Study guide

1.2 Level I vs Level II Scope and Prerequisites

Certified Infrared Thermographer Level II Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 About the Level II Exam 1.2 Level I vs Level II Scope and Prerequisites

2 Chapter 2: Thermometry Fundamentals

2.1 Temperature Scales and Conversions 2.2 Contact vs Non-Contact Thermometers 2.3 Identifying and Reducing Measurement Errors

3 Chapter 3: Thermal Science and Heat Transfer

3.1 Thermal Science: Temperature, Energy Units, and Heat Capacity 3.2 Heat Transfer Modes and Conduction Variables

4 Chapter 4: Advanced Infrared Theory

4.1 Radiant Power and Stefan-Boltzmann Law 4.2 Planck's Curves and Wien's Displacement Law 4.3 Real Surfaces: Emissivity, Reflectivity, Transmissivity

5 Chapter 5: Emissivity Correction Methods

5.1 Why Emissivity Correction Matters at Level II 5.2 Reference Emitter, Tape, and Paint Methods 5.3 Reflected Apparent Temperature (RAT) Methods 5.4 Emissivity Tables: Metals and Non-Metals

6 Chapter 6: Camera Parameters and Measurement Setup

6.1 The Five Required Camera Parameters 6.2 Atmospheric Temperature, RH, and Distance 6.3 IR Window Transmittance Corrections 6.4 Target Size, IFOV, and Distance-to-Spot Ratio 6.5 Detectors, Optics, and Imager Specifications

7 Chapter 7: Calibration and Advanced Error Sources

7.1 Equipment Calibration and Accuracy Specs 7.2 Cross-Verification with Contact Thermometers 7.3 Filters, Windows, and Spectral Considerations

8 Chapter 8: Severity Classification Standards

8.1 NETA ATS Table 100.18 and Repair-Priority Conventions 8.2 Absolute Temperature Limits (ANSI/IEEE/NEMA) 8.3 ISO 18434 and Machinery Severity Criteria 8.4 Building Envelope Criteria (ASTM C1060 / ISO 6781) 8.5 Load and Ambient Correction of Absolute Limits

9 Chapter 9: Electrical Pattern Analysis

9.1 Three-Phase Electrical Fault Patterns 9.2 Transformer and Switchgear Thermography 9.3 Capacitor, Bus, and Connection Anomalies 9.4 High-Voltage Inspection Conditions and Load Requirements

10 Chapter 10: Mechanical and Steam System Analysis

10.1 Bearing and Rotating Equipment Signatures 10.2 Steam Trap and Steam System Inspection 10.3 Mechanical Drive and Alignment Indicators

11 Chapter 11: Building Envelope Analysis

11.1 Insulation Defects and Thermal Bridging 11.2 Air Infiltration and Blower-Door IR 11.3 Moisture Signatures and Flat Roof Protocols 11.4 Inspection Conditions: ΔT, Wind, and Timing

12 Chapter 12: Trending and Baseline Comparison

12.1 Establishing Baselines and Documentation 12.2 Rate-of-Change and Multi-Inspection Trending 12.3 Escalation Criteria from Trend Data

13 Chapter 13: QA/QC of Level I Work

13.1 Parameter Verification and Coverage Review 13.2 Equipment Identification and Finding Reclassification 13.3 Supervisory Sign-Off Responsibilities

14 Chapter 14: Reporting Standards and Professional Ethics

14.1 Quantitative Report Content Requirements 14.2 Paired Image Documentation and Presentation 14.3 Professional Ethics and Client Communication 14.4 Image Processing and Report Generation Software

1.2 Level I vs Level II Scope and Prerequisites

Key Takeaways Explain This Topic AI

Level I focuses on qualitative or limited quantitative scanning under supervision; Level II owns full quantitative measurement, severity classification, trending, and formal report authorship

Typical Level II prerequisites: documented Level I certification, 32 hours of approved Level II coursework over four days, hands-on camera labs, and success on the issuing body’s exam

Level II adds authority to QA/QC Level I work—verify the five camera parameters, equipment IDs, coverage completeness, and reclassify findings when standards require it

Severity calls (ANSI/NETA Table 100.18 for electrical, ISO 18434 method plus OEM limits for machinery, ASTM C1060 conditions for envelopes) and multi-inspection trend escalation are Level II competencies, not Level I defaults

Prerequisites and scope statements on contracts must match the named training body; field hours alone do not automatically equal Level II quantitative sign-off rights

Last updated: August 2026

Why the Level Boundary Matters

Clients and employers often say “we need a thermographer” as if one credential covers every task. On the exam—and on real jobs—the Level I vs Level II boundary is a competence and liability line. Level I technicians are trained to operate cameras, recognize abnormal patterns, and capture documentation under defined procedures. Level II thermographers are expected to produce quantitative temperatures that survive cross-check, assign severity against standards such as NETA ATS or ISO 18434-1, compare against baselines , QA/QC junior work, and write complete reports with corrective-action recommendations.

Mis-scoping is a common field failure mode: a Level I scanner leaves emissivity at the factory default, reports an “absolute” temperature on shiny bus, and a plant shuts a feeder for a false Priority 1. Level II training exists to prevent that class of error.

Core Definitions

Level I thermographer: Performs qualitative surveys and limited quantitative work as allowed by procedure and supervision. Focus: find anomalies, capture comparable images, follow route lists, flag obvious hazards for higher-level review.

Level II thermographer: Performs full quantitative IR measurement with emissivity and environmental corrections, classifies severity, trends multi-inspection data, supervises/reviews Level I products, and authors formal inspection reports.

Level III (context only): Program design, procedure ownership, advanced analysis leadership—beyond this chapter’s exam focus, but the next career step after Level II mastery.

