1 Exam Overview

Well Control Incidents and Their Consequences Qualification, Assessment and Study Planning

2 Hydrostatic Pressure and the Circulating System

Hydrostatic Pressure, Fluid Gradients, and Mud Weight Multiple Fluid Columns and Inverse Hydrostatic Calculations U-Tube Principle, Dynamic Pressure Losses, and Equivalent Circulating Density

3 Formation Pressure and Integrity Limits

Formation Pore Pressure, Normal vs Abnormal Pressure, and Fracture Gradient LOT/FIT Graphs and the Pressure Window MAASP, Kick Tolerance, and Formation Breakdown

4 Barriers and Risk Management

Well Barrier Concepts: Primary, Secondary, and Composite Envelopes Barrier Verification, Monitoring, and Life Cycle Management Well Control Risk Assessment, Human Factors, and Management of Change

5 Fluid Density and Circulation Data

Insufficient Mud Density & Encountering Abnormal Pressures Barite Weighting and Pump-Pressure Changes Pre-Recorded Data, Pump Output, and Slow Circulating Rates

6 Trip Preparation and Pressure Support

Swabbing and Surging During Tripping Operations Slugs, Trip Margin and Pumping Out Unfilled-Hole Limits and Tubular Displacement

7 Trip Monitoring and Connections

Hole Fill Failure and Trip Tank Monitoring Procedures Trip Tanks, PVT Systems, and Flow Return Sensors Kick Indicators During Tripping, Connections, and Out of Hole

8 Kick Warnings and Indicators

Flow Checks and Drilling Breaks Primary Kick Indicators While Drilling Lost Circulation and Loss of Hydrostatic Head

9 Influx Characteristics and Behaviour

Influx Types (Gas, Oil, Salt Water) & Influx Density Determination Gas Solubility in Oil-Based Mud vs Water-Based Mud

10 Gas Expansion and Closed-Well Migration

Gas Physics: Boyle's Law, Expansion, and Migration Velocities Gas Migration in a Shut-In Well & Pressure Buildup Effects

11 Surface Shut-In and Pressure Interpretation

Hard Shut-In vs Soft Shut-In Philosophies & Principles Surface BOP Shut-In Protocols (Drilling, Tripping, Wireline/Out of Hole) Post Shut-In Pressure Stabilization & Data Recording

12 Subsea, Wireline and Stripping Response

Subsea BOP Shut-In Protocols & Space-Out Procedures Wireline Displacement and Pressure-Control Equipment Annular and Ram-to-Ram Stripping

13 Kill-Sheet Calculations

Calculating Kill Mud Weight, ICP, and FCP Drill String/Annular Volumes, Strokes to Bit, and Circulating Times

14 Circulating Kill Methods

The Driller's Method: Detailed Two-Circulation Procedure The Wait and Weight Method & Step-Down Pressure Graphs Comparison of Constant Bottomhole Pressure Methods

15 Special Pressure-Control Methods

Volumetric Method, Lubricate and Bleed, and Bullheading Subsea CLF: Startup, Shutdown and Fluid Displacement

16 Casing and Cementing Well Control

Running Casing: Floats, Clearances and Volumes Cementing: Pressure Profile and Barrier Quality Casing Shut-In and Assembly Readiness

17 Drills and Equipment First Actions

Well Control Drills and Operational Checklists Gauge Failure and BOP Leak First Actions Bit Nozzle Plugging and Mud Pump Failure During a Kill

18 Operational Contingencies

Drill String Washout and Parted Pipe Management Severe Lost Circulation and Underground Blowout Scenarios Gas at Surface, Hydrate Formation, and Diverter Operations

19 Preventer Capabilities

Annular Preventers: Design, Operation, and Stripping Use Pipe Rams and Variable Bore Rams (VBRs) Blind Rams, Shear Rams, and Casing Shear Rams

20 Stack, Connections and Flow Routes

Surface BOP Stack Arrangements, API Specifications, and Outlets Ram Locking Mechanisms and Wellhead Connectors Choke and Kill Lines, Valves, and Pressure Ratings Choke Manifolds, Remote Chokes, and Manual Adjustable Chokes

21 Diverters and Auxiliary Equipment

Shallow Gas and Diverter Response Mud/Gas Separators (Poor Boy Degassers): Liquid Seal & Blow-Through Vacuum Degassers, Desanders, Desilters, and Rig Gas Detectors Drill String Safety Valves, Gray Valves, and Float Valves

22 Hydraulic Control Systems

Accumulator Unit Components: Reservoir, Fluid, and Pumps Accumulator Bottles, Nitrogen Precharge, and Operating Pressures Regulators, Pilot Circuits, and Manifold/Annular Pressure Control Stored Capacity, Accumulator Drawdown Tests and Remote Panels

23 Testing and Subsea Systems

Low-Pressure and High-Pressure BOP Testing Criteria Function Testing, Test Frequencies, and Test Tools Subsea BOP Architecture, LMRP, MUX Control, and Choke Line Friction Subsea Riser Margin, Gas in Riser, and Emergency Disconnect

Surface BOP Shut-In Protocols (Drilling, Tripping, Wireline/Out of Hole)

Key Takeaways Explain This Topic AI

Use the posted shut-in procedure and current stack/string space-out reference.

