Study guide
6.3 Inlet and Outlet Pipes, Net Filling Rate, Alternating Flow & Tank Leakage Problems
RRB Section Controller 2026: Free Written CBT Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview & Operational Profile
1.1 Written CBT Pattern, Scoring & Selection 1.2 Eligibility, Documents & A-2 Medical Requirements
2 Chapter 2: Number Systems & Arithmetic Foundations
2.1 Number Systems, Divisibility Rules, Prime Factorization & Remainder Theorem 2.2 Unit Digits, Cyclicity Rules & Power Modulo Calculations 2.3 HCF and LCM Properties, Prime Factorization & Practical Word Problems 2.4 Fractions, Decimals, Surds, Indices & BODMAS Simplification
3 Chapter 3: Commercial Arithmetic: Percentages, Profit & Rates
3.1 Percentages, Fractional Equivalents, Successive Variations & Population Formulas 3.2 Cost Price, Selling Price, Profit/Loss Percentage, Dishonest Dealer & Discount Schemes 3.3 Simple Interest, Compound Interest Formulas, Annual/Semi-Annual Compounding & Difference Traps
4 Chapter 4: Ratios, Proportions, Mixtures & Partnerships
4.1 Ratios, Duplicate/Sub-Duplicate Ratios, Direct and Inverse Variations & Proportional Sharing 4.2 Averages, Change in Average, Batsman/Bowling Averages & Replacement Problems 4.3 Rule of Alligation, Removal-Replacement Mixtures & Partnership Capital-Time Sharing
5 Chapter 5: Motion Dynamics, Time, Distance & Train Logistics
5.1 Time, Speed, Distance Relations, Average Speed & Unit Conversions 5.2 Train Problems: Passing Poles, Platforms, Moving Objects & Relative Speed in Opposite/Same Directions 5.3 Upstream, Downstream Boat Velocity, Still Water Speed & Circular Track Races
6 Chapter 6: Work Efficiency, Pipes & Operational Scheduling
6.1 Individual and Group Work, Efficiency Ratios, Work Equivalences & Mandays Formula 6.2 Alternate Day Working, Negative Work & Wage Distribution Based on Work Done 6.3 Inlet and Outlet Pipes, Net Filling Rate, Alternating Flow & Tank Leakage Problems
7 Chapter 7: Algebra, Linear Equations & Progressions
7.1 Algebraic Identities, Polynomial Factorization & Systems of Linear Equations in Two Variables 7.2 Quadratic Equations, Nature of Roots, Discriminant Analysis & Maximum/Minimum Values 7.3 Arithmetic Progressions (AP), General Term, Sum of n Terms & Sequence Modeling
8 Chapter 8: Mensuration: 2D Areas & 3D Solids
8.1 Lines, Angles, Triangle Theorems, Congruence/Similarity & Circle Tangent Properties 8.2 Perimeter and Area of Quadrilaterals, Polygons, Circles & Shaded Region Problems 8.3 Surface Area and Volume of Cubes, Cuboids, Cylinders, Cones, Spheres & Melting-Recasting Solids
9 Chapter 9: Statistics, Probability & Data Interpretation
9.1 Mean, Median, Mode, Range, Mean Deviation & Standard Deviation 9.2 Permutations, Combinations, Classical Probability, Independent Events & Odds 9.3 Tabular Data Interpretation, Bar Charts, Grouped Graphs & Percentage Calculation Shortcuts 9.4 Pie Charts (Angle vs Percentage), Line Trend Graphs & Quantitative Data Sufficiency
10 Chapter 10: Multi-Source & Graphical Analysis
10.1 Multi-Source Analysis, Set Data & Arrangement 10.2 Scatter Plots, Histograms & Distribution Curves
11 Chapter 11: Deductive Logic, Statements & Binary Puzzles
11.1 Syllogisms, Sets & Possibility Conclusions 11.2 Critical Reasoning: Implicit Assumptions, Strong vs Weak Arguments & Course of Action 11.3 Binary Logic: Truth-Tellers, Liars, Alternators & Matrix Logic Deductions
12 Chapter 12: Relational, Directional, Clock & Calendar Reasoning
12.1 Direct Family Relations, Coded Blood Relations & Family Tree Tree-Mapping Methods 12.2 Cardinal & Ordinal Directions, Multi-Step Turn Paths, Pythagorean Distance & Shadow Timing 12.3 Clock Hands Angular Speed, Angle Between Hands at Given Time, Coincidence & Faulty Clocks 12.4 Odd Days Concept, Reference Date Calculations, Leap Year Rules & Repeating Calendar Years
