Study guide
2.2 Article 100 Definitions and Exam Language
Journeyman Electrician Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Orientation and Source Control
1.1 ICC R17, T17, G17, and Jurisdiction Variance 1.2 Current Format, Cost, Time, and Passing Score 1.3 Licensing Board vs. Exam Provider 1.4 Official References, Open-Book Rules, and Calculators 1.5 Domain Weights and Study Map 1.6 Using the Practice Bank, Error Log, and NEC Index
2 Chapter 2: NEC Navigation, Definitions, and Code Strategy
2.1 NEC Book Structure and Article Map 2.2 Article 100 Definitions and Exam Language 2.3 Index, Table, and Annex Navigation 2.4 Shall, Shall Not, Permitted, and Informational Notes 2.5 Using Code References Without Overlooking Context 2.6 State Amendments and Code Edition Control 2.7 NEC Navigation Case Lab
3 Chapter 3: Electrical Theory and Calculation Foundations
3.1 Ohm's Law, Power, and Basic Units 3.2 Series, Parallel, and Circuit Behavior 3.3 Single-Phase, Three-Phase, and Voltage Systems 3.4 Continuous Loads, Demand, and 125 Percent Rules 3.5 Voltage Drop and Practical Calculation Setup 3.6 Load Calculation Workflow 3.7 Calculation Foundation Case Lab
4 Chapter 4: Services, Service Equipment, and Grounding/Bonding
4.1 Service Point, Service Conductors, and Disconnects 4.2 Service Load Calculation and Sizing 4.3 Service Equipment, Panelboards, and Switchboards 4.4 Grounding Electrode System and GEC 4.5 Bonding, Main Bonding Jumpers, and Effective Fault Path 4.6 Transformers and Separately Derived Systems 4.7 Services and Grounding Case Lab
5 Chapter 5: Feeders, Branch Circuits, and Conductor Sizing
5.1 Feeder vs. Branch Circuit Boundaries 5.2 Branch Circuit Ratings and Required Outlets 5.3 Conductor Ampacity, Temperature, and Terminal Ratings 5.4 Adjustment, Correction, and More Than Three Conductors 5.5 Overcurrent Protection and Small-Conductor Rules 5.6 GFCI, AFCI, Equipment Grounding, and Dwelling Circuits 5.7 Feeders and Branch Circuits Case Lab
6 Chapter 6: Wiring Methods, Raceways, Boxes, and Cables
6.1 Raceway Selection and Installation Logic 6.2 Underground Wiring, Wet Locations, and Protection 6.3 Boxes, Enclosures, and Conduit Bodies 6.4 Box Fill, Conductor Counting, and Device Yokes 6.5 Cabinets, Panelboards, and Switchboards 6.6 Flexible Cords, Cables, and Temporary Wiring 6.7 Wiring Methods Case Lab
7 Chapter 7: Equipment, Devices, Luminaires, and Controls
7.1 Receptacles, Switches, and Device Selection 7.2 Luminaires, Lampholders, and Lighting Outlets 7.3 Appliances and Utilization Equipment 7.4 Heating, Cooling, and HVAC Electrical Connections 7.5 Disconnects, Controllers, and Switching Devices 7.6 Equipment Grounding, Bonding, and Listing Markings 7.7 Equipment and Devices Case Lab
8 Chapter 8: Motors, Generators, Transformers, and Special Equipment
8.1 Motor Circuit Anatomy and Article 430 Navigation 8.2 Motor Conductors, Overload, and Short-Circuit Protection 8.3 Motor Controllers, Disconnects, and Nameplates 8.4 Generators, Transfer Equipment, and Optional Standby 8.5 Transformer Sizing, Protection, and Grounding 8.6 Emergency Systems, Fire Alarms, and Signaling Overview 8.7 Motors and Generators Case Lab
9 Chapter 9: Special Occupancies, Renewables, and Safety
9.1 Hazardous Classified Locations 9.2 Healthcare, Marinas, RV Parks, and Mobile Home Parks 9.3 Pools, Spas, and Similar Installations 9.4 Solar PV, Energy Storage, and Renewable Systems 9.5 Temporary Power, Emergency Systems, and Special Conditions 9.6 OSHA Subpart K and Safe Work Practice Context 9.7 Special Occupancies Case Lab
10 Chapter 10: Open-Book Exam Workflow and Mixed Code Labs
10.1 Four-Hour Pacing and Question Triage 10.2 Look-Up vs. Know-From-Memory Decisions 10.3 Mixed Calculation Lab 10.4 Mixed Code Navigation Lab 10.5 Diagnostic Report and Error Log Remediation 10.6 High-Weight Domain Remediation Plan 10.7 Full Exam Simulation Playbook
11 Chapter 11: Final Review, Test Day, and License Planning
11.1 Final Two-Week Study Plan 11.2 Reference Book, Tabs, and Allowed Materials Checklist 11.3 Pearson VUE, PRONTO, and Test-Day Rules 11.4 After the Exam: Results, Retakes, and Challenges 11.5 License Application, Work Hours, and Jurisdiction Next Steps 11.6 After Journeyman: Master, Contractor, and Continuing Education
2.2 Article 100 Definitions and Exam Language
Key Takeaways Explain This Topic AI
Article 100 definitions control how NEC words are used, even when everyday trade language sounds similar.
Exam stems often hinge on one defined term such as service, feeder, branch circuit, outlet, equipment, listed, or qualified person.
