1 Chapter 1: Exam Orientation & Trade Mathematics
1.1 Exam Format, Prov Testing Policies & Code References 1.2 Navigating the 2006 IPC & 2012 Indiana Amendments 1.3 Trade Math: Slopes, Head Pressure, Volumes & Fitting Allowances
2 Chapter 2: General Regulations, Structural Safety & Supports
2.1 Piping Protection, Corrosion, Freezing & Sleeving 2.2 Structural Safety: Cutting, Notching & Boring in Joists and Studs 2.3 Pipe Hangers, Brackets, Anchoring & Support Spacing
3 Chapter 3: Plumbing Fixtures, Faucets & Accessibility
3.1 Minimum Plumbing Facilities & Fixture Count Sizing 3.2 Water Closets, Urinals & Flushometer Sizing 3.3 Lavatories, Showers, Bathtubs & Scald Prevention (ASSE 1016/1017)
4 Chapter 4: Traps, Interceptors & Indirect Waste
4.1 Trap Design, Liquid Seal Protection, Primers & Prohibited Traps 4.2 Grease Interceptors, Oil Separators & Sand Traps 4.3 Indirect Waste, Air Gaps, Air Breaks & Food Preparation Waste
5 Chapter 5: Sanitary Drainage: Sizing, Slopes & Materials
5.1 Drainage Fixture Units (DFU) & Horizontal Branch Sizing 5.2 Building Drain & Building Sewer Sizing, Slopes & Velocities 5.3 Drainage Pipe Materials, Solvent Cementing & Mechanical Joints
6 Chapter 6: Sanitary Drainage: Cleanouts, Sumps & Testing
6.1 Cleanout Locations, Sizing, Clearances & Accessibility 6.2 Drainage Sumps, Sewage Ejectors & Backwater Valves 6.3 Drainage System Inspection & Testing (Water, Air & Smoke)
7 Chapter 7: Vents: Principles, Stacks & Terminals
7.1 DWV Venting Principles, Hydraulic Gradients & Trap Protection 7.2 Individual, Common & Relief Vents 7.3 Vent Terminals, Roof Extensions & Frost Closure (IPC Section 904) 7.4 Vent Stacks, Stack Vents, Vent Headers & Waste Stack Vents
8 Chapter 8: Vents: Advanced Systems & Special Venting
8.1 Horizontal & Vertical Wet Venting Systems 8.2 Circuit Venting & Loop Venting Systems 8.3 Combination Waste and Vent Systems & Island Fixture Venting 8.4 Air Admittance Valves (AAVs) & Installation Limits 8.5 Vent Pipe Sizing: Table 916.1, Section 916.2 & Developed Length
9 Chapter 9: Water Supply: Sizing, Distribution & Materials
9.1 Water Service Sizing, Street Pressure & Pressure Regulators 9.2 Water Supply Fixture Units (WSFU) & Pipe Sizing Tables 9.3 Water Distribution Materials, Copper Joining & PEX Systems 9.4 Water Hammer Arrestors & Thermal Expansion Control
10 Chapter 10: Backflow Prevention & Cross-Connection Control
10.1 Cross-Connection Hazards, Backpressure & Backsiphonage 10.2 Backflow Prevention Assemblies: RPZ, DCVA, PVB & Vacuum Breakers 10.3 Containment vs. Isolation, Installation Clearances & Testing
11 Chapter 11: Water Heaters: Sizing, Combustion & Safety
11.1 Water Heater Sizing, Clearances, Drain Pans & Elevation in Garages 11.2 Temperature and Pressure (T&P) Relief Valves & Discharge Piping 11.3 Combustion Air, Draft Hoods & Venting of Fuel-Fired Water Heaters
12 Chapter 12: Storm Drainage Systems & Roof Drainage
12.1 Indiana Rainfall Rates, Projected Roof Area & Roof Drain Sizing 12.2 Vertical Conductors, Downspouts & Horizontal Storm Drains 12.3 Subsoil Drains, Sump Pumps & Secondary Emergency Overflows
13 Chapter 13: Developed Length, Isometric Analysis & Offset Math
13.1 Reading Plumbing Blueprints, Symbols & DWV Riser Diagrams 13.2 Isometric Drawing Interpretation & Three-Dimensional Layouts 13.3 Developed Length Calculations, 45-Degree Offsets & Rolling Offsets
14 Chapter 14: Indiana Plumbing Laws, Rules, Code Amendments & Business
14.1 Indiana Plumbing Commission (IC 25-28.5) & Licensing Standards 14.2 Key Indiana Amendments to the 2006 IPC (675 IAC 16-1.4) 14.3 Plumbing Permits, Local Administrative Rules & Inspections 14.4 Plumbing Business, OSHA Safety & Project Management Fundamentals
1.3 Trade Math: Slopes, Head Pressure, Volumes & Fitting Allowances
Key Takeaways Explain This Topic AI
Total pipe fall is calculated using the formula Fall (inches) = Slope (inches per foot) × Run (feet); an 80-foot sewer line pitched at 1/4 inch per foot drops exactly 20 inches.
