Rubber (NBR) or EPDM gaskets are cemented or clipped into perimeter grooves on each plate. The gaskets route warm and cold fluids alternately through odd and even plate channels in a counter-flow arrangement.

Double-Gasket Safety Barrier : A double-gasket seal with atmospheric tell-tale leakage grooves is provided around nozzle ports. If an elastomer gasket fails, fluid weeps externally down the plate pack to the bilge rather than cross-contaminating the opposing fluid system.

Operational Advantage : Extremely compact (requires only one-third the space and weight of a shell-and-tube unit of equivalent heat duty); easily opened for chemical cleaning or mechanical brushing; capacity can be expanded simply by adding more plates.

Operational Cautions : Elastomer gaskets age in service. Use the approved gasket material within its specified temperature, pressure and fluid-compatibility limits. During reassembly, tightening bolts must be tightened evenly in cross-pattern to a precise manufacturer-specified dimension (known as Dimension 'A'). Over-tightening crushes and permanently deforms the corrugated plates.

2. Shell-and-Tube Heat Exchangers

Shell-and-tube heat exchangers consist of an outer cylindrical steel shell housing a longitudinal bundle of hundreds of small-diameter tubes held in place by transverse tube sheets.

Flow Mechanics : One fluid circulates through the interior of the tubes (typically corrosive seawater in modern practice), while the second fluid circulates through the shell space around the tubes (lubricating oil, jacket water, or steam). Baffle plates inside the shell force fluid to flow across the tubes in a serpentine pattern, maximizing turbulence and heat exchange.

Thermal Expansion : To prevent tube buckling caused by thermal expansion, one tube sheet is fixed securely to the shell, while the opposite end tube sheet is 'floating' (sealed with resilient O-rings) or the tubes are bent into a hairpin 'U-tube' configuration.

Sacrificial Zinc Anodes : Seawater water boxes (end covers) are made of cast iron or mild steel, while tubes are made of copper-nickel ( 70 / 30 or 90 / 10 Cu-Ni 70/30\text{ or }90/10\text{ Cu-Ni} 70/30 or 90/10 Cu-Ni ) or aluminum-brass. The electrical coupling of these dissimilar metals in electrolytic seawater induces aggressive galvanic corrosion. To protect the expensive tube sheets and tubes, replaceable zinc sacrificial anodes are threaded into the water box covers. The zinc has a more negative electrochemical potential and corrodes preferentially.

Note

GP Rating Watchkeeping Duty : During weekly auxiliary machinery inspections, GP Ratings check zinc anodes on seawater coolers. Renew an anode when more than 50 % 50\% 50% of its original metal has been consumed , or at the maker’s specified limit. Anodes must never be painted, as paint insulates the zinc and completely neutralizes galvanic protection.