Study guide

7.7 Equipment and Devices Case Lab

Journeyman Electrician Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Orientation and Source Control

1.1 ICC R17, T17, G17, and Jurisdiction Variance 1.2 Current Format, Cost, Time, and Passing Score 1.3 Licensing Board vs. Exam Provider 1.4 Official References, Open-Book Rules, and Calculators 1.5 Domain Weights and Study Map 1.6 Using the Practice Bank, Error Log, and NEC Index

2 Chapter 2: NEC Navigation, Definitions, and Code Strategy

2.1 NEC Book Structure and Article Map 2.2 Article 100 Definitions and Exam Language 2.3 Index, Table, and Annex Navigation 2.4 Shall, Shall Not, Permitted, and Informational Notes 2.5 Using Code References Without Overlooking Context 2.6 State Amendments and Code Edition Control 2.7 NEC Navigation Case Lab

3 Chapter 3: Electrical Theory and Calculation Foundations

3.1 Ohm's Law, Power, and Basic Units 3.2 Series, Parallel, and Circuit Behavior 3.3 Single-Phase, Three-Phase, and Voltage Systems 3.4 Continuous Loads, Demand, and 125 Percent Rules 3.5 Voltage Drop and Practical Calculation Setup 3.6 Load Calculation Workflow 3.7 Calculation Foundation Case Lab

4 Chapter 4: Services, Service Equipment, and Grounding/Bonding

4.1 Service Point, Service Conductors, and Disconnects 4.2 Service Load Calculation and Sizing 4.3 Service Equipment, Panelboards, and Switchboards 4.4 Grounding Electrode System and GEC 4.5 Bonding, Main Bonding Jumpers, and Effective Fault Path 4.6 Transformers and Separately Derived Systems 4.7 Services and Grounding Case Lab

5 Chapter 5: Feeders, Branch Circuits, and Conductor Sizing

5.1 Feeder vs. Branch Circuit Boundaries 5.2 Branch Circuit Ratings and Required Outlets 5.3 Conductor Ampacity, Temperature, and Terminal Ratings 5.4 Adjustment, Correction, and More Than Three Conductors 5.5 Overcurrent Protection and Small-Conductor Rules 5.6 GFCI, AFCI, Equipment Grounding, and Dwelling Circuits 5.7 Feeders and Branch Circuits Case Lab

6 Chapter 6: Wiring Methods, Raceways, Boxes, and Cables

6.1 Raceway Selection and Installation Logic 6.2 Underground Wiring, Wet Locations, and Protection 6.3 Boxes, Enclosures, and Conduit Bodies 6.4 Box Fill, Conductor Counting, and Device Yokes 6.5 Cabinets, Panelboards, and Switchboards 6.6 Flexible Cords, Cables, and Temporary Wiring 6.7 Wiring Methods Case Lab

7 Chapter 7: Equipment, Devices, Luminaires, and Controls

7.1 Receptacles, Switches, and Device Selection 7.2 Luminaires, Lampholders, and Lighting Outlets 7.3 Appliances and Utilization Equipment 7.4 Heating, Cooling, and HVAC Electrical Connections 7.5 Disconnects, Controllers, and Switching Devices 7.6 Equipment Grounding, Bonding, and Listing Markings 7.7 Equipment and Devices Case Lab

8 Chapter 8: Motors, Generators, Transformers, and Special Equipment

8.1 Motor Circuit Anatomy and Article 430 Navigation 8.2 Motor Conductors, Overload, and Short-Circuit Protection 8.3 Motor Controllers, Disconnects, and Nameplates 8.4 Generators, Transfer Equipment, and Optional Standby 8.5 Transformer Sizing, Protection, and Grounding 8.6 Emergency Systems, Fire Alarms, and Signaling Overview 8.7 Motors and Generators Case Lab