13 Chapter 13: English Reading Comprehension
13.1 English Comprehension: Main Idea, Support & Inference 13.2 English Comprehension: Application, Structure & Style
14 Chapter 14: Mental Reasoning: Analogies & Series
14.1 Semantic, Letter & Number Analogies 14.2 Number Series: Differences, Powers & Missing Terms 14.3 Interleaved, Recursive & Wrong-Term Series
15 Chapter 15: Mental Reasoning: Coding & Ranking
15.1 Letter Shifts, Reversal & Numerical Codes 15.2 Message Intersections & Conditional Coding Tables 15.3 Ranking, People Between & Position Interchanges
16 Chapter 16: Mental Reasoning: Seating Arrangements
16.1 Linear Seating & Parallel Rows 16.2 Circular Seating, Facing & Rotational Symmetry
6.3 Inlet and Outlet Pipes, Net Filling Rate, Alternating Flow & Tank Leakage Problems
Key Takeaways Explain This Topic AI
Pipes and cisterns operate identically to Time and Work, where inlet pipes represent positive work ( + 1 / x +1/x + 1/ x ) and outlet/drain pipes represent negative work ( − 1 / y -1/y − 1/ y ).
Net filling rate for an inlet filling in x x x hours and an outlet emptying in y y y hours ( y > x y > x y > x ) is y − x x y \frac{y - x}{xy} x y y − x , yielding a net filling time of x y y − x \frac{xy}{y - x} y − x x y .
If a tank fills in T T T hours normally but requires T ′ T' T ′ hours due to a bottom fissure, the leak alone empties the full tank in T × T ′ T ′ − T \frac{T \times T'}{T' - T} T ′ − T T × T ′ hours.
In multi-pipe staged operations where a pipe is shut off prematurely before tank filling, apply backward virtual volume addition or solve ( T − t c ) E 1 + T E 2 = Capacity (T - t_c)E_1 + T E_2 = \text{Capacity} ( T − t c ) E 1 + T E 2 = Capacity .
Absolute tank capacity (in liters) is established by equating fractional emptying/filling rates with calibrated physical discharge rates ( Q Q Q liters/min) via Capacity = Q × T drain \text{Capacity} = Q \times T_{\text{drain}} Capacity = Q × T drain .
Last updated: October 2026
Idealized constant-flow assumptions
These exercises assume constant flow rates independent of water level, additive flows, and no overflow or evaporation. Fill-time formulas start with an empty tank; emptying formulas start with a full one. Equal inlet and drain rates leave the level unchanged. In the alternating-flow diagram, E B E_B E B denotes a positive removal magnitude; signed drain rates in the worked equations are negative. If the inlet fills the tank in its first turn, stop there. Otherwise the peak-threshold formula requires positive net cycle progress.
The Hydraulic Analogy to Time & Work
The mathematical framework governing pipes and cisterns mirrors mechanical work, with one critical distinction: pipes possess directional flow. Total Tank Capacity (Volume) ≡ Total Work ( W ) \text{Total Tank Capacity (Volume)} \equiv \text{Total Work } (W) Total Tank Capacity (Volume) ≡ Total Work ( W ) Volumetric Flow Rate ( R ) ≡ Efficiency ( E ) \text{Volumetric Flow Rate } (R) \equiv \text{Efficiency } (E) Volumetric Flow Rate ( R ) ≡ Efficiency ( E ) Filling or Emptying Duration ( T ) ≡ Time Taken ( T ) \text{Filling or Emptying Duration } (T) \equiv \text{Time Taken } (T) Filling or Emptying Duration ( T ) ≡ Time Taken ( T ) Capacity = Flow Rate × Time ⟺ W = E × T \text{Capacity} = \text{Flow Rate} \times \text{Time} \iff W = E \times T Capacity = Flow Rate × Time ⟺ W = E × T
Directional Flow Classifications
Inlet Pipe (Filling Pipe): Introduces fluid into the cistern. Represents positive work ( + R +R + R ). If an inlet fills a cistern in x x x hours, its rate is + 1 x +\frac{1}{x} + x 1 of tank capacity per hour.
