Study guide
12.1 Centrifugal & Positive Displacement Marine Pumps
DG Shipping General Purpose Rating Final Exam India
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction to Shipping, Ship Structure & Organization
1.1 Maritime Trade, Ship Types & Principal Dimensions 1.2 Shipboard Organization, Ranks & Trainee GP Rating Duties 1.3 Hull Structure, Compartments & Watertight Openings 1.4 Computer Operation, Shipboard IT Systems & Digital Basics
2 Chapter 2: Navigation Basics, Bridge Equipment & Watchkeeping
2.1 Bridge Layout, Compass, Helmsman Duties & Steering Orders 2.2 Lookout Duties, Night Vision & STCW Bridge Watchkeeping 2.3 IALA Maritime Buoyage System (Region A) & Basic COLREGs Lights/Shapes
3 Chapter 3: Anchor Work, Mooring Operations & Tug Safety
3.1 Ground Tackle: Anchors, Cables, Windlass & Hawse Pipe 3.2 Mooring Equipment, Lines & Deck Fittings 3.3 Mooring & Unmooring Operations, Snap-Back Zones & Tug Safety
4 Chapter 4: Cargo Handling Gear, Stowage & Hold Maintenance
4.1 Cargo Handling Appliances: Derricks, Cranes & Safe Working Load (SWL) 4.2 Cargo Hold Preparation, Dunnage & Hold Cleaning 4.3 Container Cargo, Bulk Cargoes & IMDG Code Awareness
5 Chapter 5: Seamanship, Ropes, Rigging & Deck Maintenance
5.1 Natural, Synthetic & Wire Ropes: Care, Coiling & Splicing 5.2 Seamanship Knots, Bends, Hitches & Block/Tackle Rigging 5.3 Deck Maintenance: Chipping, Wire-Brushing, Painting & Working Aloft/Overside
6 Chapter 6: Shipboard Safety, Safe Working Practices & Permits
6.1 Personal Protective Equipment (PPE) & Risk Assessment Onboard 6.2 Permit to Work Systems & Enclosed Space Entry 6.3 Hot Work Precautions, Electrical Safety on Deck & Gangway Watch
7 Chapter 7: STCW Basic Safety, Firefighting & Life Saving Appliances
7.1 Life-Saving Appliances: Lifejackets, Immersion Suits & Lifebuoys 7.2 Survival Craft: Lifeboats, Liferafts & Launching Appliances 7.3 Basic Firefighting Principles, Fire Triangle & Portable Extinguishers 7.4 Elementary First Aid, CPR, Bleeding Control & Medical Emergency Response
8 Chapter 8: Marine Pollution Prevention & MARPOL Regulations
8.1 MARPOL Overview & Annex I: Oil Pollution Prevention 8.2 MARPOL Annex V: Garbage Management & Shipboard Waste 8.3 Bunkering Procedures, SOPEP & Spill Response
9 Chapter 9: Engine Room Familiarization, Watchkeeping & Safety
9.1 Engine Room Layout, Bilges, Tank Tops & Trainee Ratings Duties 9.2 Engine Room Instrumentation, Alarms & Emergency Escapes 9.3 Quick-Closing Valves, Emergency Stops & Fire Dampers
10 Chapter 10: Marine Diesel Engines: Cycles, Components & Systems
10.1 Two-Stroke & Four-Stroke Marine Diesel Operating Principles 10.2 Main Engine Structural Components & Moving Parts 10.3 Engine Support Systems: Fuel Oil, Lubricating Oil & Starting Air 10.4 Engine Cooling Water Systems & Scavenge Fires
11 Chapter 11: Marine Auxiliary Machinery, Heat Exchangers & Boilers
11.1 Air Compressors, Compressed Air Receivers & Centrifugal Purifiers 11.2 Fresh Water Generators (Evaporators) & Heat Exchangers 11.3 Marine Boilers, Exhaust Gas Economizers & Steam Systems 11.4 Domestic Services, Refrigeration, Air Conditioning & Sewage Treatment
12 Chapter 12: Marine Pumps, Piping Systems, Valves & Steering Gear
12.1 Centrifugal & Positive Displacement Marine Pumps 12.2 Valves, Filters, Strainers & Pipeline Identification 12.3 Bilge, Ballast & Oily Water Separator (OWS) Systems 12.4 Steering Gear Systems & Emergency Steering Procedures 12.5 Shipboard Plumbing Repairs, Pipe Clamping & Pipeline Maintenance
13 Chapter 13: Workshop Tools, Fitting, Hot Work & Electrical Safety
13.1 Workshop Hand Tools, Fitting Practices & Precision Measurement 13.2 Power Tools, Grinding, Drilling & Safe Workshop Operations 13.3 Gas Welding, Electric Arc Welding & Hot Work Safety 13.4 Electrical Safety, Isolation, LOTO & Hazards in Machinery Spaces 13.5 Lathe Machine Operations, Centering & Fabrication 13.6 Shipboard Carpentry, Woodworking & Cement Box Emergency Repairs
14 Chapter 14: Engine Room Firefighting, Fixed Systems & Emergency Response
14.1 Machinery Space Fire Hazards & Flammable Liquids Management 14.2 Fixed Fire-Extinguishing Systems: CO2, Water Mist & Hi-Expansion Foam 14.3 Emergency Procedures: Blackout, Flooding, Abandon Ship & Engine Room Safety Drills
12.1 Centrifugal & Positive Displacement Marine Pumps
Key Takeaways Explain This Topic AI
A centrifugal impeller adds energy to the liquid, and the volute converts part of its velocity energy into pressure. Pump head comes from the pump curve; flow generally decreases as system back-pressure increases.
