Study guide

11.4 Categories 11, 12 & 13: Aerial and the Fumigation Categories

Kentucky Commercial Pesticide Applicator Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Federal and Kentucky Pesticide Laws

1.1 Federal Regulatory Framework 1.2 Kentucky Pesticide Laws & KDA Administration 1.3 Kentucky Administrative Regulations & Licensing Classes 1.4 Supervising Trainees & Non-Certified Applicators

2 Chapter 2: Restricted-Use Pesticides, Records & Label Compliance

2.1 Restricted-Use Pesticides (RUP) & Dealer Requirements 2.2 Kentucky Record-Keeping & Reporting Mandates 2.3 Reading & Understanding Pesticide Labels 2.4 Kentucky Posting & Customer Notification Rules

3 Chapter 3: Pesticide Toxicity, Human Health & Exposure

3.1 Principles of Pesticide Toxicology 3.2 Routes of Exposure & Health Effects 3.3 First Aid, Decontamination & Medical Response 3.4 Common Pesticide Mishaps & Bystander Protection

4 Chapter 4: Personal Protective Equipment & Safety Standards

4.1 Chemical-Resistant PPE Selection & Maintenance 4.2 Respiratory Protection & NIOSH Standards 4.3 Worker Protection Standard (WPS) & Agricultural Safety 4.4 Transporting Pesticides Safely

5 Chapter 5: Environmental Fate & Kentucky Karst Protection

5.1 Environmental Fate & Pesticide Movement 5.2 Kentucky Karst Topography & Groundwater Protection 5.3 Surface Water Protection & Runoff Control

6 Chapter 6: Spray Drift Management & Pollinator Protection

6.1 Spray Drift Factors & Droplet Size Management 6.2 Weather Conditions & Thermal Inversions 6.3 Pollinator Protection & Non-Target Organism Safety

7 Chapter 7: Pesticide Formulations, Packaging & Handling

7.1 Liquid & Dry Formulations 7.2 Adjuvants, Surfactants & Tank-Mix Compatibility 7.3 Storage, Security, Container Rinsing & Spill Response 7.4 Pesticide Types, Modes of Action & Selectivity

8 Chapter 8: Application Equipment & Calibration Calculations

8.1 Application Equipment & Nozzle Selection 8.2 Sprayer Calibration Formulas & Speed Calculations 8.3 Area, Volume & Tank-Mix Math 8.4 Application Methods & Selecting the Right One

9 Chapter 9: Integrated Pest Management & Kentucky Categories

9.1 Integrated Pest Management (IPM) Principles 9.2 Pesticide Resistance Management 9.3 Kentucky Commercial Certification Categories 9.4 Pest Identification & Verifying the Label Permits the Use

10 Chapter 10: Residues, Chemical Security & Professional Practice

10.1 Residues, Tolerances & Preharvest Intervals 10.2 Chemical Security & Product Stewardship 10.3 Communicating Pesticide Risk to Customers and the Public

11 Chapter 11: Kentucky Category Standards in Depth

11.1 Categories 1(a), 1(b), 2 & 4: Agricultural, Forest & Seed Treatment 11.2 Categories 3, 5 & 6: Ornamental/Turf, Aquatic & Right-of-Way 11.3 Categories 7, 8, 9 & 10: Structural, Public Health, Regulatory & Research 11.4 Categories 11, 12 & 13: Aerial and the Fumigation Categories

11.4 Categories 11, 12 & 13: Aerial and the Fumigation Categories

Key Takeaways Explain This Topic AI

Category 11 covers fixed wing, rotary wing, and unmanned aerial vehicles, and Section 3(11) requires the holder to also possess an additional license in another category related to the location of the intended target pest.

The Section 5(11) aerial standard has five parts - labeling, application equipment, application considerations, minimizing drift, and performing the application - with eleven separate equipment competencies.

Category 12 is soil fumigation and Category 13 is non-soil fumigation excluding structures intended for human occupancy; structures intended for human occupancy fall under Category 7(b).

Fumigant standards require knowledge of fumigant management plans, post-application summaries, buffer zones and who may be in them, air monitoring, sealing methods, and respirator medical evaluation, fit testing, and recordkeeping.

Section 5(11)(e) makes recordkeeping requirements for aerial applications, including application conditions where applicable, part of the aerial competency itself.