Outlet Pipe (Waste Pipe / Drain): Evacuates fluid from the cistern. Represents negative work ( − R -R − R ). If an outlet empties a full cistern in y y y hours, its rate is − 1 y -\frac{1}{y} − y 1 of tank capacity per hour. +-----------------------------------------------------------------------------+
- | INLET AND OUTLET RATE SUPERPOSITION |
- +-----------------------------------------------------------------------------+
- | Inlet Pipe A (Fills in x hours): Rate = +1/x of tank volume per hour |
- | Outlet Pipe B (Empties in y hours): Rate = -1/y of tank volume per hour |
- | │ |
- | ▼ |
- | Both Pipes Open Simultaneously: |
- | Net Flow Rate = (+1/x) + (-1/y) = (y - x) / (xy) |
- | │ |
- | ┌────────────────────┴────────────────────┐ |
- | ▼ (If y > x: Inlet is Faster) ▼ (If x > y: Drain Faster)│
- | Net Rate > 0 -> TANK FILLS Net Rate < 0 -> TANK EMPTIES|
- | Time to Fill = (x * y) / (y - x) Time to Empty = (x * y)/(x - y)|
- +-----------------------------------------------------------------------------+
Pipe Configuration Individual Fill/Empty Times Net Hourly Flow Rate Net Operational Result Formula for Net Time
Two Inlets ( A , B A, B A , B ) A = x , B = y A = x, B = y A = x , B = y + 1 x + 1 y = x + y x y +\frac{1}{x} + \frac{1}{y} = \frac{x+y}{xy} + x 1 + y 1 = x y x + y Tank Fills T = x y x + y T = \frac{xy}{x+y} T = x + y x y
Inlet A A A & Drain B B B ( y > x y > x y > x ) A = x (fill) , B = y (empty) A = x \text{ (fill)}, B = y \text{ (empty)} A = x (fill) , B = y (empty) + 1 x − 1 y = y − x x y +\frac{1}{x} - \frac{1}{y} = \frac{y-x}{xy} + x 1 − y 1 = x y y − x Tank Fills T = x y y − x T = \frac{xy}{y-x} T = y − x x y
Inlet A A A & Drain B B B ( x > y x > y x > y ) A = x (fill) , B = y (empty) A = x \text{ (fill)}, B = y \text{ (empty)} A = x (fill) , B = y (empty) − 1 y + 1 x = − x − y x y -\frac{1}{y} + \frac{1}{x} = -\frac{x-y}{xy} − y 1 + x 1 = − x y x − y Full Tank Empties T = x y x − y T = \frac{xy}{x-y} T = x − y x y
Three Inlets ( A , B , C A, B, C A , B , C ) x , y , z x, y, z x , y , z + 1 x + 1 y + 1 z +\frac{1}{x} + \frac{1}{y} + \frac{1}{z} + x 1 + y 1 + z 1 Tank Fills T = x y z x y + y z + z x T = \frac{xyz}{xy + yz + zx} T = x y + yz + z x x yz
Two Inlets & One Drain A = x , B = y , C = z (empty) A=x, B=y, C=z \text{ (empty)} A = x , B = y , C = z (empty) + 1 x + 1 y − 1 z +\frac{1}{x} + \frac{1}{y} - \frac{1}{z} + x 1 + y 1 − z 1 Fills if 1 x + 1 y > 1 z \frac{1}{x}+\frac{1}{y} > \frac{1}{z} x 1 + y 1 > z 1 T = x y z y z + x z − x y T = \frac{xyz}{yz + xz - xy} T = yz + x z − x y x yz
The Tank Leakage Problem
A universal staple of railway quantitative exams involves a cistern that fills in normal duration T T T , but takes an extended duration T ′ T' T ′ ( T ′ > T T' > T T ′ > T ) due to a leak or structural fissure at the bottom.
Mathematical Derivation
Let the normal inlet pump rate be R in = 1 T R_{\text{in}} = \frac{1}{T} R in = T 1 , and the leak's emptying rate be R leak = 1 L R_{\text{leak}} = \frac{1}{L} R leak = L 1 .