Centrifugal pumps are not inherently self-priming because the low density of air generates only a small pressure difference at the impeller eye, requiring priming via central vacuum units, compressed air ejectors, or positive gravity suction from sea chests.
For a typical radial-flow centrifugal pump, a closed or throttled discharge can reduce hydraulic load during acceleration. Follow the maker’s starting and minimum-flow instructions, then open gradually to the required duty; initial motor inrush still occurs.
Renewable casing wear rings maintain a critical running clearance gap of 0.2 – 0.4 mm 0.2\text{--}0.4\text{ mm} 0.2 – 0.4 mm to prevent high-pressure discharge liquid from recirculating back to the low-pressure suction eye.
Positive displacement pumps (gear, screw, reciprocating, rotary vane) displace a fixed liquid volume per cycle and must NEVER be operated against a closed discharge valve; they require suitable internal or external pressure relief to prevent catastrophic overpressurization.
Last updated: November 2026
12.1 Centrifugal & Positive Displacement Marine Pumps
Marine pumps are the mechanical workhorses of a merchant vessel's engine room and deck systems. They circulate sea water and fresh water for main engine cooling, transfer combustible fuel oils from bunker tanks to service systems, deliver pressurized lubricating oil to spinning journal bearings, pump out oily bilge accumulations, and transfer thousands of tonnes of ballast water to maintain ship stability. Trainee General Purpose (GP) Ratings must master the two fundamental classifications of marine pumps— Centrifugal (Roto-dynamic) and Positive Displacement (PD) pumps—understanding their distinct operating principles, internal construction, sealing methods, starting procedures, and critical safety rules.
1. Centrifugal Marine Pumps
Centrifugal pumps belong to the roto-dynamic category. They are widely used aboard merchant vessels for high-volume, low-to-medium pressure applications such as main sea water cooling, low-temperature (LT) fresh water circulating, ballast handling, fire main pressurization, and general service. +------------------------+
- | Discharge Flange |
- | (High Static Pressure)|
- +-----------+------------+
- ^
- / \ Spiral Volute Casing
- / \ (Converts Velocity Head
- / * \ into Pressure Head)
- / *** \
- +--------------------+ | ***** |
- | Suction Flange |--->| ( O ) | (Rotating Impeller)
- | (Low Pressure Eye) | | ***** |
- +--------------------+ \ *** /
- \ * /
- \ /
- \ /
- +
- Operating Principle and Hydrodynamics
Kinetic Energy Impartation : Fluid enters the pump horizontally through the suction branch and reaches the central impeller eye . As the electric motor spins the impeller at high speed (typically 1,450 to 1,750 RPM or 2,950 RPM), the curved impeller vanes throw the liquid radially outwards by centrifugal force, imparting high velocity (kinetic energy).