Hydrostatic water column pressure generates 0.433 psi per vertical foot of head, and conversely, 1.0 psi of pressure supports a column of water 2.31 feet high.
Cylindrical volume is calculated using V = π × r² × L or V = 0.7854 × D² × L; converting cubic feet to gallons requires multiplying by 7.48 gallons per cubic foot.
Water weighs 8.34 pounds per gallon (62.4 pounds per cubic foot), a fundamental constant used for calculating filled piping loads and storage vessel structural supports.
Accurate cut pipe lengths require calculating fitting allowances (takeoffs) by subtracting the distance from the fitting center to the pipe stop from the overall center-to-center measurement.
Last updated: September 2026
1.3 Trade Math: Slopes, Head Pressure, Volumes & Fitting Allowances
Core Principle: Mathematical competency is essential for every licensed journeyman plumber. The Indiana licensing examination tests real-world trade calculations: establishing uniform drainage fall, verifying invert elevations, determining static water head pressures on DWV test columns, sizing water heater storage capacities, and calculating fitting takeoffs for precise pipe fabrication.
Drainage Grade, Slope & Fall Calculations
Horizontal sanitary and storm drainage piping must be installed at a uniform downward slope to maintain a self-cleansing velocity (typically 2 feet per second). If a drain is installed too flat, solids will settle and cause stoppages; if installed too steep, liquids may flow away from solids in low-flow fixtures. +-------------------------------------------------------------------------+
- | THE DRAINAGE FALL TRIANGLE |
- | |
- | Total Fall (inches) |
- | --------------------------- |
- | Slope (in/ft) x Run (ft) |
- | |
- | - Fall (inches) = Slope (inches per foot) x Run (feet) |
- | - Slope (in/ft) = Fall (inches) / Run (feet) |
- | - Run (feet) = Fall (inches) / Slope (inches per foot) |
- +-------------------------------------------------------------------------+
- Standard Code Slope Requirements (2006 IPC Section 704.1)
Pipes 2-1/2 inches or smaller: Minimum slope of 1/4 inch per foot (2.08% grade).
Pipes 3 inches to 6 inches: Minimum slope of 1/8 inch per foot (1.04% grade).
Pipes 8 inches or larger: Minimum slope of 1/16 inch per foot (0.52% grade).
Invert Elevation Calculations
The invert elevation represents the absolute elevation of the inside bottom of a pipe channel. Invert calculations ensure that building sewers align correctly with municipal sewer taps or septic tank inlet baffles: Downstream Invert Elevation = Upstream Invert Elevation − Total Fall \text{Downstream Invert Elevation} = \text{Upstream Invert Elevation} - \text{Total Fall} Downstream Invert Elevation = Upstream Invert Elevation − Total Fall Upstream Invert Elevation = Downstream Invert Elevation + Total Fall \text{Upstream Invert Elevation} = \text{Downstream Invert Elevation} + \text{Total Fall} Upstream Invert Elevation = Downstream Invert Elevation + Total Fall
(Note: Ensure elevations and fall are expressed in identical units—either all inches or all feet—before performing addition or subtraction).
Worked Example 1: Total Fall of a Building Sewer
Problem: A plumber is installing an 88-foot horizontal run of 4-inch building sewer from the foundation wall to the municipal tap. The code requires a minimum slope of 1/8 inch per foot. What is the total vertical fall across the run?
Step 1: Identify given variables.
Run = 88 feet \text{Run} = 88\text{ feet} Run = 88 feet
Slope = 1 / 8 inch per foot = 0.125 in/ft \text{Slope} = 1/8\text{ inch per foot} = 0.125\text{ in/ft} Slope = 1/8 inch per foot = 0.125 in/ft
Step 2: Apply the fall formula. Fall = 0.125 in/ft × 88 ft = 11.0 inches \text{Fall} = 0.125\text{ in/ft} \times 88\text{ ft} = 11.0\text{ inches} Fall = 0.125 in/ft × 88 ft = 11.0 inches
Result: The total vertical fall is 11 inches .