When both operate simultaneously, the net filling rate is: R net = R in − R leak = 1 T ′ R_{\text{net}} = R_{\text{in}} - R_{\text{leak}} = \frac{1}{T'} R net = R in − R leak = T ′ 1 1 T − 1 L = 1 T ′ ⟹ 1 L = 1 T − 1 T ′ = T ′ − T T ⋅ T ′ \frac{1}{T} - \frac{1}{L} = \frac{1}{T'} \implies \frac{1}{L} = \frac{1}{T} - \frac{1}{T'} = \frac{T' - T}{T \cdot T'} T 1 − L 1 = T ′ 1 ⟹ L 1 = T 1 − T ′ 1 = T ⋅ T ′ T ′ − T
Inverting to find the time L L L taken by the leak alone to empty a completely full tank: T leak = T ⋅ T ′ T ′ − T T_{\text{leak}} = \frac{T \cdot T'}{T' - T} T leak = T ′ − T T ⋅ T ′
Tip
Rapid Mental Calculation: If an overhead tank fills in 8 hours normally, but takes 10 hours with a leak, the leak empties the full tank in 8 × 10 10 − 8 = 80 2 = 40 \frac{8 \times 10}{10 - 8} = \frac{80}{2} = 40 10 − 8 8 × 10 = 2 80 = 40 hours. No scratchpad fractions needed!
Staged Multi-Pipe Valve Operations & Premature Closures
In yard watering plants, multiple pumps operate concurrently, but one or more valves may be shut down before the tank is completely full to prevent overflow or conserve power.
The Problem Structure
Pipes A A A and B B B can fill a tank in x x x and y y y minutes respectively. Both pipes are opened simultaneously, but Pipe A A A is closed t t t minutes before the tank is full. What is the total time T T T required to fill the tank?
Method 1: Direct Work Equation: Pipe A A A operates for ( T − t ) (T - t) ( T − t ) minutes; Pipe B B B operates for the entire T T T minutes. ( T − t ) ⋅ E A + T ⋅ E B = Total Capacity W (T - t) \cdot E_A + T \cdot E_B = \text{Total Capacity } W ( T − t ) ⋅ E A + T ⋅ E B = Total Capacity W T ( E A + E B ) − t ⋅ E A = W ⟹ T = W + t ⋅ E A E A + E B T(E_A + E_B) - t \cdot E_A = W \implies T = \frac{W + t \cdot E_A}{E_A + E_B} T ( E A + E B ) − t ⋅ E A = W ⟹ T = E A + E B W + t ⋅ E A
Method 2: Virtual Volume Shortcut: If Pipe A A A had remained open for those final t t t minutes, it would have added an extra virtual volume of t × E A t \times E_A t × E A units. Add this virtual volume to the total tank capacity and divide by their combined rate: T = Capacity + ( t × E A ) E A + E B T = \frac{\text{Capacity} + (t \times E_A)}{E_A + E_B} T = E A + E B Capacity + ( t × E A )
Alternating Pipe Flow & The Peak Threshold Protection
When inlet and drain pipes operate alternately (e.g., Inlet A A A open in Minute 1, Drain B B B open in Minute 2), the system behaves identically to the negative work dynamics covered in Section 6.2. +-----------------------------------------------------------------------------+
- | ALTERNATING FLOW: THE PEAK THRESHOLD |
- +-----------------------------------------------------------------------------+
- | Inlet A fills in x min (Rate = +E_A) | Drain B empties in y min (Rate = -E_B) |
- | Net cycle yield = E_A - E_B units every 2 minutes |
- | │ |
- | ▼ |
- | CRITICAL RULE: Cistern is FULL the moment water reaches Capacity (C) on |
- | the inlet's turn! Drain B never operates after the tank is filled. |
- | │ |
- | ▼ |
- | 1. Reserve Inlet's single stride: Threshold = C - E_A |
- | 2. Full 2-min cycles to threshold: k = ceil[(C - E_A) / (E_A - E_B)] |
- | 3. Final fractional minute on inlet turn: dt = (C - Work_k) / E_A |
- +-----------------------------------------------------------------------------+
Warning
Never divide full tank capacity C C C directly by ( E A − E B ) (E_A - E_B) ( E A − E B ) in alternating flow problems. The tank reaches full capacity during an odd-numbered minute (when the inlet is operating) before the drain can act to reduce the level.
Absolute Tank Capacity Determination from Volumetric Telemetry
A high-yield question type on RRB exams asks for the absolute volumetric capacity of the tank in liters . These problems bridge fractional unit rates with physical flow rates given in liters per minute (LPM) or cubic meters per hour ( m 3 / h m^3/h m 3 / h ).
