10.1 Bearing and Rotating Equipment Signatures
Certified Infrared Thermographer Level II Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 About the Level II Exam 1.2 Level I vs Level II Scope and Prerequisites
2 Chapter 2: Thermometry Fundamentals
2.1 Temperature Scales and Conversions 2.2 Contact vs Non-Contact Thermometers 2.3 Identifying and Reducing Measurement Errors
3 Chapter 3: Thermal Science and Heat Transfer
3.1 Thermal Science: Temperature, Energy Units, and Heat Capacity 3.2 Heat Transfer Modes and Conduction Variables
4 Chapter 4: Advanced Infrared Theory
4.1 Radiant Power and Stefan-Boltzmann Law 4.2 Planck's Curves and Wien's Displacement Law 4.3 Real Surfaces: Emissivity, Reflectivity, Transmissivity
5 Chapter 5: Emissivity Correction Methods
5.1 Why Emissivity Correction Matters at Level II 5.2 Reference Emitter, Tape, and Paint Methods 5.3 Reflected Apparent Temperature (RAT) Methods 5.4 Emissivity Tables: Metals and Non-Metals
6 Chapter 6: Camera Parameters and Measurement Setup
6.1 The Five Required Camera Parameters 6.2 Atmospheric Temperature, RH, and Distance 6.3 IR Window Transmittance Corrections 6.4 Target Size, IFOV, and Distance-to-Spot Ratio 6.5 Detectors, Optics, and Imager Specifications
7 Chapter 7: Calibration and Advanced Error Sources
7.1 Equipment Calibration and Accuracy Specs 7.2 Cross-Verification with Contact Thermometers 7.3 Filters, Windows, and Spectral Considerations
8 Chapter 8: Severity Classification Standards
8.1 NETA ATS Table 100.18 and Repair-Priority Conventions 8.2 Absolute Temperature Limits (ANSI/IEEE/NEMA) 8.3 ISO 18434 and Machinery Severity Criteria 8.4 Building Envelope Criteria (ASTM C1060 / ISO 6781) 8.5 Load and Ambient Correction of Absolute Limits
9 Chapter 9: Electrical Pattern Analysis
9.1 Three-Phase Electrical Fault Patterns 9.2 Transformer and Switchgear Thermography 9.3 Capacitor, Bus, and Connection Anomalies 9.4 High-Voltage Inspection Conditions and Load Requirements
10 Chapter 10: Mechanical and Steam System Analysis
10.1 Bearing and Rotating Equipment Signatures 10.2 Steam Trap and Steam System Inspection 10.3 Mechanical Drive and Alignment Indicators
11 Chapter 11: Building Envelope Analysis
11.1 Insulation Defects and Thermal Bridging 11.2 Air Infiltration and Blower-Door IR 11.3 Moisture Signatures and Flat Roof Protocols 11.4 Inspection Conditions: ΔT, Wind, and Timing
12 Chapter 12: Trending and Baseline Comparison
12.1 Establishing Baselines and Documentation 12.2 Rate-of-Change and Multi-Inspection Trending 12.3 Escalation Criteria from Trend Data
13 Chapter 13: QA/QC of Level I Work
13.1 Parameter Verification and Coverage Review 13.2 Equipment Identification and Finding Reclassification 13.3 Supervisory Sign-Off Responsibilities
14 Chapter 14: Reporting Standards and Professional Ethics
14.1 Quantitative Report Content Requirements 14.2 Paired Image Documentation and Presentation 14.3 Professional Ethics and Client Communication 14.4 Image Processing and Report Generation Software
10.1 Bearing and Rotating Equipment Signatures
Key Takeaways Explain This Topic AI
Bearing and rotating-equipment IR work is comparative: measure end-shield or housing ΔT against the same machine baseline, a sister unit under similar load, or established program limits—not a single absolute number in isolation
ISO 18434-1 provides a framework for condition monitoring of machines by thermography (severity, measurement practices, and interpretation concepts); Level II still applies correct ε/RAT, load context, and multi-technique confirmation
Classic signatures include elevated end-shield temperature from bearing friction or lubrication problems, asymmetric heating from misalignment or soft foot, and coupling/guard hot spots that may reflect shaft-end or coupling stress
Separate motor electrical/winding patterns from driven-equipment mechanical heat: compare motor DE/NDE bearings, motor body vs load, and document speed, load, lubrication state, and runtime
Painted cast housings are usually high-ε and radiometrically friendly; shiny shafts, polished guards, and stainless nameplates require high-ε patches or qualitative pattern interpretation only
Last updated: August 2026
Mechanical thermography turns friction, inefficiency, and heat flow into spatial temperature maps. Unlike a single-point contact probe on one grease fitting, infrared shows where heat is generated and how it spreads through housings, end shields, couplings, and connected machines. Level II work on bearings and rotating equipment is quantitative when emissivity and setup allow , but always comparative : the same machine over time, identical sister trains, drive end versus non-drive end, or motor versus driven load under documented operating conditions.