Definitions can be general or article-specific, so check whether the word has a special meaning in the article being tested.
Do not answer from jobsite slang when the question uses code vocabulary.
When two answers seem plausible, the defined term in the stem often decides which rule applies.
Last updated: May 2026
Definitions are navigation controls
Article 100 is not a glossary you read once and forget. It is a control panel for the rest of the NEC. Many journeyman questions are built around a defined word, and the answer changes when that word is read in its code meaning instead of its everyday meaning. If a stem says service conductors, feeder, branch circuit, outlet, receptacle, equipment, premises wiring, listed, labeled, accessible, readily accessible, or qualified person, pause and make sure the term means what you think it means.
A common trap is using jobsite shorthand. In the field, someone may call almost any panel a service panel, any cable a feed, or any device box an outlet box. On the exam, those words carry sharper boundaries. Service conductors are not the same thing as feeder conductors. A feeder is not a branch circuit. An outlet is not always a receptacle. A receptacle outlet is not the same as a lighting outlet. These distinctions point you to different articles and sometimes different load, protection, and installation rules.
Stem word Exam meaning to verify Navigation effect
Service Conductors and equipment related to utility supply to premises wiring Look toward Article 230 and service grounding rules
Feeder Conductors between service equipment or source and final branch-circuit overcurrent device Look toward Article 215 and panelboard context
Branch circuit Conductors after the final overcurrent device supplying outlets or loads Look toward Article 210
- Outlet Point where current is taken to supply utilization equipment Do not assume it means receptacle only
- Receptacle Contact device for attachment plug connection Look for receptacle-specific rules
Listed Equipment included in a recognized evaluation list Consider product standards and installation instructions
Readily accessible Reachable quickly without climbing over or removing obstacles Different from merely accessible
Similar words, different rules
Accessible and readily accessible are good examples. Something can be accessible if it can be reached after removing a panel or using tools, depending on the context. Readily accessible is a stricter idea: the person should be able to reach it quickly without special effort such as moving obstacles or using a portable ladder. Exam questions may describe a disconnect behind stored materials or above a suspended ceiling. The answer depends on the code term, not on whether a technician could eventually get to it.
Outlet and receptacle also cause errors. An outlet is the point on the wiring system where current is taken to supply equipment. A receptacle is a specific contact device. A hardwired luminaire outlet, a smoke alarm outlet, and a receptacle outlet are not identical. If a rule says receptacle outlet, do not apply it automatically to every outlet. If it says outlet, do not narrow it to cord-and-plug devices unless the surrounding rule does.
Service, feeder, and branch circuit are the backbone definitions for the exam. The service is on the supply side of the service disconnecting means and associated service equipment. Feeders carry power from service equipment or another source to branch-circuit overcurrent devices. Branch circuits run from the final overcurrent device to outlets and utilization equipment. When a question asks conductor sizing, overcurrent protection, voltage drop planning, or grounding, identifying this boundary is often half the answer.
General definitions and article-specific definitions
Some terms appear in Article 100, while others are defined inside a specific article. A definition inside Article 517, Article 680, Article 690, or another special article may apply only in that context. The NEC also uses scope statements and article definitions to tell you whether you are standing inside a special rule set. That is why a pool question, a photovoltaic question, or a health care question should not be solved only from the general definition you remember.
The exam can hide a special definition in plain sight. For example, a question may use a term from a special occupancy or special equipment article. If the answer choices all look like general wiring rules but the stem describes a hazardous location, patient care area, swimming pool, generator, or PV source circuit, check the special article before committing. The special article may define the system part differently or impose additional requirements.
How to use definitions under time pressure
Do not open Article 100 for every word. Use it when the word controls the article path or when answer choices differ by category. A fast method is:
Circle the noun in the stem: feeder, service, branch circuit, receptacle, outlet, equipment, raceway, conductor, or appliance.
Ask whether that noun has a code definition that affects the rule.
If yes, check Article 100 or the relevant article definition before reading detailed requirements.
Translate the stem into the correct article family.
Read the rule using the defined meaning, not the jobsite nickname.
This process is especially useful when two answers seem reasonable. Suppose a question asks about the final circuit conductors supplying receptacle outlets in an office. If the conductors are after the final overcurrent device, the code concept is branch circuit. A feeder rule may be nearby in the book and may even sound related, but it is the wrong layer.
Definition-based case examples
Case 1: A question asks for the rule covering conductors from a service disconnect to a downstream panelboard that contains branch-circuit breakers. The key phrase is from the service disconnect to the downstream panelboard. Those conductors are feeders, not service conductors and not branch circuits. Start with Article 215 and supporting rules for conductor ampacity, overcurrent protection, and grounding or bonding.
Case 2: A question asks whether a box with a hardwired wall sconce is an outlet. It is. Current is taken from the wiring system to supply utilization equipment. It is not a receptacle unless a contact device for an attachment plug is installed. This distinction matters when a rule applies to receptacle outlets rather than all outlets.
Case 3: A question says equipment must be listed and installed according to instructions. Do not treat listed as a casual label or brand claim. Code use of listing relates to evaluation by an organization concerned with product safety. If the equipment is listed for one use, the exam may ask whether using it in another way is permitted. Follow the listing and the NEC rule together.
Definitions are a speed tool because they keep you from reading the wrong article. They are also a scoring tool because many multiple-choice distractors are built from almost-correct trade language. When the stem uses a defined word, let the NEC definition drive the answer.