The Systematic Three-Step Solution Framework
Step 1: Isolate the Fractional Rate of the Calibrated Pipe: Use the LCM or reciprocal method to calculate the theoretical fractional rate ( R k = 1 / T k R_k = 1/T_k R k = 1/ T k ) of the specific pipe whose absolute physical discharge rate is provided.
Step 2: Determine Theoretical Time to Evacuate/Fill Alone: Compute the total time T k T_k T k (in minutes or hours) that this specific pipe would take to fill or empty the entire tank alone.
Step 3: Multiply Calibrated Discharge Rate by Total Time: Absolute Tank Capacity (Liters) = Discharge Rate (Liters/minute) × T k (minutes) \text{Absolute Tank Capacity (Liters)} = \text{Discharge Rate (Liters/minute)} \times T_k \text{ (minutes)} Absolute Tank Capacity (Liters) = Discharge Rate (Liters/minute) × T k (minutes)
Example: An emptying pipe discharges 40 L/min 40\text{ L/min} 40 L/min . If calculations prove this emptying pipe alone would evacuate the full tank in 25 minutes 25\text{ minutes} 25 minutes , the absolute tank capacity is: Capacity = 40 liters minute × 25 minutes = 1 , 000 liters \text{Capacity} = 40 \frac{\text{liters}}{\text{minute}} \times 25 \text{ minutes} = 1,000 \text{ liters} Capacity = 40 minute liters × 25 minutes = 1 , 000 liters
- Worked Examples
- Worked Example 1: Multi-Pump Locomotive Fueling Siding with Staged Closures
Problem: A diesel locomotive fueling siding has three supply lines connected to an underground fuel storage reservoir. Line A can fill the reservoir in 20 hours, Line B in 30 hours, and Line C in 60 hours. All three supply lines are opened simultaneously. However, due to fuel manifold maintenance, Line C is shut off 4 hours before the reservoir is completely filled, and Line B is shut off 2 hours before the reservoir is filled. Line A operates continuously until the reservoir is completely full. What is the total time taken to fill the fuel reservoir?
Step 1: Determine Total Capacity Units and Pipe Efficiencies: Total Reservoir Capacity W = LCM ( 20 , 30 , 60 ) = 60 units \text{Total Reservoir Capacity } W = \text{LCM}(20, 30, 60) = 60 \text{ units} Total Reservoir Capacity W = LCM ( 20 , 30 , 60 ) = 60 units E A = 60 20 = 3 units/hour , E B = 60 30 = 2 units/hour , E C = 60 60 = 1 unit/hour E_A = \frac{60}{20} = 3 \text{ units/hour}, \quad E_B = \frac{60}{30} = 2 \text{ units/hour}, \quad E_C = \frac{60}{60} = 1 \text{ unit/hour} E A = 20 60 = 3 units/hour , E B = 30 60 = 2 units/hour , E C = 60 60 = 1 unit/hour
Step 2: Formulate the Total Time Equation: Let T T T be the total operating duration in hours.
Line A operates for the full duration: t A = T t_A = T t A = T hours.
Line B operates for t B = ( T − 2 ) t_B = (T - 2) t B = ( T − 2 ) hours.
