Study guide
6.2 Distribution Uniformity (DUlq) & Catch-Can Audits
Irrigation Association Certified Irrigation Technician CIT
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview & Field Technician Fundamentals
1.1 The CIT Credential & Exam Structure 1.2 Jobsite Safety, Utility Locates & Safety Standards 1.3 Blueprint Reading & As-Built Documentation 1.4 Equipment & Tool Usage, Manufacturer Instructions & Maintenance
2 Chapter 2: Irrigation System Components & Piping
2.1 Pipe Materials, Pressure Ratings & SDR Standards 2.2 Fitting Installation, Solvent Welding & Joint Assembly 2.3 Control Valves, Master Valves & Isolation Valves 2.4 Pressure Regulators & Backflow Prevention Assemblies 2.5 Identifying Water Supplies & Source Capacity 2.6 Water Meter Usage, Flow Testing & Leak Identification
3 Chapter 3: Sprinkler Heads & Matched Precipitation Rates
3.1 Fixed Spray Heads, Rotors & Multi-Stream Nozzles 3.2 Head-to-Head Coverage & Nozzle Spacing 3.3 Matched Precipitation Rate (MPR) Principles
4 Chapter 4: Drip & Micro-Irrigation Systems
4.1 Drip Line Components & Pressure-Compensating Emitters 4.2 Drip Filtration, Flush Valves & Air Vents 4.3 Micro-Sprays & Subsurface Drip Irrigation (SDI)
5 Chapter 5: Basic Hydraulics & Pressure Calculations
5.1 Static vs Dynamic Pressure & Elevation Head 5.2 Flow Velocity, Friction Loss & Hazen-Williams 5.3 Available Pressure Budgets & Total Dynamic Head 5.4 Pumps: Types, Components, Controls & Safety
6 Chapter 6: Hydraulic Mathematics & System Auditing
6.1 Sprinkler Precipitation Rate Formulas 6.2 Distribution Uniformity (DUlq) & Catch-Can Audits 6.3 Cycle-and-Soak & Soil Water Management
7 Chapter 7: Electrical Principles & 24 VAC Solenoid Circuits
7.1 Ohm's Law & Electrical Fundamentals 7.2 24 VAC Solenoid Construction & Coil Operation 7.3 Field Wiring, Wire Sizing & Direct-Burial Splices 7.4 Transformer Operation, Amperage Testing & Controller Service
8 Chapter 8: Controller Operations & Field Troubleshooting
8.1 Irrigation Controllers & Smart ET Controls 8.2 Electrical Troubleshooting & Multimeter Diagnostics 8.3 Hydraulic & Mechanical Troubleshooting 8.4 Spring Startup & Seasonal Commissioning
6.2 Distribution Uniformity (DUlq) & Catch-Can Audits
Key Takeaways Explain This Topic AI
Lower-Quarter Distribution Uniformity (DUlq) measures how evenly water is applied across an irrigation zone, focusing on the average depth received by the lowest 25% of catch cans relative to the total area average.
The official formula for Lower-Quarter Distribution Uniformity is DUlq = (Average Catch Depth of Lowest 25% Cans / Overall Average Catch Depth of All Cans) × 100%.
Standard auditing protocols require a uniform grid of identical catch devices spaced 2 to 3 feet from heads and no more than 10 to 15 feet apart, running tests for 10 to 15 minutes for sprays or 30 to 60 minutes for rotors.
Catch-can volume in milliliters is converted to depth in inches using throat opening area: Depth (in) = (Volume in mL × 0.06102) / Throat Area in sq in.
The Scheduling Multiplier (SM) adjusts runtime to compensate for non-uniformity and ensure the lowest quarter receives adequate water, calculated as SM = 1 / (0.4 + 0.6 × DUlq).