This section focuses on thermal signatures of bearings and rotating assemblies, end-shield ΔT practice, lubrication-related heat, misalignment patterns, coupling and guard interpretation, motor-versus-driven logic, and the role of ISO 18434 concepts in a Level II mechanical program.
Why Mechanical IR Works
Friction at rolling elements, inadequate or contaminated lubricant films, misaligned shafts, overloaded belts, and binding seals all convert mechanical energy into heat. That heat conducts into bearing housings, end bells, and frames and then radiates (and convects) to the environment. A thermal imager maps surface temperature. With correct parameters, you can:
- Detect abnormal heat before catastrophic failure
- Rank severity using ΔT against baselines or similar components
- Support trending (Chapter 12) when inspections repeat under similar load
- Direct vibration, ultrasound, or oil analysis to the right machine
IR does not replace vibration analysis for early bearing race defect diagnosis. High-frequency vibration and ultrasound often detect subsurface defects earlier than bulk housing temperature. IR excels at thermal severity , lubrication film problems that generate heat, alignment/coupling stress, and rapid route-based screening of many machines.
ISO 18434 Context (Rotating Machinery Thermography)
ISO 18434 (Condition monitoring and diagnostics of machines — Thermography) is the international standard series that frames how thermography is used in machine condition monitoring. Level II candidates should know the role of the standard even when a specific plant procedure cites a corporate version or vendor guide:
ISO 18434-oriented idea Practical Level II meaning
Thermography as a condition monitoring method IR is one technology in a PdM toolbox, not a standalone “fix for everything”
Defined measurement practices Consistent emissivity, geometry, load, and documentation so results are comparable
Personnel competence Interpreters understand heat transfer, machine construction, and limits of surface temperature
Interpretation and reporting Findings tied to machine ID, operating state, and recommended follow-up
Integration with other CM methods Confirm critical finds with vibration, oil, ultrasound, or OEM limits when needed
Exam items may reference ISO 18434-1 style zones or severity thinking for rotating equipment (relative temperature rise classes used in condition monitoring programs). Your site’s severity chapter (Chapter 8) covers formal zone tables in detail; here the operational rule is: use an adopted program criterion consistently , record load and ambient, and never invent a one-off ΔT rule after the fact to force a priority.
Common program patterns (illustrative—always follow client/OEM standard):
- Comparative rise (example framing) Typical action theme
- Small rise vs baseline/sister unit Continue routine monitoring
- Moderate rise Increase frequency; plan multi-tech check
- Large rise Prioritize maintenance; confirm with vibration/oil
- Extreme / rapid escalation Consider operational risk, safety, and outage planning
Exact numeric bins belong to the written program (and Chapter 8). Level II owns consistent measurement and honest uncertainty , not memorizing a single global number for every bearing in every industry.
