2.1 Temperature Scales and Conversions
Certified Infrared Thermographer Level II Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 About the Level II Exam 1.2 Level I vs Level II Scope and Prerequisites
2 Chapter 2: Thermometry Fundamentals
2.1 Temperature Scales and Conversions 2.2 Contact vs Non-Contact Thermometers 2.3 Identifying and Reducing Measurement Errors
3 Chapter 3: Thermal Science and Heat Transfer
3.1 Thermal Science: Temperature, Energy Units, and Heat Capacity 3.2 Heat Transfer Modes and Conduction Variables
4 Chapter 4: Advanced Infrared Theory
4.1 Radiant Power and Stefan-Boltzmann Law 4.2 Planck's Curves and Wien's Displacement Law 4.3 Real Surfaces: Emissivity, Reflectivity, Transmissivity
5 Chapter 5: Emissivity Correction Methods
5.1 Why Emissivity Correction Matters at Level II 5.2 Reference Emitter, Tape, and Paint Methods 5.3 Reflected Apparent Temperature (RAT) Methods 5.4 Emissivity Tables: Metals and Non-Metals
6 Chapter 6: Camera Parameters and Measurement Setup
6.1 The Five Required Camera Parameters 6.2 Atmospheric Temperature, RH, and Distance 6.3 IR Window Transmittance Corrections 6.4 Target Size, IFOV, and Distance-to-Spot Ratio 6.5 Detectors, Optics, and Imager Specifications
7 Chapter 7: Calibration and Advanced Error Sources
7.1 Equipment Calibration and Accuracy Specs 7.2 Cross-Verification with Contact Thermometers 7.3 Filters, Windows, and Spectral Considerations
8 Chapter 8: Severity Classification Standards
8.1 NETA ATS Table 100.18 and Repair-Priority Conventions 8.2 Absolute Temperature Limits (ANSI/IEEE/NEMA) 8.3 ISO 18434 and Machinery Severity Criteria 8.4 Building Envelope Criteria (ASTM C1060 / ISO 6781) 8.5 Load and Ambient Correction of Absolute Limits
9 Chapter 9: Electrical Pattern Analysis
9.1 Three-Phase Electrical Fault Patterns 9.2 Transformer and Switchgear Thermography 9.3 Capacitor, Bus, and Connection Anomalies 9.4 High-Voltage Inspection Conditions and Load Requirements
10 Chapter 10: Mechanical and Steam System Analysis
10.1 Bearing and Rotating Equipment Signatures 10.2 Steam Trap and Steam System Inspection 10.3 Mechanical Drive and Alignment Indicators
11 Chapter 11: Building Envelope Analysis
11.1 Insulation Defects and Thermal Bridging 11.2 Air Infiltration and Blower-Door IR 11.3 Moisture Signatures and Flat Roof Protocols 11.4 Inspection Conditions: ΔT, Wind, and Timing
12 Chapter 12: Trending and Baseline Comparison
12.1 Establishing Baselines and Documentation 12.2 Rate-of-Change and Multi-Inspection Trending 12.3 Escalation Criteria from Trend Data
13 Chapter 13: QA/QC of Level I Work
13.1 Parameter Verification and Coverage Review 13.2 Equipment Identification and Finding Reclassification 13.3 Supervisory Sign-Off Responsibilities
14 Chapter 14: Reporting Standards and Professional Ethics
14.1 Quantitative Report Content Requirements 14.2 Paired Image Documentation and Presentation 14.3 Professional Ethics and Client Communication 14.4 Image Processing and Report Generation Software
2.1 Temperature Scales and Conversions
Key Takeaways Explain This Topic AI
Celsius and Fahrenheit are relative (interval) scales; Kelvin and Rankine are absolute scales starting at absolute zero
Convert with °F = (°C × 9/5) + 32, °C = (°F − 32) × 5/9, K = °C + 273.15, and °R = °F + 459.67
Radiometric and Stefan–Boltzmann calculations require absolute temperature (K or °R), never Celsius or Fahrenheit directly
A 1 °C difference equals 1 K and 1.8 °F (or 1.8 °R)—convert ΔT by the degree-size ratio only, without adding 32 or 273
Level II reports must state units clearly; NETA ΔT and ASHRAE envelope criteria often use °C or °F depending on the standard
Last updated: August 2026
2.1 Temperature Scales and Conversions
Quick Answer: Infrared thermographers work daily in °C and °F for reporting, but quantitative radiation laws use absolute scales—Kelvin (K) or Rankine (°R). Convert with °F = (°C × 9/5) + 32, °C = (°F − 32) × 5/9, K = °C + 273.15, and °R = °F + 459.67. Never plug Celsius or Fahrenheit directly into T⁴ power calculations.