Tripping requires a compatible internal barrier as well as annular closure.

Empty-hole sealing capability is model-specific, with the designated rated device used.

Verify containment and preserve barriers when connecting a pressure-reading route.

Last updated: October 2026

Prepare for the actual operation

The surface shut-in procedure must fit drilling, tripping, an empty hole or another operation. Before starting, verify the stack configuration, space-out reference, pressure ratings, internal valves, choke route and pressure-monitoring path. Know which element can seal the tubular currently in the stack. A pipe ram fitted for one diameter cannot be credited with sealing another, and a tool joint above the rotary table does not alone establish the position of joints across all BOP cavities.

The following duties explain the hard shut-in principle. The exact control order is taken from the posted procedure and the assessment instructions. For shallow gas where containment is unsuitable, use the approved diverter response instead. The objective is to limit influx while establishing and verifying the whole pressure envelope.

Drilling on bottom

Recognise the unexplained gain, increased returns or other influx indication, suspend drilling and communicate or alarm as instructed. Stop rotation before positioning the string. Pick up and space out from the verified stack reference so the selected element is on qualified pipe body. Stop pumps as directed, avoiding an unnecessary extended flow check when an influx is already evident. Close the designated annular or ram and operate the required side-outlet route against the prepared closed choke.

Check the selected function, panel and hydraulic response, well flow and pressure-monitoring route. Observe for external leakage and continued unplanned flow. If containment is not achieved, activate the planned second barrier. Record the operation, depth, density, pit gain and pressure trends and hand over to the supervisor. Do not substitute an estimated stabilisation time for observed valid readings.

Tripping with the string in the hole

Stop movement and secure the string using the appropriate handling arrangement. Use the prepared internal safety valve compatible with the connection and pressure duty. Where a manual full-opening valve is used, it is prepared open for installation, made up and closed under the instructed procedure. Flow through it during installation is a hazard to manage, not harmless spill. If pressure or flow prevents safe manual installation, use the preplanned alternative.

Close the designated annular or ram on a qualified section, establish the intended choke/gauge route and verify containment. The inside and annulus are separate flow paths, so both must be addressed. A float valve may limit internal backflow but does not prevent an annular influx or prove that the displayed pressure above it is valid SIDPP.

To obtain drillpipe pressure later, connect a verified pressure-rated route as instructed. Reopening the internal safety valve is a controlled barrier transfer requiring known pressure and valve status above it. Do not open it simply to “get a reading” into an unverified assembly. Preserve the internal barrier until the alternative containment route is demonstrated.

String completely out of the hole

Use the designated device qualified to seal the empty bore, normally the applicable blind or blind/shear ram arrangement. Some annular models have complete-shutoff capability, with manufacturer-specific pressure and element limits, so “an annular can never seal an empty hole” is incorrect. The installed procedure determines the element used, including its verification and alternative.

There is no drillstring pressure reference if no string is in the well. Record casing pressure, fluid profile and volume information. The subsequent plan may require volumetric control, controlled re-entry or another supervised method. Running pipe rapidly into a flowing well is not a substitute for containment. A string re-entry plan needs suitable barriers and a qualified stripping arrangement.

Other assemblies and wireline

Casing, cementing and wireline have operation-specific procedures because their internal routes and sealing dimensions differ. Wireline uses suitable pressure-control equipment; conventional annular and shear capability must be verified for the actual cable and tools. Do not delay containment by pulling a tool toward surface on an unsupported assumption. Cutting a cable and sealing the well are separate capabilities, and a non-shearable tool across the ram can prevent the intended emergency closure.

For a completion assembly, identify non-sealable and non-shearable items before movement, the flow-check requirement and the assured closure method. The same principle applies to a liner running tool or tubing accessory. The complete procedure must remain usable as the assembly changes position.

Monitoring and handover

After closure, record pressures at the procedure-specified intervals and monitor flow, gains, leaks and gas. A continuing pressure rise can reflect migration or other effects and requires prompt reporting and a pressure-maintenance plan. The handover includes which valves and elements are closed, whether the seals are verified, bit or assembly position, float status and any uncertainty. The next control decision should be based on that evidence, not on a generic assumption that the BOP command solved every path.

Operation-specific closure needs

  • Item Interpretation
  • Drilling Verified pipe-body space-out and selected BOP route
  • Tripping Compatible internal valve plus annular containment
  • Empty hole Qualified empty-bore sealing element
  • Wireline/casing Operation-specific pressure-control configuration