- End-Shield and Housing Measurement Practice
- Drive end (DE) and non-drive end (NDE)
Motors and many pumps/fans present end shields (end bells) that enclose bearings. A standard route measurement records temperature (or ΔT to ambient or to a reference point on the frame) at:
- DE bearing housing / end shield — often higher duty when shaft load, coupling, or belt pull is present
- NDE bearing housing / end shield — compares symmetry; NDE may show different loading or cooling
- Motor frame / stator body — helps separate winding/electrical heat from pure bearing friction
Driven equipment bearings (pump, fan, gearbox) — may be hotter or cooler than the motor depending on process load
- Measurement point What it often indicates
- Hot DE, normal NDE, normal frame Coupling, belt, or DE bearing/lubrication issue
- Both ends hot, frame also elevated Overload, ventilation problem, or high ambient process heat
- Frame hot, ends relatively cooler Electrical/winding or cooling-air path issue more than pure bearing friction
- Driven equipment hot, motor ends normal Problem may be on the load side (seal, impeller rub, process)
- One machine hot vs identical sister unit Comparative anomaly worth multi-tech follow-up
- How to take a defensible reading
Identify the machine (tag, photo, nameplate) and note running state : speed, load estimate, product temperature if process-connected, hours since start.
Emissivity — Painted cast iron/aluminum housings are typically high-ε (often ~0.90–0.95). Set ε accordingly. Bare shiny shafts and chrome are not reliable absolute targets without tape/paint.
RAT — Set reflected apparent temperature correctly outdoors or near hot process equipment; reflected heat from steam lines or furnaces can fake hot spots on shiny guards.
Geometry — Fill the measurement area; avoid grazing angles on curved end bells when quantitative ΔT is claimed.
Compare — Same point type on sister units, or DE vs NDE, or today’s reading vs baseline under similar load.
Document ambient air temperature, wind (outdoor), and any temporary covers or insulation.
ΔT definitions matter. “20 °C above ambient” is not the same as “20 °C above the sister motor DE” or “20 °C above this machine’s baseline at 80% load.” Report the reference explicitly.
Lubrication-Related Thermal Signatures
Lubricant forms a film that separates rolling elements and races. Thermal clues include:
Condition Thermal / contextual clues
Insufficient lubricant Elevated bearing housing temperature; may worsen with load/speed; history of long lube interval
- Wrong viscosity / degraded oil Progressive rise vs baseline; oil analysis correlation
- Over-greasing Can raise temperature (churning, seal push-out); often after recent greasing event
- Contamination (water, dirt) Heat plus vibration/ultrasound and oil lab evidence
- Normal break-in or high load Elevated but stable temperature with known process load
Important Level II nuance: A hot bearing after greasing is not automatically “good lubrication.” Over-greasing can increase temperature. Trend before/after lubrication under similar load; coordinate with the lubrication technician’s procedure rather than greasing solely because IR looked warm.
Grease fittings and purge paths may show local warm grease expulsion—useful qualitative clues, not always quantitative targets if fittings are shiny metal.
Misalignment, Soft Foot, and Coupling-Related Heat
Shaft misalignment and soft foot increase bearing loads and coupling stress. Thermal patterns may include:
Elevated temperature at both machines’ near-coupling bearings
Hot coupling region (when visible) or hot coupling guard surfaces heated by convection/radiation from the coupling
- Asymmetric heating around a bearing housing (one side of the end shield warmer)
- Combined IR + high vibration at 1× or 2× running speed (vibration confirms; IR shows thermal cost)
- Pattern Preferential follow-up
- Hot DE bearings on motor and pump Alignment check, coupling inspection
- Hot belt-side bearing only Belt tension/alignment (Section 10.3)
- Hot coupling guard, cool far bearings Inspect coupling under safe procedure; guard may hide the real source
- Sudden step change after maintenance Recheck alignment, soft foot, piping strain
Coupling guards are safety covers. They often block direct view of the coupling. A warm guard indicates heat generation nearby but is a poor emissivity surface if polished. Treat guard temperature as a screening indicator , then plan a controlled inspection (lockout, guard removal per safety rules) or use other CM methods. Never remove guards on running equipment for a better IR shot.