Line C operates for t C = ( T − 4 ) t_C = (T - 4) t C = ( T − 4 ) hours. 3 ( T ) + 2 ( T − 2 ) + 1 ( T − 4 ) = 60 3(T) + 2(T - 2) + 1(T - 4) = 60 3 ( T ) + 2 ( T − 2 ) + 1 ( T − 4 ) = 60
Step 3: Solve Algebraically for T T T : 3 T + 2 T − 4 + T − 4 = 60 3T + 2T - 4 + T - 4 = 60 3 T + 2 T − 4 + T − 4 = 60 6 T − 8 = 60 ⟹ 6 T = 68 ⟹ T = 68 6 = 34 3 = 11 1 3 hours 6T - 8 = 60 \implies 6T = 68 \implies T = \frac{68}{6} = \frac{34}{3} = 11\frac{1}{3} \text{ hours} 6 T − 8 = 60 ⟹ 6 T = 68 ⟹ T = 6 68 = 3 34 = 11 3 1 hours
Step 4: Verify via Virtual Volume Shortcut: Virtual Volume Added = ( 2 hrs × E B ) + ( 4 hrs × E C ) = ( 2 × 2 ) + ( 4 × 1 ) = 4 + 4 = 8 units \text{Virtual Volume Added} = (2 \text{ hrs} \times E_B) + (4 \text{ hrs} \times E_C) = (2 \times 2) + (4 \times 1) = 4 + 4 = 8 \text{ units} Virtual Volume Added = ( 2 hrs × E B ) + ( 4 hrs × E C ) = ( 2 × 2 ) + ( 4 × 1 ) = 4 + 4 = 8 units Total Virtual Capacity = 60 + 8 = 68 units \text{Total Virtual Capacity} = 60 + 8 = 68 \text{ units} Total Virtual Capacity = 60 + 8 = 68 units Combined Hourly Rate = E A + E B + E C = 3 + 2 + 1 = 6 units/hour \text{Combined Hourly Rate} = E_A + E_B + E_C = 3 + 2 + 1 = 6 \text{ units/hour} Combined Hourly Rate = E A + E B + E C = 3 + 2 + 1 = 6 units/hour T = 68 6 = 11 1 3 hours (11 hours 20 minutes) T = \frac{68}{6} = 11\frac{1}{3} \text{ hours (11 hours 20 minutes)} T = 6 68 = 11 3 1 hours (11 hours 20 minutes)
Worked Example 2: Overhead Water Tank Leakage & Capacity Derivation
Problem: An overhead coaching service reservoir fills in 6 hours via an electric pump under normal conditions. However, due to an undetected foundation leak at the bottom, it takes 8 hours to fill completely. (a) In how many hours will the leak alone evacuate the entire full reservoir? (b) If an auxiliary washout drainage tap discharging water at 45 liters per minute is opened simultaneously with the normal inlet pump and the active leak, the full reservoir empties in 24 hours. What is the total volumetric capacity of the reservoir in liters?
Step 1: Calculate Emptying Time of Leak Alone: Using the leakage shortcut: T leak = T ⋅ T ′ T ′ − T = 6 × 8 8 − 6 = 48 2 = 24 hours T_{\text{leak}} = \frac{T \cdot T'}{T' - T} = \frac{6 \times 8}{8 - 6} = \frac{48}{2} = 24 \text{ hours} T leak = T ′ − T T ⋅ T ′ = 8 − 6 6 × 8 = 2 48 = 24 hours
The leak alone empties the reservoir in 24 hours (emptying-rate magnitude R leak = 1 24 R_{\text{leak}} = \frac{1}{24} R leak = 24 1 reservoir/hr).
Step 2: Determine the Net Emptying Rate with Auxiliary Tap Open: Let R tap = 1 H R_{\text{tap}} = \frac{1}{H} R tap = H 1 be the emptying rate of the auxiliary drainage tap.
Under all three components, the full reservoir empties in 24 hours (net rate = − 1 24 = -\frac{1}{24} = − 24 1 ): R in − R leak − R tap = − 1 24 R_{\text{in}} - R_{\text{leak}} - R_{\text{tap}} = -\frac{1}{24} R in − R leak − R tap = − 24 1 1 6 − 1 24 − 1 H = − 1 24 \frac{1}{6} - \frac{1}{24} - \frac{1}{H} = -\frac{1}{24} 6 1 − 24 1 − H 1 = − 24 1 1 6 − 1 H = 0 ⟹ 1 H = 1 6 \frac{1}{6} - \frac{1}{H} = 0 \implies \frac{1}{H} = \frac{1}{6} 6 1 − H 1 = 0 ⟹ H 1 = 6 1
Therefore, the auxiliary washout tap alone would completely empty the full reservoir in 6 hours .
Step 3: Convert Time to Minutes and Calculate Absolute Capacity: T tap = 6 hours = 6 × 60 = 360 minutes T_{\text{tap}} = 6 \text{ hours} = 6 \times 60 = 360 \text{ minutes} T tap = 6 hours = 6 × 60 = 360 minutes Total Capacity = Discharge Rate × T tap = 45 liters minute × 360 minutes = 16 , 200 liters \text{Total Capacity} = \text{Discharge Rate} \times T_{\text{tap}} = 45 \frac{\text{liters}}{\text{minute}} \times 360 \text{ minutes} = 16,200 \text{ liters} Total Capacity = Discharge Rate × T tap = 45 minute liters × 360 minutes = 16 , 200 liters
Worked Example 3: Alternating Filling and Drainage Flow with Peak Threshold
Problem: A washing plant reservoir has an inlet pipe A that can fill it in 12 minutes, and a drain pipe B that can empty it in 18 minutes. If pipes A and B are opened alternately for 1 minute each, starting with Inlet Pipe A, in exactly how many minutes will the empty reservoir be completely filled for the first time?