Worked Example 2: Determining Invert Elevation
Problem: In the installation above, the upstream invert elevation at the building foundation is established at 102.50 feet above sea level benchmark. What is the finishing invert elevation at the property line connection 88 feet downstream?
Step 1: Convert total fall to feet. Fall in feet = 11.0 inches 12 inches per foot = 0.9167 feet \text{Fall in feet} = \frac{11.0\text{ inches}}{12\text{ inches per foot}} = 0.9167\text{ feet} Fall in feet = 12 inches per foot 11.0 inches = 0.9167 feet
Step 2: Subtract fall from upstream invert. Downstream Invert = 102.50 ft − 0.9167 ft = 101.5833 ft \text{Downstream Invert} = 102.50\text{ ft} - 0.9167\text{ ft} = 101.5833\text{ ft} Downstream Invert = 102.50 ft − 0.9167 ft = 101.5833 ft
Result: The downstream invert elevation is 101.58 feet (or 101 feet, 7 inches).
Hydrostatic Pressure and Water Head Calculations
Water exerts pressure due to its physical weight. A column of water creates downward force directly proportional to its vertical height, independent of the pipe diameter or the shape of the container. +-------------------------------------------------------------------------+
- | HYDROSTATIC PRESSURE & HEAD CONVERSIONS |
- +-------------------------------------------------------------------------+
- | Density of fresh water | 62.4 pounds per cubic foot (lbs/cu ft) |
- | Base area of 1-ft column | 144 square inches (12" x 12") |
- | Unit column pressure | 62.4 lbs / 144 sq in = 0.4333 psi per foot |
- | Reciprocal head factor | 1.0 psi / 0.4333 = 2.31 feet of water head |
- +-------------------------------------------------------------------------+
Core Formulas Pressure (psi) = Head (feet) × 0.433 psi/ft \text{Pressure (psi)} = \text{Head (feet)} \times 0.433\text{ psi/ft} Pressure (psi) = Head (feet) × 0.433 psi/ft Head (feet) = Pressure (psi) × 2.31 ft/psi ( or Pressure 0.433 ) \text{Head (feet)} = \text{Pressure (psi)} \times 2.31\text{ ft/psi} \quad \left(\text{or } \frac{\text{Pressure}}{0.433}\right) Head (feet) = Pressure (psi) × 2.31 ft/psi ( or 0.433 Pressure )
Code Applications
Rough-In Water Head Testing (Section 312.2): Sanitary drainage systems must withstand a 10-foot head of water during rough-in inspection. The pressure at the bottom of the section under test is: Test Pressure = 10 ft × 0.433 psi/ft = 4.33 psi \text{Test Pressure} = 10\text{ ft} \times 0.433\text{ psi/ft} = 4.33\text{ psi} Test Pressure = 10 ft × 0.433 psi/ft = 4.33 psi
Riser Pressure Loss: For domestic water risers in multistory buildings, static water pressure decreases by 0.433 psi for every 1 vertical foot of rise (or 4.33 psi per 10 feet of elevation gain).
Worked Example 3: Finding Static Pressure at Upper-Floor Fixtures
Problem: A commercial building has a street water main pressure of 72.0 psi measured at the ground-level water meter (Elevation 0 ft). Disregarding friction loss, what is the available static pressure at a flushometer valve located on the third floor, 34 feet above the meter?
Step 1: Calculate elevation head pressure loss. Pressure Loss = 34 ft × 0.433 psi/ft = 14.722 psi \text{Pressure Loss} = 34\text{ ft} \times 0.433\text{ psi/ft} = 14.722\text{ psi} Pressure Loss = 34 ft × 0.433 psi/ft = 14.722 psi
Step 2: Subtract elevation loss from supply pressure. Static Pressure at Fixture = 72.0 psi − 14.722 psi = 57.278 psi \text{Static Pressure at Fixture} = 72.0\text{ psi} - 14.722\text{ psi} = 57.278\text{ psi} Static Pressure at Fixture = 72.0 psi − 14.722 psi = 57.278 psi
Result: The available static pressure at the third-floor fixture is 57.28 psi .