Velocity to Pressure Conversion : The liquid discharges from the impeller tips into the surrounding spiral volute casing . The cross-sectional flow area of the volute gradually expands towards the discharge nozzle. According to Bernoulli's principle of fluid dynamics, as the cross-sectional area increases, the liquid flow velocity decreases, converting kinetic velocity head into static pressure head: H v = v 2 2 g H_v = \frac{v^2}{2g} H v = 2 g v 2 where H v H_v H v is velocity head in metres, v v v is the liquid flow velocity ( m/s \text{m/s} m/s ), and g = 9.81 m/s 2 g=9.81\text{ m/s}^2 g = 9.81 m/s 2 . This is not the total head generated by the impeller; obtain developed pump head from its characteristic curve. For comparable inlet/outlet velocities and elevations, pressure rise is approximately Δ p = ρ g H \Delta p=\rho gH Δ p = ρ g H , where ρ \rho ρ is fluid density.
Continuous Flow Generation : As liquid is thrown outwards from the center, a localized low-pressure zone (partial vacuum) forms at the impeller eye. Atmospheric pressure or liquid static head acting on the external suction reservoir continuously pushes more liquid into the eye, establishing uninterrupted flow.
Non-Positive Displacement Characteristics
Flow Varies with Back-Pressure : Unlike positive displacement pumps, a centrifugal pump does not deliver a constant volume. If system discharge resistance (back-pressure) increases, flow rate drops. If the discharge valve is closed completely, the pump reaches its shut-off head —flow falls to zero while the impeller continues rotating. Do not leave the pump dead-headed: churning heats the trapped liquid and can damage the pump. Observe the approved minimum-flow and brief-starting limits.
Lack of Inherent Self-Priming : Centrifugal pumps cannot pump air or gases. Because air has a density roughly 1 800 th \frac{1}{800}\text{th} 800 1 th that of liquid water, an air-filled impeller spinning at normal speed generates an insignificant pressure differential (insufficient to draw liquid up the suction pipe). If air enters the suction casing, the pump suffers an air lock and immediately loses suction.
Priming Devices
To operate from a suction lift (e.g., pumping bilges or drawing ballast from double bottom tanks below pump level), centrifugal pumps require auxiliary priming devices:
Positive Suction Head (Flooded Suction) : When drawing sea water from a low sea chest located well below the vessel's waterline, hydrostatic sea pressure naturally floods the pump casing without mechanical assistance.
Central Vacuum Priming System : Consists of an automated liquid-ring vacuum pump connected to the centrifugal pump casing via a float-operated suction valve. The vacuum pump exhausts air from the suction pipe and casing until liquid rises, lifts the float, and closes the vacuum line.
Air Ejector Priming : Uses compressed air passing through a convergent-divergent Venturi nozzle to create a deep suction vacuum that evacuates air from the pump casing.
Major Constructional Components
Component Material Function & Engineering Significance
Impeller Nickel-Aluminum Bronze (NAB) or Gunmetal Rotating disc with backward-curved vanes imparting kinetic energy. Three designs: Enclosed (shrouded, highest efficiency, clean liquids), Semi-open (moderate efficiency, handles suspended solids), and Open (low efficiency, slurry/dredging).
Volute Casing Cast Iron or Cast Steel Spiral housing collecting liquid and converting velocity into static pressure. Fitted with vent cocks at the top and drain plugs at the bottom.
Renewable Wear Rings Phosphor Bronze or Leaded Bronze Sacrificial rings fitted between the rotating impeller rim and stationary casing. Maintains a precision radial clearance gap of 0.2 – 0.4 mm 0.2\text{--}0.4\text{ mm} 0.2 – 0.4 mm to prevent high-pressure discharge liquid from recirculating back to the suction eye. Measure clearance during overhaul and renew rings at the maker’s wear limit or when excessive internal leakage has reduced pump performance.
Shaft Sleeve Stainless Steel or Hard Chrome-Plated Bronze Replaceable cylindrical sleeve fitted over the pump shaft in the stuffing box zone to protect the main shaft against abrasive wear, friction heat, and corrosion.
Bearing Housing Cast Iron with Ball / Roller Bearings Supports the rotating shaft assembly, carrying radial and axial thrust loads. Lubricated by lithium grease or an oil bath with sight glass.