Temperature is the physical quantity that thermography exists to measure, yet many Level I operators treat the camera’s number as a self-evident fact. Level II work demands more: you must convert scales fluently, know when a reading is on a relative versus absolute scale, and recognize how unit choice affects ΔT severity tables, baseline trending, and any calculation involving radiant power.
Relative Scales: Celsius and Fahrenheit
Celsius (°C) and Fahrenheit (°F) are relative (interval) scales . Their zeros are historical conventions, not the complete absence of thermal energy:
Celsius sets 0 °C at the freezing point of water and 100 °C at the boiling point of water at standard atmospheric pressure.
Fahrenheit sets 32 °F at water freeze and 212 °F at water boil under the same conditions, so the interval between freeze and boil is 180 °F degrees.
Because the zero points are arbitrary, a value of “0” on either scale does not mean “no heat.” A steel bus bar at 0 °C still radiates infrared energy. For trend work and severity classification, relative scales are fine—as long as every reading and every standard uses the same scale.
Conversion Formulas (Memorize Both Directions)
- Direction Formula Memory aid
- °C → °F °F = (°C × 9/5) + 32 Multiply by 1.8, then add 32
- °F → °C °C = (°F − 32) × 5/9 Subtract 32, then multiply by 5/9 (~0.556)
- °C → K K = °C + 273.15 Often rounded to +273 in field estimates
- °F → °R °R = °F + 459.67 Often rounded to +460 in field estimates
- K → °R °R = K × 9/5 Same ratio as °C/°F degree size
- °R → K K = °R × 5/9 Inverse of above
Interval rule (critical for ΔT work): A temperature difference of 1 °C equals a difference of 1 K, and a difference of 1 °F equals a difference of 1 °R. Converting a delta does not add or subtract 32 or 273:
- ΔT_°F = ΔT_°C × 9/5
- ΔT_°C = ΔT_°F × 5/9
Example: NETA-style Priority 3 often cites an >10–20 °C rise versus a similar component under load. That band is 19.8–36 °F , not “11–20 plus 32.”
Absolute Scales: Kelvin and Rankine
Kelvin (K) and Rankine (°R) are absolute thermodynamic scales . Zero on either scale is absolute zero —the theoretical point of minimum thermal energy (−273.15 °C or −459.67 °F). Absolute scales have no negative values in normal engineering practice.
- Scale Zero point Degree size matches Common IR use
- Kelvin (K) Absolute zero Same as °C Radiometry, Planck, Stefan–Boltzmann
- Rankine (°R) Absolute zero Same as °F Some U.S. engineering texts
- Celsius (°C) Water freeze Same as K Reports, NETA ΔT, most cameras
- Fahrenheit (°F) (offset) water freeze Same as °R U.S. building / facilities reports
Why absolute scales matter in infrared:
Stefan–Boltzmann law states that total radiant exitance of a blackbody scales with T⁴ where T is absolute temperature. Using 80 °C instead of 353 K produces a wildly wrong power estimate.
Wien’s displacement law relates peak wavelength to absolute temperature (λ_max · T ≈ constant).
Object–background contrast in quantitative models depends on absolute temperatures of the target and surroundings, not on whether the display is set to °C or °F.
Level II cameras still display °C or °F because those are readable for humans. Internally, radiometric engines convert to absolute temperature for calculations. Your job is to know when the report, the spreadsheet, or a hand calculation must switch to K or °R.