Last updated: August 2026
6.2 Distribution Uniformity ( D U l q DU_{lq} D U lq ) & Catch-Can Audits
Quick Answer: Lower-Quarter Distribution Uniformity ( DU l q \text{DU}_{lq} DU lq ) measures application uniformity across an irrigation zone using catch cans. The formula is DU l q = ( Average depth of lowest 25% catch cans Overall average depth of all catch cans ) × 100 \text{DU}_{lq} = \left(\frac{\text{Average depth of lowest 25\% catch cans}}{\text{Overall average depth of all catch cans}}\right) \times 100 DU lq = ( Overall average depth of all catch cans Average depth of lowest 25% catch cans ) × 100 . Excellent systems achieve DU l q > 0.75 \text{DU}_{lq} > 0.75 DU lq > 0.75 (75%), while systems below 55% require head or nozzle maintenance. To compensate for non-uniformity without under-watering the dry spots, managers multiply base run time by the Scheduling Multiplier: SM = 1 0.4 + 0.6 × DU l q \text{SM} = \frac{1}{0.4 + 0.6 \times \text{DU}_{lq}} SM = 0.4 + 0.6 × DU lq 1 .
Concept of Lower-Quarter Distribution Uniformity ( DU l q \text{DU}_{lq} DU lq )
Even perfectly designed irrigation systems do not deposit water completely evenly across a lawn. Factors such as wind drift, head tilt, mismatched nozzles, pressure fluctuations, and improper spacing create wetter and drier patches. If an irrigation manager programmes run times based purely on average precipitation rate, half of the landscape will receive less than the targeted water volume—and the driest 25% of the zone will suffer severe drought stress, browning, or turf death.
To quantify irrigation uniformity, the Irrigation Association standardizes Lower-Quarter Distribution Uniformity ( DU l q \text{DU}_{lq} DU lq ) . DU l q \text{DU}_{lq} DU lq focuses specifically on the driest quarter of the audited zone: DU l q = D ˉ l q D ˉ a l l × 100 \text{DU}_{lq} = \frac{\bar{D}_{lq}}{\bar{D}_{all}} \times 100 DU lq = D ˉ a ll D ˉ lq × 100
Where:
D ˉ l q \bar{D}_{lq} D ˉ lq = Mean catch depth (or volume) of the lowest 25% of catch devices in the test grid
- D ˉ a l l \bar{D}_{all} D ˉ a ll = Mean catch depth (or volume) of all catch devices in the test grid
- Catch-Can Audit Field Protocol
Performing a standardized catch-can audit requires strict adherence to field protocols established by the Irrigation Association Smart Water Application Technologies (SWAT) and Certified Landscape Irrigation Auditor (CLIA) standards.
1. Equipment & Catch Can Specifications
Use identical catch containers across the entire grid. Standard IA audit catch devices feature a sharp-edged plastic throat opening (typically 16.0 in 2 16.0 \text{ in}^2 16.0 in 2 or 103.2 cm 2 103.2 \text{ cm}^2 103.2 cm 2 ) to eliminate splash-out.
Graduated cylinders calibrated in milliliters (mL) or liquid depth indicators marked directly in inches or millimeters.
2. Grid Layout Procedure
Position catch cans in a uniform geometric grid across the target zone.
Place cans 2 to 3 feet away from sprinkler heads to capture perimeter throw while avoiding head blind spots.
Space remaining cans evenly between heads, ensuring grid spacing does not exceed 10 to 15 feet apart.
For statistical validity, a minimum of 24 catch cans per irrigated zone is recommended.
3. Audit Test Duration
Spray Head Zones: Run system for 10 to 15 minutes (spray heads apply high volumes quickly).
Rotor Head Zones: Run system for 30 to 60 minutes (rotors apply water more slowly as arcs rotate).
Measure dynamic operating pressure at the first, middle, and last heads during the run using a Pitot tube or pressure gauge cap.
Audit must be halted if wind speeds exceed 5 mph ( 8 km/h 8 \text{ km/h} 8 km/h ), as wind significantly skews catch distribution.
