Study guide
8.3 Fault Tree Analysis (FTA) vs. Event Tree Analysis (ETA)
PECB Certified ISO 31000 Risk Manager Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Principles and Core Concepts of ISO 31000
1.1 ISO 31000 Overview, Purpose, and Scope 1.2 Core Risk Terminology and Definitions 1.3 The 8 ISO 31000:2018 Risk Management Principles 1.4 The Risk Management Standards Landscape and PECB Exam Structure 1.5 Comparing ISO 31000 with COSO ERM, NIST RMF, and Sector Frameworks 1.6 Risk Categories and Risk Management vs. Risk Assessment
2 Chapter 2: Enterprise Risk Governance and Leadership
2.1 Leadership and Top Management Commitment 2.2 Integrating Risk Management into Organizational Governance 2.3 Building a Risk-Aware Culture and the Three Lines Model
3 Chapter 3: Designing and Implementing the Risk Framework
3.1 Framework Design and Context Analysis 3.2 Framework Implementation and Resource Allocation 3.3 Framework Evaluation and Continual Improvement 3.4 The Risk Management Plan and Framework Documentation Architecture
4 Chapter 4: Establishing Context and Risk Identification
4.1 Communication and Stakeholder Consultation 4.2 Defining Scope, Context, and Risk Criteria 4.3 Risk Identification Methods and Risk Register Construction 4.4 The Consultation Process, Communication Principles, and Risk Escalation 4.5 Asset Identification and Evaluation of Existing Controls
5 Chapter 5: Risk Analysis, Evaluation, and Decision Making
5.1 Risk Analysis: Assessing Likelihood, Consequence, and Controls 5.2 Risk Evaluation and Prioritization 5.3 Inherent Risk vs. Residual Risk and Risk Aggregation
6 Chapter 6: Risk Treatment, Monitoring, and Reporting
6.1 The Seven ISO 31000 Risk Treatment Options 6.2 Designing and Implementing Risk Treatment Plans 6.3 Monitoring, Review, Recording, and Reporting Systems
7 Chapter 7: Qualitative and Scenario Risk Assessment Techniques (IEC 31010)
7.1 IEC 31010 Framework and Selection Criteria 7.2 Qualitative Techniques: Delphi, SWIFT, HAZOP, and Brainstorming 7.3 Root Cause Analysis (RCA), Fishbone, and 5 Whys
8 Chapter 8: Quantitative and Predictive Risk Assessment Techniques (IEC 31010)
8.1 Bow-Tie Analysis: Cause and Consequence Diagramming 8.2 Failure Mode and Effects Analysis (FMEA/FMECA) 8.3 Fault Tree Analysis (FTA) vs. Event Tree Analysis (ETA) 8.4 Advanced Quantitative Methods: Monte Carlo, Decision Trees, and LOPA
8.3 Fault Tree Analysis (FTA) vs. Event Tree Analysis (ETA)
Key Takeaways Explain This Topic AI
Fault Tree Analysis (FTA) is a top-down, deductive technique that uses Boolean AND/OR logic gates to determine all combinations of basic root failures causing a specific Top Event.
Minimal Cut Sets (MCS) represent the smallest combinations of basic events whose simultaneous occurrence forces Top Event realization; single-event cut sets reveal critical single-point vulnerabilities.
Event Tree Analysis (ETA) is a bottom-up, inductive technique that models the chronological success/failure sequence of safety barriers following an Initiating Event.
Combining FTA and ETA enables integrated Cause-Consequence Analysis, where FTA quantifies safety barrier failure probabilities feeding into ETA decision nodes.
Last updated: July 2026
8.3 Fault Tree Analysis (FTA) vs. Event Tree Analysis (ETA)
In the suite of quantitative risk assessment techniques codified in IEC 31010 , Fault Tree Analysis (FTA) and Event Tree Analysis (ETA) represent two complementary, foundational methodologies. While both rely on rigorous probabilistic mathematics, they approach risk modeling from opposite structural directions: FTA is a top-down, deductive methodology focused on root-cause logic, whereas ETA is a bottom-up, inductive methodology focused on chronological consequence progression.
1. Fault Tree Analysis (FTA): Top-Down Deductive Logic
Standardized under IEC 61025 , Fault Tree Analysis begins with an undesired system-level outcome—the Top Event —and deductively reasons backward to identify all possible combinations of component failures, human errors, and environmental conditions (known as Basic Events ) that can cause it.
Boolean Logic Gates
FTA builds visual logic trees using standardized graphical symbols, primarily AND gates and OR gates :
AND Gate : The output event occurs if and only if all input events occur simultaneously.
