Study guide
1.5 Domain Weights and Study Map
Journeyman Electrician Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Orientation and Source Control
1.1 ICC R17, T17, G17, and Jurisdiction Variance 1.2 Current Format, Cost, Time, and Passing Score 1.3 Licensing Board vs. Exam Provider 1.4 Official References, Open-Book Rules, and Calculators 1.5 Domain Weights and Study Map 1.6 Using the Practice Bank, Error Log, and NEC Index
2 Chapter 2: NEC Navigation, Definitions, and Code Strategy
2.1 NEC Book Structure and Article Map 2.2 Article 100 Definitions and Exam Language 2.3 Index, Table, and Annex Navigation 2.4 Shall, Shall Not, Permitted, and Informational Notes 2.5 Using Code References Without Overlooking Context 2.6 State Amendments and Code Edition Control 2.7 NEC Navigation Case Lab
3 Chapter 3: Electrical Theory and Calculation Foundations
3.1 Ohm's Law, Power, and Basic Units 3.2 Series, Parallel, and Circuit Behavior 3.3 Single-Phase, Three-Phase, and Voltage Systems 3.4 Continuous Loads, Demand, and 125 Percent Rules 3.5 Voltage Drop and Practical Calculation Setup 3.6 Load Calculation Workflow 3.7 Calculation Foundation Case Lab
4 Chapter 4: Services, Service Equipment, and Grounding/Bonding
4.1 Service Point, Service Conductors, and Disconnects 4.2 Service Load Calculation and Sizing 4.3 Service Equipment, Panelboards, and Switchboards 4.4 Grounding Electrode System and GEC 4.5 Bonding, Main Bonding Jumpers, and Effective Fault Path 4.6 Transformers and Separately Derived Systems 4.7 Services and Grounding Case Lab
5 Chapter 5: Feeders, Branch Circuits, and Conductor Sizing
5.1 Feeder vs. Branch Circuit Boundaries 5.2 Branch Circuit Ratings and Required Outlets 5.3 Conductor Ampacity, Temperature, and Terminal Ratings 5.4 Adjustment, Correction, and More Than Three Conductors 5.5 Overcurrent Protection and Small-Conductor Rules 5.6 GFCI, AFCI, Equipment Grounding, and Dwelling Circuits 5.7 Feeders and Branch Circuits Case Lab
6 Chapter 6: Wiring Methods, Raceways, Boxes, and Cables
6.1 Raceway Selection and Installation Logic 6.2 Underground Wiring, Wet Locations, and Protection 6.3 Boxes, Enclosures, and Conduit Bodies 6.4 Box Fill, Conductor Counting, and Device Yokes 6.5 Cabinets, Panelboards, and Switchboards 6.6 Flexible Cords, Cables, and Temporary Wiring 6.7 Wiring Methods Case Lab
7 Chapter 7: Equipment, Devices, Luminaires, and Controls
7.1 Receptacles, Switches, and Device Selection 7.2 Luminaires, Lampholders, and Lighting Outlets 7.3 Appliances and Utilization Equipment 7.4 Heating, Cooling, and HVAC Electrical Connections 7.5 Disconnects, Controllers, and Switching Devices 7.6 Equipment Grounding, Bonding, and Listing Markings 7.7 Equipment and Devices Case Lab
8 Chapter 8: Motors, Generators, Transformers, and Special Equipment
8.1 Motor Circuit Anatomy and Article 430 Navigation 8.2 Motor Conductors, Overload, and Short-Circuit Protection 8.3 Motor Controllers, Disconnects, and Nameplates 8.4 Generators, Transfer Equipment, and Optional Standby 8.5 Transformer Sizing, Protection, and Grounding 8.6 Emergency Systems, Fire Alarms, and Signaling Overview 8.7 Motors and Generators Case Lab
9 Chapter 9: Special Occupancies, Renewables, and Safety
9.1 Hazardous Classified Locations 9.2 Healthcare, Marinas, RV Parks, and Mobile Home Parks 9.3 Pools, Spas, and Similar Installations 9.4 Solar PV, Energy Storage, and Renewable Systems 9.5 Temporary Power, Emergency Systems, and Special Conditions 9.6 OSHA Subpart K and Safe Work Practice Context 9.7 Special Occupancies Case Lab
10 Chapter 10: Open-Book Exam Workflow and Mixed Code Labs
10.1 Four-Hour Pacing and Question Triage 10.2 Look-Up vs. Know-From-Memory Decisions 10.3 Mixed Calculation Lab 10.4 Mixed Code Navigation Lab 10.5 Diagnostic Report and Error Log Remediation 10.6 High-Weight Domain Remediation Plan 10.7 Full Exam Simulation Playbook
11 Chapter 11: Final Review, Test Day, and License Planning
11.1 Final Two-Week Study Plan 11.2 Reference Book, Tabs, and Allowed Materials Checklist 11.3 Pearson VUE, PRONTO, and Test-Day Rules 11.4 After the Exam: Results, Retakes, and Challenges 11.5 License Application, Work Hours, and Jurisdiction Next Steps 11.6 After Journeyman: Master, Contractor, and Continuing Education
1.5 Domain Weights and Study Map
Key Takeaways Explain This Topic AI
R17-N, T17-N, and G17-N share the same domain weights in the source brief.
Wiring Methods and Materials is the largest domain at 26%, followed by Branch Circuits and Conductors at 19%.
A study plan should allocate more repetitions to high-weight domains while still protecting smaller domains from becoming easy losses.
Domain weights should drive practice-bank selection, code-navigation drills, and formula review.