Worked Example 4: Converting Pressure to Vertical Head
Problem: A pressure gauge connected to the test tee at the base of a vertical soil stack reads 15.6 psi during a water test. How high is the water column above the gauge?
Step 1: Multiply pressure by the head constant (2.31 ft/psi). Head = 15.6 psi × 2.31 ft/psi = 36.036 feet \text{Head} = 15.6\text{ psi} \times 2.31\text{ ft/psi} = 36.036\text{ feet} Head = 15.6 psi × 2.31 ft/psi = 36.036 feet
Result: The height of the water column in the stack is 36.04 feet .
Pipe Volume, Gallon Capacity & Water Weight
Plumbers regularly calculate the volume and weight of water held in storage tanks, expansion vessels, and hydronic or domestic distribution systems to verify hanger loads and tank capacities.
Key Constants
1 cubic foot ( 1 ft 3 1\text{ ft}^3 1 ft 3 ): Contains 7.48 gallons of water.
1 gallon of fresh water: Weighs 8.34 pounds .
1 cubic foot of fresh water: Weighs 62.4 pounds ( 7.48 gal × 8.34 lbs/gal = 62.38 lbs 7.48\text{ gal} \times 8.34\text{ lbs/gal} = 62.38\text{ lbs} 7.48 gal × 8.34 lbs/gal = 62.38 lbs ).
Cylindrical Volume Formulas Volume (cu ft) = π × r 2 × L = 0.7854 × D 2 × L \text{Volume (cu ft)} = \pi \times r^2 \times L = 0.7854 \times D^2 \times L Volume (cu ft) = π × r 2 × L = 0.7854 × D 2 × L
(Where r r r and D D D are radius and diameter in feet, and L L L is length/height in feet).
Plumber's Quick Gallon Rule for Piping
For cylindrical pipes with diameter d d d in inches and length L L L in feet : Gallons ≈ 0.0408 × d 2 × L \text{Gallons} \approx 0.0408 \times d^2 \times L Gallons ≈ 0.0408 × d 2 × L
(Derivation: π × ( d / 12 ) 2 4 × 7.4805 = 0.7854 144 × 7.4805 × d 2 = 0.0408 × d 2 \frac{\pi \times (d/12)^2}{4} \times 7.4805 = \frac{0.7854}{144} \times 7.4805 \times d^2 = 0.0408 \times d^2 4 π × ( d /12 ) 2 × 7.4805 = 144 0.7854 × 7.4805 × d 2 = 0.0408 × d 2 ).
- Pipe Nominal Diameter ( d d d ) Gallons per Linear Foot Water Weight per Linear Foot
- 1 inch 0.041 gal/ft 0.34 lbs/ft
- 1-1/2 inch 0.092 gal/ft 0.77 lbs/ft
- 2 inch 0.163 gal/ft 1.36 lbs/ft
- 3 inch 0.367 gal/ft 3.06 lbs/ft
- 4 inch 0.653 gal/ft 5.45 lbs/ft
- 6 inch 1.469 gal/ft 12.25 lbs/ft
- Worked Example 5: Total Water Weight in a Storage Tank
Problem: A commercial storage water heater has a capacity of 120 gallons . If the empty tank weighs 310 pounds , what is the total combined floor load when the tank is filled with water?
Step 1: Calculate water weight. Water Weight = 120 gallons × 8.34 lbs/gallon = 1 , 000.8 pounds \text{Water Weight} = 120\text{ gallons} \times 8.34\text{ lbs/gallon} = 1,000.8\text{ pounds} Water Weight = 120 gallons × 8.34 lbs/gallon = 1 , 000.8 pounds
Step 2: Add empty tank weight. Total Load = 1 , 000.8 lbs + 310.0 lbs = 1 , 310.8 pounds \text{Total Load} = 1,000.8\text{ lbs} + 310.0\text{ lbs} = 1,310.8\text{ pounds} Total Load = 1 , 000.8 lbs + 310.0 lbs = 1 , 310.8 pounds
Result: The structural floor load is 1,310.8 pounds .
Worked Example 6: Pipe Volume Capacity
Problem: How many gallons of water are contained in a 4-inch diameter horizontal chilled water supply pipe with an overall length of 150 feet ?