Probabilistic Equation (Independent Events) : P ( Output ) = P ( E 1 ∩ E 2 ∩ ⋯ ∩ E k ) = ∏ i = 1 k P ( E i ) P(\text{Output}) = P(E_1 \cap E_2 \cap \dots \cap E_k) = \prod_{i=1}^{k} P(E_i) P ( Output ) = P ( E 1 ∩ E 2 ∩ ⋯ ∩ E k ) = i = 1 ∏ k P ( E i )
Interpretation : AND gates represent safety redundancy. Combining independent failure events under an AND gate significantly reduces overall output probability.
OR Gate : The output event occurs if at least one input event occurs.
Probabilistic Equation (Independent Events) : P ( Output ) = 1 − ∏ i = 1 k ( 1 − P ( E i ) ) ≈ ∑ i = 1 k P ( E i ) (for small probabilities) P(\text{Output}) = 1 - \prod_{i=1}^{k} (1 - P(E_i)) \approx \sum_{i=1}^{k} P(E_i) \quad \text{(for small probabilities)} P ( Output ) = 1 − i = 1 ∏ k ( 1 − P ( E i )) ≈ i = 1 ∑ k P ( E i ) (for small probabilities)
Interpretation : OR gates represent single-point vulnerabilities or alternative failure pathways. [AND Gate Logic] [OR Gate Logic]
- E1 AND E2 E1 OR E2
- P = P(E1) * P(E2) P = 1 - (1-P(E1))*(1-P(E2))
- Minimal Cut Sets (MCS)
A central objective of FTA is identifying Minimal Cut Sets (MCS) .
Cut Set : A collection of basic events whose simultaneous occurrence guarantees that the Top Event will occur.
Minimal Cut Set : A cut set that cannot be reduced further without losing its capability to trigger the Top Event.
Order of Cut Sets : The number of basic events in a minimal cut set defines its order. A 1st-order minimal cut set consists of a single basic event—representing a single point of failure for the entire system. System reliability engineers prioritize eliminating 1st-order cut sets by introducing hardware redundancy or procedural separation.
2. Event Tree Analysis (ETA): Bottom-Up Inductive Logic
Standardized under IEC 62502 , Event Tree Analysis is an inductive methodology that begins with a single Initiating Event (e.g., pipe rupture, main power grid trip, cyber firewall breach) and models the chronological sequence of safety barriers, automated safeguards, and operator responses designed to mitigate the event.
Structure of an Event Tree
Initiating Event ( I E IE I E ) : The starting event, assigned an annual frequency ( f I E f_{IE} f I E ).
Safety Functions / Pivotal Events : Arranged horizontally across the top of the tree in chronological order of activation (e.g., System A auto-start → \rightarrow → System B isolation → \rightarrow → Emergency Response).
Branching Decision Nodes : At each safety function, the tree splits into two binary paths:
- Success Branch (Top Path) : Probability = 1 − P F D i = 1 - PFD_i = 1 − PF D i
- Failure Branch (Bottom Path) : Probability = P F D i = PFD_i = PF D i
End Outcomes : Each complete horizontal path through the tree terminates in a distinct outcome scenario ranging from safe shutdown to catastrophic loss.
Outcome Frequency Calculation
The frequency of any specific outcome path ( f p a t h f_{path} f p a t h ) is calculated by multiplying the initiating event frequency ( f I E f_{IE} f I E ) by the conditional probabilities of success or failure at each sequential node along that path: f p a t h = f I E × ∏ Node Probabilities along Path f_{path} = f_{IE} \times \prod \text{Node Probabilities along Path} f p a t h = f I E × ∏ Node Probabilities along Path
The sum of probabilities across all outcome paths originating from a single initiating event must strictly equal 1.0 (100%) .
3. Integrated Cause-Consequence Modeling
In complex industrial and mission-critical applications, FTA and ETA are combined into Cause-Consequence Analysis :
FTA is utilized to derive the failure probabilities ( P F D PFD PF D ) of individual complex safety barriers.
These calculated P F D PFD PF D values are then inserted directly into the binary decision nodes of an ETA .
- Worked Quantitative Integration Example
- Step A: Fault Tree Analysis for Emergency Injection Pump Failure
An Emergency Injection Pump System (Safety Function 1) fails if:
Power fails ( E 1 E_1 E 1 , P ( E 1 ) = 0.04 P(E_1) = 0.04 P ( E 1 ) = 0.04 ) OR Control logic fails ( E 2 E_2 E 2 , P ( E 2 ) = 0.01 P(E_2) = 0.01 P ( E 2 ) = 0.01 ),
AND Mechanical valve jams ( E 3 E_3 E 3 , P ( E 3 ) = 0.05 P(E_3) = 0.05 P ( E 3 ) = 0.05 ).