Last updated: May 2026
The outline tells you where the points live
The current source brief gives the same domain weights for R17-N, T17-N, and G17-N. These weights do not tell you the exact questions you will see, but they do tell you how to budget study time. A candidate who spends the same number of hours on every domain is ignoring the blueprint.
- Domain Weight Approximate items on 80-question exam
- General Knowledge 6% About 5
- Services and Service Equipment 11% About 9
- Feeders 4% About 3
- Branch Circuits and Conductors 19% About 15
- Wiring Methods and Materials 26% About 21
- Equipment and Devices 13% About 10
- Control Devices 4% About 3
- Motors and Generators 6% About 5
- Special Occupancies, Equipment, and Conditions 11% About 9
The approximate item counts are calculated by multiplying 80 by the domain percentage. The exam does not have to land perfectly on a whole number for your form, but the pattern is clear. Wiring methods, branch circuits, equipment, services, and special topics deserve repeated exposure.
Convert weights into study blocks
A 40-hour study plan should not give every domain 4.4 hours. A better plan starts with the weights, then adds extra time for weak areas. For a first pass, try this allocation:
Domain group Suggested share of study time Why
Wiring Methods and Materials 25% to 30% Largest domain and heavy code-navigation burden.
Branch Circuits and Conductors 18% to 22% High weight, many calculations and required-outlet rules.
Equipment, Services, Special Topics 30% to 35% combined Multiple mid-weight domains with practical field rules.
General, Feeders, Controls, Motors 15% to 20% combined Smaller weights but easy points if routes are known.
Do not make the mistake of studying only the largest domain. A close score can turn on feeders, control devices, or general knowledge. Smaller domains are often efficient because a few article maps and practice sets can recover several points.
Domain-to-NEC route map
The exam outline uses broad categories, while the NEC is organized by articles, chapters, tables, and definitions. Build bridges between the two.
Domain Common navigation starts What to practice
General Knowledge Article 100, Chapter 1 Definitions, authority, installation approval concepts.
Services and Service Equipment Article 230, Article 250 Service conductors, disconnects, grounding and bonding.
Feeders Articles 215, 225, 240, 310 Ampacity, overcurrent, outside feeders, conductor sizing.
Branch Circuits and Conductors Articles 210, 220, 240, 310 Required circuits, loads, conductor sizing, protection.
Wiring Methods and Materials Chapter 3, Chapter 9 Raceways, cables, boxes, fill, support, fittings.
Equipment and Devices Articles 404, 406, 408, 422 Switches, receptacles, panelboards, appliances.
Control Devices Article 404 and equipment articles Switching, control circuits, disconnecting means.
Motors and Generators Articles 430, 445 Motor FLC, overload, short-circuit protection, generators.
Special Occupancies, Equipment, Conditions Chapters 5, 6, 7 Hazardous locations, health care, PV, emergency systems.
Calculation setup by domain
Some domains are lookup-heavy. Others are calculation-heavy. Your plan should include both.
Branch-circuit and feeder problems often start with load in VA or amperes. Wiring-method problems may require box fill, conduit fill, or ampacity adjustment. Motor questions often require using NEC motor full-load current tables instead of the equipment nameplate for certain calculations.
Core formulas to recognize:
- amperes = watts / volts
- VA = volts x amperes
- three-phase VA = volts x amperes x 1.732
- continuous load sizing = load x 125% when the rule requires it
- adjusted ampacity = base ampacity x correction factor x adjustment factor
The exam trap is usually not multiplication. It is choosing the wrong base value. If the question asks for conductor ampacity, you may need Article 310 and adjustment factors. If it asks for overcurrent protection, you may need Article 240 or a motor-specific rule. If it asks for a service or feeder load, Article 220 may control.
Use the local practice bank intelligently
The local practice bank has 200 journeyman-electrician items. Its current category counts are uneven: definitions are high, control devices are low, and renewable energy appears even though the ICC outline uses the broader special equipment and conditions frame.
Use the bank as a workout, not as a perfect exam blueprint. Map each practice category back to the ICC domain weights.
Practice category Current count Best use
electrician-nec-definitions 46 Build Article 100 speed and general code vocabulary.
electrician-branch-circuits 31 Train required circuits, loads, receptacles, and conductor logic.
electrician-services-equipment 27 Drill service and grounding routes.
electrician-wiring-methods 25 Add extra outside practice because the exam weight is 26%.
electrician-equipment-devices 20 Practice device, panelboard, appliance, and equipment rules.
electrician-motors-generators 15 Build Article 430 table discipline.
electrician-special-occupancies 15 Use for Chapter 5, 6, and 7 navigation.
electrician-feeders 10 Supplement if feeder calculations are weak.
electrician-renewable-energy 10 Treat as special equipment practice.
electrician-control-devices 1 Supplement from code drills because the bank is thin.
Weekly study map
A practical week should mix reading, lookup, and timed questions. Do not wait until the final week to practice timing.
Day 1: Wiring methods article map plus conduit or box-fill drills.
Day 2: Branch circuits and conductor sizing questions.
Day 3: Services, grounding, and bonding routes.
Day 4: Equipment, devices, and panelboard or appliance rules.
Day 5: Motors, feeders, and control devices.
Day 6: Special occupancies and renewable or emergency systems.
Day 7: Timed mixed set, error log, and NEC index cleanup.
Exam trap: studying by comfort
Many candidates over-study the work they do every day and under-study unfamiliar chapters. Residential-focused candidates may skip motors or special occupancies. Commercial candidates may underestimate dwelling branch-circuit rules. Service electricians may know field fixes but still need exact NEC table navigation.
Use the weights to correct comfort bias. The exam is not asking what you usually install. It is sampling the outline.