Method A (Standard Geometry):
Pipe radius in feet: r = 2 inches / 12 in/ft = 0.1667 ft r = 2\text{ inches} / 12\text{ in/ft} = 0.1667\text{ ft} r = 2 inches /12 in/ft = 0.1667 ft
Cross-sectional area: A = π × ( 0.1667 ft ) 2 = 3.1416 × 0.02778 = 0.08727 sq ft A = \pi \times (0.1667\text{ ft})^2 = 3.1416 \times 0.02778 = 0.08727\text{ sq ft} A = π × ( 0.1667 ft ) 2 = 3.1416 × 0.02778 = 0.08727 sq ft
Volume in cubic feet: V = 0.08727 sq ft × 150 ft = 13.09 cu ft V = 0.08727\text{ sq ft} \times 150\text{ ft} = 13.09\text{ cu ft} V = 0.08727 sq ft × 150 ft = 13.09 cu ft
Convert to gallons: 13.09 cu ft × 7.48 gal/cu ft = 97.91 gallons 13.09\text{ cu ft} \times 7.48\text{ gal/cu ft} = 97.91\text{ gallons} 13.09 cu ft × 7.48 gal/cu ft = 97.91 gallons
Method B (Plumber's Quick Rule): Gallons = 0.0408 × ( 4 ) 2 × 150 = 0.0408 × 16 × 150 = 97.92 gallons \text{Gallons} = 0.0408 \times (4)^2 \times 150 = 0.0408 \times 16 \times 150 = 97.92\text{ gallons} Gallons = 0.0408 × ( 4 ) 2 × 150 = 0.0408 × 16 × 150 = 97.92 gallons
Result: The pipe holds approximately 97.9 gallons of water.
Fitting Allowances, Center-to-Center & Takeoffs
Cutting pipe to exact dimensions requires understanding the geometric relationship between fittings and pipe segments. +-------------------------------------------------------------------------+
- | FITTING TAKEOFF GEOMETRY |
- | |
- | |<------------------- Center-to-Center (C-to-C) -------------------->|
- | | | |
- | |<- Takeoff A ->| |<- Takeoff B ->| | |
- | [Fitting A]=====(Pipe Stop)=====================(Pipe Stop)=====[Fitting B]
- | |<------------- Cut Length ------------>| |
- +-------------------------------------------------------------------------+
- Definitions
Center-to-Center (C-to-C): The measurement taken from the center point of one fitting to the center point of the connecting fitting.
Face-to-Center (F-to-C): The distance from the center of the fitting to the external face of its hub or socket.
Socket Depth (Insertion Depth): The distance the pipe slides into the fitting socket before hitting the internal pipe stop shoulder.
Fitting Allowance (Takeoff): The distance from the center of the fitting to the internal pipe stop. This is the portion of the fitting that adds length to the assembly beyond the cut pipe end.
Cut Length Formula Cut Length = Center-to-Center Distance − ( Takeoff Fitting A + Takeoff Fitting B ) \text{Cut Length} = \text{Center-to-Center Distance} - (\text{Takeoff Fitting A} + \text{Takeoff Fitting B}) Cut Length = Center-to-Center Distance − ( Takeoff Fitting A + Takeoff Fitting B )
45-Degree Offset Mathematics
When routing piping around structural obstructions using 45-degree elbows: Travel = Offset × 1.414 ( or Offset 0.7071 ) \text{Travel} = \text{Offset} \times 1.414 \quad \left(\text{or } \frac{\text{Offset}}{0.7071}\right) Travel = Offset × 1.414 ( or 0.7071 Offset ) Advance (Run) = Offset ( for 45 ∘ bends, the horizontal advance equals the vertical offset ) \text{Advance (Run)} = \text{Offset} \quad (\text{for } 45^\circ \text{ bends, the horizontal advance equals the vertical offset}) Advance (Run) = Offset ( for 4 5 ∘ bends, the horizontal advance equals the vertical offset ) Cut Length of Travel Piece = Travel − ( Takeoff of 1st 45 ∘ Bend + Takeoff of 2nd 45 ∘ Bend ) \text{Cut Length of Travel Piece} = \text{Travel} - (\text{Takeoff of 1st } 45^\circ \text{ Bend} + \text{Takeoff of 2nd } 45^\circ \text{ Bend}) Cut Length of Travel Piece = Travel − ( Takeoff of 1st 4 5 ∘ Bend + Takeoff of 2nd 4 5 ∘ Bend )
Worked Example 7: Pipe Cut Length Calculation
Problem: A plumber is fabricating a 3-inch PVC horizontal drain line between two 90-degree elbows. The blueprint indicates a center-to-center distance of 60 inches . The manufacturer fitting specification lists the takeoff allowance for each 3-inch elbow as 1-13/16 inches ( 1.8125 in 1.8125\text{ in} 1.8125 in ). What is the required cut length of the pipe?