- Worked Examples Relevant to IR Work
- Example 1 — Motor winding hotspot (report units)
A Level I report lists a motor connection at 185 °F . The client’s maintenance standard is written in Celsius. Convert:
°C = (185 − 32) × 5/9 = 153 × 5/9 = 85 °C (exactly).
If a similar phase connection runs at 70 °C, ΔT = 15 °C = 15 × 1.8 = 27 °F . Severity tables must use one consistent scale for both the reading and the criterion.
Example 2 — Absolute temperature for radiation comparison
Two surfaces measure 40 °C and 80 °C . Naively, 80 looks “twice” 40 on a relative scale—but radiation scales with absolute temperature to the fourth power.
- T₁ = 40 + 273.15 = 313.15 K
- T₂ = 80 + 273.15 = 353.15 K
- Ratio of blackbody exitance ≈ (353.15 / 313.15)⁴ ≈ (1.128)⁴ ≈ 1.62
The hotter surface radiates about 62% more power as a blackbody, not “twice as much.” Level II quantitative thinking starts with this conversion habit.
Example 3 — Ambient and reflected ambient on mixed-unit jobs
You measure reflected apparent temperature (RAT) with crumpled aluminum foil as 72 °F . Your camera’s atmospheric-temperature field is set in Celsius. Convert before entry:
°C = (72 − 32) × 5/9 = 22.2 °C .
Entering 72 into a °C field would force the camera’s atmospheric and reflected corrections into nonsense territory and can shift indicated target temperatures by several degrees—especially on low-emissivity metals.
Example 4 — Building envelope ΔT (ASHRAE-style condition)
A common rule of thumb for meaningful building-envelope IR is roughly 10 °C (18 °F) interior-to-exterior air temperature difference. If outdoor air is 35 °F and you need at least an 18 °F ΔT, indoor air should be about 53 °F or higher for a heating-season survey—or you wait for colder weather. Confusing the 10 °C criterion with “10 °F” understates the required gradient by almost half and can produce false “no problem” surveys.
Choosing Units on Level II Deliverables
Context Preferred unit Notes
Electrical NETA-style ΔT tables (many U.S. practices) °C (sometimes dual) Confirm client standard; never mix in one table
- U.S. facilities / HVAC client reports Often °F Dual-unit (°C / °F) improves clarity
- Scientific radiometry, research, camera SDK math K Required for T⁴ and Planck functions
- International manufacturing / ISO-oriented plants °C Default SI reporting
Steam systems (gauge vs absolute pressure context) °C or °F for temp Do not confuse temperature scale with pressure “psia/psig”
Professional habit: State the unit on every annotated image, every table column header, and every severity call. “Hotspot = 95” is not a quantitative finding.
Common Conversion Traps on the Exam and in the Field
Adding 32 to a ΔT — Differences convert by the 9/5 factor only.
Using °C in T⁴ — Always convert to kelvin (or rankine) first.
Camera unit mismatch — Emissivity is unitless, but RAT, atmospheric temperature, and ambient fields inherit the camera’s selected scale.
Rounding absolute zero — +273 or +460 is acceptable for rough field estimates; use 273.15 / 459.67 for report-grade hand calcs.
Negative Celsius outdoors — Valid on relative scales; convert carefully (e.g., −10 °C = 14 °F = 263.15 K).
Practice Drill (Mental Fluency)
Work these until they are automatic:
- Given Find
- 100 °C 212 °F, 373.15 K
- 0 °F −17.8 °C, 255.4 K
- 25 °C ambient 77 °F
- ΔT = 35 °C (Priority 1 style threshold in some NETA tables) ΔT = 63 °F
- 300 K scene 26.85 °C ≈ 80.3 °F
Level II competence is not memorizing trivia—it is refusing to let unit confusion corrupt severity classification, camera parameters, or radiation math.
Summary for Level II
Temperature scales are the language of thermometry. Relative scales (°C, °F) dominate client communication and ΔT criteria. Absolute scales (K, °R) dominate physics. Convert differences with the degree-size ratio alone; convert absolute values with the full offset formulas; and always declare units on quantitative infrared work.