Motors Versus Driven Equipment
A frequent exam and field trap is blaming the motor for heat that originates in the driven machine , or the reverse.
Motor-centric heat
Elevated stator/frame with relatively modest bearing ΔT → electrical load, cooling fan, dirty fins, voltage imbalance (also check electrical IR on connections when safe)
- DE hotter than NDE with coupling load → mechanical load from drive train
- Both bearings hot after long stop-start in high ambient → check ventilation and duty cycle
- Driven-equipment-centric heat
- Pump stuffing box / seal area hot → seal friction, flush issues, process temperature
- Fan bearing hot with cool motor → fan bearing, belt, or wheel issues
- Gearbox case hot → gear mesh load, oil level, cooler effectiveness (Section 10.3)
- Observation Better first hypothesis
- Motor frame 15 °C hotter than usual; DE/NDE mild Cooling or electrical load
- Motor DE 20 °C over sister; frame normal DE bearing, coupling, or belt pull
- Pump bearing hot; motor normal Pump bearing/seal/process
- Entire skid uniformly warm Process fluid or ambient enclosure heat—not necessarily a failed bearing
Always record process fluid temperature for pumps and heat exchangers. A “hot” pump housing may simply track hot product.
Emissivity and Target Selection on Rotating Machines
- Surface IR approach
- Painted housing / end shield High ε; good quantitative point if large enough
- Cast iron (oxidized, unpainted) Moderately high ε; verify or use comparative ΔT
- Polished shaft Low ε; use high-ε tape only if safe and allowed; else qualitative
- Stainless or aluminum guard Often reflective; pattern only or tape
- Nameplate / shiny bolts Avoid for absolute T
For trending programs, mark permanent high-ε spots (paint dots or approved tape locations) so every tech measures the same point.
Inspection Conditions and Safety
Survey under representative load . Idle machines hide friction heat.
Allow thermal equilibrium after start-up when the program requires steady state (many bearings need tens of minutes to hours depending on size).
Respect rotating equipment hazards : coupling guards, belts, shafts, loose clothing, and arc-flash rules if electrical panels are opened in the same tour.
Outdoor machines: sun load can heat housings nonuniformly—note solar condition or survey in shade/evening when absolute comparisons matter.
Do not interpret a single hot pixel on a bolt head without context; use area tools on the housing mass.
Multi-Technique Confirmation
Level II reports gain credibility when thermal severity triggers the right next method:
- IR finding Strong companions
- Rising bearing housing ΔT Vibration overall + spectra; ultrasound; grease/oil analysis
- Suspected misalignment heat Laser alignment; vibration phase/orbit clues
- Suspected lubrication issue Oil analysis; grease quantity history; ultrasound friction
- Motor frame heat Electrical IR, current balance, cooling inspection
If vibration is normal and IR is high, still investigate lubrication, process heat, and measurement error before dismissing either technology.
Common Traps
- Trap Correct Level II view
- Absolute 60 °C “always fail” for every bearing Use comparative criteria + OEM/process context
- Trusting shiny shaft temperatures Fix ε or use housing points
- Greasing every hot bearing immediately Diagnose; over-greasing can worsen heat
- Ignoring load and sister-unit comparison Comparative CM is the standard
- Removing guards while running for IR Never—safety first
- Claiming IR replaces all vibration work Complementary, not total replacement
- Summary for Recall
Bearing and rotating-equipment thermography is comparative heat mapping under known load, guided by program criteria and ISO 18434-style condition-monitoring practice. Measure DE/NDE end shields and housings with correct ε/RAT; interpret lubrication, misalignment, and coupling-guard patterns carefully; separate motor electrical heat from driven mechanical heat; and confirm critical findings with vibration, oil, or ultrasound. Pretty color images without load context, emissivity discipline, and a defined reference are not Level II mechanical analysis.