Step 1: Calculate total takeoff deduction. Total Takeoff = 1.8125 in + 1.8125 in = 3.625 inches ( 3 - 5 / 8 in ) \text{Total Takeoff} = 1.8125\text{ in} + 1.8125\text{ in} = 3.625\text{ inches} \quad (3\text{-}5/8\text{ in}) Total Takeoff = 1.8125 in + 1.8125 in = 3.625 inches ( 3 - 5/8 in )
Step 2: Deduct takeoff from center-to-center measurement. Cut Length = 60.0 in − 3.625 in = 56.375 inches ( 56 - 3 / 8 in ) \text{Cut Length} = 60.0\text{ in} - 3.625\text{ in} = 56.375\text{ inches} \quad (56\text{-}3/8\text{ in}) Cut Length = 60.0 in − 3.625 in = 56.375 inches ( 56 - 3/8 in )
Result: The pipe must be cut to 56-3/8 inches .
Master Trade Math Reference Table
Calculation Type Formula Standard Constants
Drainage Fall Fall (in) = Slope (in/ft) × Run (ft) \text{Fall (in)} = \text{Slope (in/ft)} \times \text{Run (ft)} Fall (in) = Slope (in/ft) × Run (ft) 1 / 4 " / ft = 0.0208 1/4"/\text{ft} = 0.0208 1/4"/ ft = 0.0208 ; 1 / 8 " / ft = 0.0104 1/8"/\text{ft} = 0.0104 1/8"/ ft = 0.0104
Drainage Slope Slope (in/ft) = Fall (in) Run (ft) \text{Slope (in/ft)} = \frac{\text{Fall (in)}}{\text{Run (ft)}} Slope (in/ft) = Run (ft) Fall (in) Minimum 1 / 4 " 1/4" 1/4" for ≤ 2.5 " \le 2.5" ≤ 2.5" ; 1 / 8 " 1/8" 1/8" for 3 " – 6 " 3"\text{--}6" 3" – 6"
Hydrostatic Pressure psi = Head (ft) × 0.433 \text{psi} = \text{Head (ft)} \times 0.433 psi = Head (ft) × 0.433 0.433 psi per vertical foot of head 0.433\text{ psi per vertical foot of head} 0.433 psi per vertical foot of head
Water Column Head Head (ft) = psi × 2.31 \text{Head (ft)} = \text{psi} \times 2.31 Head (ft) = psi × 2.31 2.31 feet of head per 1.0 psi 2.31\text{ feet of head per } 1.0\text{ psi} 2.31 feet of head per 1.0 psi
Water Weight Weight (lbs) = Gallons × 8.34 \text{Weight (lbs)} = \text{Gallons} \times 8.34 Weight (lbs) = Gallons × 8.34 8.34 lbs/gal 8.34\text{ lbs/gal} 8.34 lbs/gal ; 62.4 lbs/cu ft 62.4\text{ lbs/cu ft} 62.4 lbs/cu ft
Cylindrical Gallons Gal = 0.7854 × D 2 × L × 7.48 \text{Gal} = 0.7854 \times D^2 \times L \times 7.48 Gal = 0.7854 × D 2 × L × 7.48 7.48 gallons per cubic foot 7.48\text{ gallons per cubic foot} 7.48 gallons per cubic foot
Quick Pipe Gallons Gal ≈ 0.0408 × d 2 × L \text{Gal} \approx 0.0408 \times d^2 \times L Gal ≈ 0.0408 × d 2 × L d = diameter in inches d = \text{diameter in inches} d = diameter in inches ; L = length in feet L = \text{length in feet} L = length in feet
45 ∘ 45^\circ 4 5 ∘ Offset Travel Travel = Offset × 1.414 \text{Travel} = \text{Offset} \times 1.414 Travel = Offset × 1.414 2 ≈ 1.4142 \sqrt{2} \approx 1.4142 2 ≈ 1.4142
Pipe Cut Length Cut = C-to-C − ( Takeoff 1 + Takeoff 2 ) \text{Cut} = \text{C-to-C} - (\text{Takeoff}_1 + \text{Takeoff}_2) Cut = C-to-C − ( Takeoff 1 + Takeoff 2 ) Manufacturer fitting table allowances