Last updated: September 2026

11.4 Categories 11, 12 & 13: Aerial and the Fumigation Categories

Note

Why these three carry the longest standards. 302 KAR 26:020 Section 4(7)(b) makes it a core competency to know that fumigation and aerial application require additional certification . Section 5 then spends more text on Categories 11 and 12 than on any other categories in the regulation, because a fumigant escape or an aerial drift event injures people who never agreed to be near the application.

Category 11: Aerial

Section 3(11) scope. Persons applying pesticides using fixed or rotary wing aircraft or unmanned aerial vehicles . And then the requirement candidates most often miss: "Persons obtaining this category shall also possess an additional license in another category that relates to the location of the intended target pest." Category 11 authorizes the platform ; a second category authorizes the site . A drone application to corn needs Category 11 plus Category 1(a).

Section 5(11) competency has five lettered parts:

(a) Labeling

Labeling requirements and restrictions specific to aerial application, including spray volumes , buffers and no-spray zones , and weather conditions specific to wind and inversions .

(b) Application Equipment - Eleven Named Competencies

The regulation enumerates them, and they read like a checklist:

  • The importance of inspecting application equipment to ensure proper operating condition before beginning;
  • Selecting proper nozzles to ensure appropriate dispersal and minimize drift;
  • Knowledge of the components of an aerial system - hoppers, tanks, pumps, and types of nozzles ;
  • Interpreting a nozzle flow rate chart ;

Determining the number of nozzles for intended output using the flow rate chart, aircraft speed, and swath width ;

Placing nozzles to compensate for uneven airflow from wingtip vortices, helicopter rotor turbulence, and propeller turbulence ;

Where to place nozzles to produce the appropriate droplet size ;

Maintaining the system - pressure gauge accuracy, filter cleaning on schedule, checking nozzles for excessive wear ;

  • Calculating required and actual flow rates ;
  • Verifying flow rate using fixed timing, open timing, known distance, or a flow meter;

When to adjust and calibrate .

Items 4, 5, 9, and 10 are the aerial analogue of the ground calibration math in Section 8.2: the variables become aircraft speed and swath width instead of ground speed and nozzle spacing, but the logic - output per unit area - is identical.

(c) Application Considerations

Weather conditions that affect engine power, take-off distance, and climb rate , or that promote spray droplet evaporation ; how to determine wind velocity, direction, and air density at the site; and the potential impact of thermals and temperature inversions .

(d) Minimizing Drift

Determining drift potential using a smoke generator ; evaluating vertical and horizontal smoke plumes to assess wind direction, speed, and concentration; selecting techniques that minimize movement out of the treated area; and documenting special equipment configurations or flight patterns used to reduce off-target drift.

(e) Performing the Application

Selecting a flight altitude that minimizes streaking and off-target drift ; choosing a flight pattern that ensures applicator and bystander safety; engaging and disengaging spray precisely at swath entry and exit; swath marking tools such as GPS and flags; and recordkeeping requirements for aerial applications including application conditions if applicable .

Note that the regulation puts recordkeeping inside the competency standard , and separately, 302 KAR 26:030 Section 2(2)(n) sweeps in "any other record as required by the label" - which on many aerial labels means wind speed, direction, and temperature at the time of application.

The Fumigation Boundary: 12, 13, and 7(b) +-----------------------------------------------------------------------------+

  • | WHICH FUMIGATION CATEGORY APPLIES? |
  • +-----------------------------------------------------------------------------+
  • | |
  • | Are you fumigating SOIL? |
  • | YES -> CATEGORY 12 (Soil Fumigation) |
  • | NO -> continue |
  • | |
  • | Is the thing being fumigated a STRUCTURE INTENDED FOR |
  • | HUMAN OCCUPANCY? |
  • | YES -> CATEGORY 7(b) (Structural Fumigation) |
  • | NO -> CATEGORY 13 (Non-Soil Fumigation) |
  • | |
  • | Stored grain, commodities, rail cars, containers, chambers -> 13 |
  • | Tented dwelling, occupied building -> 7(b) |
  • | Pre-plant field, nursery bed, greenhouse soil -> 12 |
  • +-----------------------------------------------------------------------------+

Remember the history: the pre-2022 Category 1(b) Agricultural Fumigation was converted by Section 10(2) into Categories 12 and 13 . Stored-grain fumigation is now a Category 13 activity.

Category 12: Soil Fumigation

Section 3(12) scope. Persons who use or supervise the use of a pesticide to fumigate soil .