Volume-to-Depth Calculations
If catch cans measure liquid volume in milliliters (mL), technicians must convert volume into linear depth in inches using the container throat area: 1 mL = 0.0610237 cubic inches (in 3 ) 1 \text{ mL} = 0.0610237 \text{ cubic inches (in}^3\text{)} 1 mL = 0.0610237 cubic inches (in 3 ) Depth (in) = Volume (mL) × 0.0610237 Catch Can Throat Area (in 2 ) \text{Depth (in)} = \frac{\text{Volume (mL)} \times 0.0610237}{\text{Catch Can Throat Area (in}^2\text{)}} Depth (in) = Catch Can Throat Area (in 2 ) Volume (mL) × 0.0610237
For a standard catch can with a 16.0 in 2 16.0 \text{ in}^2 16.0 in 2 throat area : Depth (in) = Volume (mL) × 0.0610237 16.0 = Volume (mL) × 0.003814 \text{Depth (in)} = \frac{\text{Volume (mL)} \times 0.0610237}{16.0} = \text{Volume (mL)} \times 0.003814 Depth (in) = 16.0 Volume (mL) × 0.0610237 = Volume (mL) × 0.003814
For example, a caught volume of 40 mL 40 \text{ mL} 40 mL in a 16.0 in 2 16.0 \text{ in}^2 16.0 in 2 catch can equals: Depth = 40 × 0.003814 = 0.1526 inches \text{Depth} = 40 \times 0.003814 = 0.1526 \text{ inches} Depth = 40 × 0.003814 = 0.1526 inches
Interpreting DU l q \text{DU}_{lq} DU lq Performance Ratings
The Irrigation Association establishes clear benchmark performance ratings for overhead sprinkler systems:
DU l q \text{DU}_{lq} DU lq Range System Performance Rating Required Field Actions
> 75% Excellent System operating optimally. Maintain routine nozzle cleaning and head leveling.
65% - 75% Good Standard commercial performance. Minor adjustments may improve efficiency.
55% - 65% Fair Noticeable non-uniformity. Check system operating pressure, unclog nozzles, correct head tilt.
< 55% Poor / Unacceptable Severe non-uniformity causing dry spots. Requires full head redesign, spacing adjustment, or MPR conversion.
The Scheduling Multiplier (SM)
To ensure the lowest quarter of the turf area receives the target net depth of water without under-watering, the base run time must be increased using the Scheduling Multiplier (SM) : SM = 1 0.4 + 0.6 × DU l q \text{SM} = \frac{1}{0.4 + 0.6 \times \text{DU}_{lq}} SM = 0.4 + 0.6 × DU lq 1
Where DU l q \text{DU}_{lq} DU lq is expressed as a decimal (e.g., 70 % = 0.70 70\% = 0.70 70% = 0.70 ).
Operational Impact of SM:
If DU l q = 0.80 \text{DU}_{lq} = 0.80 DU lq = 0.80 (80% excellent uniformity): SM = 1 0.4 + 0.6 ( 0.80 ) = 1 0.88 = 1.136 \text{SM} = \frac{1}{0.4 + 0.6(0.80)} = \frac{1}{0.88} = 1.136 SM = 0.4 + 0.6 ( 0.80 ) 1 = 0.88 1 = 1.136
Run time is increased by only 13.6%.
If DU l q = 0.50 \text{DU}_{lq} = 0.50 DU lq = 0.50 (50% poor uniformity): SM = 1 0.4 + 0.6 ( 0.50 ) = 1 0.70 = 1.428 \text{SM} = \frac{1}{0.4 + 0.6(0.50)} = \frac{1}{0.70} = 1.428 SM = 0.4 + 0.6 ( 0.50 ) 1 = 0.70 1 = 1.428
Run time must be increased by 42.8% to adequately water the driest quarter, resulting in substantial over-watering in wetter areas.
Loading diagram... Catch-Can Grid Layout for a 4-Head Rotor Zone Audit
Worked Catch-Can Audit Dataset & DU l q \text{DU}_{lq} DU lq Calculation
The table below presents complete field audit data collected from 24 catch cans during a 15-minute spray zone test. Cans are sorted in ascending order by measured catch volume.