Shaft Sealing: Stuffing Box Gland Packing vs. Mechanical Seal
Where the rotating drive shaft penetrates the stationary pump casing, high-integrity sealing is mandatory to prevent liquid leaking out (or air drawing in under suction lift). STUFFING BOX GLAND PACKING MECHANICAL SEAL
- +-------------------------------+ +-------------------------------+
- | Casing Wall | | Casing Wall |
- | [===] [===] [===] Gland | | Stationary Seal Ring |
- | Packings (Cotton/Graphite) | | (Silicon Carbide/Ceramic) |
- | --------------------------- | | || Rotating Ring (Carbon) |
- | ===> Controlled cooling drip | | || [Spring Compression] |
- | Shaft Sleeve | | --------------------------- |
- |===============================| | Zero Visible Leakage |
- +-------------------------------+ +-------------------------------+
Stuffing Box Gland Packing :
Construction : Annular chamber packed with braided square rings of cotton, flax, or synthetic fibers impregnated with graphite and PTFE lubricants. Rings are cut with ends beveled at 45 ∘ 45^\circ 4 5 ∘ and staggered at 90 ∘ 90^\circ 9 0 ∘ or 120 ∘ 120^\circ 12 0 ∘ offsets around the shaft.
Operational Rule : The gland follower must never be overtightened. A controlled, steady cooling drip of 10 to 20 drops per minute must leak past the packing while running. This fluid leakage lubricates the interface and carries away friction heat. Overtightening burns and glazes the packing, scores the shaft sleeve, and overloads the electric motor.
Mechanical Seal :
Construction : Consists of two ultra-flat mating faces: a stationary face (silicon carbide or ceramic) mounted in the casing with an elastomeric O-ring, and a rotating face (carbon graphite) mounted on the shaft sleeve and pressed firmly against the stationary face by stainless steel coil springs.
Operational Rule : Provides complete sealing with zero visible leakage. However, mechanical seals are brittle and must never be run dry . Even a few seconds of dry running destroys the micro-thin liquid lubricating film between the faces, causing instantaneous friction overheating, thermal cracking, and catastrophic seal failure.
Operating Protocol for Centrifugal Pumps
Pre-Starting Checks :
Verify the pump shaft rotates freely by hand (turn the shaft coupling with motor power isolated).
Check bearing lubrication oil level in the sight glass or verify grease cup replenishment.
Fully open the pump suction valve .
Open the top casing vent cock until air is completely expelled and a steady stream of liquid emerges; close the vent cock.
Starting Sequence (Typical Radial-Flow Pump; Confirm Maker Instructions) :
Set the discharge valve to the approved starting position , commonly closed or throttled for a radial-flow pump. Maintain any required minimum-flow bypass.
Press the motor start button on the starter panel. Monitor the starting current (ammeter needle will surge then settle down).
Observe the discharge pressure gauge. The pressure will quickly rise to the pump's shut-off head.
Slowly open the discharge valve to the required duty , checking operating pressure, flow and motor current. Do not assume fully open is the correct running position.
Why use a throttled start? A typical radial-flow pump requires less shaft power at low flow, reducing hydraulic load while the motor accelerates. This does not remove the motor’s initial electrical inrush. Gradual valve adjustment controls the rise in flow; follow the approved procedure to avoid pressure surges and prolonged zero-flow operation.
Stopping Sequence :
Slowly close the discharge valve completely.
Press the stop button to de-energize the electric motor.
Close the suction valve only if the pump is being isolated for maintenance or inspection.
2. Positive Displacement (PD) Marine Pumps
Positive displacement pumps operate on an entirely different mechanical principle. Instead of imparting velocity, they trap a fixed, discrete volume of fluid inside a contracting chamber and mechanically force it into the discharge pipe against whatever resistance exists. ROTARY GEAR PUMP RECIPROCATING PLUNGER PUMP
- +-----------------------+ +-----------------------+
- | Discharge | | Discharge |
- | ^ | | (NRV Lifts) |
- | /----|----\ | | ^ |
- | ( ####### ) | | [====]===] |
- | ( Drive ) | | Cylinder |
- | ( Gear ) | | [=========] |
- | \ / | | ( Plunger ) |
- | ( Idler ) | | | |
- | ( Gear ) | | V |
- | \-------/ | | Suction |
- | ^ | | (NRV Lifts) |
- | Suction | +-----------------------+
- +-----------------------+
- Operating Characteristics
Constant Volumetric Delivery : The discharge flow rate is directly proportional to rotational or reciprocating speed, remaining virtually constant regardless of whether discharge back-pressure is 2 bar or 50 bar.
Self-Priming Capability : Because the moving elements (gears, screws, pistons, vanes) maintain tight mechanical tolerances within the casing, they effectively evacuate air and gases from the suction piping, creating a deep suction vacuum without requiring external priming devices.