9 Chapter 9: Special Occupancies, Renewables, and Safety

9.1 Hazardous Classified Locations 9.2 Healthcare, Marinas, RV Parks, and Mobile Home Parks 9.3 Pools, Spas, and Similar Installations 9.4 Solar PV, Energy Storage, and Renewable Systems 9.5 Temporary Power, Emergency Systems, and Special Conditions 9.6 OSHA Subpart K and Safe Work Practice Context 9.7 Special Occupancies Case Lab

10 Chapter 10: Open-Book Exam Workflow and Mixed Code Labs

10.1 Four-Hour Pacing and Question Triage 10.2 Look-Up vs. Know-From-Memory Decisions 10.3 Mixed Calculation Lab 10.4 Mixed Code Navigation Lab 10.5 Diagnostic Report and Error Log Remediation 10.6 High-Weight Domain Remediation Plan 10.7 Full Exam Simulation Playbook

11 Chapter 11: Final Review, Test Day, and License Planning

11.1 Final Two-Week Study Plan 11.2 Reference Book, Tabs, and Allowed Materials Checklist 11.3 Pearson VUE, PRONTO, and Test-Day Rules 11.4 After the Exam: Results, Retakes, and Challenges 11.5 License Application, Work Hours, and Jurisdiction Next Steps 11.6 After Journeyman: Master, Contractor, and Continuing Education

7.7 Equipment and Devices Case Lab

Key Takeaways Explain This Topic AI

Mixed equipment cases should be solved by separating load, device, location, disconnect, grounding, and listing issues.

The fastest exam method is to identify the article path before calculating or choosing hardware.

Many wrong answers are partly true but ignore a more specific equipment rule or location requirement.

Good field judgment and good exam strategy both depend on reading nameplates and markings before assuming standard practice.

Last updated: May 2026

How to attack mixed equipment cases

Equipment and devices make up a major part of the journeyman outline when the Equipment and Devices and Control Devices domains are combined. The questions are usually not long calculations. They are short practical cases that ask whether the candidate can see the controlling issue: device rating, location, listing, disconnect, grounding, load type, or working/service access.

Use this case method:

  • Step Action Why it works
  • 1 Name the equipment or device Receptacle, luminaire, appliance, motor, HVAC, controller, disconnect
  • 2 Identify the location Dwelling kitchen, bathroom, outdoor, wet, closet, roof, commercial, equipment space
  • 3 Read the rating or nameplate clue Voltage, amperes, watts, MCA, MOCP, horsepower, temperature, wet marking
  • 4 Pick the article path 404, 406, 410, 422, 424, 430, 440, 250, 314, 210
  • 5 Separate functions Control, disconnect, overcurrent protection, grounding, support
  • 6 Check the trap Edition difference, listing instruction, accessibility, grounded conductor, device type

This workflow is slower than guessing but faster than random code searching. On the ICC exam, there is no guessing penalty, and results are generally immediate, but time is tight. You cannot look up every word. You should know the article family and then verify the rule in the NEC edition assigned to your exam: 2023 for R17, 2020 for T17, or 2017 for G17.

Case 1: Exterior receptacle replacement

A dwelling exterior receptacle on a 20 A branch circuit is replaced after the old cover breaks. The installer uses a standard indoor duplex GFCI receptacle and a spring cover that is weatherproof only when closed. The receptacle is on a patio where a cord is commonly left plugged in for lighting.

Sort the facts. Device: receptacle. Location: exterior wet or damp depending on exposure, but likely weather-exposed. Protection: GFCI may be required and is present. Missing issues: weather-resistant marking and cover suitable while in use. Article path: 406 and 210, with enclosure and wet-location rules. The correct answer is not "GFCI makes it safe." GFCI protection, weather resistance, and in-use protection are separate requirements.

Exam trap: If an answer choice says "install a weatherproof cover," check whether it protects with the plug inserted. A cover that works only when closed may be insufficient for an unattended cord-connected load in a wet location.

Case 2: Closet luminaire

A clothes closet has a bare lampholder with an exposed incandescent lamp mounted above a shelf. The homeowner wants a larger lamp because the closet is dim.