Can ID Location Description Measured Volume (mL) Converted Depth (in) Lowest 25% Flag Step-by-Step DUlq Audit Summary
Can 12 South Perimeter Near H3 18 mL 0.069 in LQ (Can 1) Step 1: Total Volume & Average
Can 04 West Perimeter Midpoint 20 mL 0.076 in LQ (Can 2) Sum of all 24 catch volumes = 744 mL = 744 \text{ mL} = 744 mL
Can 18 East Outer Edge 21 mL 0.080 in LQ (Can 3) Overall Average Volume ( V ˉ a l l \bar{V}_{all} V ˉ a ll ) = 744 24 = 31.0 mL = \frac{744}{24} = 31.0 \text{ mL} = 24 744 = 31.0 mL
Can 01 North-West Corner 22 mL 0.084 in LQ (Can 4) Overall Average Depth ( D ˉ a l l \bar{D}_{all} D ˉ a ll ) = 31.0 × 0.003814 = 0.1182 in = 31.0 \times 0.003814 = 0.1182 \text{ in} = 31.0 × 0.003814 = 0.1182 in
- Can 09 South-West Corner 23 mL 0.088 in LQ (Can 5)
- Can 15 South Outer Edge 24 mL 0.092 in LQ (Can 6) Step 2: Lowest 25% (Lowest 6 Cans)
Can 22 South-East Corner 26 mL 0.099 in Normal Lowest 6 volumes = 18 + 20 + 21 + 22 + 23 + 24 = 128 mL = 18 + 20 + 21 + 22 + 23 + 24 = 128 \text{ mL} = 18 + 20 + 21 + 22 + 23 + 24 = 128 mL
Can 07 Center-West 28 mL 0.107 in Normal Lowest Quarter Avg Volume ( V ˉ l q \bar{V}_{lq} V ˉ lq ) = 128 6 = 21.333 mL = \frac{128}{6} = 21.333 \text{ mL} = 6 128 = 21.333 mL
Can 03 North Perimeter Midpoint 29 mL 0.111 in Normal Lowest Quarter Avg Depth ( D ˉ l q \bar{D}_{lq} D ˉ lq ) = 21.333 × 0.003814 = 0.0814 in = 21.333 \times 0.003814 = 0.0814 \text{ in} = 21.333 × 0.003814 = 0.0814 in
- Can 11 Center-South 30 mL 0.114 in Normal
- Can 19 Center-East 31 mL 0.118 in Normal Step 3: Calculate DUlq
Can 05 Center Zone Grid 32 mL 0.122 in Normal DU l q = V ˉ l q V ˉ a l l × 100 = 21.333 31.0 × 100 = 68.82 \text{DU}_{lq} = \frac{\bar{V}_{lq}}{\bar{V}_{all}} \times 100 = \frac{21.333}{31.0} \times 100 = 68.82 DU lq = V ˉ a ll V ˉ lq × 100 = 31.0 21.333 × 100 = 68.82 (68.82%)
- Can 13 Center-North 32 mL 0.122 in Normal DUlq = 68.8% (Rating: Good Performance )
- Can 20 North-East Corner 33 mL 0.126 in Normal
- Can 08 Center Overlap 34 mL 0.130 in Normal Step 4: Calculate Scheduling Multiplier
Can 16 East Perimeter Midpoint 35 mL 0.133 in Normal SM = 1 0.4 + 0.6 ( 0.6882 ) = 1 0.4 + 0.4129 = 1 0.8129 = 1.2302 \text{SM} = \frac{1}{0.4 + 0.6(0.6882)} = \frac{1}{0.4 + 0.4129} = \frac{1}{0.8129} = 1.2302 SM = 0.4 + 0.6 ( 0.6882 ) 1 = 0.4 + 0.4129 1 = 0.8129 1 = 1.2302
- Can 02 North Outer Edge 36 mL 0.137 in Normal SM = 1.23 (Run time must be increased by 23%)
- Can 10 South Inner Edge 37 mL 0.141 in Normal
- Can 14 East Inner Edge 37 mL 0.141 in Normal Step 5: Adjusted Operational Run Time
- Can 21 East Overlap 38 mL 0.145 in Normal Base Run Time = 15.0 minutes = 15.0 \text{ minutes} = 15.0 minutes
Can 06 West Overlap 39 mL 0.149 in Normal Adjusted Run Time = 15.0 × 1.2302 = 18.45 minutes = 15.0 \times 1.2302 = 18.45 \text{ minutes} = 15.0 × 1.2302 = 18.45 minutes
- Can 17 South-East Overlap 40 mL 0.153 in Normal Final Controller Run Time = 18.5 minutes
- Can 23 Head 1 Perimeter 41 mL 0.156 in Normal
- Can 24 Head 2 Perimeter 42 mL 0.160 in Normal