Study guide
14.4 Image Processing and Report Generation Software
Certified Infrared Thermographer Level II Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 About the Level II Exam 1.2 Level I vs Level II Scope and Prerequisites
2 Chapter 2: Thermometry Fundamentals
2.1 Temperature Scales and Conversions 2.2 Contact vs Non-Contact Thermometers 2.3 Identifying and Reducing Measurement Errors
3 Chapter 3: Thermal Science and Heat Transfer
3.1 Thermal Science: Temperature, Energy Units, and Heat Capacity 3.2 Heat Transfer Modes and Conduction Variables
4 Chapter 4: Advanced Infrared Theory
4.1 Radiant Power and Stefan-Boltzmann Law 4.2 Planck's Curves and Wien's Displacement Law 4.3 Real Surfaces: Emissivity, Reflectivity, Transmissivity
5 Chapter 5: Emissivity Correction Methods
5.1 Why Emissivity Correction Matters at Level II 5.2 Reference Emitter, Tape, and Paint Methods 5.3 Reflected Apparent Temperature (RAT) Methods 5.4 Emissivity Tables: Metals and Non-Metals
6 Chapter 6: Camera Parameters and Measurement Setup
6.1 The Five Required Camera Parameters 6.2 Atmospheric Temperature, RH, and Distance 6.3 IR Window Transmittance Corrections 6.4 Target Size, IFOV, and Distance-to-Spot Ratio 6.5 Detectors, Optics, and Imager Specifications
7 Chapter 7: Calibration and Advanced Error Sources
7.1 Equipment Calibration and Accuracy Specs 7.2 Cross-Verification with Contact Thermometers 7.3 Filters, Windows, and Spectral Considerations
8 Chapter 8: Severity Classification Standards
8.1 NETA ATS Table 100.18 and Repair-Priority Conventions 8.2 Absolute Temperature Limits (ANSI/IEEE/NEMA) 8.3 ISO 18434 and Machinery Severity Criteria 8.4 Building Envelope Criteria (ASTM C1060 / ISO 6781) 8.5 Load and Ambient Correction of Absolute Limits
9 Chapter 9: Electrical Pattern Analysis
9.1 Three-Phase Electrical Fault Patterns 9.2 Transformer and Switchgear Thermography 9.3 Capacitor, Bus, and Connection Anomalies 9.4 High-Voltage Inspection Conditions and Load Requirements
10 Chapter 10: Mechanical and Steam System Analysis
10.1 Bearing and Rotating Equipment Signatures 10.2 Steam Trap and Steam System Inspection 10.3 Mechanical Drive and Alignment Indicators
11 Chapter 11: Building Envelope Analysis
11.1 Insulation Defects and Thermal Bridging 11.2 Air Infiltration and Blower-Door IR 11.3 Moisture Signatures and Flat Roof Protocols 11.4 Inspection Conditions: ΔT, Wind, and Timing
12 Chapter 12: Trending and Baseline Comparison
12.1 Establishing Baselines and Documentation 12.2 Rate-of-Change and Multi-Inspection Trending 12.3 Escalation Criteria from Trend Data
13 Chapter 13: QA/QC of Level I Work
13.1 Parameter Verification and Coverage Review 13.2 Equipment Identification and Finding Reclassification 13.3 Supervisory Sign-Off Responsibilities
14 Chapter 14: Reporting Standards and Professional Ethics
14.1 Quantitative Report Content Requirements 14.2 Paired Image Documentation and Presentation 14.3 Professional Ethics and Client Communication 14.4 Image Processing and Report Generation Software
14.4 Image Processing and Report Generation Software
Key Takeaways Explain This Topic AI
Emissivity, reflected apparent temperature, distance, atmospheric values and transmittance can all be corrected in post-processing — but only if the image was saved as a radiometric file rather than a screenshot
Focus, framing, thermal range selection, lens choice and whether the file is radiometric at all cannot be fixed afterwards; these are capture-time decisions
Infraspection Section 9.1 requires every report to carry the thermographer's name and valid certification level and number, the end user's details, assistant names, and the imager's manufacturer, model and serial number
Quantitative reports additionally require distance to the exception, rated and measured load, percentage load, and the emittance, reflected temperature and transmittance values used in the calculation
Report generation software should link findings to history for trending, but a template never substitutes for the thermographer's judgement on severity and recommended action
Last updated: August 2026
Infraspection's Level II curriculum ends with Preparing Quantitative Reports , and it names four sub-topics: data to gather, report procedures, image processing software capabilities , and report generation software capabilities . ITC's outline includes an Overview of Inspection Report Creation and a software training block. A Level II thermographer who cannot say what software can and cannot fix is not ready to sign quantitative work.
What Image Processing Software Can Fix
A radiometric image stores the raw detector signal for every pixel plus the parameters in force at capture. Because the raw signal is preserved, the temperature calculation can be re-run later with better inputs.
- Parameter Correctable after capture? Note
- Emissivity (ε) Yes The most common and most valuable correction
- Reflected apparent temperature Yes Re-enter a properly measured RAT from Chapter 5
- Distance to target Yes Feeds the atmospheric transmission model
- Atmospheric temperature and relative humidity Yes Same model
- External optics / IR window transmittance (τ) Yes If the software exposes an external-optics field
- Palette and colour scheme Yes Cosmetic
- Level and span (thermal tuning) Yes Re-tune for contrast on a radiometric file
- Spot, area, line and isotherm measurement tools Yes Add or move analysis objects
- Image fusion / blending with the visual image Yes If both were captured
This is exactly the capability that makes the Chapter 13 QA/QC process possible: when a Level I technician leaves ε at 0.95 on oxidised copper, a Level II reviewer can reprocess the original file with the correct ε and reflected temperature and recalculate the temperature rather than sending a crew back to site.