Side-by-Side Scope Table

  • Task / authority Level I (typical) Level II (expected)
  • Camera operation & focus / range setup Yes Yes
  • Qualitative “hot / normal / investigate” screening Primary role Can perform; also teaches/reviews others

Full emissivity correction (tape, paint, reference emitter, RAT) Introduced; limited independent use Core competency

Set all five camera parameters (ε, RAT, air temp, RH, distance) Follows checklist under guidance Owns correctness

IR window transmittance correction Rare / assisted Expected when windows are in the optical path

ANSI/NETA Table 100.18 classification vs similar component May record ΔT; classification often escalated Applies the published criteria

  • ISO 18434 machinery interpretation Awareness Builds criteria from OEM limits, ratings, and baselines
  • Building envelope ΔT / ASTM C1060 conditions Assists surveys Judges survey validity and defect signatures
  • Baseline & rate-of-change trending Collects data into a system Interprets trends and escalates
  • QA/QC of another inspector’s IR work Not primary Yes — parameter, ID, coverage, reclass

Final quantitative report with recommendations Contributes images/notes Authors / signs quantitative conclusions

  • Mentoring newer thermographers Peer support Formal technical mentorship
  • Prerequisites: What “Ready for Level II” Means

Bodies phrase prerequisites with the same skeleton even when pass scores differ:

Level I certification (or equivalent documented field experience applying Level I methods—only when the body allows that path in writing).

Approved Level II coursework — 32 hours at both Infraspection and ITC — four days — including hands-on camera labs, not lecture-only PDFs.

Field experience applying Level I skills so Level II theory attaches to real equipment, loads, and access constraints.

Passing the Level II exam under that body’s rules ( Infraspection: 80% on the open-book CIT exam; ITC: an electronically administered final exam whose cut score it does not publish — restate each body’s rule, do not blend).

Ongoing practice — skill decay is real; renewal rules follow the issuing body — ITC certification is valid five years , while Infraspection certification does not expire and carries no renewal fee.

Trap: “I have five years of shooting thermograms, so I am Level II.” Time-in-grade without quantitative method training and exam credentialing does not automatically grant Level II report authority on contracts that name a specific certification.

  • What Level II Adds Technically (Exam-Critical)
  • 1) Quantitative radiometry, not palette storytelling

Level II candidates must explain how wrong emissivity or reflected apparent temperature (RAT) moves the reported temperature, how polished metals (ε often 0.05–0.15 ) differ from paints/plastics/water (ε often 0.85–0.98 ), and when a contact thermometer or reference emitter is required to back-calculate ε.

2) Severity standards

Knowing that a lug “looks hot” is Level I intuition. Level II applies structured criteria—for example ANSI/NETA Table 100.18 , whose similar-component column runs 1–3 °C investigate, 4–15 °C repair as time permits, >15 °C repair immediately , and whose ambient column runs 1–10 / 11–20 / 21–40 / >40 °C —and knows the loading rules (NFPA 70B 7.4.4 requires normal circuit loading; 7.4.5 permits not less than 40 percent of nominal when normal load is infeasible).

3) Trending and baselines

A single snapshot can mislead after load changes or ambient shifts. Level II documents comparable conditions, builds baselines, and evaluates rate of change so a creeping P3 does not wait until it becomes a catastrophic P1 without warning.

4) QA/QC of Level I work

Expect exam items on supervisory review:

Were all five parameters set and recorded?

Is equipment identification correct (phase, asset tag, location)?

Was coverage complete for the assigned route?

Must a finding be reclassified after load correction or better ε measurement?

If you cannot articulate those four checks, you are still thinking like a scanner, not a Level II reviewer.

5) Reporting and ethics

Level II reports pair radiometric and visual images, state measurement conditions, show severity with standard citations, and avoid overstating certainty. Ethics items include not altering images to invent heat, not signing work you did not review, and not claiming another body’s credential when the contract requires yours.

Practical Scenarios

Scenario 1 — Wrong level assignment. A supervisor sends only Level I techs to produce “final NETA classifications” for an insurance report. Correct action: Level II (or higher) must classify and sign quantitative severity; Level I can collect under a written procedure but should not own the priority call without review.

Scenario 2 — Prerequisite gap. A candidate schedules the Level II exam without Level I and without an approved experience-equivalency letter. Registration should be blocked until the body’s prerequisite path is satisfied.

Scenario 3 — QA find. Level I data shows ΔT = 38 °C on a connection but ε = 0.95 on bright metal and load was 15% of rating. Level II rework: correct ε/RAT, re-measure at adequate load, then reclassify—possibly dramatically lower severity once measurement is valid.

Scenario 4 — Body language on a résumé. Listing “CIT Level II — never expires, recertify every five years” mixes Infraspection longevity language with the ITC renewal cycle. Clean résumés name the issuing organization and that body’s actual rules.

Study Implications for the Rest of This Guide

Chapters on thermometry, thermal science and heat transfer, Planck/Stefan-Boltzmann theory, emissivity methods, camera parameters, and NETA/ISO/ASTM criteria are not optional enrichment—they are the delta that separates Level I pattern recognition from Level II measurement science. Neither body publishes domain weights, so budget study hours against the two published curricula summarised in Section 1.1, and use practice at /practice/itc-ir-level-2 to force timed decision-making.

Quick Answer: Level I finds and documents thermal anomalies under supervision; Level II corrects radiometric parameters, applies severity and trending standards, QA/QCs Level I products, and owns quantitative reports. Enter Level II only with Level I (or documented equivalent), approved coursework (~40 hours classically), field experience, and a body-specific exam result— Infraspection 80% and non-expiring; ITC five-year validity , with each body’s rules kept separate.