Calculate OR gate probability for Power/Control failure ( P O R P_{OR} P OR ): P O R = 1 − ( 1 − 0.04 ) ( 1 − 0.01 ) = 1 − ( 0.96 × 0.99 ) = 1 − 0.9504 = 0.0496 P_{OR} = 1 - (1 - 0.04)(1 - 0.01) = 1 - (0.96 \times 0.99) = 1 - 0.9504 = 0.0496 P OR = 1 − ( 1 − 0.04 ) ( 1 − 0.01 ) = 1 − ( 0.96 × 0.99 ) = 1 − 0.9504 = 0.0496
Calculate AND gate probability for Pump System Failure ( P F D P u m p PFD_{Pump} PF D P u m p ): P F D P u m p = P O R × P ( E 3 ) = 0.0496 × 0.05 = 0.00248 PFD_{Pump} = P_{OR} \times P(E_3) = 0.0496 \times 0.05 = 0.00248 PF D P u m p = P OR × P ( E 3 ) = 0.0496 × 0.05 = 0.00248
Step B: Event Tree Analysis with Initiating Event
An initiating power surge occurs with frequency f I E = 1.0 event/year f_{IE} = 1.0 \text{ event/year} f I E = 1.0 event/year . The event tree evaluates two sequential barriers: Safety Barrier 1 (Pump System, P F D = 0.00248 PFD = 0.00248 PF D = 0.00248 ) and Safety Barrier 2 (Manual Relief Valve, P F D = 0.10 PFD = 0.10 PF D = 0.10 ).
Path 1 (Success / Success) : Safe Containment f 1 = 1.0 × ( 1 − 0.00248 ) × ( 1 − 0.10 ) = 1.0 × 0.99752 × 0.90 = 0.897768 /year f_1 = 1.0 \times (1 - 0.00248) \times (1 - 0.10) = 1.0 \times 0.99752 \times 0.90 = 0.897768 \text{ /year} f 1 = 1.0 × ( 1 − 0.00248 ) × ( 1 − 0.10 ) = 1.0 × 0.99752 × 0.90 = 0.897768 /year
Path 2 (Success / Failure) : Controlled Venting f 2 = 1.0 × ( 1 − 0.00248 ) × 0.10 = 1.0 × 0.99752 × 0.10 = 0.099752 /year f_2 = 1.0 \times (1 - 0.00248) \times 0.10 = 1.0 \times 0.99752 \times 0.10 = 0.099752 \text{ /year} f 2 = 1.0 × ( 1 − 0.00248 ) × 0.10 = 1.0 × 0.99752 × 0.10 = 0.099752 /year
Path 3 (Failure / Success) : Degraded Thermal Relief f 3 = 1.0 × 0.00248 × ( 1 − 0.10 ) = 1.0 × 0.00248 × 0.90 = 0.002232 /year f_3 = 1.0 \times 0.00248 \times (1 - 0.10) = 1.0 \times 0.00248 \times 0.90 = 0.002232 \text{ /year} f 3 = 1.0 × 0.00248 × ( 1 − 0.10 ) = 1.0 × 0.00248 × 0.90 = 0.002232 /year
Path 4 (Failure / Failure) : Severe Rupture / Catastrophic Consequence f 4 = 1.0 × 0.00248 × 0.10 = 0.000248 /year ( 2.48 × 10 − 4 /year ) f_4 = 1.0 \times 0.00248 \times 0.10 = 0.000248 \text{ /year} \quad (2.48 \times 10^{-4} \text{ /year}) f 4 = 1.0 × 0.00248 × 0.10 = 0.000248 /year ( 2.48 × 1 0 − 4 /year )
Loading diagram... Integrated FTA (Deductive Root Cause) and ETA (Inductive Barrier Progression)
Comprehensive Comparison: FTA vs. ETA
The table below contrasts the fundamental characteristics of Fault Tree Analysis and Event Tree Analysis:
- Technical Attribute Fault Tree Analysis (FTA) Event Tree Analysis (ETA)
- Analytical Direction Top-down (deductive backward logic) Bottom-up (inductive forward logic)
- Starting Point Undesired Top Event (Loss state) Initiating Event (Trigger/Disruption)
- Core Logical Operator Boolean AND/OR logic gates Binary Success/Failure branch nodes
- Primary Structural Output Minimal Cut Sets & Top Event Probability Scenario Paths & Consequence Frequencies
- Handling Redundancy Explicitly models parallel component gates Evaluates sequential barrier responses
- IEC Standard Reference IEC 61025 IEC 62502