Step 1: Compute Total Work Units and Minute Rates: Total Capacity C = LCM ( 12 , 18 ) = 36 units \text{Total Capacity } C = \text{LCM}(12, 18) = 36 \text{ units} Total Capacity C = LCM ( 12 , 18 ) = 36 units E A = + 36 12 = + 3 units/min , E B = − 36 18 = − 2 units/min E_A = +\frac{36}{12} = +3 \text{ units/min}, \quad E_B = -\frac{36}{18} = -2 \text{ units/min} E A = + 12 36 = + 3 units/min , E B = − 18 36 = − 2 units/min
Step 2: Determine Net Progress per 2-Minute Cycle: Work in Minute 1 (Pipe A) = + 3 units \text{Work in Minute 1 (Pipe A)} = +3 \text{ units} Work in Minute 1 (Pipe A) = + 3 units Work in Minute 2 (Pipe B) = − 2 units \text{Work in Minute 2 (Pipe B)} = -2 \text{ units} Work in Minute 2 (Pipe B) = − 2 units Net Yield per 2-minute cycle = + 3 − 2 = + 1 unit every 2 minutes \text{Net Yield per 2-minute cycle} = +3 - 2 = +1 \text{ unit every 2 minutes} Net Yield per 2-minute cycle = + 3 − 2 = + 1 unit every 2 minutes
Step 3: Establish the Peak Threshold Barrier: Deduct Pipe A's full single-minute stride from total capacity: Threshold Target = C − E A = 36 − 3 = 33 units \text{Threshold Target} = C - E_A = 36 - 3 = 33 \text{ units} Threshold Target = C − E A = 36 − 3 = 33 units
Step 4: Compute Cycles to Reach Threshold: k = 33 units 1 unit/cycle = 33 complete cycles k = \frac{33 \text{ units}}{1 \text{ unit/cycle}} = 33 \text{ complete cycles} k = 1 unit/cycle 33 units = 33 complete cycles
Time elapsed for 33 cycles = 33 × 2 = 66 minutes = 33 \times 2 = 66 \text{ minutes} = 33 × 2 = 66 minutes .
Water level accumulated = 33 × 1 = 33 units = 33 \times 1 = 33 \text{ units} = 33 × 1 = 33 units .
Step 5: Final Advance in Minute 67: At minute 67, Pipe A opens: Water Added = + 3 units \text{Water Added} = +3 \text{ units} Water Added = + 3 units Cumulative Volume = 33 + 3 = 36 units (100% FULL!) \text{Cumulative Volume} = 33 + 3 = 36 \text{ units (100\% FULL!)} Cumulative Volume = 33 + 3 = 36 units (100% FULL!)
The reservoir reaches 100% capacity at the end of the 67th minute. Pipe B never operates.
Conclusion: The reservoir is completely filled in 67 minutes (1 hour 7 minutes).
(Note: Naive division of 36 / 1 × 2 = 72 minutes 36 / 1 \times 2 = 72 \text{ minutes} 36/1 × 2 = 72 minutes overshoots the true answer by 5 full minutes!)
Calculation Traps & Tactical Shortcuts
Sign Confusion in Net Flow Equations: When an outlet pipe is active, its rate must enter the equation with a minus sign ( − 1 / y -1/y − 1/ y ). Adding drain rates instead of subtracting them is a common blunder under time pressure.
The Full Tank Emptying Distinction: Ensure you read whether the problem asks for the time to fill an empty tank or to empty a full tank . When drain rate exceeds inlet rate ( x > y x > y x > y ), the tank will empty, and net time is x y x − y \frac{xy}{x - y} x − y x y .
Unit Consistency in Discharge Conversions: If discharge is given in liters per minute and filling times are given in hours , immediately convert the filling time into minutes ( T × 60 T \times 60 T × 60 ) before multiplying by discharge rate.