High Viscosity Handling : Exceptionally well-suited for high-viscosity liquids such as Heavy Fuel Oil (HFO), Marine Diesel Oil (MDO), cylinder lubricating oil, sludge, and hydraulic oil.
Major Classifications of Marine Positive Displacement Pumps
Gear Pumps :
Mechanism : Composed of two intermeshing precision gears—a motor-driven driver gear and an idler gear —enclosed inside a close-fitting casing. Liquid enters the suction branch, fills the cavities between the unmeshing gear teeth and the casing wall, is carried around the outer perimeter of both gears, and is squeezed out into the discharge branch as the teeth mesh together on the opposite side.
Applications : Fuel oil transfer pumps, auxiliary boiler fuel booster pumps, lubricating oil supply, and hydraulic steering power units.
Screw Pumps :
Mechanism : Intermeshing helical screws form sealed chambers that move liquid axially from suction to discharge. A common three-screw unit has one driven power rotor and two idler screws inside a close-fitting liner. Single-flow units move liquid along the screws in one direction; double-flow arrangements feed from both ends towards a central discharge.
Applications : Main engine lubricating oil supply pumps and fuel oil high-pressure supply systems. Screw pumps provide exceptionally smooth, non-pulsating, pulse-free flow, low noise levels, and high suction lift capability.
Reciprocating Pumps :
Mechanism : Employs a reciprocating piston or plunger driven back and forth inside a cylinder by an electric motor via a crankshaft or directly by steam. Fitted with spring-loaded suction and discharge non-return check valves. On the outward suction stroke, cylinder pressure drops, the suction valve lifts, and liquid enters. On the inward discharge stroke, the suction valve snaps shut, the discharge valve lifts, and liquid is forced into the system.
Applications : Marine auxiliary boiler feed water pumps, double-bottom tank stripping pumps, and high-pressure bilge stripping.
Rotary Vane Pumps :
Mechanism : An eccentrically mounted rotor containing radial slots fitted with sliding rectangular vanes rotates inside a circular cam ring. Centrifugal force and springs push the vanes outward against the casing wall. Fluid is drawn into expanding crescent-shaped pockets on the suction side and forced out through contracting pockets on the discharge side.
Applications : Hydraulic steering gear servo control pumps, lube oil priming, and fuel transfer units.
Centrifugal versus Positive Displacement Comparison
Technical Feature Centrifugal Pump Positive Displacement (PD) Pump
Flow vs. Pressure Flow decreases as discharge back-pressure increases; reaches zero flow at shut-off head Flow remains virtually constant regardless of discharge back-pressure
Self-Priming Not self-priming; requires flooded suction or external vacuum/ejector priming Inherent self-priming; efficiently evacuates air from suction lines
Fluid Viscosity Best suited for low-viscosity fluids (sea water, fresh water); efficiency collapses on thick oils Ideal for medium to high-viscosity fluids (heavy fuel oil, lube oil, sludge)
Discharge Flow Pattern Continuous, completely steady, pulse-free flow Continuous (screw/gear) or pulsating (reciprocating plunger/piston)
Starting Procedure Typical radial pump: maker-approved closed/throttled start, then adjust to duty Must start with discharge valve OPEN to prevent catastrophic overpressurization
3. Critical Safety Rule for Positive Displacement Pumps
Caution
NEVER start or operate a Positive Displacement Pump against a closed discharge valve! Because a positive displacement pump delivers a fixed volume of liquid on every cycle regardless of system back-pressure, operating against a closed or obstructed discharge valve causes hydraulic pressure to skyrocket within milliseconds towards theoretically infinite levels. This will result in: (1) catastrophic fracture or explosion of the pump casing, (2) ruptured discharge piping and sheared flanges, (3) sheared pump drive shafts or destroyed gears, and (4) electrical burnout of the drive motor.
Pressure Relief Protection
To safeguard machinery and crew against accidental overpressurization, provide a suitable internal or external pressure relief valve . Marine class rules require the valve on the pump casing or delivery pipe before the first stop valve where pump pressure can exceed the rated value.
Relief Operation : The valve is calibrated to lift at a predetermined safe margin (typically 10% to 15% above normal working pressure).
Recirculation Path : When the relief valve opens, excess liquid is safely bypassed directly back to the pump suction chamber or returns to the storage tank, relieving overpressure and preventing mechanical explosion.