What Software Cannot Fix
Not correctable Why
Focus Defocus averages radiation across pixels; the lost detail is not recoverable, and an out-of-focus radiometric measurement is simply wrong
Framing and composition What was outside the field of view was never recorded
Whether the file is radiometric A screenshot, JPEG export, or photo of a screen contains display colours, not detector data. No parameter can be changed afterwards
Measurement range selection A target above the selected range saturates; saturated pixels carry no recoverable value
Spot size / MFOV violations If the target did not fill the measurement field of view, the pixel averaged target and background, and that mixture cannot be unmixed
- Lens actually fitted Optical resolution is set at capture
- Whether a similar reference component was imaged You cannot create a comparison that was never captured
Focus deserves emphasis. It is a genuine radiometric error, not an aesthetic one. Infraspection Section 8.7.1 requires that "every effort shall be made to ensure the thermal image is in sharp focus." An unfocused thermogram cannot be rescued by any amount of post-processing.
The one-line rule: radiometric parameters are soft; optics, focus, framing, range, and geometry are hard.
Required Report Content
Infraspection Section 9 sets out what a report must contain. Treat this as a checklist — items appear directly as exam content.
For every inspection (Section 9.1)
- Item Clause
- Name and valid certification level(s) and number(s) of the thermographer 9.1.1
- Name and address of the end user 9.1.2
- Name(s) of the assistant(s) who accompanied the thermographer 9.1.3
- Manufacturer, model and serial number of the infrared equipment used 9.1.4
- List of all equipment inspected, and notation of equipment not inspected 9.1.5
- Date(s) of inspection and date the report was prepared 9.1.6
- For each exception, qualitative inspections (Section 9.2)
- Exact location of the exception
Description including nameplate data, phase or circuit number, rated voltage, amperage rating and/or rotation speed
- Environmental conditions where significant: air temperature, wind speed and direction, sky conditions
- Thermogram and corresponding visible-light image
- Field of view of the imager lens
- Notation of any windows, filters or external optics used
- Optionally, the qualified assistant's or end user's subjective rating of importance
- Any other conditions affecting results, repeatability, or interpretation
- Additional for quantitative inspections (Section 9.3)
- Distance from the imager to the exception
- Maximum rated load and measured load at the time of inspection
- Percentage load , calculated as measured ÷ rated
- The emittance, reflected temperature and transmittance values used to calculate the temperature
When using ΔT criteria: the surface temperature of the exception, of the defined reference, and their difference
- When using absolute criteria: the surface temperature and the standard temperature(s) referenced
- Optionally, a temperature severity evaluation and a repair priority rating
Section 9.3.3 is the clause that makes reports auditable: recording the ε, RAT and τ actually used means a reviewer can reprocess the radiometric file and verify your number. Omit it and no one — including a court — can check your work.
What Report Generation Software Should Do
- Capability Value
- Template enforcement Guarantees the Section 9 fields are present on every finding
Metadata auto-population Pulls camera model, serial, date, lens, ε, RAT and distance straight from the radiometric file, removing transcription errors
Paired image layout Places thermogram and visible image side by side as required
Asset linkage and history Ties each finding to an asset ID so the trending of Chapter 12 is possible across surveys
- Criteria library Applies the chosen ΔT or absolute criteria set consistently and records which one was used
- Batch processing Handles large route inventories without hand-editing each entry
- Export to the maintenance system Turns findings into work orders
Infraspection publishes its own tools in this category, and every major camera vendor ships an analysis and reporting package. The specific product is not the exam point; the capabilities are.
Where software stops
Software can enforce completeness. It cannot supply judgement. It will not decide whether a reference component was genuinely comparable, whether the survey met loading requirements, whether a pattern is a reflection, or whether an exception warrants immediate action. Infraspection Section 4.2 is blunt about the boundary: providing opinions about causes, system integrity, or corrective actions "requires knowledge and skills beyond those of infrared thermography." A template that auto-generates a recommendation you did not evaluate is a liability, not a feature.
Practical Workflow
Capture radiometric files, in focus, with adequate MFOV, and shoot the visible-light image at the same time.
Record on site what software cannot recover: load, ambient, wind, sky, distance, lens, windows and filters.
Post-process ε, RAT, distance, humidity and τ from measured values, not defaults.
Apply the chosen criteria set and name it.
Assemble against the Section 9 checklist.
Review — ideally a second Level II reads the report before issue.
Archive the original radiometric files, not just the report PDF, so future surveys can trend against genuine data.
Quick Answer: Radiometric files allow post-capture correction of emissivity, reflected temperature, distance, humidity and transmittance ; focus, framing, range, lens and spot-size violations are permanent , and a non-radiometric screenshot allows no correction at all. Reports must carry the thermographer's certification level and number, the imager's make, model and serial, the equipment list, and — for quantitative work — distance, rated and measured load, percentage load, and the ε, RAT and τ values used . Software enforces completeness; the thermographer supplies the judgement.