Sort the facts. Device: lampholder/luminaire. Location: clothes closet near storage. Load: lamp heat. Article path: 410. The issue is not only wattage. Certain lampholders and luminaires are restricted in clothes closets, and clearances from storage space matter. A larger lamp can worsen the heat hazard. A listed enclosed or recessed luminaire suitable for the location and clearances may be required.

Exam trap: Do not answer by adding a larger breaker or increasing conductor size. The hazard is ignition of combustibles and contact with stored material.

Case 3: Dishwasher and disposal

A dishwasher and garbage disposal are installed under a kitchen sink. The dishwasher nameplate shows 9 A, the disposal shows 7 A, and both are cord-and-plug connected to a duplex receptacle in the sink cabinet. The branch circuit is 20 A.

Sort the facts. Devices: appliances and receptacle. Location: dwelling kitchen, under sink. Load: fastened-in-place appliances. Article path: 422, 210, 406, and possibly GFCI rules in the tested edition. Load math: 9 A + 7 A = 16 A. The circuit may be acceptable from a simple ampere standpoint, but the exam could ask about GFCI protection, receptacle accessibility, whether cord-and-plug connection is permitted, or whether the appliance instructions require individual circuits.

Exam trap: A 20 A circuit does not automatically make the installation acceptable. Listing instructions can be more restrictive, and small-appliance branch circuits are not a default supply for fixed dishwasher/disposal loads.

Case 4: Rooftop HVAC unit

A rooftop unit nameplate shows MCA 32 A and maximum overcurrent protection 50 A. The installer pulls conductors with ampacity at least 32 A and supplies the unit from a 50 A breaker. A disconnect is mounted within sight of the unit. The required 125 V service receptacle is supplied from the load side of the HVAC disconnect.

Sort the facts. Equipment: HVAC. Article path: 440 and 210. Nameplate: conductor sizing from MCA and overcurrent limited by MOCP can be correct. Disconnect: within sight may be correct. Service receptacle: supplying it from the load side of the equipment disconnect is suspect because turning off the HVAC disconnect also kills the service receptacle needed for tools. The correct answer may focus on the receptacle even when the nameplate portion is right.

Exam trap: The wrong answer will attack the 50 A breaker because it looks oversized. Check Article 440 and the nameplate before rejecting it.

Case 5: Smart switch in old switch loop

A smart dimmer is installed where the old switch loop has only an ungrounded conductor feed and switched leg. The installer borrows a neutral from a nearby receptacle circuit.

Sort the facts. Device: electronic lighting control. Article path: 404, 300, 250. Issue: grounded conductor availability and circuit conductor grouping. Borrowing a neutral from another circuit can create objectionable current, overload a neutral, defeat GFCI/AFCI operation, and violate conductor grouping rules. If a neutral is required at the switch location and no exception applies, the fix is not to grab any white wire nearby.

Exam trap: Color alone does not prove circuit function. A white conductor in a switch loop may be reidentified as an ungrounded conductor under permitted conditions in older work.

Case 6: Subpanel and equipment grounds

A feeder supplies a garage panel with two ungrounded conductors, one grounded conductor, and one equipment grounding conductor. In the garage panel, neutrals and equipment grounds are landed on the same bonded bar.

Sort the facts. Equipment: panelboard, feeder, grounding and bonding. Article path: 250 and feeder rules. Since an equipment grounding conductor is run with the feeder, the grounded conductor should be isolated from the enclosure and equipment grounding conductor downstream of the service bonding point. The neutral-to-case bond in the subpanel can put normal neutral current on metal parts.

Exam trap: Grounding electrode systems and equipment grounding conductors do different jobs. A ground rod at the garage would not fix an improper neutral-to-case bond.

Final study drill

For each practice question, write a one-line article path before answering. Example: "Exterior receptacle: 406 plus 210 plus wet-location cover." Example: "Condenser: 440 nameplate plus disconnect plus wet-location wiring." Example: "Closet light: 410 luminaire type and clearance." This habit prevents the most expensive exam mistake: selecting a true statement that answers the wrong article.