Section 5(12) competency opens with labeling comprehension for soil fumigants, requiring familiarity with:

Labeling requirements specific to soil fumigants ;

Requirements for certified applicators of fumigants, fumigant handlers and permitted fumigant handler activities , and the safety information certified applicators must provide to noncertified applicators using fumigants under their direct supervision;

  • Entry-restricted periods for tarped and untarped field application scenarios ;
  • Recordkeeping requirements ; and

Labeling provisions unique to fumigant products containing certain active ingredients.

It continues into safety measures paralleling the non-soil fumigant standard. Operationally, Category 12 work in Kentucky means chloropicrin, metam sodium, metam potassium, and dazomet in specialty vegetable, strawberry plasticulture, nursery, and greenhouse soils, with tarping versus water seal as the sealing decision, EPA Fumigant Management Plans required before application, buffer zones calculated from application rate, block size, and method, and handler air monitoring .

Category 13 and 7(b): The Non-Soil Fumigant Standard

Section 5(7)(b) sets out the eight-part standard that governs non-soil fumigation. It is worth knowing by its structure:

Part What it requires

1. Label and labeling comprehension Familiarity with labels for non-soil fumigation products, including requirements specific to non-soil fumigants

2. Safety How certified applicators, noncertified applicators under supervision, and bystanders become exposed; common mistakes producing direct exposure; signs and symptoms ; air concentrations that require respirators or exiting the work area ; steps to take on sensory irritation ; air monitoring - when required and where and when to sample; buffer zones, buffer zone monitoring, and who is permitted to be in a buffer zone ; first aid ; and labeling requirements for transport, storage, spill cleanup, emergency response, safe container disposal, and management of empty containers

3. Chemical characteristics Chemistry of non-soil fumigants; specific human exposure concerns; how fumigants change from liquid or solid to gas ; how they disperse in the application zone ; compatibility with tanks, hoses, tubing, and equipment

4. Application Methods and equipment; site characteristics that influence exposure ; conditions affecting timing such as air stability, air temperature, humidity, and wind currents ; pre-application inspection of equipment and site; purpose and methods of sealing and the factors determining which sealing method to use; calculating product quantity for a treatment area; basic calibration of non-soil fumigant equipment; and when and how to conduct air monitoring

5. Pest factors Influence of pest factors on fumigant volatility ; factors influencing gaseous movement through the area and into the air; identifying the pest and verifying fumigation will control it; relationship between pest density and application rate ; importance of proper rate and timing

6. Personal protective equipment Following labeling directions for required PPE; selecting, inspecting, using, caring for, replacing, and disposing of PPE ; the types of respirators required for specific fumigants and how to use them properly including medical evaluation, fit testing, and required replacement of cartridges and canisters ; and labeling requirements and other laws applicable to medical evaluation, fit tests, training, and recordkeeping

7. Fumigant management plans and post-application summaries When an FMP must be in effect, how long it is kept on file, where it is kept during the application, and who has access ; the elements of an FMP and the resources available to prepare one; who verifies the FMP is accurate ; and the elements, purpose, and content of a post-application summary, who prepares it, and when it is completed

8. Posting requirements Who is allowed in an area being fumigated or after fumigation, and who is prohibited ; distinguishing labeling-required posting from treated-area posting , including the pre-application and post-application posting timeframes for each; and proper choice and placement of warning signs

Two structural points to carry into the exam. First, the fumigant management plan is a document with an owner, a location, a retention period, an access list, and a verifier - the regulation asks about all five. Second, buffer zones are not merely distances; the standard asks who is permitted to be inside one and how it is monitored.

Kentucky Category 13 work is dominated by phosphine (aluminum and magnesium phosphide) in stored grain, elevators, and rail cars, where the exposure hazards are the delayed generation of gas from the formulation, the risk of a flammable atmosphere, and re-entry timing after aeration. Category 7(b) work is dominated by sulfuryl fluoride in tented structures, where occupant and neighbor clearance, warning agent use, and clearance air monitoring before re-occupancy control the job.

Exam Alert: Two things reliably decide fumigation questions: the soil / human-occupancy decision tree that separates 12, 13, and 7(b); and the fumigant management plan's five attributes - when it is in effect, how long it is kept, where it is kept during the application, who has access, and who verifies it. For aerial, remember that Category 11 alone is never enough - you also need a category matching the target site.